INVERTER USER S MANUAL 1500VA. DC / AC Power Transfer System

Similar documents
How To Use A Power Supply Unit (Upu)

User s Manual AURORA 1.2K/2.2K

Online UPS. PowerWalker VFI 1000R/1U

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

User Manual 1K/2K/3K Online UPS

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

USER MANUAL Online UPS 1K/2K/3K

10000HXL31/15000HXL31/20000HXL31

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

USER MANUAL Online UPS 1K/2K/3K Rack

Line Interactive UPS. PowerWalker VI 500T/HID PowerWalker VI 750T/HID PowerWalker VI 1000T/HID PowerWalker VI 1500T/HID.

Line Interactive UPS

MAJORSINE Power Inverter

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Back-UPS Pro 1300/1500 Installation and Operation

User s Manual. Professional Rack Mount LCD Series PR1000ELCDRT2U/PR1500ELCDRT2U/ PR2200ELCDRT2U K

Powerware 5110 UPS User s manual

Uninterruptible Power Supply

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

User s Manual Before using the inverter, you need to read and save the safety instructions.

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Installation and Operation Back-UPS 1250, 1300, 1500

ekil 3 KGK tecrübesi olmayan herhangi bir ki i tarafından çalı tırılabilir.

How To Use A Power Supply Unit (Upland)

PowerGem Pro Uninterruptible Power Supply

INV Series Sine-Wave Inverter. Manual INV12/220-XXXX KLC INV24/220-XXXX KLC INV48/220-XXXX KLC INV110/220-XXXX KLC INV220/220-XXXX KLC

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

=============================== WARNING

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

HP UPS R1500 Generation 3

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

TIG INVERTER INSTRUCTION MANUAL

Delta UPS - Amplon Family. User Manual. E Series, Single Phase 1/2/3 kva. The power behind competitiveness ON OFF ON LINE

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

Manual Ranging MultiMeter

MCR1900 Media Converter 19-Slot Chassis

AutoRanging Digital MultiMeter

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

3000W Power Inverter

INSTALLATION & SERVICE MANUAL. Display Panel

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

700 VA VA UPS. User s and Installation Manual. EMC Statements. FCC Part 15 ICES-003

DIV Series Sine-Wave Inverter System Manual DIV12/220-XXXX L/W DIV24/220-XXXX L/W DIV48/220-XXXX L/W DIV220/220-XXXX L/W DIV220/220-XXXX L/W

LAP ENERGIA PARA DATACENTERS

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

Liebert GXT3 UPS 230V 700VA-3000VA

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

350, 500, 650 and 1000 MODELS

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

Model #: SMART2200CRMXL

Battery Power Inverters

UPS VA User s Manual

Table Of Contents

FRUK19-6K / FRUK19-10K / FRUK19-15K ONLINE-UPS

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Technical Data. back-up time in minutes 100% load % load

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

Liebert GXT3 UPS 120V/208V 500VA-3000VA

Thyristor-controlled power supplies and battery chargers

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

USER MANUAL. 914 Power Amplifier MODEL: P/N: Rev 1

BroadBand PowerShield. User Manual

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

TOA 900 SERIES II MIXER POWER AMPLIFIER

Troubleshooting and Diagnostics

GB USER S MANUAL GB 41

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

7 FUNCTION DIGITAL MULTIMETER

Home Solar Kit Owner s Manual. Model: HS

S4K2UC Industrial On-line UPS. 120 V, 700 VA 3000 VA User Manual

User Manual for CH-PFC76810

User Manual. English. APC Smart-UPS VA 120/230 Vac VA 100/120/208/230 Vac. 2U Rack Mount Uninterruptible Power Supply

HM-W536 Install Guide

USER MANUAL Online UPS 6K/10K RACK

AC-115 Compact Networked Single Door Controller. Installation and User Manual

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

Transcription:

INVERTER DC / AC Power Transfer System 1500VA USER S MANUAL 0

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING (Controlled Environment) : Intend for installation in a controlled environment. WARNING (Fuses): To reduce the risk of fire, replace only with the same type and rating of fuse. CAUTION (Live Heat Sink): Risk of electric shock-heat sink is live. Disconnect unit before servicing. CAUTION: Do not dispose of batteries in a fire, the battery may explore. CAUTION: Do not open or mutilate the battery, released electrolyte is harmful to the skin and eyes. It may be toxic. CAUTION: A battery can present a risk of electric shock and high short circuit current. The following precaution should be observed when working on batteries Remove watches, rings or other metal objects. Use tools with insulated handles. Wear rubber gloves and boots. Do not lay tools or metal parts on top of batteries. Disconnect charging source prior to connecting or disconnecting battery terminals. DANGER (DC Supplies Over 60V): Risk of electric shock. Do not touch uninsulated battery terminals. Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries. When replacing batteries, replace with the same number and type. The right way to de-energize the Inverter properly in an emergency is to move the I/O switch to the OFF position and disconnect the power cord from the mains supply. 1

TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS..... 1 TABLE OF CONTENTS....2 INTRODUCTION.........2 1. PRESENTATION....... 3 2. INSTALLATION. 6 3. OPERATION.. 6 4. ALARMS.... 7 5. SOFTWARE OPTIONS AND COMPUTER INTERFACE PORT. 7 APPENDIX A. TROUBLESHOOTING. 9 APPENDIX B. SPECIFICATIONS 10 INTRODUCTION Please read and save this manual! Thank you for selecting this Inverter. It provides you with a perfect protection for connected equipment. The manual is a guide to install and use this system. It includes important safety instructions for operation and correct installation of the Inverter. If you should have any problems with the Inverter, please refer to this manual before calling customer service. Intelligent microprocessor control The product is an advanced Inverter based on dual-microprocessor control. This means that it operates with the newest technology, high performance and powerful function. DC INPUT FUSE BOOST DC/DC INV DC/AC RELAY EMI FILTER AC OUTPUT Figure. System block diagram. 2

1. PRESENTATION Front LED Panel INVERTER Front LCD Panel 1.1 INV or INVERTER indicator The indicator illuminates when the unit is working and output power is provided from the unit. It also ensures that the output power is provided from the inverter circuit. 1.2 BACKUP indicator (LCD Panel only) The indicator illuminates when the power is supplied from the DC power or inter/external batteries. 3

1.3 FAULT indicator It shows something wrong concerning about the Inverter. 1.4 ON button With the Inverter is plugged in, press the ON button to turn on the Inverter and power on the loads. 1.5 OFF button Press the OFF button to turn off the Inverter and the loads. 1.6 SELECT button (LCD Panel only) The relevant value appears on the upper screen. There are two display modes can be selected. Output voltage display Temperature inside the unit 1.7 BATT bar graph (RECTANGLE INDICATOR) The rectangle indicator shows the percentage of battery capacity. 1.8 LOAD bar graph (RECTANGLE INDICATOR) The indicator shows the power being drawn by the load. 1.9 FAULT codes (LCD Panel only) The relevant value appears at the upper screen. There are seven kinds of fault modes can be displayed. E01: Warning of fail output E02: Warning of wrong temperature E03: Warning of output short circuit E04: Warning of overload (exceeding 150%) E05: Warning of mistaken +/- DC Bus E06: Warning of wrong input DC voltage E07: Warning of input DC power is not enough Load Indicator Light no.5 Light no.4 Light no.3 Light no.2 Light no.1 % of Load Value over 96% 76-95 % 51-75 % 26-50 % 10-25 % Battery Indicator Light no.5 Light no.4 Light no.3 Light no.2 Light no.1 % of Bat Level over 91 % 76-90 % 51-75 % 26-50% 0-25% 1.10 OUTPUT POWER RECEPTACLES 1.11 DC INPUT POWER RECEPTACLE 4

