Assessment of Accuracy and Precision



Similar documents
Measurement and Calibration

Calibration of Volumetric Glassware

Calibration of Glassware

The volume of a penny will be calculated from its mass and density.

Calibration of Volumetric Glassware

Experiment 1: Measurement and Density

Glassware Calibration Guidelines Laura B. Secor and Dwight R. Stoll, 02/01/2012 Adapted from National Bureau of Standards Document

The introduction of your report should be written on the on the topic of the role of indicators on acid base titrations.

Density Determinations and Various Methods to Measure

Acid Base Titrations

COMMON LABORATORY APPARATUS

EXPERIMENT 9 Evaluation of the Universal Gas Constant, R

Laboratory Exercise: The Precision of Volume Measurements

Lab 25. Acid-Base Titration and Neutralization Reactions: What Is the Concentration of Acetic Acid in Each Sample of Vinegar?

EXPERIMENT 10: TITRATION AND STANDARDIZATION

UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE ABSORPTION OF CARBON DIOXIDE INTO WATER

THE LABORATORY NOTEBOOK

Significant Figures, Propagation of Error, Graphs and Graphing

Reaction of Magnesium with Hydrochloric Acid (Gas Laws) Chemicals Needed:

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

The Analytical Balance

(1) Hydrochloric acid reacts with sodium hypochlorite to form hypochlorous acid: NaOCl(aq) + HCl(aq) HOCl(aq) + NaCl(aq) hypochlorous acid

Vitamin C Content of Fruit Juice

Density Determinations

Ascorbic Acid Titration of Vitamin C Tablets This lab will be completed individually! Make sure you come prepared!

FAJANS DETERMINATION OF CHLORIDE

PART I: PREPARATION OF SOLUTIONS AND STANDARDIZATION OF A BASE

experiment5 Understanding and applying the concept of limiting reagents. Learning how to perform a vacuum filtration.

Esterification Method 1 Method to 2800 mg/l (as acetic acid) Reagent Solution

Acid Base Titration: ph Titration Curve

American Association for Laboratory Accreditation

Dissolving of sodium hydroxide generates heat. Take care in handling the dilution container.

FederalDemocratic RepublicofEthiopia

Determining the Identity of an Unknown Weak Acid

Solutions and Dilutions

Pre-Lab Notebook Content: Your notebook should include the title, date, purpose, procedure; data tables.

Understanding Analytical Chemistry (Weighing, Mixing, Measuring and Evaluating)

Analyzing the Acid in Vinegar

How To Test A Titrette And Digital Burette

Partner: Jack 17 November Determination of the Molar Mass of Volatile Liquids

A Beer s Law Experiment

EDTA Titrations 1: Standardization of EDTA and Analysis of Zinc in a Supplement Tablet. by Professor David Cash. September, 2008

Related concepts Kohlrausch s law, equivalent conductivity, temperature dependence of conductivity, Ostwald s dilution law.

Spreadsheets and Laboratory Data Analysis: Excel 2003 Version (Excel 2007 is only slightly different)

The Determination of Acid Content in Vinegar

CSUS Department of Chemistry Experiment 8 Chem.1A

MOISTURE (Karl Fischer, Buffered)

Estimating Weighing Uncertainty From Balance Data Sheet Specifications

Determination of Citric Acid in Powdered Drink Mixes

Color, True and Apparent

Color, True and Apparent

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

AP Physics 1 and 2 Lab Investigations

To determine the equivalence points of two titrations from plots of ph versus ml of titrant added.

Stoichiometry Limiting Reagent Laboratory. Chemistry 118 Laboratory University of Massachusetts, Boston

Standard Operating Procedure for the Determination of Total and Total Dissolved Solids CCAL 13A.2

EXERCISE # 1.Metric Measurement & Scientific Notation

Gravimetric determination of pipette errors

Coordination Compounds with Copper (II) Prelab (Week 2)

Mouse Insulin ELISA. For the quantitative determination of insulin in mouse serum and plasma

Experiment 13H THE REACTION OF RED FOOD COLOR WITH BLEACH 1

Apparatus error for each piece of equipment = 100 x margin of error quantity measured

Use of Micropipettes

Determination of Moisture Content

Analysis of Vitamin C Using Iodine. Introduction

TITRATION CURVES, INDICATORS, AND ACID DISSOCIATION CONSTANTS

INTERNATIONAL OLIVE COUNCIL

Quality Assurance/Quality Control in Acid Deposition Monitoring

PERCENT ACETIC ACID IN VINEGAR EXPERIMENT 15

Exp 13 Volumetric Analysis: Acid-Base titration

Determination of the Amount of Acid Neutralized by an Antacid Tablet Using Back Titration

