NEC EXPRESS5800/R320b-M4 Configuration Guide

Similar documents
NEC EXPRESS5800/R320d-E4 Configuration Guide

NEC EXPRESS5800/R320c-E4 Configuration Guide

NEC Express5800/T110f-E System Configuration Guide

How To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X

NEC Express5800/R120f-2M System Configuration Guide

System Configuration and Order-information Guide ECONEL 100 S2. March 2009

NEC Express5800/E120d-1 Configuration Guide

NEC Express5800/R120f-1M System Configuration Guide

Highly Scalable Server for Many Possible Uses. MAXDATA PLATINUM Server 3200 I

Chapter 5 Cubix XP4 Blade Server

TS500-E5. Configuration Guide

High Performance 2U Storage Server. Mass Storage Capacity in a 2U Chassis

High Performance 1U Server. High Performance 1U Storage Server. Front Parallel CPU Design features better cooling

Mini server, BIG performance AC100

FUJITSU Enterprise Product & Solution Facts

DD670, DD860, and DD890 Hardware Overview

Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server

Scout 1U Rackmount Computer

Cisco 7816-I5 Media Convergence Server

New levels of efficiency and optimized design. The latest Intel CPUs. 2+1 expandability in UP 1U

Optimized dual-use server and high-end workstation performance

Acer AT110 F2 Specifications

LaCie 12big Rack Network

QuickSpecs. HP 200 G1 Microtower Business PC. HP 200 G1 Microtower Business PC. Overview

Data Sheet Fujitsu PRIMERGY CX122 S1 Cloud server unit for PRIMERGY CX1000

IBM Europe Announcement ZG , dated March 11, 2008

MESOS CB220. Cluster-in-a-Box. Network Storage Appliance. A Simple and Smart Way to Converged Storage with QCT MESOS CB220

Servers, Clients. Displaying max. 60 cameras at the same time Recording max. 80 cameras Server-side VCA Desktop or rackmount form factor

HP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN

Application Server V240 Platform

QuickSpecs. HP IP Console Switch with Virtual Media Overview

System x3650 Type 7979

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server

Data Sheet Fujitsu PRIMERGY BX900 S1 Blade Server

HP Server Console Switch with Virtual Media Overview

Fujitsu PRIMERGY BX600 S3 Blade Server

Acer AR180 F1 specifications

QuickSpecs. Models HP Server Console Switches

Power Redundancy. I/O Connectivity Blade Compatibility KVM Support

GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay

U.S. Product Specifications Reference PSREF. Version 483, December ThinkServer Servers. Visit for the latest version

Express5800/320Lb System Release Notes

QUESTIONS & ANSWERS. ItB tender 72-09: IT Equipment. Elections Project

Cisco MCS 7825-H2 Unified CallManager Appliance

TrueAlarm Fire Alarm Systems

Cisco MCS 7825-H3 Unified Communications Manager Appliance

Cisco NAC Appliance Hardware Platforms

HUAWEI TECHNOLOGIES CO., LTD. HUAWEI FusionServer X6800 Data Center Server

Server Management. (August 8, 2015) SERVER MANAGEMENT

QuickSpecs. HP 280 G1 Microtower Business PC. Overview

Minimum Hardware Specifications Upgrades

Terms of Reference Microsoft Exchange and Domain Controller/ AD implementation

Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server

System Release Notes Express5800/320LB System Release Notes

Data Sheet FUJITSU Server PRIMERGY TX1310 M1 Tower Server

Data Sheet FUJITSU Server PRIMERGY TX100 S3p Tower Server

INDIAN INSTITUTE OF TECHNOLOGY KANPUR Department of Mechanical Engineering

DCS Data and communication server

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

5520UR 00UR 00UR 625UR 625URSAS 00UR URBRP 600URLX 625URLX

Cisco MCS 7816-I3 Unified Communications Manager Appliance

Interface Adapters PS/2 Interface Adapter 1 pack B21 PS/2 Interface Adapter 8 pack B21 USB Interface Adapter 1 pack B21

