MULTISTIM FRACTURE ISOLATION SYSTEM

Similar documents
Fiber Optics in a Bakken Multi-Stage Fractured Well. Montana Tech 2011 SPE Drilling Symposium Presented by: Chelsea Kadler

WELL COMMANDER Versatile multi-cycle ball-activated drilling valve for mitigating downhole hazards

Foam Wiping Technology

Rigorous Qualification and Development Program

Drilling Problems. pull

Casing Wiper Plugs and Darts

Drill String Design. The following topics will be discussed

Fishing Jar. Fishing Jar Accessory Tools. Assembly and Operation. Construction. Recommended Spares

DIRECT PUSH DRILLING.

10 Wireline operations

TECHNICAL PUBLICATION

NORSOK Standard D-010 Rev. 4, August 2012

C O M P L E T I O N S E R V I C E S

Subsea Drilling Systems

Fit-for-Purpose Casing, Cementing, and Completion Solutions PRODUCT CATALOG

Plug and Abandonment Forum

Varel International Workover Bits for remedial, re-entry AND frac plug Drilling Applications

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Lenntech psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503

ELLIOTT COLLET STYLE Baffle Expander With Hydraulic Power Supply

Argentina Tataru*, Marcel Adrian Piteiu*, Dan-Paul Stefanescu*, Ioana Vlasin*

Positive Displacement Motors (PDM)

M A N U A L

Product catalogue, pipe and sewer cleaning systems

Advancing Reservoir Performance. Wellbore Cleanup Tools and Displacement Chemicals

Stainless Steel Single and Dual Circulation Kits

Introduction. The following is an outline of the contents of this paper: Definition of Artificial Lift Page 2. How an Oil Well is Produced Page 2

An Introduction to Oil and Gas Well Servicing

UNIT CONVERSIONS & FORMULAS

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

Unit 24: Applications of Pneumatics and Hydraulics

The Impact Of Cementing On Proper Well Control

Solving challenges. Drill out solutions Package

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES


Well control equipment. Matanović Davorin, professor

Green Thread Product Data

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Submersion/Insertion Toroidal Sensor

Step-by-step instructions:

FIBER-OPTIC SENSING TECHNOLOGIES

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

PVH131/141 Variable Displacement Piston Pump - 11 Design

SELECTION, APPLICATION & MAINTENANCE

Vrtné trubky Drill Pipe

BERMAD Fire Protection

Specification for Rotary Drill Stem Elements

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE

LINEAR MOTION CONTROL

BERMAD Fire Protection

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Stainless Steel Valves For the Sanitary Industries

Wireline Tool String. A standard set of wireline tool string typically consist of:

Hydraulic Jack Units. Contact Us! EECO (3326) Delivery & Lead Times

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

Wellbore Integrity Restoration Services

Unit 24: Applications of Pneumatics and Hydraulics

Unit: mm(in) Item Standard value Service limit Axle shaft run out - 0.2(0.008)

Operating, Installation, and Maintenance Instructions

Introduction to Subsea Production System

HPHT CAPPING STACKS AND NEW TECHNOLOGY FOR SUBSEA WELL CONTROL. December 3, 2014 Presenter: Mike Cargol

Parker Subsea Drilling. BOP Umbilicals, Hotlines and Stack Hoses

System Saver 318 Air Compressor for Mack E-Tech and ASET Engines

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

Spicer Axles & Brakes ABIB-0302

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

SAFETY SAFETY APPAREL 20,000 PSI

2100 AD Mirror Elevator Ball Nut Replacement Procedure

This instruction is valid for all ACD pump models shown on page 2

Hydraulic Fracturing Operations Well Construction and Integrity Guidelines API GUIDANCE DOCUMENT HF1 FIRST EDITION, OCTOBER 2009

BOWIE PUMPS OPERATION - MAINTENANCE

CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST

Tax Executives Institute

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

BOP PRESSURE TESTING PROCEDURE

TRANSLATION OF THE ORIGINAL MANUAL

Fire Hydrant Troubleshooting

product manual HS-4210 HS-4210_MAN_09.08 Digital Static Cone Penetrometer

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Setting a Global Standard. SS Series Subsea Wellhead Systems

Mechanical Seal Piping Plans

SIMPLAIR PIPING TOOL

Setting a Global Standard. SingleBore Subsea Completion System

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

INDEX INTRODUCTION. Reference No L-01 R E V I S E D :

Oil and Coolant Circulating Heating System. Model - OCSM

Arctic Leash Instruction Manual Alaskan Products Company LLC.

