Z O N E C O N T R O L

Similar documents
AIR CONDITIONER WALL CONTROLLER

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

REMOTE CONTROL MANUAL

Operating Instructions Air Conditioner

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

Owner s Manual. Using the Ducted Gas Central Heating Add-on Refrigerated Air Conditioning Ducted Evaporative Air Conditioning.

Owner s Manual RBC-AMS41E. Remote controller with weekly timer. Owner s Manual

Owner s Manual. Using the Ducted Gas Central Heating Add-on Refrigerated Air Conditioning Ducted Evaporative Air Conditioning.

Home Screen...4. Quick Start Guide...5. MyAir Standalone Zone Controls only...5. MyAir Zone Controls With Integrated Unit On/Off Control...

ACONT900AC43UA Communicating, Programmable Comfort Control

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)

DUCTED AIR CONDITIONING SOLUTIONS

Single Zone LCD Thermostat Operating Instructions

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

Homeowner Quick Start Guide. Version 2

INSTALLER S & OWNER S MANUAL

Table of Contents. 1 - Specifications Installation Wiring User controls...7

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

HEAT PUMP PROGRAMMABLE THERMOSTAT

Blue Easy Reader Thermostat 1F95EZ Homeowner s Guide

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Installation Instructions

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

How to choose a heat pump and use it wisely

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Chapter 2 System Basics

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

DUCT TYPE AIR CONDITIONER

USER S MANUAL HSC-24A

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

Using Time-of-Day Scheduling To Save Energy

Installation Instructions

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Portable Air Conditioner

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.

Instruction manual for Firstline FCS12000CH

Article: Version:

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

CM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

CM927 - User Guide. Description. Features. 7 day Wireless Programmable Room Thermostat with LoT Technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

Energy Saving Tips. Adjust set point temperature up a few degrees... Window contact. Occupancy sensor. A Programmable Thermostat

HEAT HEAT COOL HEAT PUMP COOL

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

User Manual THR840DUK Digital Thermostat

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Introduction. Motor Types

ABNORMAL OPERATION Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target

HVAC Processes. Lecture 7

A/C-HEATER SYSTEM - AUTOMATIC

Communicating Wall Control Installation Manual TSTAT0101SC

Variable Air Volume - VAV

Workshop 7 PC Software - Tracker

Reverse Cycle Inverter Split System Air Conditioner

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

ADEMCO 4500 Thermostat

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February FA-300 SERIES Fire Alarm Control Panel

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Operation Guide 3M-22

OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex

APPLICATIONS SPECIFICATIONS CAUTION. Blue Universal Thermostat with Automatic Heat/Cool Changeover Option. Save these instructions for future use!

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

USER S INFORMATION MANUAL

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

OPERATING & MAINTENANCE MANUAL. Packaged Terminal Air Conditioner (PTAC) World Class Comfort.

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Owner s Manual. Walk-in Monitoring System 100. Cooler is Better! TM. Used in UL Listed Door Panel Assemblies

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

FULL DC INVERTER SYSTEMS

and using this appliance and keep this manual for future reference.

Commercial Refrigeration Temperature and Defrost Controls

HEAT RECOVERY VENTILATORS MODELS 90H-V ECM HRV, 90H-V+, 60H-V+ AND ENERGY RECOVERY VENTILATOR MODEL 90H-V ECM ERV

Installer Guide smart connect

ECO-AIR AIR CONDITIONING

Failure code manual. content

Mode Switch. Fan Switch Menu button Program button

Aurora UPC ZS Zone Sensors User Guide

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

Energy Efficiency. Energy Efficient Home Cooling:

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

1F /1/1 Day Programmable. 1F Thermostat Thermostat Configuration Options Heat Pump. Maximum Stages Heat/Cool 2/1

AQUAREA USER GUIDE FOR BI-BLOC, MONOBLOC & ALL IN ONE

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

LP Series Lighting Control Panel Programming Instructions

CATALYST Frequently Asked Questions

Transcription:

OPERATING INSTRUCTIONS ULTIMA ZONE CONTROL ULTIMA ZONE SENSOR CONGRATULATIONS: on your purchase of an ActronAir air conditioning system.this unit has been meticulously designed and engineered to achieve maximum energy efficiency. It is manufactured from the highest quality materials which has passed numerous "in house" and "external" inspection procedures, ensuring years of satisfactory operation. This user friendly Operating Instruction Manual is supplied to provide you with an understanding of the system. It includes step-by-step instructions on how to operate and maintain your system. Please read this booklet thoroughly. ACTRON ENGINEERING PTY LTD C COPY RIGHT

General Information YOUR ACTRONAIR ESP ULTIMA SYSTEM IS A STATE OF THE ART PRODUCT with advanced Microprocessor Control that automatically controls and regulates conditioned air in each zone to provide year-round climate control and comfort. INSIDE THIS MANUAL You will find instructions for Zone Controller used with ActronAir ESP Ultima system. Functions of Master Controller, AM4-8Z and AM7-D8 in connection with ESP Ultima operation, are also explained. NOTE: Basic and detailed functions of Master Controller, AM4-8Z and AM7-D8, are explained in operation manual (0500-005) supplied with your A/C units. ACTRONAIR ESP ULTIMA SYSTEM is a highly advanced and efficient VAV system that lets you control the temperature of each zone. It is also used in conjunction with ECM (Electronically Commutated Motor) indoor fan and ActronAir ESP digital compressor technology for maximum energy savings and comfort. IMPORTANT To ensure efficient and proper operation of your equipment, read and understand all instructions. Failure to do so may result in damage of equipment and warranty maybe void. Contents General information... Page Zone controller functions... Page Turning zone control ON... Page ESP Auto mode... Page 4 Zone damper blade indicator... Page 5 Fan Only Mode... Page 6 Zone temperature display... Page 8 Zone open mode... Page 0 Troubleshooting... Page Frequently Asked Questions... Page Copyright c 007 All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the written permission of Actron Engineering Pty. Ltd.

Zone Controller Functions 7 6 5 8 9 0 ZONE COOL HEAT ESP AUTO OFF C Z O N E C O N T R O L ROOM ON/OFF 4 ON/OFF button Turn the zone ON or OFF. Room temperature button View actual room temperature. Damper position indicator Indicates the position of zones air damper. (shown fully open) 4 COOL indicator Illuminates when zone is receiving cooling. 5 HEAT indicator Illuminates when the zone is receiving heating. 6 Temperature Set Point display 7 ZONE indicator 8 ESP AUTO indicator Illuminates when the zone control is modulating the airflow. 9 OFF indicator Illuminates when zone is off and damper is fully closed. 0 Set Temperature button Raises the set point for warmer temperature. Temperature setting button Lowers the set point for cooler temperature.

TURNING ZONE CONTROL ON AM PM.0 EVENT TIME CLOCK MON TUE WED THU FRI SAT SUN ON OFF ROOM CONT HIGH MID LOW COOL AUTO HEAT RUN TIMER FILTER ON OFF FAN CONTROL TIMECLOCK PROGRAM COUNTDOWN TIMER EXIT REPEAT AUTO HEAT / COOL ZONE COOL ESP AUTO C Z O N E C O N T R O L 4 LOUNGE DINING RUMPUS STUDY 5 6 7 8 MAIN BED BED BED BED 4 ROOM ON/OFF MASTER CONTROLLER ZONE CONTROL Turn the system ON by pressing the button on Master Controller (AM7-D8 or AM4-8Z). To turn the zone ON, press the button on the Zone Control or alternatively; Press the designated zone on Master Controller. ON / OFF Zone Control display will show the ERATURE, ZONE and ESP AUTO. Set the desired temperature by pressing either UP or DOWN arrow keys on the Zone Controller. * For warmer room temperature, press the UP arrow key. For cooler room temperature, press the DOWN arrow key. ON OFF NOTES * Zone Control temperature setting can only be adjusted C below or above the Master Controller set point temperature. This is a factory set limit. Recommended to maintain system accuracy and maximize efficiency. Should this require changing contact ActronAir Technical support on free call 800 9 9. Master controller shown above is AM7-D8, same procedure will be followed for AM4-8Z model. o

