Practice Problem Set 11 Gas Chromatography

Similar documents
Fractional Distillation and Gas Chromatography

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

Gas Chromatography. Gas Chromatograph

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Alkanes. Chapter 1.1

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Theory and Instrumentation of GC Introduction

Analyzing Small Molecules by EI and GC-MS. July 2014

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

H 3 C CH 2 CH 2 CH 2 CH 2 CH 3. Copyright 2012 Nelson Education Ltd. Chapter 1: Organic Compounds 1.1-1

Ferda ORHUN Mineral Research and Exploration Institute of Turkey

Page Which hydrocarbon is a member of the alkane series? (1) 1. Which is the structural formula of methane? (1) (2) (2) (3) (3) (4) (4)

GAS CHROMATOGRAPHY. DETERMINING THE PERCENT COMPOSITION OF A MIXTURE OF VOLATILE LIQUIDS USING A GAS CHROMATOGRAPH. (Revised: )

PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative

Gas Chromatography Liner Selection Guide

BTU ANALYSIS USING A GAS CHROMATOGRAPH

CHM220 Addition lab. Experiment: Reactions of alkanes, alkenes, and cycloalkenes*

Name Lab #3: Solubility of Organic Compounds Objectives: Introduction: soluble insoluble partially soluble miscible immiscible

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

Unit Vocabulary: o Organic Acid o Alcohol. o Ester o Ether. o Amine o Aldehyde

Diffusion and Fluid Flow

23 The Thermal Conductivity Detector

Separation of Amino Acids by Paper Chromatography

13C NMR Spectroscopy

Background Information

Chapter 5 Classification of Organic Compounds by Solubility

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

ß-CYCLODEXTRIN SYNONYMS

Purification of reaction mixtures using flash chromatography.

Pesticide Analysis by Mass Spectrometry

Gas Separations: A Comparison of GasPro and Aluminum Oxide PLOT Columns for the Separation of Highly Volatile Compounds

HEXANES. Insoluble in water, soluble in ether, alcohol, and acetone. Neutral to methyl orange (ph indicator) Not more than 0.

States of Matter and the Kinetic Molecular Theory - Gr10 [CAPS]

Organic Chemistry Tenth Edition

Chapter 21 Principles of Chromatography and Mass Spectrometry Problems 1,2,3,4,8,9,11,13

EXPERIMENT 1 - Determination of the purity and identity of organic compounds by melting point and/or analytical thin layer chromatography

Paper Chromatography: Separation and Identification of Five Metal Cations

83 to 87% carbon 11-15% hydrogen 0.1-7% sulphur % oxygen % nitrogen

Question Bank Organic Chemistry-I

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

Alcohols An alcohol contains a hydroxyl group ( OH) attached to a carbon chain. A phenol contains a hydroxyl group ( OH) attached to a benzene ring.

Balancing chemical reaction equations (stoichiometry)

MINERAL OIL (MEDIUM VISCOSITY)

CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA ABSTRACT

Chemistry Diagnostic Questions

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

4.5 Physical Properties: Solubility

Experiment 5: Column Chromatography

Addressing the World Helium Shortage For Gas Chromatography

Chem 112 Intermolecular Forces Chang From the book (10, 12, 14, 16, 18, 20,84,92,94,102,104, 108, 112, 114, 118 and 134)

Chemistry Assessment Unit AS 1

Review - After School Matter Name: Review - After School Matter Tuesday, April 29, 2008

Chapter 12 - Liquids and Solids

SUCRALOSE. White to off-white, practically odourless crystalline powder

Bomb Calorimetry. Electrical leads. Stirrer

Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

CHE334 Identification of an Unknown Compound By NMR/IR/MS

Gerhard Schomburg. Gas Chromatography. A Practical Course. -«WTM-JY// ^ Weinheim New York. VCH XJ Basel Cambridge

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

Part B 2. Allow a total of 15 credits for this part. The student must answer all questions in this part.

