Trus <T> Lift Options and their purpose

Similar documents
V1504 Vertical Platform Lift OWNER S MANUAL

Walking and Working Surface Checklist:

V1504 Vertical Platform Lift OWNER S MANUAL

Group TRAFFIC MANAGEMENT SPECIALIST ACCESS WAY SOLUTIONS CREATIVE SOLUTIONS TO COMMON CHALLENGES. Products

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

RADAR

Section 7: Elevators and Lifts. Main Entry Floor Outside the Elevator

PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE

INSTRUCTIONS: LocknCharge Laptop Carts

19 DYNAmax Free Standing Server C A B I N E T s

19 DYNAmax Free Standing Server C A B I N E T s

Work Smart - Not Hard with a Blue Giant Lift Table

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

Small form factor bay converter and hard drive installation

The KONE Motala 2000 platform lift suits the architecture of any building, thanks to the wide range of car and shaft design options.

AD425S Automatic door operator

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

Automatic Door Selection Guide

Speed-Mat Rectangle Cutter

HEAVY DUTY STAIR LIFT SYSTEM Installation and Service Manual

SETTING UP YOUR 6000 SERIES TIME RECORDER

Introduction Body Specifications Technical Data Body Interior Rear Seats Center Arm Rest Child Seat Restraint...

AUSTRALIAN HUMAN RIGHTS COMMISSION NOTICE OF DECISION ON APPLICATION FOR TEMPORARY EXEMPTIONS: AUSTRALASIAN RAILWAY ASSOCIATION

ACCESS AUDIT OF WESTPORT HOUSE

GEK-90214B. GE Lift Truck. User s Guide 144D2933G1 144D2912G1 144D2911G5

SERVICE MANUAL. Corpus 3G. Seat system for electric wheelchair

Kitchen Planning Guidelines With Access Standards

DIRECTIONS FOR ASSEMBLING BASE & WALL CABINETS

Base Cabinet with Self-storing Folding Doors and Floor

Roof Tutorial. Chapter 3:

INSTALLATION MANUAL XM3 Reader

CYBEX GmbH Riedinger Str Bayreuth Germany.

OPTIONS Living Collection and Prime Series

(B613) VERTICAL PLATFORM LIFT PLANNING GUIDE

Max load: 450/625lbs, 205/285kg

P.A.L. S SPECIFICATIONS

American Academy of Physical Medicine and Rehabilitation Site Survey Report

Disabled Access Guide

Proper Use of Industrial Scissors Lifts As Personnel Work Platforms

19 NETbox SOHO Network Wall Mounting Cabinets FAMILY

MEGA GUARD COLUMN CORE GUARD DAWG COLUMN PROTECTOR. Smart Investments in Plant Safety

CONSULTANT PROCEDURES & DESIGN GUIDELINES ACCESS CONTROL SYSTEM

User Manual CN2HK LIMITED. Complete Wireless Home Alarm Security System (CK-8806) ENG. Please read this manual before operating this product.

OWNER S MANUAL. Permolock C3. Docking system for Power wheelchair in vehicle

AUTOMATIC OPENER SYSTEM FOR OUTSWING RESIDENTIAL GARAGE DOORS. Exclusively by:

City of Wichita, Kansas Americans with Disabilities Act Transition Plan Main Library Address

ATS - Automatic Changeover

Guarding Floor and Wall Openings and Holes OSHA Standard

Interlocking Door Systems Automatically protecting your staff and property

SHIFT INTERLOCK SYSTEM SHIFT INTERLOCK SYSTEM

INSTALLATION INSTRUCTIONS

ELIGIBILITY APPLICATION

ADA Checklist for Polling Places

Utility Distribution Systems

VEHICLE EQUIPMENT INSTRUCTIONS

Accessibility Design Advice

THE UNIVERSITY OF EDINBURGH OLD COLLEGE

Simplified Steel Stair Design for Commercial and Institutional Buildings

From the Smallest Part to Turn-Key Rods!

Crime Prevention through Environmental Design (CPTED) - Checklist

*TTVF : 4&3*&4 $&/563 NCL2

COMMONLY USED RESIDENTIAL BUILDING CODES

Model 2300DR Installation Guide

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Pentalift Equipment Corporation Lift table and positioning equipment glossary of terms

Main Library Meeting Room Use

Coyote popup features

Alarm Security Kit - NVR

PALLETS ROLLER CONVEYOR LOADING CONVEYOR CHAIN TRANSFER TURNTABLE ROLLER STOP

Contractors Guide Central Inverter System Installation

THE UNIVERSITY OF EDINBURGH. ECA Evolution House.

