Commander SE. Simple and Easy. Commander SE. Mixer Simple and Easy. Material Payoff Performance. Overview

Similar documents
Easy to connect - Easy to configure Easy to install

How To Use The Vacon 0 Machinery

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

A1000 Cheat Sheet (Open Loop Vector)

32VFD Variable Frequency Drives for Centrifugal Chillers

Number 1 in efficiency

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Install the DeviceNet Module using the following procedure:

Analog Servo Drive 25A8

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Telephone- and leased line modem for industrial applications TD-36

NX Series Inverters. HVAC Pocket Programming Guide

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

vacon x series rugged drives for the real world

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

AC ADJUSTABLE SPEED DRIVES MICRO SERIES INVERTERS

Phone: Fax: Web: info@clrwtr.com

GPD 506/P5 Start-up Procedure and Checklist

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Specifying a Variable Frequency Drive s

Rack mounted telephone- and leased line modem for industrial applications

HVAC DRIVE H300 HVAC Drive for Building Automation

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

Application/Connection Examples

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

... Electronic Softstarter...

AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use:

GE Energy Industrial Solutions. New. AF-6 Series Drives. Built-in features Built-in simplicity. GE imagination at work

ABB general machinery drives. User s manual ACS355 drives

Frequency Converter Fv

vacon compact ac drives creating perfect harmony

TX OPEN RS232/485 module

FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3

Digital input modules

with Electronic Assistant

PIEZOMETER AIRFLOW MEASURING RING

NXL Series Inverters. HVAC Inverters made simple

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Permissible ambient temperature Operation Storage, transport

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Disturbance Recoder SPCR 8C27. Product Guide

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Multi-Range Programmable DC Power Supplies 9115 Series

vacon 100 x & vacon 20 x decentralized ac drives

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

1 Application Description Objective Goals... 3

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Multi-Range Programmable DC Power Supplies 9115 Series

VARIABLE FREQUENCY DRIVES Revised 4/30/ Mechanical Systems

ABB machinery drives. User s manual ACS355 drives

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Variable speed drives

2011 Industrial Catalog. DRIVES, PAC, PLCs. Industrial Catalog

DC Electronic Loads 8500 series

Softstarters Type PSR

1. SAFETY INFORMATION

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

High Power Programmable DC Power Supplies PVS Series

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

40.3. Control Relays and Timers

PSR The compact range Description

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY

MC1000 Series Installation and Operation Manual

J1000. System configuration

Single and three phase modular Automatic Transfer Switch from 40 to 160 A

Power Supplies 3. SDN-P DIN Rail Series

ZC-24DO CANopen I/O Module: 24 Digital Outputs

PCS0100en Persy Control Services B.V. Netherlands

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

Duct Humidity Transmitter

Configuring Allen-Brandly ControlLogix PLC with Moxa MGate 5105-MB-EIP. 1 Application Description Objective Goals...

AC Variable Speed Drive. Powerful Performance. Advanced motor control. 0.75kW 250kW / 1HP 350HP V Single & 3 Phase Input

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

Softstarters. Type PSTX Fieldbus communication, Built-in Modbus RTU. 1SFC132089M0201 April SFC132089M0201 1

DCS Series 1 kw, 1.2 kw, & 3 kw

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

NC-12 Modbus Application

MEMOBUS/Modbus Communications

STRATO LED Drivers 70W, Single output

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Absolute Rotary Encoder E6CP

CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

VLT 6000 HVAC. Contents

HVAC03C2 HVAC61C2 HVAC03C5 HVAC61C5 NXL HVAC INVERTERS

Installation manual. Generator Paralleling Controller GPC multi-line C

vacon 100 hvac premium ac drive for indoor climate control

IntesisBox KNX Mitsubishi Heavy Industries AC

T Substation Maintenance and Commissioning Test Equipment

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Repeaters and Mimics Data Sheet