Classification of Chemical Substances

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

Specimen Paper. Chemistry 1F. Time allowed! 60 minutes

ORGANIC COMPOUNDS IN THREE DIMENSIONS

m/z

Chemistry. The student will be able to identify and apply basic safety procedures and identify basic equipment.

KINETIC THEORY OF MATTER - molecules in matter are always in motion - speed of molecules is proportional to the temperature

MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

The Theory of HPLC. Gradient HPLC

CHAPTER 10: INTERMOLECULAR FORCES: THE UNIQUENESS OF WATER Problems: 10.2, 10.6, , , ,

States of Matter CHAPTER 10 REVIEW SECTION 1. Name Date Class. Answer the following questions in the space provided.

IB Chemistry. DP Chemistry Review

Mass Spectrometry. Fundamental GC-MS. GC Considerations

The photoionization detector (PID) utilizes ultraviolet

ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC)

C184-E014D GC Shimadzu Gas Chromatograph System

Chapter 5 Student Reading

Laboratory 22: Properties of Alcohols

Chapter 13 Organic Chemistry

Synthesis of Isopentyl Acetate

Molar Mass of Butane

CHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS

Name Class Date. In the space provided, write the letter of the term or phrase that best completes each statement or best answers each question.

Hydrogen as an alternative to Helium for gas chromatography.

GCSE COMBINED SCIENCE: TRILOGY

Chapter 4. Chemical Energy

CHEMISTRY II FINAL EXAM REVIEW

SULFUR COMPOUNDS IN PETROLEUM HYDROCARBON STREAMS

Alcohols. Copyright 2009 by Pearson Education, Inc. Copyright 2009 Pearson Education, Inc. CH 3 CH 2 CH 2 OH 1-propanol OH

CHROMOCTANE O N LINE ANALYZER

Calorimetry: Heat of Vaporization

Chapter 5 - Aircraft Welding

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Fundamentals of Gas Chromatography

VAPORIZATION IN MORE DETAIL. Energy needed to escape into gas phase GAS LIQUID. Kinetic energy. Average kinetic energy

Air Sampling for Gases and Vapors. Patrick N. Breysse, PhD, CIH Peter S.J. Lees, PhD, CIH Johns Hopkins University

Transcription:

Practice Problem Set 11 Gas Chromatography 27-1 How do gas-liquid and gas-solid chromatography differ? The stationary phase in GLC is a liquid at operating temperature while it is a solid in GSC. Primarily, GSC is used for separation of polar compounds that are usually not retained in GLC like hydrogen sulfide, nitrogen oxides, sulfur dioxide, carbon mono and dioxide, as well as other gases. 27-2 What is meant by retention volume? The retention volume of a solute is defined as its retention time times average flow rate. V R = t R F 27.3 What is meant by temperature programming in GC? Why is it frequently used? Temperature programming in gas chromatography is the main technique used to optimize a separation. In TPGC, the temperature of the column is increased as a function of time. The program is designed in order to fully and efficiently separate compounds that differ significantly in boiling points. Initially low boiling compounds are separated at low temperatures followed by increasing the temperature to allow the separation of other compounds. The increase in temperature can be linear, stepwise, parabolic or combinations so that best separations are obtained. It is frequently used in GC because it is the major tool for optimization of a separation. 27-4. What is the difference between a concentration-sensitive and a mass-sensitive detector? A concentration sensitive detector responds to concentration of analytes, which means that the same concentration of analytes will result in same signal value. However, mass sensitive detectors respond to number of active groups in the molecule. 27-5. Are the following detectors mass or concentration sensitive? (a) thermal conductivity, (b) electron capture, (c) flame ionization. Detector Type Thermal Conductivity Detector Concentration sensitive Flame ionization Detector Mass Sensitive Electron Capture Detector Mass Sensitive 27-6. Describe the principles of operation for the detectors listed in Question number 27-5. a. TCD This is a nondestructive detector which is used for the separation and collection of solutes to further perform some other experiments on each purely separated component. The heart of the detector is a heated filament which is cooled by helium 1