HUAWEI Tecal E6000 Blade Server

QuickSpecs. Models. HP StorageWorks Modular Smart Array 50 Enclosure. HP StorageWorks Modular Smart Array 50 Enclosure. Overview

VTrak SATA RAID Storage System

ACER INC. VERITON M200 QUICK SPEC

QuickSpecs. HP Compaq t5525 Thin Client. Overview

Data Sheet FUJITSU Server PRIMERGY TX100 S3p Tower Server

ROSA Server MKVI. A Complete, Powerful Solution

Fujitsu PRIMERGY Servers Portfolio

QuickSpecs. HP 285 Pro G1 Microtower Business PC. Overview

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure

SUN FIRE X4170 SERVER

Functionality. Overview. Broad Compatibility. 125 TB LTO Archive System Fast Robotics for Restore Intensive Applications

ThinkServer TS140 - Overview

HP recommended configurations for Microsoft Exchange Server 2013 and HP ProLiant Gen8 with direct attached storage (DAS)

Cisco Unified Computing System Hardware

Phone and Fax: (717) or Send to- On the Internet at

A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing.

Tipos de Máquinas. 1. Overview x3550 M2. Features X550M2

Cisco MCS 7845-I2 Unified Communications Manager Appliance

Pioneer DreamMicro. Blade Server S75 Series

Network Security Appliance. Overview Performance Platform Mainstream Platform Desktop Platform Industrial Firewall

Intel Server Chassis P4304XXSHCN/P4304XXSFCN/P4000XXSFDR

Monthly Specification Update

1U µtca.4 Chassis with 2 AMC Slots, PCIe Gen 3 VT816

Data Sheet Fujitsu PRIMERGY TX120 S3p Server

APACHE HADOOP PLATFORM HARDWARE INFRASTRUCTURE SOLUTIONS

XenData Product Brief: SX-250 Archive Server for LTO

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

DD160 and DD620 Hardware Overview

Data Sheet FUJITSU Server PRIMERGY TX1310 M1 Tower Server

How To Buy An Fujitsu Primergy Bx400 S1 Blade Server

Data Sheet. Dual Socket Quad-Core AMD Opteron 2000 series-based rack server - High-performance, low-priced standard server

The Leading KVM Switch Solutions Provider, ATEN. 40-Port KVM Over the NET - 1 local / 4 remote user access

EVGA Z97 Classified Specs and Initial Installation (Part 1)

Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure

PRICE LIST Euros: CY 2011 Q4 IT PLATFORM SOLUTIONS

Brainlab Node TM Technical Specifications

Transcription:

NEC EXPRESS5800/R320b-M4 Configuration Guide Windows Server 2008 R2 model Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC EXPRESS5800 server. October 2012 Revision 8.0 NEC Corporation

Contents TECHNICAL SPECIFICATION... 3 Key Features... 3 Specification... 3 EXTERNAL VIEWS... 5 Front and Rear Views... 5 Dimensions (mm)... 7 CONFIGURATION DIAGRAM... 8 SERVER CONFIGURATION... 9 1 Base Models... 9 2 2nd Processor... 9 3 Memory... 9 4 Internal Hard Disk Drives... 10 5 Optical Drive... 11 6 PCI Card... 11 7 Other Add-in Components... 11 7.1 Input Devices... 11 8 Add-on Components... 12 8.1 17-inch LCD Console Drawer... 12 8.2 KVM Switch... 12 8.3 Flash FDD... 12 8.4 Operating System... 12 8.5 Tower Conversion Kit... 13 8.6 External Tape Drives... 13 REFERENCES... 15 Note for Ordering... 15 Server Management... 15 Supported PCI Cards and Installable Slots... 16 Notes for using Hyper-V... 17 Copyright Notice and Liability Disclaimer... 18 REVISION HISTORY... 19 NEC Corporation Revision 8.0, October 2012 2

