1. CURRENT TRANSFORMERS Support type Support window type Generator / Wall-bushing type Touch-proof type Wall-bushing with primary bar type

Similar documents
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

LOW-VOLTAGE CURRENT TRANSFORMERS

Takfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Medium-voltage transformers

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Transformer Bushings for GIS

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

System 8. ü ( System 8

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Secondary Unit Substations

Tape Wound, Split Core and Ebony Current Transformers

Tape Wound, Split Core and Ebony Current Transformers

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation

FAQs-Main switchboard design criteria

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

How To Build A Low Voltage Capacitor Lvcp

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS

Directory chapter 04

2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Enhanced Quality with a Touch of Style

SECTION DRY-TYPE TRANSFORMERS

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

3/2-way Solenoid Valve, direct-acting, NC or NO

Series 8146/5-V37 and Series 8150/5-V37

Nordson Automatic Spray Gun Support Kits

SPECIFICATIONS FOR 220KV CAPACITOR VOLTAGE TRANSFORMER. The equipment is required for 220KV system. The system data is given as under:

MNS is Switchgear System Technical Overview

Current transformers (CT) & Shunts

Terminal Boxes Series 8146

Vario-Series Accessories

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

Metal Clad Indoor Instrument Transformer for Plug-In Systems

Z-TRAUQ INC. Tel.: (450) Fax: (450)

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Low Voltage Switchboards The Best Technical Solution for Your Ship

Technical Specification for Oil insulated Transformers U m < 24 kv up to 1250 kva

CAS 36 Ring Main Unit

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

DuroSite TM High Bay Lighting

4 Posiflow Proportional Solenoid Valves

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

This section applies to the design and installation of transformers.

Measurement devices Accessories for analogue and digital instruments

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

SURGE PROTECTIVE DEVICES

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

CDGRD-10. Grounding. Solutions For Comm/Data Applications

DS 600. A contact free flux gate based current measurement sensor 600A rms

Electronic overload relay EF19 and EF45

Mini USB and USB 2.0-IP67 Connector System

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Installation, Operation and Maintenance Instructions. Uniflex ABB PTMV

AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC

Lightning Arresters P KVA P KVA. Description & Installation

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Presentation of the France Transfo factories

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

a Nexans company Catalogue 2014

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

UFES Active protection for switchgear

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

Electronic overload relay EF65, EF96 and EF146

Securing your electrical installations Prisma,

Current Limiting Protector For Systems rated kV and continuous currents through 5000A.

The standards mentioned in this document

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

Measurement and Instrumentation

The Intelligent AX1 Switchgear for Medium Voltage

understanding medium frequency induction melting furnace and its components

Switchboard system. NorLine 800

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Transcription:

1. CURRENT TRANSFORMERS Support type Support window type Generator / Wall-bushing type Touch-proof type Wall-bushing with primary bar type 4

1. CURRENT TRANSFORMERS INTRODUCTION Current transformers reduce the current in the Medium Voltage line to proportional and manageable values, and separate the measuring instruments, meters, relays, etc. from the power circuit. Support type Support window type SECTION 1. Primary terminals 2. Insulation (resin). Primary winding 4. Core and secondary winding 5. Secondary terminal box 6. Base 7. Earth terminal Generator / Wall-bushing type 1 2 Touch-proof type 4 7 5 Wall-bushing with primary bar type ACF 6 5

ACM-12 Support type transformer for primary distribution swichgears. ABG-24 Current transformer for generator designed to work with very high primary currents. ABD-6 Wall- bushing type transformer with shortcircuitable secondaries. 6

