Fully-automated Hematology Analyzer MEK-9100K

Similar documents
BC Auto Hematology Analyzer

Pentra DX Nexus. Process efficiency in Hematology

XE-2100 Automated Hematology System. Fast, Accurate, Dependable

HumaCount System Line A Better Way to Connect. A Better Way to Work.

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

Symmetry in Diagnostics HPLC ANALYZER. Gold Standard Accuracy by Ion-Exchange HbA1c. TOSOH BIOSCIENCE

Collect and label sample according to standard protocols. Gently invert tube 8-10 times immediately after draw. DO NOT SHAKE. Do not centrifuge.

QUALITY CONTROL (QC) INFORMATION AND TROUBLESHOOTING GUIDE HEMATOLOGY

GC-xt. The most flexible GC /GC-MS liquid sample injector

endless One platform possibilities for DNA, RNA, protein and cell analysis Agilent 2100 Bioanalyzer Our measure is your success.

INNOVATION TO MEET YOUR NEEDS

OPSIS LiquidLINE KjelROC Distillation Unit

Department of Pathology and Laboratory Medicine Capital District Health Authority Nova Scotia

VICKERS HARDNESS TESTER. HBS HBW Kc

Expert workflow management cobas p 312 pre-analytical system The new dimension of laboratory automation

Welcome to the fully integrated autoimmune laboratory. Saves time by reducing hands-on functions NOVA Lite Barcoded IFA Slides

Reshaping compact automation. XN-Series Automated Hematology Systems

Discover Your Potential

LOAD & GO and make flow cytometry simplicity itself. the full spectrum of Flow Cytometry

Discover Your Potential

RDW-- Interpreting the Full Blood Count

Hematology Morphology Critique

haze-gard i The objective standard for a clear view Global communication Reliable and Precise

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

22 (21.5 viewable) Smart Display, Full HD, Rockchip Quad-Core, Optical touch, Android KitKat. VSD224

Operating Principle of the Sample Positioning Flaps

History of Innovation

High Power Programmable DC Power Supplies PVS Series

Keywords: RBC histogram, Peripheral blood smear, red cell disorders.

cobas connection modules (CCM) Sample flow solutions for high-throughput laboratories

Product Information Sheet UH36 Hi Pot Tester

Unleash Your Potential

Datasheet FUJITSU Storage ETERNUS LT250 TAPE LIBRARY

Multi-Range Programmable DC Power Supplies 9115 Series

1.44 kw Programmable DC Power Supplies XLN Series

Your Personal Pipetting Robot

Cedex Bio HT Bioprocess Analyzer. Be Confident. Be Assured.

cobas 6500 urine analyzer series Fully automated urine work area on a modular platform

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

NSFOCUS Remote Security Assessment System. Overview

Technical Data. FLIR T (incl. Wi-Fi)

Physical Specifications (Custom design available.)

MANUAL PC1000R

COULTER A C T diff COULTER A C T diff 2

Georgia Northwestern Technical College Practical Nursing Program CLINICAL DAILY ASSESSMENT WORKSHEET FOR MODULES I-IV STUDENT: CLINICAL INSTRUCTOR:

cobas connection modules (CCM) Sample flow solutions for high-throughput laboratories

DATASHEET FUJITSU ETERNUS LT250 TAPE LIBRARY

GSM GATEWAY PRI / E1 RACK 3U

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

YSI 2900 Series Biochemistry Analyzers FERMENTATION CONTROL FOOD & BEVERAGE CLINICAL RESEARCH

Cell Viability You Can Count On

R&S SMZ Frequency Multiplier Specifications

thyroid uptake systems

Technical Data FLIR E40bx (incl. Wi-Fi)

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Data Sheet FUJITSU Storage ETERNUS LT260 Tape System

PowerGem Pro Uninterruptible Power Supply

REAL-TIME DUST AND AEROSOL MONITORING

Product Information Sheet UH28CS-12kV Hi Pot Tester

RIEGL VQ-480. Airborne Laser Scanning. Airborne Laser Scanner with Online Waveform Processing. visit our website

MS9000SAN Rework Station

// SUPER technology for precise web viewing: SUPER HANDYScan Be inspired. Move forward.

KIP 2300 HIGH PRODUCTION CCD SCAN SYSTEM

Mitos P-Pump. product datasheet

Multi-Range Programmable DC Power Supplies 9115 Series

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

Peel Back Force Tester GPD s Peel Back Force Tester with FORCEWare software is being used to set peel back standards for the entire industry

for patient monitoring

GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER. Setting The Clinical Standard

Immunophenotyping peripheral blood cells

FDA Regulation of Whole Slide Imaging (WSI) Devices: Current Thoughts

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

USER'S GUIDE NUSCAN 2100 Series

SOUND LEVEL METER 94405

A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.