Technical Specification Key Features Fault tolerant technology based on GeminiArchitecture TM Full manageability by integrated EXPRESSSCOPE Engine 2 High performance with the latest Intel Xeon processor 5600 series Up to 96GB of high speed DDR3-1333 memory Specification Model R320b-M4 N8800-154F Processor Type Intel Xeon processor X5670 Chipset Clock speed Logical Number of Processors Cache Cores and Threads 2.93 GHz 1 or 2 12 MB 6C / 12T Intel 5500 Chipset with GeminiEngine TM Memory Type DDR3-1333 ECC Registered DIMM Logical Standard Capacity Logical Maximum Capacity Memory protection 0GB Internal Storage Standard Capacity 0GB Expansion Slots [free] Maximum Capacity Disk Controller RAID Hot Plug 96GB (12 x 8GB) ECC, x4 SDDC 4.8 TB (8 x 600GB) SAS: 3Gb/s (Standard) SAS : RAID 1 (Standard) Supported Optical Disk Drive DVD Super Multi drive 1 Optical Drive Bays [free] Logical Disk Drive Bays [free] Standard 1 [0] 8 [8] Total: 4 slots available 2[2] x PCIe 2.0 x4 (x8 connector) 2[2] x PCIe 1.0 x4 (x8 connector) Video Controller (VRAM) Integrated in Server Management Controller (32MB) Interfaces Resolution / Color Supported Server Management EXPRESSSCOPE Engine 2 Power Supply Power Consumption (Max. Config, Operating) 800 x 600 / 16.7M, 1024 x 768 / 16.7M, 1280 x 1024 / 65K 1 x VGA (15-pin mini D-sub, 1 x rear per system) 4 x USB (1 x front, 3 x rear per system) 4 x 1000BASE-T LAN connector (1000BASE-T / 100BASE-TX / 10BASE-T, RJ-45, 2 x rear per CPU/IO module) 2 x Management LAN connector (100BASE-TX / 10BASE-T, RJ-45, 1 x rear per CPU/IO module) 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz 1,400 VA / 1,390 Watt NEC Corporation Revision 8.0, October 2012 3

Model R320b-M4 1 Dimensions (W x D x H ) Weight (Minimum / Maximum) Temperature, Relative Humidity (non-condensing) Regulatory and Safety Operating Systems Writing software is not provided for this DVD drive. 483.0 x 736.0 x 178 mm / 19.0 x 29.0 x 7.0 in (4U) 46 kg / 52 kg, 101.41 lbs. / 114.64 lbs. Operating: 10 to 35 C / 50 to 95 F, 20 to 80% Non-Operating: -10 to 55 C / 14 to 131 F, 20 to 80% FCC, CE, BSMI, CCC, UL, CB, RoHS Microsoft Windows Server 2008 R2 Enterprise NEC Corporation Revision 8.0, October 2012 4

External Views Front and Rear Views Front View A B C D E F G H I J A B K L M N O P Q R S T U Legend A. Drive Bays L. CPU Fault LED B. UID Button M. Memory Fault LED C. DVD Super Multi Drive N. Module Power LED D. System Power LED O. SAFE TO PULL LED E. System Status LED P. PRIMARY LED F. System FT LED Q. IO Module Fault LED G. UID LED R. Fan Fault LED H. USB Connector S. PSU Fault LED I. Pull-out Tab T. DC Power Fault LED J. Power Button U. Temperature Fault LED K. Module ID LED NEC Corporation Revision 8.0, October 2012 5

Rear View B C D A E F F G H I E Legend 1 A. USB Connectors F. AC Inlet B. Management LAN Connector G. Serial Port Connector 1 C. Module ID LED H. VGA Connector D. Data LAN Connectors I. PCI Slots (Full-Height) E. PCI Slots (Low-Profile) For service personnel only. NEC Corporation Revision 8.0, October 2012 6

