POWERED BY OPTEST SOFTWARE. LensCheck Lens Measurement Systems

Similar documents
Fig.1. The DAWN spacecraft

Optical laser beam scanner lens relay system

From Pixel to Info-Cloud News at Leica Geosystems JACIE Denver, 31 March 2011 Ruedi Wagner Hexagon Geosystems, Geospatial Solutions Division.

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

Endoscope Optics. Chapter Introduction

Rodenstock Photo Optics

The Wide Field Cassegrain: Exploring Solution Space

digital quality control fail pass at your fingertips Smart Metrology Solutions.

Automatisierte, hochpräzise Optikmontage Lösungen für die Industrie

ID Objective Requirements Description of Test Date & Examiner 15 Verify that the optics?? OMC

A NEW LOOK AT RISLEY PRISMS. By Craig Schwarze Senior Systems Engineer OPTRA Inc.

Flat-Field IR Mega-Pixel Lens

Untangling the megapixel lens myth! Which is the best lens to buy? And how to make that decision!

Rodenstock Photo Optics

Infrared Viewers. Manual

Dynamic IR Scene Projector Based Upon the Digital Micromirror Device

LEICA TRI-ELMAR-M mm f/4 ASPH. 1

Module 13 : Measurements on Fiber Optic Systems

Technical Specifications

Performance testing for Precision 500D Classical R/F System

How to Measure MTF and other Properties of Lenses

Nederland België / Belgique

Realization of a UV fisheye hyperspectral camera

Imaging techniques with refractive beam shaping optics

T-REDSPEED White paper

Optical System Design

MRC High Resolution. MR-compatible digital HD video camera. User manual

Fisheye lens designs and their relative performance

First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between

Synthetic Sensing: Proximity / Distance Sensors

hsfc pro 12 bit ultra speed intensified imaging

The best lab standard. 1,4 Megapixels 2/3 inch sensor Giant pixel size 6 times optical zoom Massive 16-bit imaging for enhanced dynamic

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

Diffraction of a Circular Aperture

SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC

Product Range Overview

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002

INDUSTRIAL VISION. Don Braggins, UK Industrial Vision Association

WHITE PAPER. Are More Pixels Better? Resolution Does it Really Matter?

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

Phoroptor VRx Digital Refraction System

Sviluppo di componenti per sottosistemi ottici basati su ottiche elettroformate altamente asferiche per applicazioni Spazio e Difesa

Profile Projector PH-3500

Laserlyte-Flex Alignment System

Tube Control Measurement, Sorting Modular System for Glass Tube

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

D/N VARI-FOCAL IR CAMERA

Understanding astigmatism Spring 2003

Guideline Laser Series

2) A convex lens is known as a diverging lens and a concave lens is known as a converging lens. Answer: FALSE Diff: 1 Var: 1 Page Ref: Sec.

Understanding Line Scan Camera Applications

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

Master Anamorphic T1.9/35 mm

Detachable DIY Door Viewer Camera for Home / Office Safety. Installation Manual. (* This is a patented product, do not copy) IA Technologies Inc.

ZEISS T-SCAN Automated / COMET Automated 3D Digitizing - Laserscanning / Fringe Projection Automated solutions for efficient 3D data capture

18-270mm F/ Di II VC PZD for Canon, Nikon (Model B008) mm F/ Di II PZD for Sony (Model B008)

Technical Data. FLIR T (incl. Wi-Fi)

Temperature. LumaSense Technologies, Inc. supplies a unique selection of very precise calibration

microscope OP-Dent-5

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

Agilent Cary 4000/5000/6000i Series UV-Vis-NIR

Efficiency, Dispersion and Straylight Performance Tests of Immersed Gratings for High Resolution Spectroscopy in the Near Infra-red

Arrayoptik für ultraflache Datensichtbrillen

Refractors Give the Best Planetary Images

Large FOV Mobile E-O Telescope for Searching and Tracking Low-orbit Micro-satellites and Space Debris

SpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II

Full Waveform Digitizing, Dual Channel Airborne LiDAR Scanning System for Ultra Wide Area Mapping