1. CURRENT TRANSFORMERS > Support type SUPPORT TYPE Current transformers for indoor service, encapsulated in resin which in addition to their primary function also act as busbar supports. RANGE Insulation voltage from.6 kv to 72.5 kv. Rated primary currents from 1 A to 000 A. Secondary currents: 1 and 5 A. Frequencies: 50 Hz, 60 Hz. ACF APPLICATIONS Medium voltage air insulated primary distribution switchgears. Medium voltage air insulated secondary distribution switchgears. Capacitor Banks. ACD ADVANTAGES Possibility of secondary currents different from the standardized ones (1 and 5 A). Possibility of frequencies different from the standardized ones (50 and 60 Hz). Secondary terminals on the or side. Designed to withstand vibrations. Excellent response under extreme weather conditions. Short-circuit system for secondary terminals and dimensions as per with DIN 42600 available. Ratio change by primary or secondary tapping. Stainless steel screws, bolts and nuts available. It can be assembled in any position (vertical, horizontal, etc.). Designs approved by Underwriters Laboratories (UL-USA) available. ACH ACK ACJ 7

1. CURRENT TRANSFORMERS > Support type MARKING RATIO AND ONE SECONDARY > DOUBLE PRIMARY RATIO BY SECONDARY TAPPING AND ONE SECONDARY RATIO AND TWO > DOUBLE PRIMARY RATIO AND ONE SECONDARY C1 C2 S1 S2 S1 S2 S 1S1 1S2 2S1 2S2 S1 S2 RATIO AND THREE RATIO AND TWO WITH TAPS > DOUBLE PRIMARY RATIO AND TWO C1 C2 1S1 1S2 2S1 2S2 S1 S2 1S1 1S2 1S 2S1 2S2 2S 1S1 1S2 2S1 2S2 Electrical characteristics Highest voltage Rated insulation level Power frequency Lightning impulse (BIL) (kvp) primary current (A) Short-circuit current I th Short-circuit current I th S.R. D.R. S.R. D.R. Idin (A) number of cores ACD-7 7,2 20 60 1200 2x600 96 50 2.5xI th 2 ACD-12 12 28 75 1200 2x600 96 50 2.5xI th 2 ACF-12 12 28 75 2000 2x600 100 50 2.5xI th ACI-12 12 28 75 2000 2x600 100 50 2.5xI th ACIL-12 12 28 75 2000 2x600 100 50 2.5xI th ACM-12 12 28 75 2500 2x1000 100 50 2.5xI th ACD-17 17.5 8 95 1200 2x600 96 50 2.5xI th 2 CID-17 17.5 8 95 600-48 - 2.5xI th 1 ACF-17 17.5 8 95 2000 2x600 100 50 2.5xI th ACFR-17 17.5 8 95 2000 2x600 100 50 2.5xI th ACH-17 17.5 8 95 2000 2x600 100 50 2.5xI th ACI-17 17.5 8 95 2000 2x600 100 50 2.5xI th ACIL-17 17.5 8 95 2000 2x600 100 50 2.5xI th ACD-24 24 50 125 1200 2x600 96 50 2.5xI th 2 ACF-24 24 50 125 2000 2x600 100 50 2.5xI th ACH-24 24 50 125 2500 2x600 100 50 2.5xI th ACJ-24 24 50 125 2500 2x600 100 50 2.5xI th ACJL-24 24 50 125 2500 2x600 100 50 2.5xI th ACM-24 24 50 125 2500 2x1000 100 50 2.5xI th ACA-6 6 70 170 1200 2x600 96 50 2.5xI th 1 ACF-6 6 70 170 2500 2x600 100 50 2.5xI th ACH-6 6 70 170 2500 2x800 100 50 2.5xI th ACM-6 6 70 170 2500 2x1000 100 50 2.5xI th ACK-52 52 95 250 2000 2x600 100 50 2.5xI th ACK-72 72.5 140 25 2500 2x1000 100 50 2.5xI th ACP-72 72.5 140 25 2500 2x1000 100 50 2.5xI th Triple primary ratio available. Please consult for details. Subject to technical change. 8

