Temp / RH / CO 2 Hand-Held Meter

Similar documents
Soil Sensor Reader PRODUCT MANUAL

INSTRUCTION MANUAL DTH Fax: (503)

A-Series Data Loggers PRODUCT MANUAL

User's Guide. Pinless Moisture Meter. Model MO257

User Manual. Humidity-Temperature Chart Recorder. Model RH520

User Guide. Temperature and Humidity Datalogger. Model 42280

1000 Series Data Loggers PRODUCT MANUAL

4-Channel Thermometer / Datalogger

High Temperature InfraRed Thermometer with Laser Pointer

Dual Laser InfraRed (IR) Thermometer

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Temperature Humidity Meter

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Professional Thermohygrometer

Microwave Meter. Instruction Manual

Model: Manual DC: WIRELESS COLOR FORECAST STATION

Dual Laser InfraRed (IR) Thermometer with Color Alert

Dual Laser InfraRed (IR) Thermometer

Instruction Manual Temp 4/5/6 Temperature Meter Series

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

Mold Alert... Operation Manual P0270

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

ExStik TM ph Waterproof Meters

User's Guide Integrating Sound Level Datalogger Model

Thermistor Thermometer MODEL NO

CM100. Carbon Monoxide Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Användarhandbok

EzFlex Combustible Gas Leak Detector Model EZ40

Owner s Guide. ca6554

Light Meter (Foot Candles)

el-720 Carbon Dioxide Gas Leak Detector User s Guide

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Table of Contents Function Keys of Your RF Remote Control Quick Setup Guide Advanced Features Setup Troubleshooting

TOUCH SCREEN WEATHER STATION MODEL WS Operation Manual

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

CO-220 Carbon Monoxide Meter

User Manual of WT 493

Weather Radio Alarm Clock

AlcoScan AL-5000 User s Manual

Automatic Phone-Out Home Monitoring Systems

Temperature, Humidity & Dew Point Chart Recorder

WIRELESS MULTI-ZONE DIGITAL WEATHER CENTER. Model No User s Manual

Alarm Clock USER GUIDE

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

Wireless Indoor/ Outdoor Thermometer

Pocket Tach 99 (PT99) Non-Contact Tachometer

EE7016 EchoStream Survey Kit

IN-OUT Thermometer with Cable Free Sensor and Clock

Hygro-Thermometer + InfraRed Thermometer Model RH101

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

BW TECHNOLOGIES GasAlertMicroClip Soft Tools Instruction Sheet

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

WIRELESS FORECAST STATION

Milwaukee USER MANUAL

PK5500 v1.1 Installation Instructions

Hand-held thermometer Model CTH7000

1 For All Non-Programmable Digital Thermostat

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

WIRELESS WEATHER STATION Model USER'S INSTRUCTIONS

Wireless Home Security Alarm System AM 500

Manual Ranging MultiMeter

Atomic Alarm Clock model 13131W2

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

Ground Resistance Clamp-On Tester

User Guide. Soft-Touch TM Bluetooth Laser Mouse N2953

AutoRanging Digital MultiMeter

RT-1261A Ear and Forehead Thermometer Owner s Manual

VIBRATION WATCH with: Vibration Alarm (won't disturb others). Beep Alarm (optional) Electro-Luminescent (EL) back light (for viewing display at

Digital Cooking Thermometer models / 00282

INSTALLER S & OWNER S MANUAL

Digital Cooking Thermometer model 03168

User s Manual. Bluetooth Calculator Keypad. Page

AGRI-ALERT 800T / AGRI-ALERT 800 ALARM SYSTEM USER MANUAL

VIBRATION WATCH with:

User s Manual Before using the inverter, you need to read and save the safety instructions.

All Hazards Weather Alert Radio WR-100

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500 Series Low-Cost Data Loggers and Accessories

Ultrasonic Distance Meter. Operation Manual

Integrating Sound Level Meter and Datalogger

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Atomic Dual Alarm Clock models / 13035

Reference Guide. Vantage PRO2 Quick

How To Use A Meter

NortechCommander Software Operating Manual MAN R6

HomeSitter HS-700. Installation and Operations Manual. Protected Home A Division of Control Products, Inc Lake Drive West Chanhassen, MN 55317

Tympanic Thermometer

HVAC Clamp Meter. Users Manual

Data-Logging Rain Gauge PRODUCT MANUAL

Thermocouple Thermometer Models

Intelli-Time Alarm Clock model 13027

ST815 Illumination Sensor with LCD

323/324/325. Calibration Manual. Clamp Meter

PR-2500 Portable Receiver. Owner s Manual

AD-01 Slave Auto Dialer. Owner s Manual

BEP FD-2 CONTOUR MATRIX FUME DETECTOR

ER102. Emergency Crank Weather Radio Owner s Manual.

