Y800 Plus Digital Panel Meter for Load Cell & Microvolt Input

Similar documents
WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Experiment 5. Strain Gage Measurements

NC-12 Modbus Application

Contents. Document information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

PIEZOMETER AIRFLOW MEASURING RING

1.44 kw Programmable DC Power Supplies XLN Series

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Digital Pressure Measuring Instrument MDR480

Centro-Matic Automatic Lubrication Systems System Controls

Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) Tel: (203) Fax: (203)

Application/Connection Examples

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Digital and Analog I/O

Wahl C50 Calibrator FEATURES

PRODUCT PROFILE FEATURES

DPI 260 SERIES: Digital Pressure Indicators

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Temperature & Humidity SMS Alert Controller

WEB log. Device connection plans

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Multi-Range Programmable DC Power Supplies 9115 Series

Panel Meters and Controllers Modular Panel Meter Type EDM 35

DCS Series 1 kw, 1.2 kw, & 3 kw

How To Use A Ds340 (Dsp)

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Quick Connect. quick - simple - efficient.

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

sigpod Press ASSEMBLY PRESS-FIT MONITORING SYSTEM BENEFITS FEATURES

Physical Specifications (Custom design available.)

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

AIS750 Series Alarm Annunciator

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Telefon (+45) Telefax (+45) Installation and operating manual

LOXONE 12 Channel Amplifier

40.3. Control Relays and Timers

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Product Information Sheet UH28CS-12kV Hi Pot Tester

Safety technique. Emergency stop module BO 5988 safemaster

High Power Programmable DC Power Supplies PVS Series

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Impedance 50 (75 connectors via adapters)

Duct Humidity Transmitter

Modular I/O System Analog and Digital Interface Modules

FREQUENCY RESPONSE ANALYZERS

WEB log. Device connection plans

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Model: DC-A2IO Advanced HVAC Controller

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Remote Sources. Facility. Router

PPM Users Manual Signature Software

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

1. SAFETY INFORMATION

User's Guide. Integrating Sound Level Datalogger. Model Introduction

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

PCS0100en Persy Control Services B.V. Netherlands

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

1 Serial RS232 to Ethernet Adapter Installation Guide

EDI Distributor Control Interface Wiring and Setup Instructions

Thyristor-controlled power supplies and battery chargers

Multi-Range Programmable DC Power Supplies 9115 Series

SYSTEM 4C. C R H Electronics Design

How To Use A Ci 2001A/B (I2) With A Power Supply (I3)

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Preliminary. Dual-line FLOW rate/totalizers. Pr ovu Model PD6200 Analog Input. Pr ovu Model PD6300 Pulse Input. Analog Inputs.

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

In regard to calculating system power requirements, refer to DBK Basics located near the front of this manual.

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

DC Electronic Loads 8500 series

Innkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio

NEW. EVEN MORE data acquisition and test stand automation

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Measuring Temperature withthermistors a Tutorial David Potter

Integrating Sound Level Meter and Datalogger

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Flow Monitoring System

IntesisBox KNX Modbus TCP master

Temperature Transmitters ZTT series

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

NETWORK ENABLED EQUIPMENT MONITOR

Transcription:

