Performance evaluation of MEMS accelerometers

Similar documents
The accelerometer designed and realized so far is intended for an. aerospace application. Detailed testing and analysis needs to be

CHAPTER 3 MODAL ANALYSIS OF A PRINTED CIRCUIT BOARD

OPEN LOOP CONTROL OF FLEXIBLE BEAM PERIODIC MOTION VIA FREQUENCY RESPONSE ANALYSIS

Vibration Measurement of Wireless Sensor Nodes for Structural Health Monitoring

Transducer Mounting and Test Setup Configurations. Rick Bono The Modal Shop

DAMPING BEHAVIOUR OF CAST AND SINTERED ALUMINIUM

Comparison of the Response of a Simple Structure to Single Axis and Multiple Axis Random Vibration Inputs

The Calculation of G rms

Sensor Performance Metrics

Herschel PACS Test Procedure STM PACS-KT-PR-011 Issue: 1 Revision: -

Fiber Optic High Density ACC Sensor System Faser Optisches Beschleunigungs-Messsystem

Experiment #11: LRC Circuit (Power Amplifier, Voltage Sensor)

Time Domain and Frequency Domain Techniques For Multi Shaker Time Waveform Replication

4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is:

RLC Series Resonance

SEISMIC MONITORING & PROTECTION SYSTEMS

Similar benefits are also derived through modal testing of other space structures.

Lecture 1-6: Noise and Filters

Nano Meter Stepping Drive of Surface Acoustic Wave Motor

MICROPHONE SPECIFICATIONS EXPLAINED

Experimental Modal Analysis

RANDOM VIBRATION AN OVERVIEW by Barry Controls, Hopkinton, MA

An Electromagnetic Micro Power Generator Based on Mechanical Frequency Up-Conversion

Laboratory 4: Feedback and Compensation

Non-Contact Vibration Measurement of Micro-Structures

SOFTWARE FOR GENERATION OF SPECTRUM COMPATIBLE TIME HISTORY

Department of Aerospace Engineering Indian Institute of Science Bangalore

Understanding Dynamic Range in Acceleration Measurement Systems. February 2013 By: Bruce Lent

MEMS mirror for low cost laser scanners. Ulrich Hofmann

Frequency Response of Filters

INTER-NOISE AUGUST 2007 ISTANBUL, TURKEY

Decoding an Accelerometer Specification. What Sensor Manufacturer s Don t Tell You! David Lally VP Engineering PCB Piezotronics, Inc.

ENS 07 Paris, France, 3-4 December 2007

The Fundamentals of Signal Analysis. Application Note 243

The Sonometer The Resonant String and Timbre Change after plucking

Cell Phone Vibration Experiment

VCO Phase noise. Characterizing Phase Noise

Onboard electronics of UAVs

State Newton's second law of motion for a particle, defining carefully each term used.

Safakcan Tuncdemir 1, William M. Bradley *2. 1. Introduction

Overview of Energy Harvesting Systems (for low-power electronics)

III. MEMS Projection Helvetica 20 Displays

Micro Power Generators. Sung Park Kelvin Yuk ECS 203

Simulation and Design of Printed Circuit Boards Utilizing Novel Embedded Capacitance Material

Detecting & Locating Leaks in Water Distribution Polyethylene Pipes

Fermi National Accelerator Laboratory. The Measurements and Analysis of Electromagnetic Interference Arising from the Booster GMPS

Active Vibration Isolation of an Unbalanced Machine Spindle

Linear Parameter Measurement (LPM)

Design and Simulation of Soft Switched Converter Fed DC Servo Drive

The Design and Characteristic Study of a 3-dimensional Piezoelectric Nano-positioner

STUDY OF DAM-RESERVOIR DYNAMIC INTERACTION USING VIBRATION TESTS ON A PHYSICAL MODEL

Fabrication of Complex Circuit Using Electrochemical Micromachining on Printed Circuit Board (PCB)

Magnetic Field Modeling of Halbach Permanent Magnet Array

Mitigating Power Bus Noise with Embedded Capacitance in PCB Designs

ε: Voltage output of Signal Generator (also called the Source voltage or Applied

Precision Diode Rectifiers

Jitter Transfer Functions in Minutes

DEVELOPMENT OF A VIBRATION POWERED MICRO GENERATOR AND ITS APPLICATION TO HARVEST THE VIBRATION ENERGY OF THE KRI KKP- 811 S ENGINE