Transcription:

www.emersonct.com Simple and Easy Overview Control Techniques economical microdrive is an AC open loop vector powerhouse, combining unmatched flexibility with a small footprint. Best of all, the is simple to use and easy to install. The s first 10 parameters meet the needs of 80% of drive applications, making setup fast and effortless. Installation requires only a standard screwdriver, while the removable control terminal strip makes changeover quick and error free. The rugged and robust design has been field tested in harsh environments and proven itself a dependable drive for a wide range of applications. The Commander SE, with its Intelligent Thermal Management (ITM) technology, was designed with reliability in mind. Rated at 50 C ambient temperature, the withstands the most severe operating conditions. Mixer Simple and Easy Digital AC Drive 1/3 to 3 HP, 1 phase, 230 VAC 1 to 10 HP, 3 phase, 230 VAC 1 to 50 HP, 3 phase, 460 VAC NEMA 1 (IP21) enclosure RS485 serial communications with Modbus RTU protocol Plug-in communications via Profibus-DP, DeviceNet, and Interbus-S SESoft Windows based configuration tool QuicKey cloning module Ideal for pumps, conveyors, mixers, fans, ovens and more Advanced menus for ultimate control and flexibility Complete Motor Solutions Material Payoff Performance ISO 9002 A P P R O V A L 16

1-800-893-2321 Feature Performance Advantage Open loop vector control with true space vector modulation Precise control algorithm provides full torque down to 1 Hz for exceptional performance Access to multiple parameter levels Customizes the drive to meet each user s needs: simple (level 1), flexible (level 2) and advanced (level 3) QuicKey cloning module Provides fast and cost-effective drive-to-drive parameter transfer and storage with no PC required Terminal connection drawings and Level 1 parameters (10) listed on the drive s front cover On-the-spot easy reference for drive set-up and maintenance Static auto-tune Allows fast motor / drive optimization without motor shaft rotation Two sets of motor map parameters saved in the drive s memory Allows sequenced switching between two motors with different operating characteristics Configurable analog and digital I/O Customizes drive to the specific application S-ramp accel / decel profiling Provides smooth speed transitions, minimizing machine jerk Built-in independent PID control Eliminates the need for an external PID controller while providing outer loop control of a process variable Built-in MOP (motorized potentiometer) Emulates the functionality of the traditional MOP with increase / decrease pushbuttons 8 Preset speeds with independent accel / decel ramps Allows predetermined speed sequencing via logic inputs Selectable Stopping modes including Ramp, Coast, DC Injection, and Dynamic Braking (except size 1) Added flexibility meets many application requirements Full EMC compliance with optional filter Meets global standards for worldwide use Ratings: SINGLE OR THREE PHASE INPUT.33 to 10 HP (208-230 VAC) 1 to 50 HP (380-460 VAC) 208 / 230 VAC Motor HP➀ Input Phase 0.33 1 1.5 2.25 1 SE11200025 0.50 1 2.3 3.45 1 SE11200037 0.75 1 3.1 4.65 1 SE11200055 1 1 4.3 6.45 1 SE11200075 1 1 or 3 4.3 6.45 2 SE2D200075 2 1 or 3 7.5 11.3 2 SE2D200150 3 1 or 3 10 15 2 SE2D200220 5 3 17 25 2 SE23200400 7.5 3 25 37.5 3 SE33200550 10 3 28.5 42.8 3 SE33200750 380 / 480 VAC Motor HP➀ Input Phase Order String Contin. Output Current (A) Contin. Output Current (A) Overload Current➁ (A) Overload Current➁ (A) Size Size Catalog Number Catalog Number 1 3 2.1 3.15 2 SE23400075 2 3 4.2 6.3 2 SE23400150 3 3 5.8 8.7 2 SE23400220 5 3 9.5 14.3 2 SE23400400 7.5 3 13 19.5 3 SE33400550 10 3 16.5 24.8 3 SE33400750 15 3 24.5 36.8 4 SE43401100 20 3 30.5 45.8 4 SE43401500 25 3 37 55.5 4 SE43401850 30 3 46 69.0 5 SE53402200 40 3 60 90.0 5 SE53403000 50 3 70 105.0 5 SE53403700 ➀ Motor HP is based on four pole, 230 / 460 VAC NEMA ratings. ➁ Overload: 150% for one minute. SE X X X X X X X X Drive Kilowatt Rating Place Holder (0) Drive Voltage Rating: 2 = 208-230 VAC 4 = 380-460 VAC Input Phase: 1 = 1, D = 1 & 3, 3 = 3 Size: 1, 2, 3, 4, 5 Product Family 17