CT-001, CT-001-Solar Owner s Manual

Transcription:

Temp / RH / CO 2 Hand-Held Meter PRODUCT MANUAL Item # 3440

CONTENTS Specifications 2 Battery 3 LCD Display 3 Keypad 3 Operation 4 Troubleshooting 7 Warranty 8 CE Declaration of Conformity 8 Thank you for purchasing the Temp/RH/CO 2 Hand-Held Meter. With an NDIR (non-dispersive infrared) CO 2 sensor, this unit is stable for long-term monitoring. Please read this manual thoroughly before using your meter. Specifications CO2 Range Accuracy Pressure Dependence Temperature Range Accuracy Humidity Range Accuracy Warm up Power Battery life 2 0 to 5000 ppm ±50ppm, ±5% of reading +1.8% reading / 10hPa deviation from 1000hPa -14 to 140 F (-10 to 60 C) ±0.9 F (±0.6 C) 0 to 99.9% RH ±3% (10-90%), ±5%(other) 30 seconds 4 AA batteries (or 9VDC, 1A adaptor, not incl.) 24 hours (alkaline)

Battery Install the 4 AA batteries into the battery compartment on the rear and make sure they are in correct polarity. When the battery voltage gets low, the battery icon and Lob will appear on the LCD, and the beeper will sound (press any key to stop the beeps). LCD Display Symbols HOLD TWA STEL MIN/MAX DP AIR WBT Readings are frozen Time weighted average (8 hours) Short-term exposure limit (15 min wt avg) Minimum/Maximum readings Dew point temperature Air temperature Wet bulb temperature Keypad 3

4 Operation Power On/Off Press the On/Off/Set key to turn the meter on or off. During warm-up, it will perform a 30 second countdown, then will display current CO 2, temperature, and humidity. The meter turns off automatically after 20 minutes of inactivity. To bring the meter to non-sleep mode, press and hold SET and HOLD for 2 to 3 seconds. You should see a character (n) appear on the LCD display. At this point, let go of the buttons to cancel the automatic power-off function. Taking a Measurement The meter measures continuously and updates the LCD every second. With a significant environmental change, the CO 2 sensor requires 30 seconds, and the RH sensor 30 minutes to respond. Note: Do not hold the meter close to the face because exhalation affects the CO 2 reading. Switch Temperature Measurement Press the DP/WBT key to cycle the temperature display between air, dew point, and wet bulb temperatures. Data Hold Press the HOLD button to freeze the readings. HOLD will display on the LCD. Press HOLD again to cancel the hold function. Backlight Hold the MODE button for more than 1 second to activate and cancel the backlight function. MIN, MAX, STEL, TWA Press the M N X/AV button to switch between the normal, minimum, maximum, and weighted average readings. In MIN and MAX modes, minimum and maximum readings for CO 2, air/dew point/wet bulb temperature, RH will display. In STEL and TWA modes, the display shows the weighted average of the CO 2 readings for the past 15 minutes (STEL) or 8 hours (TWA), as well as the current readings for air/dew point/wet bulb temperature, and RH.

Data Hold The data hold function works in both IR and probe modes. In IR measurement, just release MEAS button, the meter stops measuring and holds the last reading until next measurement is taken or power off. To hold the data in probe measurement, release MEAS button and wait until it gets the stable reading. Then the HOLD icon will display on the top of LCD along with the held reading. Setup In normal mode, hold down the SET button for at least 1 second to enter setup mode. To exit setup, press the CAL/ESC button. P1.0 Set CO 2 Alarm When entering setup mode, AL and P1.0 are displayed on the LCD. Press the M N X/AV button to enter P1.1 to set the CO 2 alarm threshold. The current value will be blinking on the LCD. Press MODE (up-arrow) to increase the value, or DP/WBT (down-arrow) to decrease it. Press the M N X/AV button to save the value, or CAL/ESC to exit without saving. The meter features audible alarm to warn by emitting 80dB beeps when the CO 2 concentration exceeds the limit. The alarm can be stopped by pressing any button except SET. It will also stop when readings fall below the set value. P3.0 Set Temperature Units From the P1.0 display, press MODE (up-arrow) or DP/WBT (down-arrow) to change to the P3.0 screen ( Unit will display on the LCD). Press the M N X/AV button to enter P3.1 to set the temperature units. The current units, C or F, will be displayed on the lower left area of the LCD. Press MODE (up-arrow) or DP/WBT (down-arrow) to switch between C and F. Press the M N X/AV button to save the setting, or CAL/ESC to exit without saving. To exit setup, press the CAL/ESC button. CO 2 Calibration The meter is calibrated at the factory to a standard 400ppm 5