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

A wave lab inside a coaxial cable

AN-007 APPLICATION NOTE MEASURING MAXIMUM SUBWOOFER OUTPUT ACCORDING ANSI/CEA-2010 STANDARD INTRODUCTION CEA-2010 (ANSI) TEST PROCEDURE

Voltage. Oscillator. Voltage. Oscillator

Methods to predict fatigue in CubeSat structures and mechanisms

The use of Operating Deflection Shapes (ODS) to model the vibration of sanders and polishers HSL/2006/104. Project Leader: Author(s): Science Group:

STRUCTURAL TESTING. Part I: Mechanical Mobility Measurements. By Ole Døssing, Brüel & Kjæ

Self-Mixing Laser Diode Vibrometer with Wide Dynamic Range

Micro-Power Generation

INTERFERENCE OF SOUND WAVES

Construction and experiment on micro-gyroscope detection balance loop

Troubleshooting accelerometer installations

A NEW SENSOR FOR STATIC AND DYNAMIC FORCE MEASUREMENT

Lab #9: AC Steady State Analysis

SHOCK AND VIBRATION RESPONSE SPECTRA COURSE Unit 3. Sine Sweep Frequency and Octave Calculations

Making Accurate Voltage Noise and Current Noise Measurements on Operational Amplifiers Down to 0.1Hz

Output of an Ultrasonic Wave-Driven Nanogenerator in a Confined Tube

Development of New Inkjet Head Applying MEMS Technology and Thin Film Actuator

Automotive. Aerospace. bout Us. Defense. Energy. Maritime. Education. Electronics. and more

AIR RESONANCE IN A PLASTIC BOTTLE Darrell Megli, Emeritus Professor of Physics, University of Evansville, Evansville, IN dm37@evansville.

Vibration Monitoring: Envelope Signal Processing

Time Series Analysis: Introduction to Signal Processing Concepts. Liam Kilmartin Discipline of Electrical & Electronic Engineering, NUI, Galway

Dynamic Process Modeling. Process Dynamics and Control

Small, Low Power, 3-Axis ±3 g Accelerometer ADXL335

PeakVue Analysis for Antifriction Bearing Fault Detection

Experiment 3: Double Sideband Modulation (DSB)

ENGINEERING EXPERIMENT STATION COLLEGE OF ENGINEERING THE UNIVERSITY OF ARIZONA TUCSON, ARIZONA USE OF A THREE-LAYER DISTRIBUTED RC NETWORK

TESTS OF 1 MHZ SIGNAL SOURCE FOR SPECTRUM ANALYZER CALIBRATION 7/8/08 Sam Wetterlin

FREQUENCY RESPONSE ANALYZERS

MXD7202G/H/M/N. Low Cost, Low Noise ±2 g Dual Axis Accelerometer with Digital Outputs

Development of MEMS micromirrors for intracavity laser control

Constructing a precision SWR meter and antenna analyzer. Mike Brink HNF, Design Technologist.

APPLICATION NOTE ULTRASONIC CERAMIC TRANSDUCERS

Piezoelectric Driven Non-toxic Injector for Automated Cell Manipulation

Probability and Random Variables. Generation of random variables (r.v.)

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Product Overview 9100D

Bass Guitar Investigation. Physics 498, Physics of Music Sean G. Ely Randall Fassbinder

State Newton's second law of motion for a particle, defining carefully each term used.

Silicon-On-Glass MEMS. Design. Handbook

Undergraduate Research Projects for Engineering Technology Students

VIBRATION CONTROL APPLIED TO AN ELECTRODYNAMIC EXCITER TO IMPROVE ACCELEROMETER CALIBRATIONS

Transcription:

Performance evaluation of MEMS accelerometers A. Albarbar¹ ' *, A. Badri¹, Jyoti K. Sinha¹, A. Starr² ¹School of Mechanical, Aerospace and Civil Engineering, University of Manchester, P.O. Box 88, Manchester, M6 QD ²School of Automotive, Aerospace and Design Engineering, University of Hertfordshire, Hatfield, Herts AL 9AB Abstract Researchers have been looking for alternatives of expensive conventional accelerometers in vibration measurements. Micro-ElectroMechanical Systems (MEMS) accelerometer is one of the available options. Here the performance of one of these MEMS accelerometers compared with a well known commercial accelerometer. Key Words Condition Monitoring, Micro-elecromechanical System (MEMS) Accelerometer, Vibration Measurements, Frequency Response Function. *Corresponding Author a.albarbar@mmu.ac.uk Office no. +44()62476297

