VWR ph & REDOX ELECTRODES

Similar documents
ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

Laboratory Electrochemistry Products. ph Conductivity Dissolved Oxygen

Compact ph Measuring Instruments

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

JUMO tecline HD ph and JUMO tecline HD Rd

USEPA Electrode Method Method 8156

SenTix 950 SenTix 980

ph Measurements of Common Substances

ph Measurement and Control

Ion Selective Electrodes

Household Acids and Bases

Handbook. Thermo Scientific. ph Electrode Selection Handbook

REDOX AND REFERENCE ELECTRODE USER MANUAL

Conductivity and TDS Meters

ELECTROCHEMISTRY. Theory and Practice

HND-R. Hand-held ph, Redox and Temperature Measuring Units

Compact Water Quality Meter B-700 series

Lesson Plan: How Do We Know What is Healthy Water?

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

Eutech 2700 Series. Bench Meters. ph ORP ION Conductivity TDS Salinity Resistivity Dissolved Oxygen Temperature

Measurement by Ion Selective Electrodes

Ion-selective Measurements

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

Acids, Bases, and ph

ph, redox and I.S.E. electrodes

WORKSHEET: ph and Water 23 Lab Instructor: Lab Day & Time: Student name(s): drain cleaner flat soda pop window cleaner ammonia.

Chapter 6. Solution, Acids and Bases

A Useful Tool for the Determination of Consistency in Semi-Solid Substances

Total Dissolved Solids:

STOCKMEIER water chemicals Strong bonds for clear water

Chem 100 Lab Experiment #9 - ACID/BASE INDICATORS

EXPERIMENT 20: Determination of ph of Common Substances

ORGANIC SAMPLE PREPARATION

RBS detergents for laboratories

Teacher Demo: Turning Water into Wine into Milk into Beer

CLEANING WATER. Student Section

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

Conductivity Theory and Practice

The Effects of Temperature on ph Measurement

CHM 130LL: ph, Buffers, and Indicators

OT 40L / 90L. Laboratory Steam Sterilizers

Care, Maintenance, and Storage of YSI 6-Series Probes and Sondes

Wherever chemical solutions are involved, ph matters. Some

Conductivity measurements are used for applications such as in the production of ultrapure water or determining the salinity of sea water.

Your 2015 / 2016 Recycling Guide. We re recycling are yo? wasteteam@chiltern.gov.uk wasteteam@wycombe.gov.uk

How to Use Water Safely in Your Food Establishment During a Boil Water Advisory

Kemet DIAMOND PRODUCTS

Care. Drinks. Tissues collection. Sun protection, lips, Fair Trade, condoms, nails, first aid, dental, cosmetic bags

How To Understand The Cottage Foods Act

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

AIRMoN, ph and Conductivity Field Measurement

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

Care and use guide. Contents. a handy solution made easy. page

Donau Kanol GmbH & Co KG Organization. Jänner Donau Chemie Gruppe

National Food Safety Standard Food microbiological examination: Aerobic plate count

Lab Exercise 3: Media, incubation, and aseptic technique

Chapter 3: Separating Mixtures (pg )

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges

World Class Equipment worldwide Edition J

A Potentiometric Analysis of Fluoride Ion in Toothpaste

Stainless Steel Dissolved Oxygen Electrodes

Blood Collection and Processing SOP

Milwaukee USER MANUAL

Conductivity measurement on pure water according to the recommendations of the USP Pharmacopoeia USP24-NF19

WASTEWATER TREATMENT OBJECTIVES

for Dundee Your NEW recycling service What s new What you should recycle Your containers Find out more inside

CONDUCTIVITY SENSOR. Description D0382. Figure 1. The Conductivity Sensor

Acids and Bases. AND a widemouth container of the following solids:

Chapter 6: Mixtures. Overall Objectives Introduction 46. Time Required: 6.2 Types of mixtures 46

Microbiological Testing of the Sawyer Mini Filter. 16 December Summary

Fluoride Strengthens Teeth

Depletion Respiration

Nutrition and Chronic Kidney Disease

Prevent & Save. Best Practice Guidelines in Waste Management. Waste Management for the Hospitality Industry

DNA SPOOLING 1 ISOLATION OF DNA FROM ONION

Phosphorus, Reactive (Orthophosphate)

Standard buffer solutions for ph-meter calibration. Reliable Traceable to NIST Tested according to DIN and DIN Supplied with certificate

DATA CAPTURE. Helpline: , , , ,

Chemists use the ph value to measure how acidic or basic a solution is. The ph scale runs from 0 to 14:

ph and Acidity in Wine and Fruit Juice

Appendix C. Vernier Tutorial

TurbiDirect TurbiCheck TurbiCheck WL

SINGLE RANGE DS METERS Operation Instructions

LABOKLAV. Autoclaves Made in Germany.