Stoichiometry Limiting Reagent Laboratory. Chemistry 118 Laboratory University of Massachusetts, Boston

Volumetric Analysis. Lecture 5 Experiment 9 in Beran page 109 Prelab = Page 115

WHP Operations and Methods - July Dissolved Oxygen

18 Conductometric Titration

Experiment 3 Limiting Reactants

Apr 17, 2000 LAB MANUAL PARTICLE SIZE ANALYSIS OF SOILS AASHTO Designation T 88 (Mn/DOT Modified)

Calcium Analysis by EDTA Titration

ph and Acidity in Wine and Fruit Juice


Concentrations and Dilutions of Food Dyes

and Drug Administration/Office of Regulatory Affairs (FDA/ORA) laboratories.

GMP 11. Good Measurement Practice for Assignment and Adjustment of Calibration Intervals for Laboratory Standards

STANDARDIZATION OF A SODIUM HYDROXIDE SOLUTION EXPERIMENT 14

Balance Accuracy. FlexiWeigh

Standard Test Method for Consistency of Paints Measuring Krebs Unit (KU) Viscosity Using a Stormer-Type Viscometer 1

Investigation M3: Separating Mixtures into Component Parts

Neutralizing an Acid and a Base

Determining Equivalent Weight by Copper Electrolysis

ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE

Determination of the Mass Percentage of Copper in a Penny. Introduction

The Molar Mass of a Gas

Determination of Insoluble Solids in Pretreated Biomass March 2008 Material

INVESTIGATION OF FALLING BALL VISCOMETRY AND ITS ACCURACY GROUP R1 Evelyn Chou, Julia Glaser, Bella Goyal, Sherri Wykosky

Phosphorus, Reactive (Orthophosphate)

ph: Measurement and Uses

Experiment #2: Determining Sugar Content of a Drink. Objective. Introduction

Evaluation copy. Titration of a Diprotic Acid: Identifying an Unknown. Computer

Transcription:

2 chapter Assessment of Accuracy and Precision S.S. Nielsen, Food Analysis Laboratory Manual, Food Science Texts Series, DOI 10.1007/978-1-4419-1463-7_2, Springer Science+Business Media, LLC 2010 9

Chapter 2 Assessment of Accuracy and Precision 11 INTRODUCTION Background Volumetric glassware, mechanical pipettes, and balances are used in many analytical laboratories. If the basic skills in the use of this glassware and equipment are mastered, laboratory exercises are easier, more enjoyable, and the results obtained are more accurate and precise. Measures of accuracy and precision can be calculated based on the data generated, given the glassware and equipment used, to evaluate the skill of the user as well as the reliability of the instrument and glassware. Determining mass using an analytical balance is the most basic measurement made in an analytical laboratory. Determining and comparing mass is fundamental to assays such as moisture and fat determination. Accurately weighing reagents is the first step in preparing solutions for use in various assays. Accuracy and precision of the analytical balance are better than for any other instrument commonly used to make analytical measurements, provided the balance is properly calibrated, and the laboratory personnel use proper technique. With proper calibration and technique, accuracy and precision are limited only by the readability of the balance. Repeatedly weighing a standard weight can yield valuable information about the calibration of the balance and the technician s technique. Once the performance of the analytical balance and the technician using it has been proven to be acceptable, determination of mass can be used to assess the accuracy and precision of other analytical instruments. All analytical laboratories use volumetric glassware and mechanical pipettes. Mastering their use is necessary to obtain reliable analytical results. To report analytical results from the laboratory in a scientifically justifiable manner, it is necessary to understand accuracy and precision. A procedure or measurement technique is validated by generating numbers that estimate their accuracy and precision. This laboratory includes assessment of the accuracy and precision of automatic pipettors. An example application is determining the accuracy of automatic pipettors in a research or quality assurance laboratory, to help assess their reliability and determine if repair of the pipettors is necessary. Laboratory personnel should periodically check the pipettors to determine if they accurately dispense the intended volume of water. To do this, water dispensed by the pipettor is weighed, and the weight is converted to a volume measurement using the appropriate density of water based on the temperature of the water. If replicated volume data indicate a problem with the accuracy and/or precision of the pipettor, repair is necessary before the pipettor can be reliably used again. It is generally required that reported values minimally include the mean, a measure of precision, and the number of replicates. The number of significant figures used to report the mean reflects the inherent uncertainty of the value, and it needs to be justified based on the largest uncertainty in making the measurements of the relative precision of the assay. The mean value is often expressed as part of a confidence interval (CI) to indicate the range within which the true mean is expected to be found. Comparison of the mean value or the CI to a standard or true value is the first approximation of accuracy. A procedure or instrument is generally not deemed inaccurate if the CI overlaps the standard value. Additionally, a CI that is considerably greater than the readability indicates that the technician s technique needs improvement. In the case of testing the accuracy of an analytical balance with a standard weight, if the CI does not include the standard weight value, it would suggest that either the balance needs calibration or that the standard weight is not as originally issued. Accuracy is sometimes estimated by the relative error (%E rel ) between the mean analysis value and the true value. However, %E rel only reflects tendencies, and in practice is often calculated even when there is no statistical justification that the mean and true value differ. Also, note that there is no consideration of the number of replicates in the calculation of %E rel, suggesting that the number of replicates will not affect this estimation of accuracy to any large extent. Absolute precision is reflected by the standard deviation, while relative precision is calculated as the coefficient of variation (CV). Calculations of precision are largely independent of the number of replicates, except that more replicates may give a better estimate of the population variance. Validation of a procedure or measurement technique can be performed, at the most basic level, as a single trial validation, as is described in this laboratory that includes estimating the accuracy and precision of commonly used laboratory equipment. However, for more general acceptance of procedures, they are validated by collaborative studies involving several laboratories. Collaborative evaluations are sanctioned by groups such as AOAC International, AACC International, and the American Oil Chemists Society (AOCS). Such collaborative studies are prerequisite to procedures appearing as approved methods in manuals published by these organizations. Reading Assignment Literature on how to properly use balances, volumetric glassware, and mechanical pipettes.