POWERS Controls No. 4 Pneumatic Damper Actuator

This Addendum supplements and clarifies the contents of Service Bulletin SB

Rotary Vertical Drilling System (RVDS)

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

COMPARISON OF DRILLING TECHNOLOGIES BETWEEN TOP DRIVE AND ROTARY TABLE IN GEOTHERMAL FIELDS: A CASE STUDY OF OLKARIA GEOTHERMAL FIELDS.

COMPLETION SOLUTIONS 1

SPE/IADC WELL CONTROL ASIA PACIFIC 2009 Velocity string installation in deep live gas wells.

Energize your mind. April Lightweight Cement Meets Challenges of Weak Formations and Depleted Zones

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

API Std 53 - Blowout Prevention Equipment Systems for Drilling Wells Last update: August 12, 2015

16 April F Dodge Adjustable Track bar with Relocation Bracket 1

Perforating Basics. How the perforating processes work. George E. King Engineering GEKEngineering.com 3/14/2009 1

Transcription:

MULTISTIM FRACTURE ISOLATION SYSTEM

MULTISTIM FRACTURE ISOLATION SYSTEM Frac isolation liner and tie back string deployable in a single trip Dual & Single Element Hydro mechanical open hole packers Custom Swellable Packers available Control sand and water issues with selective shiftable frac sleeves Full bore ID clean out allows for easy access during refrac Male Receptacle 3J SEAL ASSEMBLY Female Receptacle LINER TOP PACKER 5.90" DUAL ELEMENT OPEN HOLE PACKER 5.90" OPEN HOLE PACKER 4.50" DAS FRAC VALVE 5.90" OPEN HOLE PACKER 4.50" HYDRAULIC PORT VALVE 4.50" FLOW LOCK COLLAR Frac Stages #2-30 Frac Stage #1 Make it an open and shut case with Logan Completion's MultiStim Fracture Isolation System www.loganinternationalinc.com (403) 930-6810

MultiStim 6.080" Open Hole Reamer The MultiStim 6.080 Open Hole Reamer is an essential component to the successful installation of the MultiStim Fracture Isolation System. The 6.080 Open Hole Reamer is run immediately prior to the liner installation to ensure clean installation of the liner without the need for circulation and/or rotation. The 6.080 Open Hole Reamer effectively builds a smooth transition in the wellbore by evening out dog legs and tight spots. HELIX DESIGN The 6.080" Open Hole Reamer features two sets of three-bladed lefthand helixes. The first helix has a 120 offset and the second has a 180 degree offset. EXTENDED-LIFE CUTTING SURFACE The two-inch-wide helix blades are dressed with tungsten carbide shard matrix. This matrix continually exposes new carbide shards as the blades wear to maintain an effective cutting surface. The MultiStim 6.080" Open Hole Reamer and MultiStim Fracturing Isolation System components are designed and manufactured to API Q1 standards at our certified manufacturing facility. Dim (in) (mm) A 4.75 120.65 B NC 38 C 17.30 438.20 D 11.50 292.10 E 37.30 946.20 F 66.30 1684.10 G 70.20 1784.10 H 6.08 154.43 J 2.70 68.58 K NC 38 TOOL RATINGS Rating Value 596,000 lbs 265,100 dan Torque 20,879 ft-lbs 28,300 N-m MultiStim 3J Seal Assembly and Receptacle Simple Design and Operation Full Bore Inside Diameter 3J Seal Assembly is used as the Liner Running Tool and Tie Back Seal Chevron Seal Design rated at 300 F and 10,000 psi 2 tieback lengths available: o 5 (*1.52m) Seal Assembly o 10 (3.0m) Seal Assembly. The 3J Running Tool is composed of two robust components; the 3J seal assembly and the 3J receptacle. The retrievablereusable 3J seal assembly features external high load rated lugs and high performance V-seal assembly for elevated bottom hole temperatures and multiple fluids compatibility. The 3J receptacle is a one piece design to facilitate high torque, tensile and pressure ratings. The 3J receptacle incorporates a stab-in guide, internal jslot and polished seal bore. SIMPLE DESIGN The 3J Running Tool is designed for ease of down hole operation. The 3J Running Tool is designed to enable rotation during the liner installation. Once the liner has been installed, open hole packers and liner hanger packer have been set and tested, simply apply compression to the run-in string, apply ¼ right hand turn and pick up to disconnect. A tie-back fracturing string can be reconnected with a straight stab-in 3J Receptacle with the 3J Seal Assembly. FULL BORE DESIGN The minimum ID through the 3J Running Tool is equal to the minimum liner casing. All MultiStim Fracture Isolation System s components are designed and manufactured to API Q1 standards at our certified manufacturing facility. (8RL) Max O.D. (psikpa) 4-1/2 4.500 6.00 125,000 10,000 114.30 4.500 152.40 55,600 68,950

