HARGROVE GAS LOGS ELECTRONIC IGNITION GAS VALVE SYSTEM Model # - DEI-PO INSTALLATION INSTRUCTIONS

Similar documents
NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM FOR NATURAL OR PROPANE GAS EPK-1 PILOT KITS

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

GAS SAFETY PRECAUTIONS

24.2L M.A.N. V12 Engine Module

Advantium 2 Plus Alarm

G670 Intermittent Pilot Ignition Controls

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

SL280UHV SERIES GAS FURNACE WARNING

For Models #6-5001, #6-7501, # & #10-12K1

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

INSTALLATION AND OPERATING INSTRUCTIONS

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: Natural Gas

GM DURAMAX LMM Fuel Pickup Kit Installation Guide

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

BroadBand PowerShield. User Manual

Installation and Operating Instructions (for chargers shown below)

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

Installation Instructions for Alarm Module Kit A043F059

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Cambridge Electric Infared Fireplace User Manual

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Your safety and the safety of others are very important.

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

Installation Manual DIAPHRAGM WELL TANK

VK-250 WARRANTY REGISTRATION FORM

Owner s Manual & Safety Instructions


Operator: Save these instructions for future use!

Installation Operation & Maintenance Manual

Electric Water Heater

TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION

!"" #$% "!&' ( ( ) *

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Air Conditioning Systems Warranty Manual. Version 1.8

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

Applies to: Models F, B, FE, and BE FOR YOUR SAFETY

HEAT WAVE DUCT KIT KIT #

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

Installation and Operation Guide for PD5100 Automatic Transfer Switch

CARING FOR YOUR WATER HEATER

Service Bulletin SA-008. DATE: June 18, 2008 TO: All Service and Parts Managers SUBJECT: Flood Damaged Appliances

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free


Ducoterra Radiant Heating Panel Installation Manual

BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

3 WATT LED SPOTLIGHT Model No. SLM

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Troubleshoot resources for homeowner

OUTDOOR GAS FIREPLACE USER GUIDE North America _2 EF

OAK WORKBENCH WITH 2 DRAWERS

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Wireless Indoor/ Outdoor Thermometer

User and Installation Guide

Assembly Instructions & User s Manual Triton Classic Gas & Charcoal Grill Model #: FSOGBG3005

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

Hydraulic Punch Driver Kit

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

DCX300 - DCX400 - DCX600

12-Volt Negative Ground Installation Instructions

Installation and Operating Instructions (for chargers shown below)

Global Water Instrumentation, Inc.

Operating Guide Manuel de l utilisateur

POWER GEAR SLIDE OUT MANUAL

Powerware Relay-Serial Card User s Guide

Single Station Remote Alarm

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

12 Volt 30 Amp Digital Solar Charge Controller

GeniSys 12V. Model Description / Applications. Advanced 12 Vdc Burner Control

Installation Manual DIAPHRAGM WELL TANK

Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual


TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

Manual for Fire Suppression & Methane Detection System

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

INSTALLATION INSTRUCTIONS

Electric Mini Tank Water Heaters WM-2.5 & WM-4.0

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Challenge Friends, Get Ranked and Earn Points with the FUTCHI_App Players


About this Manual. Support for Your Product

Transcription:

HARGROVE GAS LOGS ELECTRONIC IGNITION GAS VALVE SYSTEM Model # - DEI-PO INSTALLATION INSTRUCTIONS This gas pilot safety valve provides 100% shut-off of both pilot and main burner gas supply in the event of pilot flame failure. The 3V system utilizes a regulated gas valve with Electronic Ignition attached with either AC or DC power and Switching Device to control it as an automatic flame-producing device with or without external electricity. If the pilot flame goes out during normal operation, or if the pilot flame does not cover the sensor rod, the safety valve will close stopping the flow of all gas. This valve is designed for use on domestic heating gases up to ½ PSI. FOR YOUR SAFETY IF YOU SMELL GAS: 1. OPEN WINDOWS 2. DON T TOUCH ELECTRICAL SWITCHES 3. EXTINGUISH ALL OPEN FLAMES 4. IMMEDIATELY CALL YOUR GAS SUPPLIER CAUTIONS 1. This valve should be installed only by an experienced service technician trained in gas safety equipment. 2. Turn off gas supply before installing valve. 3. All piping must meet applicable local codes and ordinances and the National Fuel Gas Code (ANSI Z223.1/NFPA. 54). 4. All wiring must meet applicable electrical codes and ordinances. 5. Check out the complete system after installing the valve. 6. Prior to installation, verify conformance with burner manufacturer s installation instructions. 7. Make sure all piping is free of foreign matter. FLAMMABLE VAPORS MAY BE DRAWN BY AIR CURRENTS FROM OTHER AREAS OF YOUR HOUSE TO THIS APPLIANCE. FOR YOUR SAFETY DO T STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.