Calibration of a High Dynamic Range, Low Light Level Visible Source

Zoom Lens Design of Mobilephone Camera with Global-Explorer Optimization

Theremino System Theremino Spectrometer Technology

Autoguiding Advanced Techniques

Basler. Area Scan Cameras

AxioCam HR The Camera that Challenges your Microscope

TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions

Holographically corrected microscope with a large working distance (as appears in Applied Optics, Vol. 37, No. 10, , 1 April 1998)

Using visible SNR (vsnr) to compare image quality of pixel binning and digital resizing

OPTICAL MEASURING MACHINES

VICKERS HARDNESS TESTER. HBS HBW Kc

Warning : HαT telescope must NOT be used for solar observation without additional filters. This is the user responsibility to check that his filter

Color holographic 3D display unit with aperture field division

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

Camera Technology Guide. Factors to consider when selecting your video surveillance cameras

PlaneWave CDK Telescope Instructions CDK12.5, 17, 20 and 24

Diffraction of Laser Light

Alignment Laser System.

THE COMPOUND MICROSCOPE

Filters for Digital Photography

DSLR Astrophotography

2WIN Binocular Mobile Refractometer and Vision Analyzer

Optilia Instruments. Empowering Your Vision!

Video Camera Image Quality in Physical Electronic Security Systems

VIDEO. Video_Flir_131125

Physics 441/2: Transmission Electron Microscope

AF 70~300 mm F/4-5.6 Di LD Macro 1:2 (Model A17)

Today. next two weeks

Apo-Nikkor and Process-Nikkor large format lenses by Daniel W. Fromm

Transcription:

POWERED BY OPTEST SOFTWARE LensCheck Lens Measurement Systems

LensCheck Lens Testing Systems Portable and Precise for VIS/NIR through LWIR Lens Measurements A cost-effective solution to your production and prototype lens qualification needs. Optikos, the leader in image quality test equipment, is pleased to offer this compact, efficient, easy-to-use quality control tool. LensCheck, with patented Optikos VideoMTF image analysis software, features real-time MTF testing and analysis that allow manufacturers to qualify incoming products quickly and reliably, thereby minimizing the risks of sub-standard complete assemblies. APPLICABLE LENSES FOR TESTING: The suitability of the LensCheck VIS for testing a visible wavelength lens depends primarily on: Specification VIS LWIR Entrance pupil diameter up to 50 mm up to 50 mm Focal length f-number of the lens 3-200mm (with appropriate image analyzer objective lens) f/20 f/1 (with appropriate image analyzer objective) The suitability of fast, non-telecentric lenses at offaxis field angles is determined by whether the image cone falls within the acceptance cone of the image analyzer objective. 5-50 mm f/20 - f/1 Image format size up to 25 mm image diagonal up to 25 mm image diagonal Other characteristics that factor into the determination are: spatial frequency of interest chromatic performance of the lens departure from telecentricity at off-axis angles These parameters are seldom independent, making it difficult to place rigid bounds on the space of lenses that may be tested on LensCheck isntruments. However, it is generally true to say that lenses that fall within the bounds given above are usually good candidates for testing with this instrument. There may be some special case in which lenses within these bounds may not be suitable for testing, and there are certainly cases in which lenses outside of these bounds may be tested. When in doubt, consult an Optikos engineer for advice. APPLICABLE MEASUREMENTS: MTF on/off axis EFL and f-number Back focal length Astigmatism Field Curvature Distortion Transmission (VIS optional) Relative illumination (VIS optional) Line of Sight (VIS/LWIR optional) Veiling glare (VIS with optional instrument)