carrier gas. Any solute passes across the filament will not cool it as much as helium does because helium has the highest thermal conductivity. This results in an increase in the temperature of the filament which is related to concentration. The detector is simple, nondestructive, and universal but is not very sensitive and is flow rate sensitive. b. Flame Ionization Detector (FID) This is one of the most sensitive and reliable destructive detectors. Separate two gas cylinders, one for fuel and the other for O 2 or air are used in the ignition of the flame of the FID. The fuel is usually hydrogen gas. The flow rate of air and hydrogen should be carefully adjusted in order to successfully ignite the flame. The FID detector is a mass sensitive detector where solutes are ionized in the flame and electrons emitted are attracted by a positive electrode which is shown as a current and a signal is obtained. The FID detector is not responsive to air, water, carbon disulfide. This is an extremely important advantage where volatile solutes present in water matrix can be easily analyzed without any pretreatment. c. Electron Capture Detector (ECD) This detector exhibits high intensity for halogen containing compounds and thus has found wide applications in the detection of pesticides and polychlorinated biphenyls. The mechanism of sensing relies on the fact that electronegative atoms, like halogens, will capture electrons from a β emitter (usually 63 Ni). In absence of halogenated compounds, a high current signal will be recorded due to high ionization of the carrier gas which is N 2, while in presence of halogenated compounds the signal will decrease due to lower ionization. 27-7. What are the major advantages and the principal limitations of each of the detectors listed in Question a. TCD characteristics include: Rugged Wide dynamic range (10 5 ) Nondestructive 2

Insensitive (10-8 g/s) Flow rate sensitive Almost Universal b. FID characteristics include: Rugged Sensitive (10-13 g/s) Wide dynamic range (10 7 ) Signal depends on number of carbon atoms in organic analytes which is referred to as mass sensitive rather than concentration sensitive Weakly sensitive to carbonyl, amine, alcohol, amine groups Not sensitive to non-combustibles - H 2 O, CO 2, SO 2, NO x Destructive c. ECD characteristics include: Electrons from a β-source ionize the carrier gas (nitrogen) Organic molecules containing electronegative atoms capture electrons and decrease current Simple and reliable Sensitive (10-15 g/s) to electronegative groups (halogens) Largely non-destructive Insensitive to amines, alcohols and hydrocarbons Limited dynamic range (10 2 ) Mass sensitive detector 27-8. What is the packing material used in most packed GC columns? 3

Most packing materials are composed of a solid support that is usually a diatomaceous earth particles coated with a stationary phase like OV-x or carbowax. 27-9. How do the following open tubular columns differ? (a) PLOT columns (b) WCOT columns (c) SCOT columns a. A PLOT column is an open tubular column with the interior surface covered with a layer of a porous support. It is used for GSC separations. b. WCOT columns are capillary columns with their inner surfaces coated with a thin film of liquid stationary phase. c. SCOT columns are capillary columns in which a solid support is first affixed to their inner surfaces followed by coating the support with a liquid stationary phase. The amount of the stationary phase used in SCOT columns are much greater than that used in WCOT columns which allows a higher sample capacity of the SCOT columns. 27-10. What are megapore columns? Why are they manufactured? Megapore columns are open tubular columns that have internal diameters greater than 500 µm. They are used in situations where a large sample is to be separated since megapore columns tolerate sample sizes close to packed columns. 27-11. What are the advantages of fused-silica capillary columns compared with glass or metal columns? Fused silica capillary columns are advantageous as compared to glass or metal columns since fused silica columns are easier to manufacture, can be reproducibly drawn to very small diameters and practically any length, and very pure fused silica materials are available which results in very clean columns. FSOT columns are easy to work with in terms of trimming, coiling, etc. 27-12. What properties should the stationary-phase liquid for GC possess? Liquid Stationary Phases should have the following characteristics: Low volatility High decomposition temperature (thermally stable) Chemically inert (reversible interactions with solvent) Chemically attached to support (to prevent bleeding) Appropriate k' and α for solutes to obtain good resolution 4