Dimensions (mm) Rack mount 178 736 450 483 689 Tower Conversion (Optional) 220 804 592 327 NEC Corporation Revision 8.0, October 2012 7

CONFIGURATION GUIDE NEC EXPRESS5800/R320b-M4 / Windows Server 2008 R2 model Configuration Diagram Server CHASSIS REAR Optical Drive Bay CHASSIS FRONT Backplane CPU/IO Module CPU/IO Module CPU/IO module #0 : CHASSIS REAR DIMM #1 DIMM #2 DIMM #3 DIMM #4 DIMM #5 DIMM #6 CHASSIS FRONT PCI Riser PCIe 2.0 x4 (x8 socket) FH Processor Processor Cooling Fan #1 - #4 Drive Cage PCIe 1.0 x4 (x8 socket) LP PCIe 1.0 x4 (x8 socket) LP DIMM #7 DIMM #8 DIMM #9 DIMM #10 DIMM #11 DIMM #12 Power Supply CPU/IO module #1 : DIMM #1 DIMM #2 DIMM #3 DIMM #4 DIMM #5 DIMM #6 PCI Riser PCIe 2.0 x4 (x8 socket) FH Processor Processor Cooling Fan #1 - #4 Drive Cage PCIe 1.0 x4 (x8 socket) LP PCIe 1.0 x4 (x8 socket) LP DIMM #7 DIMM #8 DIMM #9 DIMM #10 DIMM #11 DIMM #12 Power Supply Legend: Minimum required components Standard components NEC Corporation Revision 8.0, October 2012 8

Server Configuration 1 Base Models Product Name / Description NEC EXPRESS5800/R320b-M4 no RAM, no 2.5-inch HDD Including: Intel Xeon Processor X5670, 1 x DVD Super Multi, EXPRESSBUILDER DVD, Active Upgrade TM DVD N8800-154F 2 2nd Processor Available logical sockets: 1 Product Name / Description Intel Xeon Processor X5670 2nd Processor Kit : 2.93 GHz / 6C-12T / 12 MB, 2 processors included N8801-043 3 Memory Available logical slots: 6 per processor Product Name / Description 2GB DDR3-1333 REG Memory Kit : 2 x 2GB DIMM included N8802-050 12GB DDR3-1333 REG Memory Kit : 2 x 3 x 4GB DIMM included N8802-051 24GB DDR3-1333 REG Memory Kit : 2 x 3 x 8GB DIMM included N8802-046 NOTE: Minimum one memory kit must be installed. 4GB or more of main memory is recommended to use Hyper-V. Memory Configuration Guideline See the table below for the number of memory kits required in accordance with logical main memory size and number of logical processors. Memory configurations which are not listed below are not supported in the system. Number of Logical Processors Logical Main Memory Size Number of Memory Kits Required 2GB 12GB 24GB 1 2GB 1 - - 4GB 2 - - 6GB 3 - - 8GB 4 - - 10GB 5 - - 12GB 6 - - - 1-24GB - 2 - - - 1 36GB - 1 1 48GB - - 2 NEC Corporation Revision 8.0, October 2012 9

Number of Logical Processors Logical Main Memory Size Number of Memory Kits Required 2GB 12GB 24GB 2 2GB 1 - - 4GB 2 - - 6GB 3 - - 8GB 4 - - 10GB 5 - - 12GB 6 - - 16GB 8 - - 20GB 10 - - 24GB 12 - - - 2-36GB 6 2-48GB - 4 - - - 2 72GB - 2 2 96GB - - 4 4 Internal Hard Disk Drives Available bays: 8 Product Name / Description 146.5GB 10K Hot Plug 2.5-inch SAS HDD : 1 x 146.5GB N8850-042 300GB 10K Hot Plug 2.5-inch SAS HDD : 1 x 300GB N8850-043 600GB 10K Hot Plug 2.5-inch SAS HDD : 1 x 600GB N8850-044 73.2GB 15K Hot Plug 2.5-inch SAS HDD : 1 x 73.2GB N8850-045 146.5GB 15K Hot Plug 2.5-inch SAS HDD : 1 x 146.5GB N8850-046 NOTE: Hard drives must be installed in identical pairs to configure RAID 1. NEC Corporation Revision 8.0, October 2012 10