INSTALLATION INSTRUCTIONS! WARNING! Fire hazard. Do not disassemble or attempt to repair this unit. Disassembly, reassembly or internal adjustment could cause valve to malfunction, resulting in personal injury, death or property damage. If the control valve does not operate properly following installation or service, replace this unit. WARNING: Valve may not shut off if gas flow is not in direction of arrow on valve body. WARNING: Warranty is void if the DXMV-C is installed behind the burner pan in the fireplace. This valve system can be installed outside of the fireplace. DO T INSTALL DXMV-C VALVE BEHIND THE EMBER BURNER PAN IN THE FIREPLACE. DXMV-C VALVE MAY OVERHEAT, FOR BEST RESULTS MOUNT PARELLEL WITH FIREBOX. Fig 1 Fig. 1 Parts List Description 1. DXMV-C Electronic Ignition Safety Valve 2. DXICM I/C Module 3. DXBP Battery Pack 4. DXWH Wire Harness 5. DXPI-48 Pilot Assembly 48 leads 6. DEI-PB Pilot Assembly mounting bracket EMBER BURNER PAN 7. HSRS225 Safety Valve Heat Shield 8. SW-HSRS-225 (not pictured) Superwool Insulation for HSRS225 Heat Shield 9. DEI-CHS Heat Shield for I/C Module & Battery Pack 10. SW-DEI-CHS (not pictured) Superwool Insulation for DEI-CHS Heat Shield 11. 49-6 Qty. 2-3/8 MIP X 3/8 FL Brass Elbow 12. RS On/Off switch - attaches to I/C Module Heat Shield 13. #8 X ½ screws Qty. 4 - Screws used for pilot assembly and pilot bracket 14. FCNW-18 Non-whistling flex connector 18 long 15. C-Size Batteries (not pictured) Qty. 2 Go inside of DXBP DXMV-C 12 1 4 9 7 3 14 5 6 11 13 2

INSTALLATION INSTRUCTIONS BURNER ASSEMBLY (Figure 2 & 3) Fig. 2 1. Attach the small side of the Pilot Bracket (DEI-PB) to the pre-drilled holes on the back wall of the Ember Burner Pan using two of the #8 X ½ screws. IMPORTANT: The Pilot assembly should be mounted on the outside of the pan. 2. Next, attach the Pilot Assembly (DXPI-48) to the Pilot Bracket. (See Figure 2) 3. Attach the 49-6-6Z2 (included in the Standard Burner Accessory kit box) brass fitting to the burner pipe extending out of the right side of the burner pan (same end that the pilot is mounted on). 4. Attach the 49-6 into the OUTLET end of the DXMV-C valve. 5. Attach the FCNW-18 to the 49-6-6Z2 on the end of the pan. Back Wall of Ember Burner Pan Pilot Assembly 6. Attach the 49-6 to the INLET (marked IN on the valve body) end of the DXMV-C valve. 7. Connect the pilot tubing from the DXPI-48 to the elbow fitting on the top of the DXMV-C valve. 8. Connect the Gas Supply to the 49-6 (on the valve) and to the gas inlet pipe that comes into the fireplace (connector is included in the Standard Burner Accessory kit box, not this kit). TOP VIEW OF BURNER ASSEMBLY Fig. 3 TOP VIEW OF PILOT ASSEMBLY Screws DXMV-C 49-6-6Z2(from burner accessory kit) EMBER BURNER PAN 49-6 Gas Inlet -Connect to Gas Supply 49-6 FCNW-18 DEI-PB DXPI-48