Ch. 57 MILK AND DAIRY PRODUCTS 7 CHAPTER 57. MILK AND DAIRY PRODUCTS GENERAL PROVISIONS

Syllabus OC18 Use litmus or a universal indicator to test a variety of solutions, and classify these as acidic, basic or neutral

Introduction. ph = log [H + ]

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Syllabus M.Tech. Food Technology DSC- FT- 1 A: FUNDAMENTALS OF FOOD SCIENCE AND TECHNOLOGY PART I

City of Cardiff Council Commercial Waste Service

Determination of raw milk quality

Farmer s Markets. Regulatory Considerations for Tennessee Food Manufacturers. Mike Brown Outreach Coordinator Tennessee Department of Agriculture

Expertise in liquid analysis From sensors to complete turnkey solutions

Your NEW. recycling service. household waste. and. Your new recycling guide What to recycle How to recycle Find out more inside

Acid 7 Base. 1. Describe two things hydrochloric acid does in your body system. 2. What does sodium hydrogencarbonate do in your body system?

Experiment 9: Acids and Bases Adapted from: Chemistry, Experimental Foundations, 4th Ed. Laboratory Manual, by Merrill, Parry & Bassow.

ROTARY PISTON PUMPS THE FEED PUMP TYPE SKK. The variants of the feed pump SKK. Range of pumping liquids (extr.) Reference technical data.

5.0 EXPERIMENT ON DETERMINATION OF TOTAL HARDNESS

Properties of Acids and Bases

Transcription:

VWR ph & REDOX ELECTRODES For every application For any ph meter Reliable performance

VWR ph & REDOX ELECTRODES LABORATORY AND FIELD ELECTRODES FOR EVERY APPLICATION AND ph METER Compact electrodes for general use, small samples, surface measurements and semi-solid samples Comfortable handling and reliable functionality Quality assured All VWR electrodes are checked, at 2 points (Universal electrodes) and 5 points (phenomenal ), during the manufacturing process and then lot stamped to ensure quality Every electrode is supplied with a soaker storage cap to ensure the ph sensitive glass and reference junction is in top condition and instantly ready for use phenomenal models come with a quality certificate and serial number making documentation and traceability easier Technical specifications Parameter Specification Universal phenomenal ph range 0-14 ph Temperature range ( C) 0-80 for epoxy body Diaphragm Electrolyte Single or double 0-100 for glass body 80 for epoxy body Single junction or platinum Gel or liquid Redox Redox range ±2000 mv Temperature range ( C) 0-80 for epoxy body 0-80 glass body 0-100 for glass body - Type Model DxH (mm) Connection SJ113 12x120 BNC 662-1382 Single junction SJ114 12x120 DIN 662-1383 SJ 115 12x120 S7 662-1384 DJ 113 12x120 BNC 662-1385 Double junction DJ114 12x120 DIN 662-1386 DJ115 12x120 S7 662-1387 SF113 12x120 BNC 662-1388 Surface SF114 12x120 DIN 662-1389 SF115 12x120 S7 662-1390 EPOXY SHAFT AND GEL ELECTROLYTE Type Model DxH (mm) Connection Single junction Surface Semi-micro Spear electrode SJ223 12x120 BNC 662-1395 SJ224 12x120 DIN 662-1396 SJ225 12x120 S7 662-1397 SF223 12x120 BNC 662-1398 SF224 12x120 DIN 662-1399 SF225 12x120 S7 662-1401 SM223 6x120 BNC 662-1402 SM224 6x120 DIN 662-1403 SM225 6x120 S7 662-1404 SP223 12/6x120 BNC 662-1405 SP224 12/6x120 DIN 662-1406 SP225 12/6x120 S7 662-1407 GLASS SHAFT AND LIQUID ELECTROLYTE Ag/AgCl - 3 MOL/l KCl 2 VWR INTERNATIONAL VWR COLLECTION PRODUCTS: DELIVERING HIGH QUALITY & SUPERIOR PERFORMANCE

UNIVERSAL CABLES FOR ph ELECTRODES - 1 m Cable with BNC connector Coax 53 662-1410 Cable with DIN connector Coax 54 662-1411 Cable with EE connector (Radiometer) Coax 56 662-1412 Cable with R connector (Metrohm) Coax 57 662-1413 PHENOMENAL PH ELECTRODES WITH BNC CONNECTOR Model Type Built-in temperature sensor *3 m cable Electrodes with epoxy shaft and gel electrolyte with 1 m cable. DxH 12x120 mm phenomenal 110 phenomenal 111 phenomenal 111-3* No 662-1156 Yes 662-1157 Yes 662-1158 Electrodes with glass shaft and Ag/AgCl - 3 mol/l KCl liquid electrolyte with 1 m cable. DxH 12x120 mm phenomenal 211-3* phenomenal 220 phenomenal 221 phenomenal LS 221 platinum Yes 662-1162 No 662-1159 Yes 662-1161 Yes 662-1247 phenomenal MIC 220 Semi-micro No 662-1163 Glass electrode with gel fill, 1 m cable. DxH 12/6x120 mm phenomenal SPEAR 220 Spear electrode No 662-1164 REDOX ELECTRODES WITH 1 m CABLE AND BNC CONNECTOR DxH (mm) Model Type Body shaft Electrolyte 12x120 RD 113 Plastic redox electrode 12x120 RD 223 Glass redox electrode 12x120 phenomenal ORP 220 Glass redox electrode Epoxy Gel 662-1408 Glass 3,5 M KCl 662-1409 Glass 3,5 M KCl 662-1165 VWR COLLECTION PRODUCTS: DELIVERING HIGH QUALITY & SUPERIOR PERFORMANCE VWR INTERNATIONAL 3