MultiStim PermaPak Liner Top Packer Works in conjunction with 3J Seal Bore Receptacle Full bore design No special setting tools required The MultiStim PermaPak Hydraulic Packer is a large seal bore packer. The hydraulic setting chamber is built into the packer; there is no need for additional setting tools in the string. SIMPLE OPERATIONS enters the setting chamber via holes in the internal mandrel of the packer. When the frac liner is spaced out in the proper location of the well, a ball is dropped to start the setting activation process. The ball lands in the Flow Lock Sub sealing off communication from tubing to annulus. is increased until the initial setting process starts (1,376 psi). The packer is completely set with 3,500 psi. Packer Weight (lbs/ft - kg/m) Recommended Hole Tool OD Seal Bore Area (in²/cm²) Initiation Min Max 4.0 x 7.0 23-32 6.094-6.366 5.875 4.00 5.809 1.375 3,500 4,500 101.60x177.80 34.2-47.6 154.79-161.70 149.23 101.60 37.48 9.48 24.13 31.02 MultiStim MegaSeal Open Hole Packer Dual-Element Design Hydraulic Selective Exceeds API Q1 Standards The MultiStim MegaSeal Open Hole Packer is used to straddle the Drill-a-Seat (DAS) Valve for fracture zone isolation. Any number of packers may be installed for any open hole isolation application. PERFORMANCE DUAL-ELEMENT DESIGN The MegaSeal Open Hole Packer increases open isolation performance with a recessed dual packing element design. The recessed packing element run in diameter reduces potential damage during installation. The dual-element system creates a dual barrier in the open hole to ensure zonal isolation. HYDRAULIC SETTING Hydraulic setting enables well fluid circulation and well displacement without risk of premature packer setting. SELECTIVE SETTING The complete liner isolation string of packers can all be set with a single pressure cycle or can be set at staged pressure cycles if desired. The MultiStim MegaSeal Open Hole Packer is designed with performance specifications that equal the liner casing. MultiStim Fracturing Isolation System components are designed and manufactured to API Q1 standards at our certified manufacturing facility. (8BL) O.D. Activation Burst Collapse (psikpa) 4-1/2 4.500 8RL 5.80 1,425 1,575 250,000 9,000 5,750 114.30 4.500 8RL 139.7 9,825 10,850 111,200 73,800 39,640