www.emersonct.com Terminal Diagram: Terminal Description Pin # Function ➀ Type/Description Notes 1 0V Common Common for External Analog Signals 2 Analog Input 1 Single-ended 0 to +10 VDC, (Local Frequency / Analog Input 100k Ohms, Speed Reference), 10 bit Sample Time 6ms 3 +10 VDC User Supply Reference Supply 5 ma max Short Circuit Protected 4 0V Common Common for External Digital Signals 5 Analog Input 2 Single-ended 4-20 ma➁ input, (Remote Frequency / Analog Input 200 Ohms, Speed Reference), 10 bit Sample Time 6ms 6 Analog Output 1 Single-ended 0 to +10 VDC (Frequency / Speed), 10 bit Analog Output, @ 5 ma max Unipolar Update Time 22ms 7 +24 VDC User Supply User Supply 100 ma max Short Circuit Protected 8 Digital I/O 1 Digital 0 to 24 VDC, (Zero Speed Output) Input / Output input or 0 to 24 VDC, 50 ma max output Pin # Function ➀ Type/Description Notes 9 Digital Input Digital Input 0 to 24 VDC, (Enable) 10 Digital Input Digital Input 0 to 24 VDC, (Run Forward) 11 Digital Input Digital Input 0 to 24 VDC, (Run Reverse) 12 Digital Input Digital Input 0 to 24 VDC, (Local/Remote Select) 13 Digital Input Digital Input 0 to 24 VDC, (Jog Select) 14 +24 VDC User Supply User Supply 100 ma max Short Circuit Protected 15 Status Relay (Drive Healthy) Normally Open 240 VAC, 6A resistive 16 Status Relay (Drive Healthy) Normally Open 240 VAC, 6A resistive Programmable Analog Programmable Digital All Analog I/O is scaleable ➀ Values in parenthesis designate default functions. ➁ 0-20, 20-0, and 20-4 ma are also available. See Manual. 18