12 Chapter 2 Assessment of Accuracy and Precision Nielsen, S.S. 2010. Introduction to food analysis. Ch. 1, in Food Analysis, 4th ed. S.S, Nielsen (Ed.), Springer, New York. Smith, J.S. 2010. Evaluation of analytical data. Ch. 4, in Food Analysis, 4th ed. S.S. Nielsen (Ed.), Springer, New York. Objective Familiarize, or refamiliarize, oneself with the use of balances, mechanical pipettes, and volumetric glassware, and assess accuracy and precision of data generated. Principle of Method Proper use of equipment and glassware in analytical tests helps ensure more accurate and precise results. Supplies Equipment Notes 1 Beaker, 100 ml 1 Beaker, 20 or 30 ml 1 Beaker, 250 ml Buret, 25 or 50 ml Erlenmeyer flask, 500 ml Funnel, approximately 2 cm diameter (to fill buret) Mechanical pipettor, 1000 ml, with plastic tips Plastic gloves Ring stand and clamps (to hold buret) Rubber bulb or pipette pull-up Standard weight, 50 or 100 g Thermometer, to read near room temperature Volumetric flask, 100 ml 2 Volumetric pipettes, one each of 1 and 10 ml Analytical balance Top loading balance Before or during the laboratory exercise, the instructor is encouraged to discuss the following: (1) Difference between dispensing from a volumetric pipette and a graduated pipette, (2) difference between markings on a 10-ml versus a 25- or 50-ml buret. PROCEDURES (Record data in tables that follow.) 1. Obtain ~400 ml deionized distilled (dd) H 2 O in a 500-ml Erlenmeyer flask for use during this laboratory session. Check the temperature of the water with a thermometer. 2. Analytical balance and volumetric pipettes. (a) Tare a 100-ml beaker, deliver 10 ml of water from a volumetric pipette into the beaker, and record the weight. Repeat this procedure of taring the beaker, adding 10 ml, and recording the weight, to get six determinations on the same pipette. (Note that the total volume will be 60 ml.) (It is not necessary to empty the beaker after each pipetting.) (b) Repeat the procedure as outlined in Step 2a but use a 20- or 30-ml beaker and a 1.0-ml volumetric pipette. Do six determinations. 3. Analytical balance and buret. (a) Repeat the procedure as outlined in Step 2a, but use a 100-ml beaker, a 50-ml (or 25-ml) buret filled with water, and dispense 10 ml of water (i.e., tare a 100 ml beaker, deliver 10 ml of water from the buret into the beaker, and record the weight). (Handle the beaker wearing gloves, to keep oils from your hands off the beaker.) Repeat this procedure of taring the beaker, adding 10 ml, and recording the weight, to get six determinations on the buret. (Note that the total volume will be 60 ml.) (It is not necessary to empty the beaker after each addition.) (b) Repeat the procedure as outlined in Step 3a but use a 20- or 30-ml beaker and a 1.0-ml volume from the buret. Do six determinations. 4. Analytical balance and mechanical pipette. Repeat the procedure as outlined in Step 2a but use a 20- or 30-ml beaker and a 1.0-ml mechanical pipette (i.e., tare a 20- or 30-ml beaker, deliver 1 ml of water from a mechanical pipettor into the beaker, and record the weight). Repeat this procedure of taring the beaker, adding 1 ml, and recording the weight to get six determinations on the same pipettor. (Note that the total volume will be 6 ml.) (It is not necessary to empty the beaker after each pipetting.) 5. Total content (TC) versus total delivery (TD). Tare a 100-ml volumetric flask on a top loading balance. Fill the flask to the mark with water. Weigh the water in the flask. Now tare a 250-ml beaker and pour the water from the volumetric flask into the beaker. Weigh the water delivered from the volumetric flask. 6. Readability versus accuracy. Zero a top loading balance and weigh a 100-g (or 50-g) standard weight. Record the observed weight. Use gloves or finger cots as you handle the standard weight to keep oils from your hands off the weight. Repeat with the same standard weight on at least two other top loading balances, recording the observed weight and the type and model (e.g., Mettler, Sartorius) of balance used.