ESP Auto Mode C ZONE COOL HEAT ESP AUTO Z O N E C O N T R O L Indications of Cool or Heat will show zone conditioning. (When zone damper is providing warm or cold air to your zone.) ROOM ON/OFF / Press the button on until ESP AUTO appears on the display. ON / OFF Set the desired temperature by pressing either UP or DOWN arrow keys. For a warmer room temperature, press the UP arrow key. For a cooler room temperature, press the DOWN arrow key. Press the button to turn off the zone. Or alternatively, press the designated zone button on the Master Controller. ON / OFF Turning Off When the designated zone LED in the master control turns OFF, the zone is OFF. Notes In Zone Control ESP AUTO mode, the controller will adjust the position of zone damper automatically in order to meet the desired set temperature. Heating mode will be displayed when the zone starts to heat the room. Cooling mode will be displayed when the zone starts to cool the room. 4

Zone Damper Blade Indicator Display Status FULLY OPEN DAMPER BLADE Allows full airflow through to meet your required conditions. PARTIALLY CLOSED DAMPER BLADE Regulating air and temperature to meet set conditions. PARTIALLY OPEN DAMPER BLADE Regulating air and temperature to meet set conditions. NO DAMPER BLADE INDICATOR Room is satisfied with temp. Zone is turned off Zone is waiting on Heat/Cool mode change. When in ESP Auto, damper blade indicator will automatically adjust itself to regulate the correct amount of airflow (heat or cool) to maintain the desired setpoint temperature. 5

FAN ONLY CIRCULATION AM PM.0 EVENT TIME CLOCK ON OFF MON TUE WED THU FRI SAT SUN ON OFF ROOM CONT HIGH MID LOW COOL AUTO HEAT RUN TIMER FILTER FAN CONTROL / AUTO HEAT / COOL TIMECLOCK PROGRAM COUNTDOWN TIMER EXIT REPEAT 4 LOUNGE DINING RUMPUS STUDY 5 6 7 8 MAIN BED BED BED BED 4 5 4 5 Ensure your air conditioner is turned off. Press the FAN CONTROL button. Fan LED will illuminate on screen. Press FAN CONTROL again to select HIGH, MID or LOW fan speed. All zones will open to circulate air throughout your home. If you wish to shut the zone in any particular rooms in this mode, simply turn off zone by pressing the zone buttons. Zone LED will go off. NOTES This mode is commonly used to circulate airflow without Cooling or Heating throughout the home. Quite often used on mild days to circulate fresh air through the home. Simply open a few windows and let the FAN ONLY circulate fresh air through the home. 6

Fan Only Mode ZONE Z O N E C O N T R O L ROOM ON/OFF FAN will be displayed on zone control display when the master wall control is set to circulation operation. During this period, zone dmper will be in fully open position for maximum air circulation. Press /ON/OFF button to turn OFF the zone damper. If you do not want the unit to circulate airflow in your room in this mode, simply push the ON/OFF button in your zone controller or turn your zone OFF at the master control. 7

Zone Temperature Display TO CHECK ERATURE AT MASTER CONTROLLER AM PM EVENT TIME CLOCK ON OFF MON TUE WED THU FRI SAT SUN ON OFF ROOM CONT HIGH MID LOW COOL AUTO HEAT RUN TIMER FILTER FAN CONTROL AUTO HEAT / COOL TIMECLOCK COUNTDOWN PROGRAM TIMER EXIT REPEAT 4 LOUNGE DINING RUMPUS STUDY 5 6 7 8 MAIN BED BED BED BED 4 Average Room Temperature Display Press button in the TIMER section and the average room temperature will be displayed for seconds. "ROOM" LED flashing means the temperature displayed is the average of all activated zone sensors. Checking Individual Zone Temperatures Press button in the TIMER section While "ROOM" LED is flashing, press the zone to be checked. The "ROOM" LED turns off and the selected zone LED flashes. During this time, the selected zone temperature is displayed. To check another zone, simply press the zone button while "ROOM" or zone LED is flashing. Notes Room temperature displayed can be the temperature at a zone control or at a remote sensor or the average of both depending on installation. 8