1-800-893-2321 Specifications: Ambient Operating Temperature Cooling method Humidity Storage Temperature Altitude Environment -10ºC to 40ºC (14ºF to 104ºF) @ 6kHz carrier freq. -10ºC to 50ºC (14ºF to 122ºF) @ 3kHz carrier freq. For SE Size 4 25HP and all SE Size 5's. -10ºC to 40ºC (14ºF to 104ºF) @ 3kHz carrier freq. Convection and forced convection, model dependent 95% maximum non-condensing at 40ºC (104ºF) -40ºC to 60ºC (-40ºF to 140ºF) -- 12 months Max. Derate the continuous output current by 1% for every 100m (328 ft) above 1000m (3280 ft) to a maximum of 4000m (13,000 ft). Vibration Tested in accordance with IEC 68-2-34 and IEC 68-2-36 Mechanical Shock Tested in accordance with IEC 68-2-29 Enclosure NEMA 1 (IP 21) Electromagnetic In compliance with EN61800-3 and EN50082-2 Immunity Electromagnetic In compliance with EN61800-3 Emissions second environment, without RFI filter. EN50081-1*, EN500821-2 and EN50081-3 first environment with optional RFI filter. *Size 1 only Drive Overload Trip Instantaneous Overcurrent Trip Phase Loss Trip Overtemperature Trip Short Circuit Trip Ground Fault Trip Motor Thermal Trip Current overload value is exceeded. Programmable to allow up to 150% of drive current for one minute. 215% of drive rated current DC bus ripple threshold exceeded Drive heatsink temperature exceeds 95 C (203ºF) Protects against output phase to phase fault Protects against output phase to ground fault Electronically protects the motor from overheating due to loading conditions Approvals & Listings UL, cul UL File #E171230 IEC Meets IEC Vibration, Mechanical Shock and Electromagnetic Immunity Standards CE Designed for marking NEMA NEMA 1 enclosure type ISO 9002 Certified Manufacturing Facility Dimensions AC Supply Requirements Voltage 200V model: 200 to 240 VAC ±10% 400V model: 380 to 480 VAC ±10% Phase 1Ø and 3Ø (Model Dependent) Maximum Supply 2% negative phase sequence (3% voltage Imbalance imbalance between phases) Frequency 48 to 62 Hz Input Displacement 0.97 Power Factor Control Carrier Frequency 3, 6 and 12 khz (Default Value Model Dependent) Output Frequency Up to 1000 Hz Frequency Accuracy ±0.01% of full scale Frequency Resolution 0.1 Hz Analog Input 10 Bit + sign (Qty 2) Resolution Serial Communications ANSI 2-wire EIA485 via RJ45 connector. Baud rate is 4800, 9600 or 19,200 Braking DC injection braking standard. Dynamic braking transistor standard (not available on Size 1). DC Bus Undervoltage Trip DC Bus Overvoltage Trip MOV Voltage Transient Protection Protection 200V model: 180 VDC (approximately 127 VAC line voltage) 400V model: 400 VDC (approximately 282 VAC line voltage) 200V model: 420 VDC (approximately 299 VAC line voltage) 400V model: 830 VDC (approximately 587 VAC line voltage) 160 Joules, 1400 VDC clamping (Line to line and line to ground) 19

www.emersonct.com Options / Software / Accessories Overview This simple and easy drive also provides flexibility with easy to install options. Drive set-up is quick and convenient using our remote keypad or SESoft, our Windows based configuration tool. The SE QuicKey allows parameter cloning for fast parameter storage and transfer, making it easy to add or replace drives within your system. The easily connects into your network with a wide range of fieldbus protocols and operator interface options. At-A-Glance Option Description Catalog Number Input / Output Bi-polar Analog Input Card SE51 Memory QuicKey Cloning Tool SE55 Communication RS485 / Modbus RTU Standard Profibus-DP SE73 Interbus-S SE74 DeviceNet SE77DN CANOpen SE77CO PC to Drive Configuration Tool SESoft Accessories RS232/485 Cable SE71 Operator Remote Keypad CTKP Interface CT Operator Interface CTIU Accessories Cable Shield Clamps SE11 to SE14 Extended 5-year Warranty SE1WE to SE5WE Warranty 20