Chapter 2 Assessment of Accuracy and Precision 13 DATA AND CALCULATIONS Calculate the exact volume delivered in Parts 2 5, using each weight measurement and the known density of water (see Table 2-1). Using volume data, calculate the following indicators of accuracy and precision: mean, standard deviation, coefficient of variation, percent relative error, 95% confidence interval. Use your first three measurements for n = 3 values requested, and all six measurements for n = 6 values. 2-1 table Temperature ( C) Viscosity and Density of Water at Various Temperatures Density (g/ml) Viscosity (cps) Temperature ( C) Density (g/ml) Viscosity (cps) 20 0.99823 1.002 24 0.99733 0.9111 21 0.99802 0.9779 25 0.99707 0.8904 22 0.99780 0.9548 26 0.99681 0.8705 23 0.99757 0.9325 27 0.99654 0.8513 Data for Parts 2, 3, and 4: Rep Volumetric pipette Buret Mechanical pipettor 1 ml 10 ml 1 ml 10 ml 1 ml Wt. Vol. Wt. Vol. Wt. Vol. Wt. Vol. Wt. Vol. 1 2 3 4 5 6 n = 3 Mean S CV %E rel CI 95% n = 6 Mean S CV %E rel CI 95% Part 5 data: Water in flask= Water in beaker= Wt. Vol. Part 6 data: Balance 1 2 3 QUESTIONS 1. Theoretically, how are standard deviation, coefficient of variation, mean, percent relative error, and 95% confidence interval affected by: (1) more replicates, and (2) a larger size of the measurement? Was this evident in looking at the actual results obtained using the volumetric pipettes and the buret, with n = 3 versus n = 6, and with 1 ml versus 10 ml? (see table below) Standard deviation Coefficient of variation Mean Percent relative error 95% Confidence interval More replicates Type/Model of balance Theoretical Larger measurement Actual, with results obtained More replicates Wt. of standard weight Larger measurement 2. Why are percent relative error and coefficient of variation used to compare the accuracy and precision, respectively, of the volumes from pipetting/dispensing 1 and 10 ml with the volumetric pipettes and buret in Parts 2 and 3, rather than simply the mean and standard deviation, respectively? 3. Compare and discuss the accuracy and the precision of the volumes from the 1 ml pipetted/dispensed using a volumetric pipette, buret, and mechanical pipettor (Parts 2, 3, and 4). Are these results consistent with what would be expected? 4. If accuracy and/or precision using the mechanical pipettor are less than should be expected, what could you do to improve its accuracy and precision? 5. In a titration experiment using a buret, would you expect to use much less than a 10-ml volume in each titration? Would you expect your accuracy and precision to be better using a 10-ml buret or a 50-ml buret? Why?

14 Chapter 2 Assessment of Accuracy and Precision 6. How do your results from Part #5 of this lab differentiate to contain from to deliver? Is a volumetric flask to contain or to deliver? Which is a volumetric pipette? 7. From your results from Part #6 of this lab, would you now assume that since a balance reads to 0.01 g, it is accurate to 0.01 g? 8. What sources of error (human and instrumental) were evident or possible in Parts #2 4, and how could these be reduced or eliminated? Explain. 9. You are considering adopting a new analytical method in your lab to measure the moisture content of cereal products. How would you determine the precision of the new method and compare it to the old method? How would you determine (or estimate) the accuracy of the new method? Acknowledgment This laboratory was developed with inputs from Dr Charles E. Carpenter, Department of Nutrition and Food Sciences, Utah State University, Logan, UT. Resource Materials Nielsen SS (2010) Introduction to food analysis, Ch. 1. In: Nielsen SS (ed) Food analysis, 4th edn. Springer, New York Smith JS (2010) Evaluation of analytical data, Ch. 4. In: Nielsen SS (ed) Food Analysis, 4th edn. Springer, New York

Chapter 2 Assessment of Accuracy and Precision 15 Notes

http://www.springer.com/978-1-4419-1462-0