MultiStim DAS Frac Sleeve Full bore access after seats are milled Selective Isolation Selective Refracturing Shiftable Fully Open/Close The Drill-a-Seat (DAS) valve is ball-activated The Drill-a-Seat (DAS) valve is a ball-activated sleeve used to divert fluids to a defined interval of a wellbore. The valves can be utilized in vertical or horizontal wellbore as a liner monobore system in an open-hole application. Multiple valves can be installed in a well design and the seat sizing can be set up to meet the ID desired. The activation balls are launched from the surface and travel with the fluid to land on the appropriate seat. Once the ball has seated, the area below the DAS is isolated, and applied pressure will shift the ball, the seat, and the inner sleeve into the open position. The wellbore stimulation process can now be initiated, and the fluid will be diverted through the now open side ports.the opening pressure of the DAS is adjustable, and can be set up to adhere to the needs of the well program. Upon completion of the well program, cleanup of the well can be completed and the activation balls can be flowed back into a downhole ball catch sub, or the balls can be flowed back to the surface. The balls and seats can also be milled out to return the wellbore to a uniform inner diameter. The DAS has a unique feature, in that once the well program has been completed and the seats have been milled out, the shiftable sleeve is able to be repositioned back into the fully closed state, isolating the once open ports. This can be completed early on in the life of the well, or at a later date, should zonal isolation be required for production. Tool OD Mill - Out ID Mill OD Shear Pins (10 max) Material Flow Area 4-1/2 in 5.420 in 3.875 in 3.920 in 268 psi/ea P-110 20 in² 114.3 mm 137.67 mm 98.43 mm 99.570 mm 1.85 mpa/ea P-110 20 cm² MultiStim DAS Frac Sleeve Ball Seat Guide 4-1/2" 11.6-13.5 ppf 114.3mm 17.3-20.1 kg/m Description Frac Sub # Ball Seat ID Ball OD Flow Lock Collar 0.740 0.800 Hydraulic Port Valve 1 Actuated - No Ball 2 0.815 0.900 3 0.915 1.000 4 1.015 1.100 5 1.115 1.200 6 1.215 1.300 7 1.315 1.400 8 1.415 1.500 9 1.515 1.600 10 1.615 1.700 11 1.715 1.800 12 1.815 1.900 13 1.915 2.000 14 2.015 2.100 Frac Valves 15 2.115 2.200 16 2.215 2.300 17 2.315 2.400 18 2.415 2.500 19 2.515 2.600 20 2.615 2.700 21 2.715 2.800 22 2.815 2.900 23 2.915 3.000 24 3.015 3.100 25 3.115 3.200 26 3.215 3.300 27 3.315 3.400 28 3.415 3.525 29 3.540 3.655 30 3.670 3.790 Weight Thread Burst Collapse 4-1/2 in 11.6 lbs/ft Optional 278,000 lbs 10,690 psi 7,580 psi 4-1/2 in 13.5 lbs/ft Optional 337,000 lbs 12,410 psi 10,690 psi 114.3 mm 17.3 kg/m Optional 624971 dan 73.71 mpa 52.30 mpa 114.3 mm 20.1 kg/m Optional 757609 dan 85.57 mpa 73.71 mpa Logan Dissolvable Balls: Customizable Dissolvable balls, Reservoir specific. Eliminates the need for drilling out seats and lodged balls on seat.

MultiStim Hydraulic Port Valve The MultiStim Hydraulic Port Valve is strategically placed as the toe or first frac zone port when used in the ball actuated Drill-A- Seat (DAS valve system. Multiple valves can also be used in a non-ball hydraulic actuated frac port system in conjunction with the MultiStim Cup Frac Tool System. FULL BORE INSIDE DIAMETER Shifting components eliminate any ID reduction and any drill out requirements to gain lower access of the liner. ADJUSTABLE ACTUATION PRESSURE The hydraulic opening pressure can be adjusted prior to installation. PERMANENTLY LOCKS OPEN Once actuated, the valve is permanently locked open. EXCEEDS DESIGN AND MANUFACTURING STANDARDS The MultiStim Hydraulic Port Valve is designed with performance specifications exceeding that of the liner casing. MultiStim Fracturing Isolation System components are designed and manufactured to API Q1 standards at our certified manufacturing facility. (8RL) Max O.D. Collapse Activation Burst 4-1/2 4.500 5.50 269,000 5,000 2,850-3,150 5,000 114.30 4.500 139.70 120,100 34,500 19,650 20,685 34,500 MultiStim Flow Lock Collar The MultiStim Flow Lock Collar is lowermost component above the liner shoe track. The Flow Lock Collar allows well fluid to fill up during liner installation. Circulation for well fluid displacement once the line is at depth and when closed, provides liner pressure integrity for setting of the MegaSeal Open Hole Packers, the liner hanger packer and opening of the MultiStim Hydraulic Port Valve. BALL ACTUATED The Flow Lock Collar remains open for circulation until the corresponding ball is circulated to the collar. ADJUSTABLE ACTUATION PRESSURE The hydraulic closing pressure can be adjusted prior to installation. LOCKING SHUT OFF Once the Flow Lock Collar has been shifted closed, it remains permanently locked. The MultiStim Flow Lock Collar is designed with performance specifications equal to that of the liner casing. The MultiStim Flow Lock Collar and all components are designed to API Q1 standards at our certified manufacturing facility. (8RL) Max O.D. Collapse Activation Burst 4-1/2 4.500 5.00 123,100 7,580 900 1000 10,6900 114.30 4.500 127.00 54,760 52,260 6,205 6,900 73,705