KNC Model 3666 Automatic Pressure Calibration System

Nardalert S3 Non-Ionizing Radiation Monitor

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

BROADCAST Trasmettitori / Transmitters DBH3 GAP FILLER

Sun Group Android Wi-Fi Digital Signage Touch Screen Series. SUN-SG8xxxxAS(W) SUN Group (Taiwan) -Android Touch Screen LCD Signage

THE UT880. Desktop Telephone. Empowering the Smart Enterprise.

Precision Lightmeters Made in Germany

CentraLink Data Management System

Agilent 4338B Milliohm Meter

MANUAL WBC LAB OBJECTIVE

ArtisanLink Staining System is an automated special stains slide

UGEO H60 PERFORMANCE IN STYLE

Microphone Test System

Accu-Chek Inform II system. Professional glucose testing for the wireless age

Basic Specifications. Electrical. EPSON Perfection Color EPSON MatrixCCD TM line sensor. device Effective pixels

digital quality control fail pass at your fingertips Smart Metrology Solutions.

DC Electronic Loads 8500 series

STORAGETEK SL150 MODULAR TAPE LIBRARY

Becton-Dickinson FACSCalibur Flow Cytometer Instructions

Laser Alignment Using the CSI 2140

KIP EXCEPTIONAL MULTIFUNCTION VALUE

Transcription:

Fully-automated Hematology Analyzer MEK-9100K

MEK-9100K Features : Linearity and Reproducibility : Simultaneous 33 parameter measurement Micro sampling capability Status indictor Walk away autoloader Homogeneous built-in tube mixing STAT/tube by tube sample analysis DynaHelix Flow technology DynaScatter Laser technology Smart ColoRac Match Integrated validation station with touch screen Reagent and controls bardoce management Color 10.4-inch LCD touch screen 3 different dilution measurements Automatic self-check, priming and nozzle cleaning Complete QC programs : L & J / Westgard Multi rule / XB(XBatch) management Access restriction with password Connection capability : RS232 / USB (Handy barcode, printer) / Handy barcode reader / Printer / LAN / HL7 Physical Specifications : Dimensions and Weight : Dimensions : 675 W 589 D 576 H mm Weight : approx. 66 kg Power Requirements : Line voltage : AC 100 to 240 V ±10% AC, 50/60 Hz Power input : max 330 VA Sound Pressure Level : < 85dB Parameters : WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, PCT, MPV, PDW, P-LCR, NE, NE%, LY, LY%, MO, MO%, EO, EO%, BA, BA%, P-LCC*, Mentzer Index*, RDWI*, IG%*, IG#*, Band%*, Band#*, Seg%*, Seg#* (*) RUO parameters (Research Use Only) Throughput : Auto and manual measurement up to 90 samples/hour Patient memory capacity : 10,000 patient with graphs Sample Volume : CBC : 25 μl CBC+DIFF : 40 μl Pre-dilution mode : 20 μl Barcode Format : Acceptable formats with or without check digits : Industrial 2 of 5, ITF, JAN/EAN/UPC, NW-7, CODE 39, CODE 93, CODE 128 Methods and Technologies : WBC, RBC, PLT : Electrical resistance (DynaHelix Flow technology) HGB : Colorimetric method (surfactant method) HCT : Calculated from RBC histogram WBC differentiation : Light scatter by laser (DynaScatter Laser technology) MCV, MCH, MCHC : Calculated from RBC, HGB and HCT PCT : Calculated from PLT histogram MPV : Calculated from PLT and PCT RDW-CV, RDW-SD : Calculated from RBC histogram PDW and P- LCR : Calculated from PLT histogram WBC population : Calculated from scattergram Precision (Reproducibility) WBC : 2.0% or less (WBC : 4.00 10 3 /μl or more) RBC : 1.5% or less (RBC : 4.00 10 6 /μl or more) HGB : 1.5% or less HCT : 1.5% or less MCV : 1.0% or less PLT : 4.0% or less (PLT : 100 10 3 /μl or more) NE% : 5.0% or less (NE% : 30.0% or more AND WBC : 4.00 10 3 /μl or more) LY% : 5.0% or less (LY% : 15.0% or more AND WBC : 4.00 10 3 /μl or more) MO% : 12.0% or less (MO% : 5.0% or more AND WBC : 4.00 10 3 /μl or more) EO% : 20.0% or less OR within ±1.0 EO% (WBC : 4.00 10 3 /μl or more) BA% : 30.0% or less OR within ±1.0 BA% (WBC : 4.00 10 3 /μl or more) NE : 8.0% or less (NE : 1.20 10 3 /μl or more) LY : 8.0% or less (LY : 0.60 10 3 /μl or more) MO : 20.0% or less (MO : 0.20 10 3 /μl or more) EO : 25.0% or less OR within ±0.10 10 3 /μl (WBC : 4.00 10 3 /μl or more) BA : 30.0% or less OR within ±0.10 10 3 /μl (WBC : 4.00 10 3 /μl or more) (Specifications above applies to normal mode) Linearity WBC : within ±3.0% OR ±0.3 10 3 /μl (WBC : 0.20 to 99.9 10 3 /μl) RBC : within ±3.0% OR ±0.08 10 6 /μl (RBC : 0.02 to 8.00 10 6 /μl) HGB : within ±1.5% OR ±0.2 g/dl (HGB : 0.10 to 25.0 g/dl) HCT : within ±3.0% OR ±1.0% (HCT : 20.0 to 60.0%) PLT : within ±10.0% OR ±20 10 3 /μl (PLT : 10 to 1490 10 3 /μl) (Specifications above applies to normal mode) Safety Standards Certification : IEC 60825-1 : 2014 IEC 61010-1 : 2001 IEC 61010-2-101 : 2002 IEC 61326-2-6 : 2005 EN 55011 : 2002 Group 1 Class B EN 60825-1 : 2014 EN 61010-2-101 : 2002 EN 61326-2-6 : 2006 EMC Standards : IEC 61326-2-6 : 2005 EN 55011 : 2002 Group 1 Class B EN 61326-2-6 : 2006 Environmental Conditions : Operating temperature : 15 to 30 C (59 to 86 F) Operating humidity : 30 to 85% Operating atmospheric pressure : 700 to 1060 hpa SD is a trademark of SD-3C, LLC. This brochure may be revised or replaced by Nihon Kohden at any time without notice. 8398 CAT.No.65-012 16.2.SE.E Printed in Japan