Required System Disk Capacity See the table below for minimum required system disk capacity to store whole memory dump data. It is recommended to install hard drives providing the minimum required system disk capacity to reduce the time to resynchronize after a hard drive replacement. Memory Size Required System Disk Capacity Up to 16GB 20GB to 36GB 48GB to 96GB 73.2GB 146.5GB 300GB 5 Optical Drive Available bays: 1 Product Name / Description Internal DVD Super Multi Drive : 1 x DVD Super Multi drive, not including writing software (Standard) 6 PCI Card Category Product Name / Description LAN Controller Fibre Channel Controller SAS Controller NOTE: 1000BASE-T 2ch board kit : 2 x GbE NIC Intel Gigabit ET Dual Port Server Adapter Fibre Channel board kit (8Gbps) : 2 x FC Controller QLogic QLE2560-SP 8Gbps Fibre Channel Adapters SAS Controller : 1 x SAS Controller LSI SAS3442E-R Host Bus Adapter NOTE: Up to one controller per module N8804-009 N8803-038 N8803-037 For supported NEC Storage products to connect with N8803-038, contact your sales representative or refer to the NEC Storage WEB site. (http://www.nec.com/global/prod/storage/) 7 Other Add-in Components 7.1 Input Devices Category Product Name / Description Keyboard USB Keyboard N8870-002AF Mouse USB Optical Wheel Mouse N8870-012 Cable USB cable : 1.5m USB extension cable K410-177(1A) NEC Corporation Revision 8.0, October 2012 11

8 Add-on Components 8.1 17-inch LCD Console Drawer Category Product Name / Description Drawer w/ KVM Switch Drawer w/o KVM Switch Drawer Cable Drawer 8.2 KVM Switch 17inch LCD Console Unit (1U/8port) 17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port KVM switch, 1U height Switch Unit Connection Cable Set (USB, 1.8m) 1.8 m, 1 x 15-pin mini D-SUB to 1 x 15-pin mini D-SUB / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 3m) 3 m, 1 x 15-pin mini D-SUB to 1 x 15-pin mini D-SUB / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 5m) 5 m, 1 x 15-pin mini D-SUB to 1 x 15-pin mini D-SUB / 1 x 4-pin USB A 17inch LCD Console Unit 1U 17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height, 4-pin USB B to 4-pin USB A cable 2m, PS/2 Y-splitter cable 2m, 15-pin mini D-sub VGA cable 2m N8143-77F K410-118(1A) K410-118(03) K410-118(05) N8143-76F Category Product Name / Description KVM Switch Server Switch Unit (8 server) 1U USB 8 port KVM switch N8191-12F Cable KVM Switch Unit Connection Cable Set (USB,1.8m) 1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,3m) 3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,3m) 5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Cascading Switch Unit Connection Cable 1.8 m 1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2 8.3 Flash FDD Order the Flash FDD if you need to prepare an alternative for a floppy drive. Product Name / Description Flash FDD USB flash emulating USB floppy disk, Native capacity 1.44 MB K410-118(1A) K410-118(03) K410-118(05) K410-119(1A) N8160-86 8.4 Operating System Product Name / Description Microsoft Windows Server 2008 R2 Enterprise (1-2 Processor, 25CAL Version): English Chinese Traditional Chinese Simplified Korean UL0999-436EN UL0999-436CT UL0999-436CS UL0999-436KR NEC Corporation Revision 8.0, October 2012 12