VWR ph & REDOX ELECTRODES Application guide: Application area Sub segment Single junction SJ 113 / 114 / 115 phenomenal 110 / 111 Gl Agriculture Fertiliser solutions Beverage Chemistry Cosmetics Fruits Soil (eluate) Vegetables Beer Fruit juice Mineral water Spirits/wine Acids solutions Bleach and dying solutions Emulsions Electroplating bath and pickling Ink Oil/water emulsions Paint/varnish Viscose samples Semi-solid samples Creme Lotion Make-up Shampoos Shaving foam Soap Toothpaste Education Economic General purpose Research grade Field measurements Ground, lake and river Food Dairy Pharma/Biotech Surface Washing agents Rain water Seawater Bread Coffee Honey Jam Marmelade Mayonnaise Meat/fish Butter Cheese Cream Milk Yoghurt Agar-agar gel Bacteria culture Enzyme solutions Serum Small sample quantity Tris buffer Paper Skin Textile Detergents Dishwashing liquid Disinfectant Soap solution Water Aquarium Cooling water Drinking water Purity water Salt water Wastewater, general 4 VWR INTERNATIONAL VWR COLLECTION PRODUCTS: DELIVERING HIGH QUALITY & SUPERIOR PERFORMANCE

ass single junction SJ 223 / 224 / 225 Double junction DJ 113 / 114 / 115 phenomenal glass electrodes 211 / 220 / 221 phenomenal glass electrodes LS 221 Surface SF 113 / 114 / 115 Surface SF 223 / 224 / 225 Semi-micro SM 223 / 224 : 225 phenomenal semimicro MIC 220 Spear elecrode SPEAR 223 / 24 / 225 phenomanal spear elecrode SPEAR 220 VWR COLLECTION PRODUCTS: DELIVERING HIGH QUALITY & SUPERIOR PERFORMANCE VWR INTERNATIONAL 5

VWR ph & REDOX ELECTRODES Ready to use ph buffers: AVS TITRINORM Traceable to SRM (Standard Reference Materials) from NIST Batch number and packing date for traceability Certificate of analysis available on the web Supplied in 100 ml bottles AVS TITRINORM buffer solution ph 4 32095.184 ph 7 32096.187 ph 10 32040.185 Coloured buffer dosing bottles Packed in an innovative twin neck, 1 l bottle, the buffer stock is protected from contamination once the bottle is open, while the correct amount is dispensed into the calibration chamber for use. Better buffer stability when the bottle is opened Traceability to SRM from NIST Easy to carry, ideally suited for field work No additional containers needed Less waste Description ph 4,00 (red coloured) 32044.290 ph 7,00 (green coloured) 32045.290 ph 9,00 (blue coloured) 32046.290 Buffers secondary standards Solution standardised at 25 ºC Accurate to ±0,01 ph units (except ph>10 with 0,05 ph units) Traceable to NIST, DIN19266 and IUPAC ISO 17025 compliant Supplied with Certificate of Analysis T dependance data is printed on the labels as are batch number and expiry date Supplied in 500 ml plastic bottles Description ph 1,679 84580.260 ph 3,776 84581.260 ph 4,005 84582.260 ph 6,865 84583.260 ph 7,413 84584.260 ph 9,18 84584.260 ph 10,012 84585.260 ph 12,454 84587.260 Maintenance and cleaning solutions Description Pk (ml) 100 83605.180 BDH Prolabo KCl (3 mol/l) electrolytic solution 500 83605.260 BDH Prolabo cleaning solution 100 83603.180 6 VWR INTERNATIONAL VWR COLLECTION PRODUCTS: DELIVERING HIGH QUALITY & SUPERIOR PERFORMANCE

ACCESSORIES Articulated stand for 4 electrodes and temperature sensor 662-1169 Storage vessel for ph electrodes (12 mm diameter) with bayonet connector 662-1248 Electrode storage tube for transportation 662-1167 VWR FOR ALL YOUR ELECTROCHEMISTRY NEEDS CONDUCTIVITY DISSOLVED OXYGEN MULTI-PARAMETER METERS, ELECTRODES/SENSORS, BUFFERS, STANDARDS AND REFERENCE MATERIALS...AND MUCH MORE CHECK OUT VWR.COM OR CONTACT YOUR LOCAL VWR SALES OFFICE. VWR COLLECTION PRODUCTS: DELIVERING HIGH QUALITY & SUPERIOR PERFORMANCE VWR INTERNATIONAL 7