Zone Temperature Display TO CHECK ZONE ERATURE AT ZONE CONTROLLER C ZONE COOL HEAT Z O N E C O N T R O L ROOM ON/OFF ROOM Press the button. Actual room/zone temperature will be displayed for several seconds then returns to set point temperature. During this period, the blue LED will flash when display is showing the room temperature. Notes To display the room temperature for 45 minutes, press and hold ROOM button for 5 seconds. The room temperature display can be the temperature at the zone controller or the average of both zone control and remote sensor depending on installation. 9

Zone Open Mode ZONE Z O N E C O N T R O L ROOM ON/OFF / Press the button twice in quick succession until OPn appears in the display screen. ON / OFF OPn will appear on the display. Zone damper blade will be in maximum open position. Turning Off Press the button to turn off the zone. ON / OFF Or alternatively, press the designated zone button in the master wall control. Notes It is not possible to control or adjust the temperature in this mode. This zones temperature now will depend on the systems operating mode (Heat or Cool). This mode has no control on room temperature, your sensor is ignored in this mode. A zone in OPn mode is like having a non temperature controlled ON/OFF zone damper. Zone cannot be put in OPn mode. 0

Troubleshooting Conditions The system does not start. Remedy Check that 5 minutes has passed from the time you turned the system on as there are in-built safety timers. Check thermostat settings are correct. Check thermostat set point is low enough for cooling or high enough for heating. Check the Master Controller is set to the correct mode for COOL/AUTO/HEAT. Air does not flow. Check if the unit is set in the correct mode COOL/AUTO/HEAT. Check your zone control is turned on. If using sensor ensure your zone is on at the master. During defrost cycle of the outdoor unit in heating mode, the indoor fan will not operate. Defrost cycle is indicated when the heat LED on the master control is flashing. OFF is displayed on my zone control and I can not turn it on. This means the Master Controller is turned off. First turn on your air conditioner at the master control. You will now be able to turn on your zone control. For any assistance with your ESP Ultima System do not hesitate to contact our Customer Care Team. Freecall Technical Support 800 9 9.

Frequently Asked Questions Q. I can not adjust my set point on my zone controller any more than degrees higher or lower than the master controller. A. degrees is the the default setting for master temperature offset. ActronAir recommend this degree offset to optimise temperature control and maximize energy efficiency. Moving this settings outside +/- degrees will result in temperature inaccuracy. Contact ActronAir technical support on Tel. No. 800 9 9. Q. Cooling and Heating seems to take a long time to achieve temperature in ESP fan mode. Am I using the correct settings? A. ESP fan mode really comes into it's own when minimal zones are used. For quicker and more responsive Cooling and Heating when using more than minimal zones, select High or Cont High fan speed on the master control. This will boost heating and cooling and is best optimized when you want to condition more than the minimal zone set up. Q. Cooling and Heating is not sufficient in my zone. A. Air balancing is essential part of system commissioning in Ultima system. The duct design may be prohibiting the correct amount of airflow reaching your area. Please contact your installer to ensure air balancing has been carried out. Q. There is substantial air noise coming from my outlet. A. If the outlet gets too noisy when the unit or zone is first turned on, the system maybe over supplying airflow to your area. Ensure ESP fan mode is used when using minimal zones.please contact your installer to ensure air balancing has been carried out. Q. There are dashes across my control display. A. Make sure you have not had a power cut out. If this is still present on the display after 0 seconds, please contact your installer. Incorrect wiring or a broken circuit could also cause these symptoms. Fault Codes. E? When is displayed in the master controller or zone control, take note of the the digits after E and contact your installer. E E5 - System has detected less than sensors (Ultima requires at least sensors in circuit) or, a Remote Sensor is short circuit. - No Communication. The system is constantly relaying information back and forth. This indicates that communication is not happening. Contact your installer to check your wiring and cable's integrity.