Rear Panel (Tower type) Rear Panel (Rack-Mount type) FRONT VIEW REAR VIEW 5

2. INSTALLATION 2.1 Inspect Inspect the Inverter upon receipt. The packaging is recyclable; keep it for reuse or be disposed of properly. 2.2 Placement Install the Inverter in a protected area with adequate flowing air and free of excessive dust. Do not operate the Inverter where the temperature and humidity is out of the specified limits. 2.3Connect the input power Please connect the unit to the DC telecom power or a dc power supplier/batteries. Please make sure the DC rating is match with the rating label. For example, DC 48 V described on the label means input voltage should be DC 48 V. 2.4 Connect the loads Connect the loads with the terminal block at the rear of the Inverter. To use the UPS as a master on/off switch, make sure all of the loads are switched on. 3. OPERATION 3.1 Switch on While utility input is connected to the Inverter, press the "ON" button and keep pressing over than 3 seconds. After that, connect the electrical cords of the equipment that is going to be used such as computer or monitor with the outlets on the rear panel of Inverter. Don't overload the machine with all the equipment used. The buzzer will beep continuously to indicate overload status. Inverter will shut down automatically to protect the machine. CAUTION: Never connect a laser printer or plotter to the Inverter with other computer equipment. A laser printer or plotter periodically draws significantly more power than when its idle status, and may overload the Inverter. 3.2 Switch off By pressing and holding OFF button until the BACK UP LED off. 3.3 Silence When Inverter is under BACKUP mode, press ON button more than 1 second to silence the audible alarm. (The function is disable when Inverter is under condition of LOW BATTERY or OVERLOAD ) 3.4 Auto-detect Once the unit is turned on and keep working. System will detect the itself alwayse. 6

4. ALARM 4.1 BACKUP (slow alarm) When the Inverter is working under BACKUP mode, the Inverter would emit audible alarm. The alarm stops when the Inverter is return to MUTE mode operation.. Attention: The alarm of BACKUP is going to beep every four seconds. (Slow-speed beep). Attention: The Inverter provides mute function for the warning. When the beeping sound occurs, press "ON" to stop it; and press "ON" again to regain the sound. 4.2 LOW DC voltage (rapid alarm) In the BACKUP mode, when the energy of battery becomes to lower level. (about 20%~30%) The beeps rapidly until the Inverter shuts down from DC power failure. Attention: The alarm of DC voltage batteries caused by low voltage beeps every second. (Fast-speed beep). Attention: The rapid alarm under LOW BATTERY condition can't be erased. 4.3 FAULT (continuous alarm) Here is listing some FAULT conditions as following for reference. 5. SOFTWARE OPTIONS AND COMPUTER INTERFACE PORT 5.1 Power Monitoring Software The UPS-MON series software (or other power monitoring software) is applied standard RS-232 interface to perform monitoring functions, and then provides an orderly shutdown of a computer in the event of power failure. Moreover, UPS-MON displays all the diagnostic symptoms on monitor, such as Voltage, Frequency, Battery level and so on. The software is available for DOS, Windows 3.1x, Windows 95/98/2000, Windows NT V3.5/4.0 or later, Novell Netware and others. Call your dealer for more information on computer OS compatible solutions. 5.2 Interface Kits A series of interface kits is available for operation systems that provide UPS monitoring. Each interface kit includes the special interface cable required to convert status signals from the UPS into signals which individual operating system recognize. The interface cable at UPS side must be connected to REMOTE PORT, at computer side can be either COM 1 or COM 2. The other installation instructions and powerful features please refer to READ.ME file. CAUTION: Use only factory supplied or authorized UPS monitoring cable! 5.3 The characteristics of computer interface port The computer interface port has the following characteristics: The communication port on the back of the UPS may be connected to host computer. This port allows the computer to monitor the status of the UPS and control the operation of the UPS in some cases. Its major functions normally include some or all of the following: To broadcast a warning when power fails. To close any open file before the battery is exhausted. To turn-off the UPS. Some computers are equipped with a special connector to link with the communication port. In addition, special plug-in cord may be needed. Some computers may need special UPS monitoring software. Contact your dealer for the details on the various interface Kits. 7