8.5 Tower Conversion Kit Product Name / Description Tower Conversion Kit 23 inch height pedestal with front bezel N8843-003 8.6 External Tape Drives 8.6.1 Tape Drive Selection Refer to the section in accordance with your type of tape drives. LTO LTO2 SAS Refer to 8.6.2 LTO3 SAS Refer to 8.6.2 LTO4 SAS Refer to 8.6.2 8.6.2 LTO / SAS Category Product Name / Description Controller Required External Cable Required Tape Enclosure Required Power Module Recommended Internal Cable Required Drive 2 bays available SAS Controller LSI SAS3442E-R Host Bus Adapter External SAS cable 2 m, 1 x SFF-8470 SAS to 1 x SFF-8088 Mini-SAS 2U Tape Drive Enclosure 4 x 5-inch media bays, two internal SAS cables included Power Supply 1 x non-hot plug power supply unit for redundant configuration Internal SAS cable 2 m, for 2U Tape Drive Enclosure internal connection NOTE: Required when three or more SAS connections (including other general purpose servers) to the N8141-59F Internal LTO (SAS) LTO2, Half height, Native capacity 200GB Internal LTO (SAS) LTO3, Half height, Native capacity 400GB Internal LTO (SAS) LTO4, Half height, Native capacity 800GB Internal LTO (SAS) LTO5, Half height, Native capacity 1500GB N8803-037 K410-168(02) N8141-59F N8181-54F K410-249(00) N8151-101 N8151-102 N8151-90 N8151-103 NEC Corporation Revision 8.0, October 2012 13

8.6.3 Notes for double backup In a single backup configuration, in case a CPU/IO module or backup device fails, backup is not possible until the failed part is repaired or replaced. If this does not meet your system requirements, consider a double backup configuration. Refer to the following notes on double backup configuration. When configuring two sets of a SAS controller, a SAS cable and a backup device, two backup devices are recognized separately by the OS. When scheduling an automatic backup job, make a job for each backup device so that the other backup device can backup in case one device fails. With BrightStor ARCserve Backup, backup is not executed if you enter an asterisk (*) in the group box under the destination tab when defining a job. Be sure to create two backup jobs by correctly selecting the device group for the group box, and entering an asterisk (*) or the name of the media in the media box. 8.6.4 Supported backup software See the table below for the supported backup software on NEC EXPRESS5800/R320c. Tape drive Product Name / Description Internal LTO (SAS) LTO2, Half height, Native capacity 200 GB Internal LTO (SAS) LTO3, Half height, Native capacity 400 GB Internal LTO (SAS) LTO4, Half height, Native capacity 800 GB Internal LTO (SAS) LTO5, Half height, Native capacity 1.5 TB Backup software ARCserve ARCserve Backup Exec ARCserve r15 ARCserve r16 Backup Exec 2010 WS2008R2 WS2008R2 WS2008R2 N8151-101 *a1 *a1 *b2 N8151-102 *a1 *a1 *b2 N8151-90 *a1 *a1 *b3 N8151-103 *a1 *a1 *b2 *a1: Do not disable the tape driver on the device manager. *b2: Do not install the Symantec driver. Apply the driver which comes with the tape drive. *b3: Use the latest driver which can be downloaded from the Symantec website NOTE: Disaster Recovery Option is not supported on the ft server system. It is not supported to backup from NEC Express5800/ft series to a backup device directly using NetBackup. However, NEC Express5800/ft series can be a backup-client machine of NetBackup. NEC Corporation Revision 8.0, October 2012 14