Celltac G Smart ColoRac Match helps fast and easy location of clinically abnormal tubes as well as scan-failed barcoded tubes using the unique color-coded rack system that is associated with data management software on the analyzer. This unique user-oriented Smart ColoRac Match system enhances lab's efficiency without extra investment, extra space and special operator training. The Smart ColoRac Match surely maximizes lab s productivity for faster and more accurate test report. P : There are some items determined as positive E : Measurement error B : Barcode error

Transforming the possibility of IVD solutions Complete hematology platform offering: Up to 90 samples per hour 33 parameters Micro sampling capability Continuous loading of samples via rack fed system up to 7 racks of 10 tubes STAT/manual sample analysis Laser scatter + flow cytometry technology Built-in rocking mixing Smart ColoRac Match system Integrated validation station with touch screen Reagent and controls management with barcode Status indicator Homogeneous tube mixing STAT mode Celltac G status indicator is located in the front panel and clearly illustrates different operating status of the analyzer. For example, the operator can quickly recognize the need for reagent replacement by just looking at the status indicator turning red. Each tube is picked up one by one from color-coded racks and gently mixed with built-in complete tube inversion mixing arm. Our auto-loading system contributes to faster test report to clinical decision makers and enhances workflow efficiency. STAT and Pre-dilution modes analyze micro-samples such as pediatric blood collected from the earlobe or fingertip. Celltac G provides solutions based on the true laboratory needs.

Innovation for superior reliability The DynaHelix Flow technology perfectly aligns WBC, RBC and PLT cells for high impedance counting precision using advanced hydrodynamic-focused sheath flow before passing through the aperture. In addition, the DynaHelix Flow totally prevent risk of coincidence or count of blood cell re-entry into the aperture using unique DynaHelix Flow stream. This newly-developed advanced DynaHelix Flow technology greatly improve counting precision and accuracy. Celltac G s DynaScatter Laser optical technology truly analyzes and differentiates WBCs in near-native state. The innovative 3 angle scatter detector provides better detection of WBCs using precise light scattering measurement. We obtain WBC size information from a small forward angle (FSS), information of cell structure and complexity of nucleo-chromatin particles from a large forward angle (FLS), and internal granularity and globularity information from a side angle (SDS). This 3D graphic information is calculated by the exclusive Nihon Kohden software algorithm. Solutions simplifying your daily work Celltac G s fully-automated random access walk away loading system enables up to 90 tests per hour by just continuously inserting the color-coded racks on the system. Celltac G s HL7 based information system enables seamless bi-directional information transfer to laboratory information systems.

Celltac G reports 33 parameters at once in 40 seconds just with 40μL of whole blood. Newly-added RDWI and Mentzer Index provide clinically-valuable information for differentiating B-thalassemia trait possibility or iron deficiency anemia possibility in microcytic anemia cases. Also both P-LCR and P-LCC parameters provide information for possible giant platelet, platelet aggregation, or fragment cell presence. These new parameters help faster clinical decision making as well as more accurate diagnosis. Quality first Celltac G s reagent management system helps easier reagent bottle management. With this feature, testing quality is always maintained at high standard level. Celltac G provides complete traceable QC records that meet laboratory accreditation requirements. In addition, reagent management report, maintenance report, calibration history report, analyzer s daily self-check report and many other reports or logs are always stored using internal memory for evidence of compliance for laboratory accreditation requirements.