27-13. Why are gas chromatographic stationary phases often bonded or cross-linked? What do these terms mean? Stationary phases in GLC are usually bonded to solid support or crosslinked in order to prevent bleeding of the stationary phase. Bonding means to covalently attach the stationary phase molecules to solid support while crosslinking means to chemically attach stationary phase molecules to each other, usually by a polymerization process. 27-14. What is the effect of stationary-phase film thickness on gas chromatograms? Stationary phase film thickness has the following effects in GC: a. As film thickness increases, efficiency decreases. b. As film thickness increases, sample capacity increases. c. As film thickness increases, retention increases which allows the separation of highly volatile solutes that have very small and close retention times. 27-15. What are retention indexes? Describe how they are determined. The retention index, was proposed as a parameter for identifying solutes from chromatograms. The retention index for any given solute can be derived from a chromatogram of a mixture of that solute with at least two normal alkanes (chain length >four carbons) having retention times that bracket that of the solute. By definition, the retention index for a normal alkane is equal to 100 times the number of carbons in the compound regardless of the column packing, the temperature, or other chromatographic conditions. The retention index system has the advantage of being based upon readily available reference materials that cover a wide boiling range. The retention index of a compound is constant for a certain stationary phase but can be totally different for other stationary phases. In finding the retention index, a plot of the number of carbons of standard alkanes against the logarithm of the adjusted retention time is first constructed. The value of the logarithm of the adjusted retention time of the unknown is then calculated and the retention index is obtained from the plot. 27-16. What is meant by GC/MS? Why is it important? In GC/MS, the mass spectrometer is coupled to the outlet of the GC column where effluents are ionized and fragmented through the mass spectrometer. The mass spectrometer separates the fragments according to molecular mass and thus provides a full spectrum for each compound (peak in GC), which presents excellent undoubtful identification of compounds. 27-17. A polar compound is gas chromatographed on an SE-30 (very nonpolar) column and then on a Carbowax 20M (very polar column). How will K = C S /C M vary between the two columns? 5

The distribution constant of the polar compound on carbowax 20M will be much greater than the distribution constant of the same polar compound on SE-30. Retention is increased as the polarity of an analyte approaches that of the stationary phase. Therefore, K carbowax will be much greater than K SE-30. 27-18. t R (n-pentane) = 2.16 0.571 = 1.589 log t R (n-pentane) = 0.20112 I (n-pentane) = 500 t R (n-hexane) = 4.23 0.571 = 3.659 log t R (n-hexane) = 0.56336 I (n-hexane) = 600 Slope = (0.56336 0.20112)/(600-500) = 3.622x10-3 Y = b + mx, substitution for pentane gives: 0.20112 = 3.622x10-3 * 500 + b b = -1.609 Now, work for 1-hexene: t R (1-hexene) = 3.15 0.571 = 2.579 log t R (1-hexene) = 0.4115 Substitution in the derived equation gives: 6

0.4115 = 3.622x10-3 * I 1-hexene 1.609 I 1-hexene = 558 27-19. A GC column was operated under the following conditions: column: 1.10 m x 2.0 mm, packed with Chromosorb P; weight of stationary liquid added, 1,40 g; density of liquid, 1.02 g/ml measured outlet flow rate: 25.3 mlimin temperature: room, 21.2 C; column, 102.0 C retention times: air, 18,0 s; methyl acetate, 1.98 min; methyl propionate, 4.16 min; methyl n-butyrate, 7.93 min peak widths of esters at base: 0.19, 0.39, and 0.79, respectively Calculate (a) the retention factor k for each component. (b) selectivity factor, for each adjacent pair of compounds. (c) the average number of theoretical plates and plate height for the column. (d) the resolution for each adjacent pair of compounds.. a. k = (t R t M )/t M k MA = (1.98-0.3)/0.3 = 5.6 k MP = (4.16-0.3)/0.3 = 12.9 k MB = (7.93-0.3)/0.3 = 25.4 b. α MP/MA = k MP /k MA α MP/MA = 12.9/5.6 = 2.3 α MB/MA = 25.4/5.6 = 4.54 α MB/MP = 25.4/12.9 = 1.97 c. N = 16 (t R /W) 2 N MA = 16(1.98/0.19) 2 = 1738 N MP = 16(4.16/0.39) 2 = 1820 N MB = 16(7.93/0.79) 2 = 1612 N = (1738 + 1820 + 1612)/3 = 1723 H = L/N = 110/1723 = 0.064 cm 7