References Note for Ordering Part numbers provided may be needed to modify by country/region when you order the products. For example, the operable part number for N8100-1738F in EMEA is N8100-1738F-O, adding "-O", the country-specific identifier for EMEA, after the part number. Please consult your sales representative for your country identifier. Server Management The EXPRESSSCOPE Engine 2, integrated into the server, provides superior remote control and system management features listed in the table below. 2 Hardware monitoring Boot monitoring Alerting Temperature/voltage/power/ fan /degeneration (memory/hard drive) Hardware event log collection Booting, BIOS/POST stall, OS stall, shutdown HW error, Boot error and OS panic (by SNMP, E-Mail) Remote console POST/BIOS setup, DOS utility (via LAN) Panic screen, Boot screen Text-based screen (OS console) - GUI-based screen (OS console) Remote control Remote reset - (via LAN) power on-off/ dump OS shutdown Remote media (CD/DVD/FD) Server Management Command Line Protocol (DMTF compliant) Remote control via Web browser (without dedicated app) Remote batch 1 Scheduling (without UPS) 1 Others Set automatic IP address via DNS/DHCP Remote wakeup Wake On LAN Centralized management Monitoring of multiple servers Control of multiple servers 1 Industry standard IPMI 2.0 DianaScope is required. NEC Corporation Revision 8.0, October 2012 15

Supported PCI Cards and Installable Slots Product Name Slots Notes Slot # : #1 #2 #3 #4 PCI Slot: x4 x4 x4 x4 Card height: LP LP FH FH Slot type: x8 x8 x8 x8 N8804-009 1000BASE-T 2ch board kit N8803-037 SAS Controller Max. 1 N8803-038 Fibre Channel board kit - - NEC Corporation Revision 8.0, October 2012 16

Notes for using Hyper-V Brief system interruption during synchronization process In the synchronization process of CPU modules, a memory copy is performed to duplex memory on both CPU modules. Most of the memory area can be copied without interrupting the system through the so-called brownout copy method, and just a small portion requires the system to stop. However with Hyper-V, the system cannot use the brownout copy method. Therefore, the system does not respond for a longer period of time during the synchronization process of the CPU modules than without Hyper-V. See the table below for the reference values of interruption during re-synchronization of CPU/IO modules in a Hyper-V system. It is recommended that your system design take the interruption into account. Logical Main Memory Size 4GB 12GB 24GB 48GB 96GB 4 sec 8 sec 15 sec 29 sec 57 sec About Guest OS Guest operating systems supported on NEC Express5800/ft series are the same as other general purpose servers. Refer to the Microsoft web site for Supported Guest Operating Systems on Hyper-V. Backup When using Hyper-V on a FT server, prepare a separate server for backup in the same way as for other general purpose servers with Hyper-V. For backup patterns, refer to each backup software company's web site. NEC ESMPRO Agent For monitoring guest operating systems, NEC ESMPRO Agent for Guest OS is required. Contact your sales representative for this software. Active Upgrade Teams assigned to the virtual network by Hyper-V Virtual Network Manager cannot be used in Active Upgrade. To use Active Upgrade, at least two teams are required. NEC Corporation Revision 8.0, October 2012 17

Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice. Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a trademark of Linus Torvalds. Red Hat is a registered trademark of Red Hat, Inc. in the U.S. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less. NEC Corporation Revision 8.0, October 2012 18

Revision History Revision Date Description 8.0 2012.10. 3 N8141-41F deleted (EOL) N8141-59F 2U Tape Drive Enclosure added N8151-77 (LTO4) deleted (EOL) Backup software support matrix added K410-119(1A) (cable for KVM switch cascading) added Description of K410-168(02) corrected 7.2 2012.5.23 SCSI Controller and related products deleted (EOL) 17-inch LCD Console Drawer and KVM Switch s changed 7.1 2012.4.23 Keyboard corrected Mouse changed from N8170-22 to N8870-012 7.0 2011.11.25 Document form changed. Memory P/N changed. N8151-103 (LTO5) added in 8.6 External Tape Drives 6.0 2011.7.20 Memory description corrected. N8870-010A is deleted. (EOL) 5.0 2011.4.15 Supported mouse added. 4.0 2010.11.29 FDD description removed because of EOL. 3.0 2010.11.1 Notes for using Hyper-V updated. (Non-responding time of R320a-E4 with 96GB memory) 2.0 2010.10.21 Memory capacity of R320a-E4 corrected. 1.0 2010.10.19 Initial release NEC Corporation Revision 8.0, October 2012 19