Operating, Installation, and Maintenance Instructions

Installation Instructions

Basic Spring Motor Roller Shades

ADA Guide for Small Businesses

Lift and Escalator Installations

Integral Shading & Privacy Solutions

Fire. The Fire Installers Mate. A guide to fire alarm systems design

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

MOVING YOU FURTHER HYUNDAI HEAVY INDUSTRIES

General Guidelines. Neck Stretch: Side. Neck Stretch: Forward. Shoulder Rolls. Side Stretch

Handicapped Accessible Home. By: Kevin and Zachary Smith

DIY CABINET REFACING INSTALLATION GUIDE

Expanding Your Market

glass & Glazing Products

GENERAL + MEANS OF ESCAPE (Part One) By Mdm Eng Yew Hoon (SIA)

CordlessPleated FabricShade including Top-Down/Bottom-Up. owner's handbook

Master Code 2. Troubleshooting: Installation 7. Troubleshooting: Door Jamming and Door Handing 8. Troubleshooting: Keypad 12

Alliance System Ordering Guide


Coyote popup features

Ceiling Mounted Folding Attic Ladders Installation Instructions

Instructions for assembly of your Pop-Up Display

STORAGE DESIGN LIMITED

Cooktop Low-Profile Ventilation Hoods

Introduction. Pre-Arrival. Arrival & Car Parking Facilities. Main Entrance, Reception & Ticketing Area

SOME HELP WITH BRITISH STANDARD BS EN 1570:1999 Safety requirements for lifting tables

Transcription:

Trus <T> Lift Options and their purpose

Interlocks (Electrical/Mechanical ) Purpose: Ensures that doors or gates remain closed and locked until the lift is position to receive or discharge the rider. Prevents access to the Hoistway when lift is in operation. The interlock is a 2 piece (Male & Female) locking mechanism that mounts to doors or gates. Typically preinstalled during the production of RAM doors or gates. Interlocks can also be purchased separately and mounted to client supplied doors or gates. Typical Interlock Installation Example Note: Interlocked doors and gates may be required by code in your area. Always consult with your local authorities. Interlock Style May Vary Remote Call Stations Purpose: Remote Call Stations are used to call the lift to the rider should it be on another level. There are 2 types of Remote Call Stations. Push Button Used as a One Way call station. Bring the lift to the riders landing. Toggle Used as a Two way station Call to station or Send to station. Allows an attendant to place a rider on the lift and send them to the next level without getting on the lift with the rider.

Extension Purpose: The Extension is a panel that moves the edge of the control wall, out to the edges of the platform and allows for the mounting of gates and end walls on the lift. Extension brings the edge of the to the edges of the platform Standard Width Extension brings the edge of the to the edges of the platform Standard not as wide as Platform Standard Basic Lift Configuration The Extension also acts as a Guard Panel on the tower side of the lift. Not all lifts require a Extension. Unless specified as a code requirement, the basic Trus <T> Lift model ships with a Standard. Note: The Extension is required when mounting these options. Platform Gate Guard Panel (Solid Handrail)

Folding Access Ramp (Toe Plate) Purpose: The Folding Access Ramp serves a dual purpose. 1) It acts as a ramp to help the rider get to the top of the lift platform from the ground level. This can be anywhere from 1 ¾ to 2 ¾ depending on the configuration of the lift. The platform on a lift that has no safety pan installed, is 1 ¾ from ground level. A platform that has a safety pan installed is 2 ¾ higher than ground level. 2) It acts as a roll back stop folding up behind the wheels of a Scooter or Wheelchair to prevent rolling off the lift. Available in 2 sizes. 8 & 18. The 8 ramp is suitable for basic lifts that do not have a solid platform and safety pan. The 18 ramp should be used on lifts that have solid platforms and safety pans. (Due to the height difference mentioned earlier) Folding Access Ramp Folding Access RAMP Upper Landing Gate or Door Purpose: Prevent access to the edge of the landing if the lift is not in position to receive or discharge a rider. Gate Location Example The Upper Landing Gate is mounted on the upper landing where the rider enters or exits the lift. It remains locked through the use of an interlock. Once the lift arrives at the destination, the interlock automatically unlocks the Door or Gate. Upper Landing Gate Door Location Example Depending on the code in your area you may able to use a combination of Doors and Gates on your Enclosed Lift applications Enclosed Lift Door and Gate Example