. Y800 Plus Digital Panel Meter for Load Cell & Microvolt Input Description Features The Y800 Plus load cell & microvolt meter is a high-sensitivity monitor and controller for use with load cells, strain gauges and microvolt input signals where high accuracy and stability are required. DC microvoltmeter operation provides sensitivity down to ±20 mv full scale with 1 µv resolution. A display span of 99,999 counts with sensitivity of 0.2 µv per count can be obtained by applying a digital multiplier of five. A moving average digital filter assures quiet readings in electrically noisy environments. Load cell operation allows six-wire hookup and scaling for direct readout in engineering units, such as pounds, kilograms or PSI. Scaling can be via front panel pushbuttons or a computer. Zero may be set from -99,999 to +99,999. Range may be scaled from 0 to ±99,999. Digital scaling and calibration eliminate drift caused by potentiometers in nonmicrocomputer based meters. Meter accuracy is 0.01% of full scale ± 2 counts with an ideal load cell. Custom curve linearization, which is available with the optional Extended main board, can extend the working range of real-world load cells. Custom curve linearization also allows high accuracy to be achieved with lower cost, less linear load cells. A built-in isolated 10 Vdc excitation supply can provide up to 120 ma of current at 10V to power four 350-ohm load cells in parallel. The meter operates in a ratiometric mode to eliminate errors due to supply variations. When excitation sense inputs are used in 6-wire connection, the meter compensates for variation in resistance of the transducer leads to allow long cable runs. High read rates at up to 60 or 50 conversions per second while integrating the signal over a full power cycle are provided by Concurrent Slope (US Pat 5,262,780) analog-to-digital conversion. High read rates are ideal for peak or valley capture, realtime computer interface, and control. Peak and valley values are automatically captured. These may be displayed via a front panel pushbutton or control signal at the rear connector, or be transmitted as serial data. 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999 Selectable fixed right-hand zero with rounding Isolated 10 Vdc supply to power up to four 350-ohm load cells in parallel 4- or 6-wire hookup to avoid lead resistance effects 1 Gohm input impedance Up to 60 conversions per second Peak or valley display Auto-tare with tare value stored in memory Universal AC power, 85-264 Vac 1/8 DIN case sealed to NEMA-4X from front panel Optional serial I/O: Ethernet, USB, RS232, RS485, Ethernet-to-RS485 converter Optional relay output: dual or quad relays, contact or solid state Optional isolated analog output: 4-20 ma, 0-20 ma, 0-10V, -10 to +10V Optional low voltage power: 10-48 Vdc or 12-32 Vac Digital filtering is selectable for electrically noisy environments, including a batch averaging filter and an adaptive moving average filter which provides a choice of 8 time constants from 80 ms to 9.6 s. When a significant change in signal level occurs, that filter adapts by briefly switching to the shortest time constant to follow the change, then reverts back to the selected time constant. In a selectable Auto filter mode, the filter time constant is automatically selected based on detected signal noise. Easy scale and offset are provided by Y800 Plus DC, process and load cell meters by either of two selectable methods: With the coordinate reading method, the meter reads the high and low signal values, and the user enters the desired high and low reading values. The meter then calculates the span multiplier and offset. This method is ideal if an external calibration reference is available. With the manual coordinate method, the user enters the high and low input values in Volts plus the desired high and low reading values. This method is suitable if no external calibration reference is available. Auto-tare is standard for weighing applications to subtract the weight of an empty container and may be controlled by an external pushbutton contact closure or a logic signal. Additional capabilities for weighing applications are provided by the Y800 Plus weight & scale meter. Designed for system use. Optional plug-in boards include Ethernet and other serial communication boards, dual or quad relay boards, and an isolated analog output board. Y800 Plus meters may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with red or green LEDs. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A built-in isolated 5, 10, or 24 Vdc excitation supply can power transducers and eliminate the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs.

Specifications DC Microvolt Input Input Range, mv Resolution Input Resistance Error at 25 C Load Cell Input ±20.000 ±50.000 ±100.00 ±250.00 ±500.00 1 µv 1 µv 10 µv 10 µv 10 µv 1 GΩ 0.01% FS ± 2 counts Full-Scale Input, mv Zero Adjust Span Adjust Input Resistance Error at 25 C ±20.000 ±50.000 ±100.00 ±250.00 ±500.00 DC Microvolts & Load Cell -99,999 to +99,999 0 to ±99,999 1 GΩ 0.01% FS ± 2 counts Accuracy Error at 25 C Span tempco Zero tempco Load cell linearization Noise Rejection CMR, DC to 60 Hz NMR at 50/60 Hz A-to-D Conversion Technique A-to-D rate Output update rate Display update rate Display Readout Range Indicators Power Voltage, standard Voltage, optional Frequency Power isolation Excitation Output (standard) Selectable levels Output isolation Analog Output (optional) Output Levels Current compliance Voltage compliance Scaling Resolution Isolation Relay Outputs (optional) Relay types Current ratings 0.01% FS ± 2 counts 0.0015% of reading/ C 0.1 µv/ C Provided by Extended meter version 130 db 90 db with min filtering Concurrent Slope (Pat 5,262,780) 60/s at 60 Hz, 50/s at 50 Hz 56/s at 60 Hz, 47/s at 50 Hz 3.5/s at 60 Hz, 3/s at 50 Hz 5 LED digits, 7-segment, 14.2 mm (.56"), red or green. -99999 to 99999 or -99990 to 99990 (count by 10) Minus sign, 2 red LED lamps 85-264 Vac or 90-300 Vdc (DC operation not UL approved) 12-32 Vac or 10-48 Vdc DC or 47-63 Hz 5 Vdc ± 5%, 100 ma; 10 Vdc ± 5%, 120 ma; 24 Vdc ± 5%, 50 ma 50 Vdc to meter ground 4-20 ma, 0-20 ma, 0-10V, -10 to +10V (jumper selectable) 2 ma at 10V ( > 5 kohm load) 12V at 20 ma ( < 600 Ohm load) Zero and full scale adjustable from -99999 to +99999 16 bits (0.0015% of full scale) 2 Form C contact relays or 4 Form A contact relays (NO), 2 or 4 Form A, AC/DC solid state relays (NO) 8A at 250 Vac or 24 Vdc for contact relays 120 ma at 140 Vac or 180 Vdc for solid state relays