.. Introduction Condition based monitoring is now accepted practice for critical machines and structures for Industries to enhance availability, low maintenance costs and plant safety. Often, the decisions regarding the repair or replacement of a machine part, overhauls, and standard maintenance are made on the basis of the measured condition of the machine. One such monitoring technique is vibration based condition monitoring. Measuring vibration is very essential in detecting and diagnosing any deviation from normal conditions. The use of conventional piezoelectric accelerometers in vibration measurements is well known and accepted, but at high cost especially if simultaneous multiple data collection points are required; this is mainly because of their cost and the price of the associated electronic signal conditioning circuits. The recent advances in embedded system technologies such as micro-electrical mechanical systems (MEMS) sensors hold a great promise for the future of vibration measurement based condition monitoring which is a much cheaper alternative. It has built-in signal conditioning unit as well. The cost of MEMS accelerometer may be just % or less compared to the commercially available cheapest conventional accelerometer together with the signal condition unit. There are number of research studies in the literature [-8] about the MEMS accelerometers construction and the measurement principle. The use of the MEMS accelerometers is still limited to testing stage in the laboratory experiments. Thanagasundram and Schlindwein [9] have used the MEMS accelerometer together with a conventional accelerometer for measuring the vibration of a pump during its normal operation. They [9] found the frequency content from both sensors were in agreement. However no rigorous investigation has been done to compare the performance of this MEMS accelerometer which is required to measure the different kinds of signals sinusoidal, random, and impulsive signals []. Hence the performance of one of these 2

MEMS accelerometers compared with a well known commercial accelerometer used for years together which are discussed here through a simple test facility. 2.. MEMS Accelerometer MEMS accelerometers are divided into two main types: peizoresistive and capacitive based accelerometers [8]. The conventional piezoelectric accelerometers generally consist of a single-degree of freedom system of a mass suspended by a spring. Here in piezoresistive MEMS Accelerometer also, it has a cantilever beam having a proof mass at the beam tip and a peizoresistive patch on the beam web. The schematic of a peizoresistive MEMS accelerometer is shown in Figure (a). The movement of the proof mass when subjected to vibration changes the resistance of the embedded piezoresistor. The electric signal generated from the piezoresistive patch due to change in resistance is proportional to the acceleration of the vibrating object. The capacitive based MEMS accelerometers measure changes of the capacitance between a proof mass and a fixed conductive electrode separated by a narrow gap [8]. The schematic of a capacitive MEMS accelerometer is shown in Figure (b). The papers [-8] gave the details of the working principle and so not discussed here. 3.. Test Setup A schematic of the Test setup is shown in Figure 2. The setup consists of a small shaker (M/s GW make) together with a shaker power amplifier, signal generator and a PC based data acquisition for data collection and storage for further signal processing in MatLab. Two accelerometers (one PCB accelerometer and other capacitive type MEMS accelerometer) were attached back to back on the armature attached to the shaker as shown in Figure 2. The PCB accelerometer used for this experiment is an ICP (Integrated Circuit Piezoelectric) type with the technical specifications mv/g, Linear Frequency range upto 2 khz, 5 g level. This type of Accelerometers has been calibrated as per the ISO/IEC 725 standard and well accepted in practice because of their performance. A typical MEMS accelerometer of technical specifications 25mV/g, Frequency range khz, 5 g level is used for comparison [] which is relatively new technology for the accelerometer. 3

4.. Testing and Results As it is well known that the accelerometers are used for measuring the periodic (sinusoidal, step-sine, multi-sine, etc.), random and impulsive signals [], hence these tests were carried out on the Test setup and results were compared. 4.. Periodic Excitation Sinusoidal signals were given to the shaker at two frequencies -66Hz and 57Hz deliberately away from the line frequency of 5Hz and its harmonics. Number of experiments was performed at these two frequencies with different amplitude levels of shaker excitation and simultaneously responses were measured from both accelerometers. Few typical measured responses both in time and frequency domain is shown Figures 3 to 5. No distortion is seen in the measured responses by the MEMS accelerometer as well. However there is significant shift in phase and the sensitivity compared to the reference accelerometer. In fact the estimated sensitivity based on reference accelerometer seems to be varying from 38mV/g to 69mV/g and phase shift is also not constant with respect to the reference accelerometer responses which are clearing seen in the time response plots in Figures 3, 4 and 5. 4.2. Random Excitation Similar to the sinusoidal tests; the shaker was excited with random excitation in a frequency band from Hz to.5 khz with different amplitudes. Typical responses of both accelerometers in time and frequency domains are shown in Figure 6. Both accelerometers responses look to be identical in time and frequency domains, but here again the estimated sensitivity found to be 225mV/g though it is close to the design value of the sensitivity for this MEMS accelerometer but much different than the estimated sensitivity during the sinusoidal tests. 4