FEATURES: Patented VideoMTF technology enables real time MTF measurements Flexible platform allows a wide range of measurements (e.g. MTF, EFL, distortion) VIS - industry leading measurement accuracy better than 2% (1% typical); and better than 1% (0.5% typical) repeatability each validated with 50mm F/5 Audit Lens) LWIR - industry leading measurement accuracy better than 3% (2% typical) to 40 lp/mm; and better than 2% (1% typical) repeatability each validated with 50mm F/5 Audit Lens) Configurable automated measurement routines Installed in production and R&D facilities around the world SPECIFICATIONS Physical Size: Power Requirements: Environmental: Refractive Collimator Source Module 15 (355mm) H 30 (762mm) W 48 (1219mm) L 100~240VAC 60/50Hz Computer 8/5A, Monitors 0.6A each, DC Power Supply 1.6A, Light Source 2/1A Optimal performance is achieved in a dark room 355 mm EFL, 50mm clear aperture VIS - Fiber-optic light source: 400-700nm 8-position manual target and filter wheels Target set: pinholes, USAF 1951, and alignment target Filter set: photopic, 546nm bandpass, infrared cutoff, and RGB set LWIR - Broadband Emitter: 7-15 microns 12-position high-speed motorized target wheel Target set: slits, pinholes, crosshairs, and alignment target 8-12 micron bandpass filter Image Analyzer VIS - Sony EXview HAD CCD II offers improved sensitivity, dynamic range, and noise characteristics 2736 x 2192 pixels 12-bit video output Calibrated 40x 0.65NA achromatic objective LWIR - Uncooled Microbolometer 324 x 256 format Spectral sensitivity 7.5-15 microns Calibrated 7.5x 0.70NA relay lens Motorized Z-axis Motorized X-axis Manual Y-axis Motorized Lens Platform 25 mm travel 0.1 μm resolution 25 mm travel with 0.05 μm resolution glass scale encoder 12.5 mm travel +/- 100 off-axis rotation 0.0001 resolution glass scale encoder 0.5m optical rail Self-centering lens mount

Options Audit Lens Transmission Kit Veiling Glare Instrument Finite Conjugate Instrument available as a LensCheck option or standalone unit Achromatic Objectives Reflective Collimator* Apochromatic Objective* Lens Mounts: supplied with standard three-jaw caliper lens holder for lenses with diameters in 5-25 mm range. For best results, we suggest using available lens mount for specific mounting interfaces. A partial list of available adapters includes the following: M7 through M12, C-Mount, T-Mount, Nikon F-Mount, etc. Spectral Filters Optical Rail custom configurations are available upon request ROTARY LENS MOUNT (VIS) Motorized lens mount accommodates varying diameter lenses; lense can be measured for centration and optical axis runout TRANSMISSION KIT (VIS) Transmission measurements: Measure sphere irradiance with or without UUT Accuracy of 0.1% validated using Reference Lens with uncoated window VEILING GLARE INSTRUMENT (VIS) Stray Light measurements per ISO 9358 Black dot surrounded by uniform bright field Validated with Reference Lens down to 0.1%

FINITE CONJUGATE LENS MEASUREMENT INSTRUMENT (VIS) The Finite Conjugate Measurement Instrument is available as a standalone unit, or as an option for the LensCheck VIS. When used as a LensCheck add-on option for measuring finite distances, the LensCheck Image Analyzer (IA), IA Mount, Rail and Lens Mount are removed from the LensCheck unit and mounted to the instrument base below. The image may then be moved to a precise location on the rail, and may be moved off axis. Manual Z-axis: 500mm travel with 0.01mm resolution encoder Motorized X-axis: 500mm travel with 0.1mm resolution Footprint: 53 x 30 (134.6x76.2cm) Approximately 80 lbs (36.4 kg) REFLECTIVE COLLIMATOR (LWIR) Infrared emitter: 1000 degrees C Uncooled microbolometer: spectral response 7.5-14 microns APOCHROMATIC OBJECTIVES (LWIR) Infinity corrected 10X, 20X, and 40X objectives with tube lens suitable for broadband Get Started with Optikos Optikos offers engineering design and manufacturing, and a full-line of metrology products and services for testing optical, imager and camera systems that are appropriate for any industry--or we will design a custom product for your specific needs. Visit our website at optikos.com or contact us to help you choose the right optically-based solution for your application. Optikos Corporation 107 Audubon Road, Bldg. 3 Wakefield, MA 01880 USA Phone: +1 617.354.7557 Email: sales@optikos.com Web: www.optikos.com

DATE OF ISSUE: 02.01.2016