5.4 The pin of computer interface port The pin of computer interface port has the following characteristics: 5.4.1. Pin 5 and 2 are open collector outputs that must be pulled up to a common referenced supply no greater than DC +40V. The transistors are capable of a maximum nonconductive load of DC 50 ma, Use only pin 7 as the common. 5.4.2. Pin 5 generates a High to Low signal when the battery inside the UPS has less than 5 minutes back up time left. 5.4.3. Pin 2 generates a High to Low signal when the line is fail. 5.4.4. The UPS will shut down when a high RS-232 level is sustained on pin 6 for 0.36 seconds. 5.4.5. Pin 9 is also the RS-232 data output. 5.4.6. Pin 6 is RS-232 data input (RxD) NOTE: 1. Switch rating +40V, 0.15A non-inductive. 2. Pin 7 should be connected to ground only. Communicating Interface Port We provide a standard RS232 line (that is compatible with DB9 line) socket on the rear panel of UPS. That port possesses several signals as explained below: Pin# Function Explanation I/O 2 Power Fail-normally open status, will become closed during active OUTPUT 4 Reference GND for pin2,5 OUTPUT 5 Battery Low- normally open status, will become closed during OUTPUT active 6 Remote shutdown UPS-keep this pin at high voltage(+5v~+12v) INPUT 500ms to shutdown UPS. Activates at battery mode 7 Reference GND for pin6 INPUT 8

APPENDIX A TROUBLESHOOTING Problems Possible Reasons Solutions Inverter can't DC Input power is not Contact the dealer or service center for help operate after pressing On/Off correct Input fuse open Change the input fuse (in side) switches Time of pressing the ON Keep pressing the ON button over 3 seconds button is too short Output short circuit or overload on Inverter Turn off the inverter, and take off all loads to make sure there are no problems on it. Turn on the unit again. Unit damaged. Contact the dealer or service center for help System cannot work under DC mode. Input power cord is disconnected. Plug-in the power cord and turn on the unit again. No input power Check the input power. Unit damaged Contact the dealer or service center for help Working time under Batteries are not fully Keep charging more than 24 hours. If the backup mode is not charged. problem is still the same, contact the dealer match with the Batteries are damaged. or service center for help. specification. Charger is damaged Contact the dealer or service center for help Screen of Problem caused by Contact the dealer or service center for help connected TV/Monitor. TV/Monitor is TV/Monitor is not Adjust the TV/Monitor correctly. shaking. adjusted correct. TV/Monitor is influenced Adjust the location of relevant appliances and by other appliances. For keep the influence far away. example: mobile phone. Buzzer keeps Overload Take off some loads beeping 9

APPENDIX B SPECIFICATIONS Tower model INV-1500-LCD/ INV-1500-LED 19" rack-mount NV-1500-LCD RM/ INV-1500-LED RM Power rating P.F.=0.7 1.5KVA/ 1050W DC Input Dc Voltage +/- 48VDC Dc Voltage range +/- 34~ 60VDC AC output Waveform Pure Sine-wave Frequency 50Hz or 60Hz (Option) Voltage 100/110/115/120V or 200/208/220/230/240V Voltage regulation +/- 2% Frequency stability +/- 0.5% Power factor 0.7 (lagging) Harmonic distortion <3% of T.H.D. at linear load Overload detection >105% for 10 seconds, >130%+/-10% for 300ms Crest factor ratio 3:1 Efficiency PROTECTION DC to AC Inside Protection >85% Overload protection Over temperature protection Short circuit protection Input DC voltage limit protection Noise level 1m. distance <45dBA LCD Display Status Indicate inv, backup, fault, bat capacity, load (For INV-1500-LCD capacity, O/P voltage, inside temperature, fault INV-1500-LCD RM) status LCD Display Status Inverter output (green), fault (red) (For INV-1500-LCD Battery capacity 4 green, 1 red LED and bar LEDs indicates low INV-1500-LCD RM) capacity Load level 4 green, 1 red LED and bar LEDs indicates overload capacity Alarm Input DC voltage The first warning will beep every 4 seconds to indicate battery in use. The second warning will beep every 1 second to signal battery low condition ENVIRONMENT Temperature 0-40 Humidity 0-95 (Non- condensing) Physical size Tower model 145x400x220(5.7"x15.7"x8.7") WxDxH(mm) 19 rack-mount 430x400x130(16.9"x15.7"x5.1") Net weight Tower model 18 (39.7lb) (kgs) 19 rack-mount 25 (55.1lb) 2002.05.22 Version 3.0 All right Reserved. All trademarks are property of their respective owners. Specifications subject to change without prior notice. 10