To determine the linearity in the measurement over the frequency band of excitation and phase shift, the frequency response function (FRF- the transfer function in frequency domain) has also been calculated assuming the responses of the MEMS accelerometer as the output and the reference accelerometer responses as the input. Both the amplitude and phase FRF plots are shown in Figure 7. Although the response spectra shown in Figure looks to be identical but the amplitude deviation between two accelerometers is found to be approximately upto -2dB at some frequencies and the phase shift of 8 degree upto around Hz and then the shift is approximately linear from 8 degree at Hz to zero degree at.5khz. 4.3. Impulsive Excitation In the same experimental setup, the impact excitation was given at the centre of the armature using a soft tip hammer within the frequency band of excitation up to 4-5Hz. Typical time domain responses of both accelerometers are shown in Figure 8. The measured responses are typically decay type responses as expected for the impact excitation by both accelerometers with maximum amplitude level of.6g. However the estimated sensitivity once again found to be 55.9mV/g which is different than earlier estimated values and the fast decay in the response seen in the MEMS accelerometer compared to the reference accelerometer. To understand this typical behaviour of the MEMS accelerometer, the averaged spectra of the 3 decay responses were computed for both accelerometers and compared which is shown in Figure 8. The presence of the frequency peaks is consistent in both responses, however the peaks amplitudes are much different. Since the MEMS accelerometer introduces the phase shift known from previous tests, so these phase shift at different frequencies might be resulted into the fast decay in the measured responses compared to the reference accelerometer. 4.4. Further Analysis In vibration analysis, the ordinary coherence between two vibration signals is defined as [2]: 2 S xy S, 2 Coh () S yy xx 5

where S xx (ω) and S yy (ω) are the power spectral densities of two signals, x(t) and y(t), and S xy (ω) is their cross-power spectrum at an angular frequency (ω). The coherence between two signals indicates the degree to which two signals are linearly correlated at a given frequency. The Coherence (Coh) is close to unity means the signal x(t) is linearly correlated to the signal y(t). Reduction in the coherence from indicates that the two signals are either noisy or having nonlinear relation. Hence the coherence was computed between two responses measured by the MEMS and the reference Accelerometers. Figure 9 shows the coherence plots for the random and impact tests. Generally coherences are above.8 at many frequencies indicating good relation between two signals, but also low at several other frequencies. Hence this indicates the measurements by the MEMS accelerometer used in the present study deviate compared to the reference accelerometer. 5. Comments The performance tests of a typical capacitive type MEMS accelerometer are carried out for different excitations sinusoidal, random and impulse. The measured responses of the MEMS accelerometer were compared with a well accepted ICP type accelerometer. All tests were conducted well within the technical specifications of both accelerometers. The MEMS accelerometer is seems to be performing well for the sinusoidal and random measurements though shift in phase is observed, and the frequency peaks content is also found to be same in comparison with the conventional accelerometer for the impact excitation. However the tests performed here clearly show lots of improvement needed before its use in practice. It is being planed to carry out more investigation with several numbers of the MEMS accelerometers to understand the future direction for improvements. References. Plaza J., Collado A., Cabruja E., Esteve J., Piezoresistive accelerometers for MCM package, Journal of Microelectromech. Systems, vol., no. 6, pp. 794 8, Dec. 22. 6

2. Xie H., Fedder G., CMOS z-axis capacitive accelerometer with comb-finger sensing, Proc. IEEE Micro Electro Mechanical Systems (MEMS), 2, pp. 496 5. 3. Biefeld V., A. Buhrdorf, and J. Binder, Laterally driven accelerometer fabricated in single crystalline silicon, Sensors & Actuators A: Phys., vol. 82, no., pp. 49 54, May 2. 4. Yazdi N., F. Ayazi, and K. Najafi, Micromachined inertial sensors, Proc. IEEE, vol. 86, no. 8, pp. 64 659, August 998. 5. Liu C., and T.W. Kenny, A high-precision, wide-bandwidth micromachined tunneling accelerometer, Journal of Microelectromech. Systems, vol., no. 3, pp. 425 433, 2. 6. Li L., Y. Xu, Y. Zhao, C. Liang, T. Wei, and Y. Yang, Micromachined accelerometer based on electron tunneling, Proc. SPI-International. Society Optical Engineering., vol. 389, pp. 2 25, 999. 7. Seshia A., Palaniapan M., Roessig T, Howe R., Gooch R., Schimert T., Montague S., A vacuum packaged surface micromachined resonant accelerometer, Journal of Microelectromech. Systems, vol., no. 6, pp. 784 793, 22. 8. Gao R., Zhang L., Micromachined microsensors for manufacturing, IEEE Instrumentation & Measurement Magazine, 24, 94-6969. 9. Thanagasundram S., Schlindwein F., Comparison of integrated micro-electricalmechanical system and piezoelectric accelerometers for machine condition monitoring, IMechE Journal of Mechanical Engineering Science Part C, 22 35-46, 26.. Sinha, Jyoti K., On Standardisation of calibration procedure for accelerometer. Journal of Sound and Vibration, 25, 286(25)47-427.. Albarbar A. Starr A., Pietruszkiewicz R., To Wards the implementation of integrated multimeasurand wireless monitoring system. Proc. Second world congress on Engineering and Asset Management, pp. 96 5, June 27. 2. Suryam B.C.B.N, Meher K.K., Sinha J. K., Rao A., Coherence measurement for early contact detection between two components, Journal of Sound and Vibration, 29(26)59-523. 7