d. R 2,1 = 2(t R2 t R1 )/(W 1 + W 2 ) R MP,MA = 2(4.16-1.98)/(0.19+0.39) = 7.5 R MB,MP = 2(7.93-4.16)/(0.39+0.79) = 6.4 27-20. The stationary-phase liquid in the column described in previous problem was didecylphthalate, a solvent of intermediate polarity. If a nonpolar solvent such as a silicone oil had been used instead, would the retention times for the three compounds be larger or smaller? Why? The esters have an intermediate polarity like the didecylphthalate stationary phase. If a nonpolar stationary phase is used, the retention times of esters will decrease. 7-21. Corrected retention times for ethyl-, n-propyl- and n-butyl alcohols on a column employing a packing coated with silicone oil are 0.69, 1.51, and 3.57 min, respectively. Predict the retention times for the next two members of the homologous series (n-pentyl and n-hexyl alcohols). Plot the logarithm of the retention time versus the number of carbons of alcohols and extend the graph to get the retention times of the unknown alcohols: ' For pentanol (5 carbons) first find Y which is the log of t R time: then find the retention Y = - 0.879 + 0.357*5 8

t R ' = 8.1 For hexanol (6 carbons) first find Y which is the log of t R ' then find the retention time: Y = - 0.879 + 0.357*6 t R ' = 18.3 27-22. What would be the effect of the following on the plate height of a column? (a) Increasing the weight of the stationary phase relative to the packing weight. (b) Decreasing the rate of sample injection. (c) Increasing the injection port temperature. (d) Increasing the flow rate. (e) Reducing the particle size of the packing. (f) Decreasing the column temperature. a. Increasing the weight of stationary phase will increase the stationary phase film thickness which will increase H S and thus decrease efficiency. b. Decreasing rate of sample injection will result in broader peaks due to increased H. c. Effect of increasing injection port temperature depends on the initial value of the injector. If the initial value was inadequately low, increasing the injection port temperature will very much improve efficiency and decrease H. However, if the injector temperature was high enough, further increase in temperature of the injector will have little or no effect on efficiency or H. d. Increasing flow rate above optimum will increase H while increasing flow rates towards optimum will decrease H. e. Reducing d p will decrease H and improves efficiency. f. Decreasing column temperature will decrease the C term and increase the B term of van Deemter equation. Usually, H will increase as column temperature is decreased. 9

27-23. Calculate the retention index of the following compounds: Compound T R - t M n-propane 1.29 n-butane 2.21 n-pentane 4.10 n-hexane 7.61 n-heptane 14.08 n-octane 26.11 Toluene 16.32 2-Butene 2.67 n-propanol 7.60 Methylethylketone 8.40 Cyclohexane 6.94 n-butanol 9.83 First plot the log t R versus the number of carbons in n-alkanes as required by Kovat s retention index determination. Then find the retention index of the different compounds: From a the assumption of Kovat, the retention index for each compound is equal to the number of carbons times 100. Sample calculation for toluene: applying the straight line equation, we get: We know the adjusted retention time, therefore find log t R and substitute for Y then find x. The retention index is equal to x*100 1.213 = -0.697 + 0.264 * x x = 7.23 10

I toluene = 7.23 * 100 = 723 Other compounds are calculated in the same manner: Compound Retention Index n-propane 300 n-butane 400 n-pentane 500 n-hexane 600 n-heptane 700 n-octane 800 Toluene 723 2-Butene 426 n-propanol 598 Methylethylketone 614 Cyclohexane 583 n-butanol 640 11