1-800-893-2321 Memory Input / Output Modules Bi-polar Analog Input Card (SE51) The bi-polar speed reference input card (SE51) allows the direction of a motor to be controlled via a speed potentiometer or external bi-polar speed reference rather than the forward/reverse terminal selector. The +10V potentiometer reference can be supplied from the drive (term. #3) or from an external power supply. The 10V potentiometer reference must be supplied from an external supply. The SE51 also has a relay that is controlled by the digital output (default zero speed ) of the drive. QuicKey / Cloning Module (SE55) The QuicKey is a small, encapsulated memory module that stores the entire set of the drive s parameter values. It plugs onto the SE drive near the control terminals. The may be programmed to download / upload a set of parameters to / from the QuicKey or to operate with or without the module installed. Once the information is stored in the QuicKey, it may be removed from the drive for future use such as cloning other drives or programming a replacement drive. Communications SE51 Terminal Diagram Communication Cards (SE73, SE74, SE77DN, SE77CO) Each fieldbus interface for the is a single option card that fits within the drive. Parameter data is transferred to and from the using a 2-wire RS485 link into the RJ45 serial communications port on the drive. SE51 Terminal Description Signal Connector Pin # Function PL1 1 Bi-polar Analog Input (±10 VDC, 22k Ohms) 2 0V Common PL2 1 0V Common (Interface 2 0 to +10 VDC Analog Output connections 3 +24 VDC Supply for option card to ) 4 Digital Input (+24 VDC) to control relay 5 Run Forward Output (+24 VDC)* 6 Run Reverse or Run Forward / Reverse Output (+24 VDC)* PL3 1 Relay Contact Common (48 VAC / DC, 2A resistive) 2 Relay Contact (Normally Open) * Directional control of Communication Interface Card Protocol* Catalog Number RS485 / Modbus RTU Standard Profibus-DP SE73 Interbus-S SE74 DeviceNet SE77DN CANOpen SE77CO * Maximum communication rate through RJ45 port is 19.2 kbaud. operates as slave node only. 21

www.emersonct.com PC to Drive Accessories Drive Configuration Tool (SESoft) SESoft is a complimentary Windows based drive configuration tool designed to enable the complete control and display of all parameters within a. A set-up wizard guides the user in entering motor and application data. Motor data may be supplied from the motor nameplate, or the user may select a motor from the database supplied in the wizard. A monitoring screen displays real-time drive values such as current, voltage and DC bus level. SESoft communicates via the computer s serial port and the s RJ45 port using the CT Comms Cable. For more information, refer to the Accessories Section on page 138. Programming / Configuration Cable Using a special RS232 to RS485 converter you can connect the PC to the RJ45 serial port on the front of the drive. A special pre-made cable is available from Control Techniques for this purpose this same cable is used with other Control Techniques products that use a RJ45 RS485 connector such as the Unidrive SP. Catalog Number CT Comms Cable Description PC-to-drive Comms Cable 22

1-800-893-2321 Accessories Operator Interfaces Universal Keypad (CTKP) The CTKP Universal Keypad is an ideal maintenance tool for use with CT s digital drives (SE, Unidrive, Mentor II, Quantum III) and option modules (UD7X, MD series). Five navigation keys and plain text parameter descriptions make the CTKP easy to use for viewing and modifying drive data. The keypad is designed for hand held or panel mounting. The IP65 rating, screw-down terminals and stress relief for cable connections assure a rugged and robust design. An RS485 cable with an RJ45 connector on the end and dressed wires on the CTKP end is available (order Catalog Number CTKP-SE-485-XXX). (XXX=ft.) For more information, refer to the Accessories Section on page 154. Operator Interface Unit (CTIU) The CTIU operator interface units incorporate a back-lit LCD display and easy-to-use navigation keys. Using the WYSIWIG page editor, they can be programmed to display a variety of menus, submenus, alarms, fault conditions and other critical information. The CTIUs support a range of capabilities including multiple font sizes, real time trends and graphs, scheduling and background programs. They communicate via 2 or 4-wire RS485 and, to simplify installation, CTIUs are rated NEMA 4/12 and require no screw mounting holes. An RS485 cable with an RJ45 connector on the end and dressed wires on the CTIU end is available (order Catalog Number CTIU-CTD-485-XXX). (XXX=ft.) For more information, refer to the Accessories Section on pages 152-153. Cable Shield Clamps The cable shield clamps are used with the to stabilize wire / cable connections when mounting a drive inside an enclosure. The clamps attach to the bottom of the Commander SE drive and provide a convenient shielded ground connection. Clamp Catalog Number Warranty SE11 1 SE12 2 SE13 3 SE14 4 Extended Warranty Size An industry-leading two-year warranty is standard for drives. An extended warranty is available that increases the warranty period to five years. Size Catalog Number 1 SE1WE 2 SE2WE 3 SE3WE 4 SE4WE 5 SE5WE CTIU Family 23