1. CURRENT TRANSFORMERS > Support type DIMENSIONS A A2 C C2 A1 C1 B1 B2 Dimensions and weights (A1) Dimensions (mm) Base (mm) Mounting (mm) (A2) (A) (B1) (B2) (C1) (C2) Hole diameter (C) Weight (kg) ACD-7 255 180 170 180 28 10 140 11 16 ACD-12 255 180 170 180 28 10 140 11 16 ACF-12 245 178 270 178 5 150/155 280/295 11 27 ACI-12 220 148 270 148 7.5 125 270 11 2 ACIL-12 220 148 95 148 472 120 420 12 4 ACM-12 95 260 446 178 408 175 50 11 80 ACD-17 255 180 170 180 28 10 140 11 16 CID-17 140 120 178 120.6 212 95.2 141/151 10 15 ACF-17 245 178 270 178 295 150/155 280/295 11 27 ACFR-17 240 168 270 168 5 145 225 11 26.5 ACH-17 220 178 07 178 80 150 28.5/10.5 11 25 ACI-17 220 148 270 148 7.5 125 270 11 2 ACIL-17 220 148 95 148 472 125 420 12 4 ACD-24 255 180 170 180 28 10 140 11 16 ACF-24 245 178 270 178 295 150/155 280/295 11 27 ACH-24 245 178 25 175 405 155 50 11 ACJ-24 280 178 270 178 45 150 280 14 5 ACJL-24 280 178 95 178 472 150 420 12 4 ACM-24 95 260 446 178 408 175 50 11 80 ACA-6 40 170 170 178 178 10 140 11 16 ACF-6 55 210 270 178 5 150/155 280/295 11 6 ACH-6 54 210 75 178 405 155 50 11 51 ACM-6 95 260 446 178 408 175 50 11 80 ACK-52 475 280 0 20 407 200 250/260 14 70 ACK-72 650 10 55 10 417.5 225 00 14 105 ACP-72 872 55 55 40 429.5 255 00 14 110 Brass primary terminals (silver-plated on request) with M12 zinc-plated, bichromated steel screw. Brass M5/M6 secondary terminals. Zinc-plated, bichromated steel M8/M12 earth terminals. Polycarbonate secondary terminal cover. Zinc-plated, bichromated steel covers available on request. Approximate dimensions and weights. 9

1. CURRENT TRANSFORMERS > Support window type SUPPORT WINDOW TYPE Current transformers for indoor service, encapsulated in resin. Toroidal support type without primary conductor to be installed in medium voltage busbars without insulation. RANGE Insulation voltage from.6 kv to 24 kv. Rated primary currents up to 4000 A. Secondary currents: 1 and 5 A Frequencies: 50 Hz, 60 Hz. APPLICATIONS AGNE Medium voltage air insulated primary distribution switchgears. Capacitor Banks. ADVANTAGES Possibility of secondary currents different from the standardized ones (1 and 5 A). Rated primary currents over 4000 A available. Secondary terminals on the or side. Designs for outdoor service available. Stainless steel screws, bolts and nuts available. AGN AGPE AGD AGN-24 Transformer for generator switchgear. AGNL 10