Output common Isolation Serial Data I/O (optional) Board selections Protocols Data rates Digital addresses Isolation Signal Connections Isolated commons for dual relays or each pair of quad relays Ethernet, Ethernet-to-RS485 server, USB, USB-to-RS485 server, RS485 (dual RJ11), RS485 Modbus (dual RJ45), RS232. Modbus RTU, Modbus ASCII, Custom ASCII protocol 300 to 19200 baud 247 (Modbus), 31 (Custom ASCII) Environmental Operating temperature Storage temperature Relative humidity Protection 0 C to 55 C -40 C to 85 C 95% at 40 C, non-condensing NEMA-4X (IP-65) when panel mounted Load Cell Meter Connections In 4-wire connection, the excitation and sense lines are tied together. The meter can make ratiometric corrections for supply voltage variations, but not compensate for variations in lead resistance. This connection is often used with short cable runs. In 6-wire connection, the sense lines are separate from the excitation lines, thereby eliminating effects due to variations in lead resistance. This allows long cable runs in outdoor environments with temperature extremes. For large scales, up to four 350 ohm load cells can be powered by a single Y800 Plus meter, whose excitation output is rated 120 ma at 10 V. The excitation and sense points of the four bridges are connected in parallel through a summing box.

Seat belt tensile strength testing using Y800 Plus digital panel meters. The three meters display Force, Displacement and Speed. Sample Applications Auto-Tare To read the net weight of an object, the empty container is first weighed, and an external button is pushed to zero out the display. The meter will then read net weight when an object is added to the empty container. The tare value is stored in memory for subsequent readings. Determining Volume Using Load Cells An easy way to determine volume of an irregularly shaped tank with no need for linearizing is to weigh the tank using load cells. The meter will automatic- ally tare out the weight of the empty tank and then scale the load cell signals to units of volume, such as liters or gallons. Peak Capture for Tensile Strength of Wire Peak readings are automatically captured at rates up to 60 per second, while the display updates at a legible 3.5 per second. The peak reading can be recalled at the push of a button or be always displayed. It can also be transmitted to a computer via RS232, RS485., USB, or Ethernet.

Mechanical

Ordering Guide Create a model a model number in this format: Y810000WM, IPC DPM Type Main Board Y8 Y800 Plus Digital Panel Meter 1 Standard Main Board, Green LEDs 2 Standard Main Board, Red LEDs 3 Extended Main Board, Green LEDs 4 Extended Main Board, Red LEDs Note: Extended capability is only required for custom curve linearization or for display of time rate of change, such as flow rate from changing tank weight. Power Relay Output Analog Output Digital Interface Signal Input 0 85-264 Vac 1 12-32 Vac or 10-48 Vdc 0 None 1 Two 8A Contact Relays 2 Two 120 ma Solid State Relays 3 Four 8A Contact Relays 4 Four120 ma Solid State Relays 0 None 1 Isolated 4-20 ma, 0-20 ma, 0-10 V, -10 to +10V 0 None 1 RS232 2 RS485(dual RJ11 connectors) 4 RS485 Modbus (dual RJ45 connectors) 5 USB 6 USB-to-RS485 device server 7 Ethernet 8 Ethernet-to-RS485 device server Load Cell (6-wire ratio) WM Field Scalable. Default scaling is 0-20 mv = 0-100.00 WM1 Custom Scaling. In the write-in field of your order, specify min input, min reading; max input, max reading. Full-scale input is 20-500 mv. Excitation is 10 V for up to four 350-ohm load cells. Add-on Options BL Blank Lens without Button Pads CBL01 RJ11-to-DB9 Cable CBL02 USB-to-DB9 Adapter CBL05 USB Cable, A to B IPC Splash-proof Cover BOX1 NEMA-4 Enclosure BOX2 NEMA-4 Enclosure plus IPC