Piezoresistors Substrate Vibration Cantilever Substrate Sensing Capacitors Vibration Seismic Mass Base Proof mass (a) (b) Figure A typical MEMS accelerometer construction; (a) peizoresistive using cantilever design, (b) capacitive based on membrane design [8] MEMS back to back with Conventional Accelerometer Signal Conditioning Signal Processing and Data Display S.C. Shaker NI DAQ Card Power Amplifier Signal Generator Figure 2 Test setup 8

.4.2 -.2 MEMS, Sensitivity 46.mV/g -.4..2.3.4.5.6.4.2 -.2 PCB Accelerometer -.4..2.3.4.5.6 (a) Time domain signals.4.3 MEMS.2. 5 5 2 25 3.4.3 Accelerometer.2. 5 5 2 25 3 (b) Spectra Figure 3 Measured acceleration responses by the MEMS accelerometer and the reference (PCB) accelerometer at 66Hz for the excitation level.3g 9

.5 -.5 MEMS, Sensitivity 68.9mV/g -..2.3.4.5.6.5 -.5 PCB Accelerometer -..2.3.4.5.6 (a) Time domain signals.8.6 MEMS.4.2 5 5 2 25 3.8.6 Accelerometer.4.2 5 5 2 25 3 (b) Spectra Figure 4 Measured acceleration responses by the MEMS accelerometer and the reference (PCB) accelerometer at 66Hz for the excitation level.75g

.5 -.5 MEMS, Sensitivity 38.3mV/g -..2.3.4.5.6.5 -.5 PCB Accelerometer -..2.3.4.5.6 (a) Time domain signals.8.6 MEMS.4.2 2 3 4 5.8.6 Accelerometer.4.2 2 3 4 5 (b) Spectra Figure 5 Measured acceleration responses by the MEMS accelerometer and the reference (PCB) accelerometer at 57Hz for the excitation level.65g

MEMS, Sensitivity 225.3mV/g.5 -.5 -.5..5.2.25.3.35.4 PCB Accelerometer.5 -.5 -.5..5.2.25.3.35.4 (a) Time domain signals. MEMS.5 2 4 6 8 2 4 6. Accelerometer.5 2 4 6 8 2 4 6 (b) Spectra Figure 6 Measured acceleration responses by the MEMS accelerometer and the reference (PCB) accelerometer for the random excitation 2

FRF Phase, deg. FRF Amplitude 5 MEMS/PCB Accelerometer -5-2 4 6 8 2 4 6 2 - MEMS/PCB Accelerometer -2 2 4 6 8 2 4 6 Figure 7 A typical measured FRF for the random excitation 3

.5 -.5 MEMS, Sensitivity 55.9mV/g - 2 3 4 5.5 -.5 PCB Accelerometer - 2 3 4 5 (a) Time domain signals -2 MEMS -4-2 5 5 2 25 3 Accelerometer -4 5 5 2 25 3 (b) Spectra Figure 8 A comparison of measured responses by MEMS accelerometer and the PCB accelerometer when the shaker armature excited by impacts from a hammer 4

Coherence Coherence.9 MEMS/PCB Accelerometer.8.7.6.5.4.3.2 (a). 2 4 6 8 2 4 6.9.8.7.6.5.4.3.2 (b). MEMS/PCB Accelerometer 5 5 2 25 3 Figure 9 Coherence plots between the measured responses by the MEMS and the reference Accelerometers (a) Random Test, (b) Impact Test 5