1. CURRENT TRANSFORMERS > Support window type MARKING RATIO AND ONE SECONDARY > DOUBLE PRIMARY RATIO BY SECONDARY TAPPING AND ONE SECONDARY RATIO AND TWO RATIO AND THREE RATIO AND TWO WITH TAPS S1 S2 S1 S2 S 1S1 1S2 2S1 2S2 1S1 1S2 2S1 2S2 S1 S2 1S1 1S2 1S 2S1 2S2 2S Electrical characteristics Highest voltage Rated insulation level Power frequency Lightning impulse (BIL) (kvp) primary current (A) Short-circuit current I th I th (ka/1s) I din (ka) number of cores AGNE-.6.6 10 40 4000 100 2.5xI th AGPE-.6.6 10 40 4000 100 - AGPE-12 12 28 75 4000 100 2.5xI th AGN-17 17.5 8 95 4000 100 2.5xI th AGNL-17 17.5 8 95 4000 100 2.5xI th 4 AGD-24 24 50 125 1500 100 2.5xI th 1 AGN-24 24 50 125 4000 100 2.5xI th Subject to technical change. DIMENSIONS A2 A C C1 A4 A1 C2 B2 B1 Dimensions and weights Dimensions (mm) Base (mm) Mounting (mm) (A1) (A2) (A) Inner diameter (A4) (B1) (B2) (C1) (C2) Hole diameter (C) Weight (kg) AGNE-.6 97.5 285 20/280 120/150 07 170 255 140 12 42 AGPE-.6 498 70 160 200 70 160 270 10 11 AGPE-12 516 70 290 204 290 70 10 270 11 55 AGN-17 97.5 285 20/280 120/150 285 170 255 140 12 42 AGNL-17 400 290 0 120/140 285 0 255 140 12 55 AGD-24 60 160 156 - - - 6 - M8 11 AGN-24 97.5 285 20/280 120/150 285 170 255 140 12 42 Option to supply with silver-plated copper primary bar on request. Brass M5/M6 secondary terminals. Zinc-plated, bichromated steel M8/M12 earth terminals. Polycarbonate secondary terminal cover. Zinc-plated, bichromated steel covers available on request. Approximate dimensions and weights. 11

1. VOLTAGE TRANSFORMERS > Generator / Wall-bushing type GENERATOR TYPE Current transformers for indoor service, encapsulated in resin. Toroidal type without primary conductor to be installed in generator outputs. RANGE Insulation voltage up to 24 kv. Rated primary currents up to 12,000 A. Higher currents available. Secondary currents: 1 and 5 A. Frequencies: 50 Hz, 60 Hz. ABG APPLICATIONS Power generation. ADVANTAGES Measurement and protection applications. Excellent performance in ambient temperatures up to 80 C. Stainless steel screws, bolts and nuts available. ABF WALL-BUSHING TYPE Current transformers for indoor service, encapsulated in resin. Toroidal model without primary conductor for installation as a wall bushing. RANGE Insulation voltage up to 6 kv. Rated primary currents up to 8,000 A. Secondary currents: 1 and 5 A. Frequencies: 50 Hz, 60 Hz. ABE APPLICATIONS Medium voltage air insulated primary distribution switchgears. Power generation. ADVANTAGES Several inner window diameters. Stainless steel screws, bolts and nuts available. ABD 12

1S1 1S2 2S1 2S2 S1 S2 1. VOLTAGE TRANSFORMERS > Generator / Wall-bushing type MARKING RATIO AND ONE SECONDARY DOUBLE PRIMARY RATIO BY SECONDARY TAPPING AND ONE SECONDARY RATIO AND TWO RATIO AND THREE RATIO AND TWO WITH TAPS S1 S2 S1 S2 S 1S1 1S2 2S1 2S2 1S1 1S2 2S1 2S2 S1 S2 1S1 1S2 1S 2S1 2S2 2S Electrical characteristics Highest voltage Rated insulation level Power frequency Lightning impulse (BIL) (kvp) primary current (A) Short-circuit current I th I th (ka/1s) I din (ka) number of cores ABD-7 7.2 20 60 4000 100 2.5xI th ABD-12 12 28 75 4000 100 2.5xI th ABD-17 17.5 8 95 4000 100 2.5xI th ABD-24 24 50 125 5000 100 2.5xI th ABD-6 6 70 170 5000 100 2.5xI th ABE-12 12 28 75 6000 100 2.5xI th 4 ABE-24 24 50 125 8000 100 2.5xI th 4 ABF-24 24 50 125 6500 100 2.5xI th ABG-24 24 50 125 10000 100 2.5xI th Subject to technical change. DIMENSIONS B1 A C2 A2 B2 A1 C Dimensions and weights Dimensions (mm) Base (mm) Mounting (mm) (A1) (A2) (A) Inner diameter (A4) (B1) (B2) (C1) (C2) Hole diameter (C) Weight (kg) ABD-7 400 275 20 100/10 - - 210 25 16 25 ABD-12 400 275 20 100/10 - - 210 25 16 25 ABD-17 400 275 20 100/10 - - 210 25 16 25 ABD-24 425 50 60 150 50 50 05 05 14 55 ABD-6 425 50 540 150 50 50 05 05 14 100 ABE-12 501.5 422 550 275 405 405 60 60 14 100 ABE-24 501.5 422 500 200 405 405 60 60 14 110 ABF-24 61.5 525 180/240 250 - - - - M16 55 ABG-24 718 625 180/240 50 - - - - M16 55 Brass M5/M6 secondary terminals. Zinc-plated, bichromated steel M8/M12 earth terminals. Polycarbonate secondary terminal cover. Zinc-plated, bichromated steel covers available on request. Approximate dimensions and weights. 1