INSTALLATION INSTRUCTIONS CONTROL MODULE ASSEMBLY (Figure 4 & 5) 1. Attach the large white plug on the DXWH (wire harness) to the DXICM (I/C Module).(Fig. 5) 2. Attach the wire from the Pilot Assembly labeled I (ignitor) to the terminal labeled I on the DXICM. 3. Attach the wire from the Pilot Assembly labeled S (heat sensor) to the terminal labeled S on the DXICM. 4. From the DXWH (wire harness) attach the: a. Orange wire labeled THTP to the terminal on the valve labeled THTP. b. Green wire labeled TH to the terminal on the valve labeled TH. c. Black wire labeled TP to the terminal on the valve labeled TP. d. Red wire labeled + to the Red wire on the DXBP (battery pack). e. Black wire labeled - to the Black wire on the DXBP (battery pack). f. Brown wires (2) labeled SWI to switching device (remote control, wall switch, etc.) you will be using. WIRING TO VALVE WIRING TO CONTROL MODULE Fig. 4 Fig. 5 TO PILOT ORANGE THTP BLACK TP GREEN TH DXWH WIRE HARNESS TO A/C ADAPTER CONTROL MODULE AND BATTERY PACK PLACEMENT The Control Module and Battery Pack are sensitive to heat. Proper placement will help keep them from malfunctioning due to excess heat. FIREPLACE FLOOR 1. See the Parts List pictures to see how to properly place the Control Module and Battery Pack under the Heat Shield. 2. The best location for the Control Module Assembly is outside of the fireplace 1. On the hearth or 2. In a cavity that is accessible next CONTROL to the fireplace. MODULE 3. It is possible for the Control Module Assembly to be located inside ASSEMBLY the fireplace if it is in the far right or left corner close to the front opening of the fireplace. If nuisance operation problems arise the Control Module Assembly may have to be moved onto the hearth. FRONT OPENING OF FIREPLACE

LIGHTING THE BURNER SYSTEM LIGHTING INSTRUCTIONS 1. Make sure all gas connection fittings and wire connections are secure and safe for ignition. 2. Set the Switching Device (Switch on Control Module Heat Shield, Remote Control, or Wall Switch) to call for heat (ON position). 3. Watch and listen for a spark at the Pilot Assembly. 4. Pilot should light within a few seconds (if the pilot does not light within 10 seconds you may have to bleed the gas line to get the air out of the gas inlet pipe). 5. Once the pilot lights, the heat sensor (straight rod next to the pilot hood) will heat up and then activate the gas to the main burner. 6. When gas begins to flow to the main burner the pilot will light the burner gas and remain in operation during the operation cycle. 7. When the switching device is turned to the OFF position the main burner flame and pilot flame will shut down. 8. Follow Steps 2 through 6 to re-ignite the pilot and burner system. DEI-PO TROUBLE SHOOTING 1. Main flame will shut off the cycle back on again. A) This could be caused by poorly grounded system. If the system has a A bad ground it can cause the valve to turn off the cycle back on again. Check the Valve and Pilot to insure that they are secure. Also check black wire to valve for tight connection. B) This can be caused by not enough heat to the Sensor Rod causing the System to turn off the cycle back on again. Check sensor rod to insure it is in the pilot flame and is glowing. 2. Pilot and or Main flame won t light but there is spark at pilot hood A) This could be caused by the Orange and or Green wires spades have a poor connection at terminal block. Remove the wires from valve and tighten the female spades on the wire assembly. B) This could be caused by a bad solenoid. To check solenoid remove the Wires from the solenoid and check the Ohms with a multi-meter. The readings should be for Pilot = 0.037ohms. 3. Can hear spark, but no spark is visible at pilot hood. A) This could be caused by bad connection of ignition wire at module. B) This could be caused by improper spark gap between igniter rod and pilot hood it should be no greater than 0.25 gap. C) This could be caused by cracked ceramic on ignition rod. This would arc at the crack to the nearest ground. 4. Turn system on and there is no spark. A) This could be caused by no line power from adapter. Check the adapters Output with a multi-meter set on A/C it should read 3.0+ volts if not check j-box for output. If output at j-box replace the adapter. B) This could be caused by no D/C power from batteries. Check the Connections from battery pack to the module. Check output to RED & BLACK wires at spade connections from battery pack with multi-meter on D/C setting it should be 3.0+ volts. If power present at connections remove the harness plug from module check RED & BLACK females on harness plug for voltage output. If you have voltage at the spade connection and none at the plug replace wire harness.