CO 2 concentration. It is suggested to do a manual calibration regularly to maintain good accuracy. The calibration should be done during sunny weather in fresh outdoor air that is well-ventilated. CAUTION: Do not calibrate the meter in the air with an unknown CO 2 concentration. It will be calibrated as 400ppm, which can lead to inaccurate measurements. Place the meter in the calibration site. Turn on the meter and hold down CAL/ESC and MODE simultaneously to enter CO 2 calibration mode. 400ppm and CAL will blink on the LCD while performing the calibration. Wait about 5 minutes for the calibration to complete, which is indicated by the blinking stops and LCD returns to normal mode. To abort the calibration, turn off the meter at any time. NOTE: Ensure the batteries are at full power during the calibration to prevent interruption or a failed calibration. RH Calibration Humidity calculations on the meter can be recalibrated using 33% and 75% salt solutions. Ambient conditions should be at 25 C or 77 F, with stable humidity. Plug the sensor probe into a 33% salt bottle. Hold down the CAL/ESC and DP/WBT buttons until CAL is blinking on the LCD display. In approximately 60 minutes CAL will stop blinking, indicating the end of this phase. To skip the 75% recalibration, press CAL/ESC to exit. Plug the sensor probe into the 75% salt bottle, then press the M N X/AV button. CAL will blink on the LCD until the calibration is completed in approximately 60 minutes. The 33% calibration can be skipped by pressing MODE (uparrow) or DP/WBT (down-arrow) during the first 5 minutes of the 33% calibration step above. 6

Troubleshooting Unable to power on Press the On/Off/Set key for more than 0.3 seconds and try again. Check whether the batteries have good contact and the correct polarity. Readings do not change Check whether data hold function was activated (HOLD icon at the left top). Slow sensor response Check whether the air flow channels on the back of the meter are blocked. Error messages E01: CO 2 sensor damaged. E02: The value is under range. E03: The value is over range. E04: Error code for dew point or wet bulb accompanying a primary sensor failure code. E07: Too low voltage to measure CO 2. Replace batteries. E11: Retry humidity calibration. E17: Retry CO 2 calibration. E31: Temperature sensor damaged. E34: Humidity sensor damaged. 7

Warranty This product is warranted to be free from defects in material or workmanship for one year from the date of purchase. During the warranty period Spectrum will, at its option, either repair or replace products that prove to be defective. This warranty does not cover damage due to improper installation or use, lightning, negligence, accident, or unauthorized modifications, or to incidental or consequential damages beyond the Spectrum product. Before returning a failed unit, you must obtain a Returned Materials Authorization (RMA) from Spectrum. Spectrum is not responsible for any package that is returned without a valid RMA number or for the loss of the package by any shipping company. This equipment has been manufactured for Spectrum Technologies, Inc. 12360 S. Industrial Dr. East Plainfield, IL 60585 USA The Manufacturer s DECLARATION OF CONFORMITY is on file at the above address, and certifies conformity to the following: Model Number: 3440 Description: Temp/RH/CO2 Hand-Held Meter Type: Electrical Equipment for Measurement, Control, and Laboratory Use Directive: 2004/108/EC Standards: EN 61326-1 (2006) EN 61000-3-2 (2006) EN 61000-3-3 (1995/A1:2001/A2:2005) EN 61000-4-2 (1995/A1:1998/A2:2001) EN 61000-4-3 (2006) /-4(2004) /-5(2006) EN 61000-4-6 (1996/A1:2001) /-11(2004) 8 12360 S. Industrial Dr. E Plainfield IL 60585 (800) 248-8873 or (815) 436-4440 Fax (815) 436-4460 E-Mail: info@specmeters.com www.specmeters.com R 10/12