1. VOLTAGE TRANSFORMERS > Touch-proof type TOUCH-PROOF TYPE Resin-cast transformers with metallic coating for installation in medium voltage switchgears insulated in gas. RANGE Insulation voltage up to 52 kv. Rated primary currents up to 2000 A. Secondary currents: 1 and 5 A.. Frequencies: 50 Hz, 60 Hz. APPLICATIONS Medium voltage primary distribution gas insulated switchgears (GIS). ARTECHE instrument transformers are installed in over 150 countries. ADVANTAGES Possibility of secondary currents different from the standardized ones (1 and 5 A). Possibility of frequencies different from the standardized ones (50 and 60 Hz). Stainless steel screws, bolts and nuts available. 1. VOLTAGE TRANSFORMERS > Wall bushing with primary bar type WALL BUSHING WITH PRIMARY BAR TYPE Current transformers for indoor service, encapsulated in resin. Toroidal type with primary conductor to be installed as wall bushings. RANGE Insulation voltage up to 72.5 kv. Higher voltages also available. Rated primary currents up to 000 A. Secondary currents: 1 and 5 A.. Frequencies: 50 Hz, 60 Hz. APPLICATIONS Distribution substations. APL ADVANTAGES Wall bushings for indoor-indoor or indooroutdoor installations. Stainless steel screws, bolts and nuts available. 14

1. VOLTAGE TRANSFORMERS > Touch-proof type MARKING RATIO AND ONE SECONDARY DOUBLE PRIMARY RATIO BY SECONDARY TAPPING AND ONE SECONDARY RATIO AND TWO RATIO AND THREE RATIO AND TWO WITH TAPS S1 S2 S1 S2 S 1S1 1S2 2S1 2S2 1S1 1S2 2S1 2S2 S1 S2 1S1 1S2 1S 2S1 2S2 2S Electrical characteristics Highest voltage Rated insulation level Power frequency Lightning impulse (BIL) (kvp) primary current (A) Short-circuit current I th I th (ka/1s) I din (ka) number of cores APL-12 12 28 75 000 100 2.5xI th APL-6 6 70 170 000 100 2.5xI th APL-72 72.5 140 25 000 100 2.5xI th Subject to technical change. DIMENSIONS B1 C1 A A1, A2 B2 C2 C Dimensions and weights Dimensions (mm) Base (mm) Mounting (mm) (A1) (A2) (A) Inner diameter (A4) (B1) (B2) (C1) (C2) Hole diameter (C) Weight (kg) APL-12 245 245 675-290 290/400 240/175 240/60 16 44 APL-6 260 260 975-280 65 20 260 16 85 APL-72 260 260 150-280 65 20 260 16 95 Brass M5/M6 secondary terminals. Zinc-plated, bichromated steel M8/M12 earth terminals. Polycarbonate secondary terminal cover. Zinc-plated, bichromated steel covers available on request. Approximate dimensions and weights. Indoor/outdoor wall-bushing in a distribution substation. 15