DEI-PO TROUBLE SHOOTING CHART START ENGAGE SWITCH TO CALL FOR HEAT DOES THE PILOT START TO SPARK CHECK LINE VOLTAGE, CHECK FOR 3V TRANSFORMER OUTPUT, ADAPTER CONNECTION WIRING, ETC. REPLACE MODULE AFTER PREPURGE IS THERE SPARK AT THE PILOT IS THERE ANY CHECK IGNITION WIRING AUDIBLE SPARK AND PILOT ASSEMBLY REPLACE MODULE PILOT BURNER CHECK VALVE, LIGHTS WIRING, ETC. SPARK STOPS WHEN PILOT LIGHTS MAIN BURNER LIGHTS CHECK FLAME SENSE AND TP TERMINAL CHECK IF FLAME COVERS ROD, CLEAN SENSOR ROD CHECK VALVE, WIRING CHECK CONTINUITY OF SENSOR AND TP TERMINAL SYSTEM RUNS UNTIL POOR GROUNDING MAY CALL OFF HEAT CAUSE OCCAISONAL SHUTDOWNS. CHECK FOR EXCESSIVE HEAT AT ROD CALL FOR HEAT OVER SYSTEM SHUTS OFF END TROUBLE SHOOTING CHECK SWITCHING DEVICE AND VALVE

LIMITED WARRANTY Refractory Logs Hargrove gas logs carry a limited lifetime warranty against any manufactured defect or breakage when installed indoors. A replacement will be available from the dealer at which the appliance was purchased. This warranty does not cover breakage caused by excessive handling once installed and fired. Outdoor applications carry a one (1) year limited warranty. Burner & Grate If the burner or grate fails due to deterioration within five (5) years of the verified purchase date, a free replacement will be made available from the dealer at which the appliance was purchased. Valves, Remote Controls, & Switching Devices Hargrove warrants all valves, remote controls and switching devices against manufacturing defects, which appear within two (2) years of the verified purchase date. Warranty does not cover products that have been damaged by misuse from overheating. Before any product is returned a Return Goods Authorization number (RGA) must be issued by Hargrove s Customer Service Department. All returns must be accompanied by an explanation of the problem and all necessary parts. All Other Parts If any assembled part should fail to operate or be found defective which appear within two (2) years of the verified purchase date, a replacement will be available from the dealer at which the appliance was purchased. Buyer shall notify Hargrove Mfg Corp. of any defect covered by this warranty no later than thirty (30) days after defect is discovered. Failure to provide notice within thirty (30) days shall void the limited warranty. WHAT IS T COVERED 1. Removal and reinstallation costs. 2. Labor costs for replacement or repairs. 3. Transportation or shipping cost. 4. The cost of a service call to diagnose trouble. 5. Painted Surfaces. 6. Damage or defect caused by improper installation, accident, misuse, abuse, alteration, or authorized service technician. 7. Replacement of burner or combustion chamber resulting from improper storage of the appliance. LIMITATIONS AND EXCLUSIONS 1. No one has authority to add to or vary this limited warranty, or to create for Hargrove Manufacturing Corporation any other obligation or liability in connection with this appliance. 2. Any implied warranty applicable to this appliance is limited in duration to the same period of time as this written Warranty. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you. 3. HARGROVE MANUFACTURING CORPORATION WILL T BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, SPECIAL OR CONTINGENT DAMAGES YOU MIGHT SUFFER AS A RESULT OF A CLAIM UNDER THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusion may not apply to you. 4. This warranty applies only to the original purchaser and may not be transferred or assigned. 5. If you cannot verify the purchase date of the appliance, the warranty period will begin on the date of which the appliance was manufactured. 6. Replacement or repair parts are warranted for the remaining period of the original part warranty. Warranty parts must be obtained through authorized dealers of this product who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. 7. The maximum liability of Hargrove Mfg Corp. in connection with this limited warranty shall not in any case exceed the contract price paid for the product claimed to be defective or unsuitable. 8. Purchaser or user agrees to hold Hargrove Mfg Corp. harmless from any and all claims by the buyer as a result of injury or damage to an ultimate user or other person caused by the product sold herein by the seller to the buyer, whether the injury or damage results from the assembly, installation, operation, shipment, storage, or manufacture of this product. Hargrove Mfg Corp. makes no warranties, expressed or implied, other than those expressly stated herein. YOUR DUTIES This appliance must be installed by a qualified installer, operated and maintained in accordance with all applicable codes and the instructions furnished with the appliance. You must provide a receipt verifying the purchase date of the appliance when making a warranty claim with the dealer from which the appliance was purchased. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. To register your Hargrove product, please visit our website at http://www.hargrovegaslogs.com/reg.htm. CONTACT INFO: Hargrove Manufacturing Corp. Tele: (800) 725-4166