Guard Panel (Solid Handrail) Purpose: Encloses the rider for safety. Extension The Guard Panel (Solid Handrail) encloses the rider on one side so that they cannot reach out beyond the confines of the lift. Typically used in applications that require meeting safety codes. The Guard Panel is installed opposite the Control Tower in a Straight Through configuration. It is installed in front of the rider in an Adjacent configuration. Note that the Guard Panel is an option. The basic lift includes a tubular style rail as standard equipment. The basic configuration should only be used for limited height applications and where code allows. Straight Through Configuration Guard Panel Control Wall Extension Tubular Style Rail Basic Model Guard Panel Adjacent Configuration Note: Typically installed with the following options. Extension Platform Gate Solid Platform

Platform Gate (Carriage Gate) Purpose: Safely enclose the rider with a lockable gate. The Platform Gate is meant to act as a safety barrier and is required in many applications. Upward travel: The Platform Gate will travel with the rider. It is situated behind the rider. The gate remains closed and locked on the upward travel. The rider exits the lift on the upper landing usually through a permanently mounted gate on the upper landing. The Upper Landing Gate is also interlocked. It will not unlock until the lift safely arrives at the upper landing. Downward Travel: On the downward travel the Platform Gate will travel with the rider (in front of), once the lift arrives at its destination the Platform gate is automatically unlocked. Allowing the rider to safely depart the lift. Platform Gate The Platform Gate is locked through the use of an Electrical Latching System known as an Interlock. (see Interlock for details) Please note that the Interlock is not an auto door opener. It is a lock only. Note: In order to install a Platform Gate on a lift the following items must also be installed. Guard Panel (Solid Handrail) Extension

Solid End Wall Purpose: The solid end wall acts as point of containment and prevents the rider from progressing in a forward motion once on the platform. The rider is forced to exit the same direction they entered the lift. Same Side Entry/Exit. Typically installed in a shaft or hoistway. It can also be configured to be used in a non-enclosed configuration. Solid End Wall Extension Solid End Wall Extension Guard Panel Platform Gate Same Side Entry/Exit Configuration. Shaft Installation Example Guard Panel Same Side Entry/Exit Configuration. Non-Enclosed Installation Example Note: Non-enclosed Same Side Entry/Exit must be installed with the following options. Platform Gate Extra Wide Upper Landing Gate

Solid Platform c/w Safety Pan Purpose: A Solid Platform (carriage floor) and Safety Pan (under platform safety device) are required when meeting certain code requirements or when the client desires a level of safety beyond the standard equipment installed on the lift. Our basic Cross section view of Solid Platform & Safety Pan models ship with an expanded metal (grate style) platform. Limit Switch and Spring The Safety Pan is attached to the underside of the Solid Platform. It uses a 5 point spring loaded pressure system that stops the lift automatically should it meet an obstruction. A Safety Pan is always used in conjunction with a Solid Platform. Note: The Safety Pan will not function with a basic expanded metal platform. Adjacent Platform (Side Access) Purpose: An Adjacent Platform is used when a Straight Through Platform configuration will not work. It allows the rider to exit at a 90 degree angle on arrival at the upper landing destination. The width of the platform is generally greater to provide extra space for the rider to maneuver their Scooter or Wheelchair into position for the downward travel. Adjacent Platform Example

Tower of Power (DC Backup) Purpose: Provide emergency power to keep lift operational during power outage. The Tower of Power is the next generation of DC backup systems. Unlike conventional DC backup systems that allow the batteries to go stale through lack of use. The Tower of Power uses the battery system every time the lift is operated and then immediately recharges the batteries. If a battery fails, the Smart Switch System indicates the problem with a signal light and will default to building power until the battery is replaced. This ensures that your lift is operational when you need it.

Additional Options Maintenance Plans Your lift should be serviced regularly. A minimum of once per year and in harsher climates more frequently. Servicing your lift extends the life of the lift. A small investment in service now, saves you greater cost on replacement later. Not servicing the lift could affect the warranty. Custom Colors The standard color of the Tru <T> Lift is Slate Grey and Black. Custom colors are available at a modest upcharge. Inquire with our sales department as to the available choices.