MultiStim Bi-Directional Hydraulic Shifting Tool Shifts Valves to Open or Closed Position Flow Actuated No Drop Balls Needed Self Draining No Wet Strings Compatible With Threaded or Coiled Tubing The MultiStim Bi-Directional Hydraulic Shifting Tool is able to open or close any number of valves in a single trip. It works with threaded or coiled tubing and is compatible with or without jars or bumper subs. The tool is easy to locate with Logan Completion Systems Mechanical Collar Locator. SHIFTS VALVES OPEN OR CLOSED The MultiStim Bi-Directional Shifting Tool is used to shift the internal piston sleeve of the MultiStim Drill-a-Seat (DAS) Valve to either the open or closed position. Individual or multiple valves can be repeatedly opened or closed in a single trip. The MultiStim Bi-Directional Shifting Tool works with threaded or coiled tubing. When used in conjunction with the Logan Completion Systems Mechanical Collar Locator, the need for complicated space out calculations is eliminated. FLOW ACTUATED The MultiStim Bi-Directional Shifting Tool is a flow-actuated tool that can be cycled repeatedly downhole without affecting the reservoir characteristics and with activation pressures less than the frac gradient. SELF DRAINING The MultiStim Bi-Directional Shifting Tool is designed to fail safe with the slips in the retracted position. However, should there be the need, there is a secondary release mechanism. To activate the secondary release mechanism, a ball is pumped down to an internal seat, pressure is applied to the string bursting a rupture disk. This will release any internal pressure that could be trapped in the tool and retract the slip mechanism. MultiStim Bi-Directional Hydraulic Shifting Tool and MultiStim Fracturing Isolation System components are designed and manufactured to API Q1 standards at our certified manufacturing facility. Max Free Flow Rate Activation Flow Rate Max Pull/ Push Contingency Ball Ball Drop Contingency Contingency Flow Rate (lbs) 4-1/2 3 bbl/min 5 6 bbl/min 100,000 lbs Ø 0.88 in 4,000 psi 7 bbl/min 128,000 lbs 4-1/2 0.477 m3/min 0.795 0.954 m3/min 44,480 dan 22.35 mm 22,579 kpa 1.11 m3/min 56,937 dan MultiStim Cement Seal Liner Top Packer Works in conjunction with 3J Seal Bore Receptacle Full bore design No special setting tools required Dual stage hydraulic release & set Stage Tool/Debris Sub compatible Anti-Preset mechanism Top & Bottom Slips The MultiStim Cement Seal Liner Top Packer is a large seal bore packer. The hydraulic setting chamber is built into the packer. There is no need for additional setting tools in the string. Run in conjunction with the Logan 3J Running Tool, which provides a 10,000psi/69MPA pressure rated Tie-Back. The Cement Seal Packer can also be run with a Stage Tool & Debris sub below the Packer. Once the cement job is complete the user can release from the liner top seal receptacle with a ¼ turn. Tie- Back frac string can be run with a straight sting in/mechanical release, or straight sting in/sting out. Packer Weight (lbs/ft - kg/m) Recommended Hole Tool OD Seal Bore Area (in²/cm²) Initiation Min Max 4.0 x 7.0 23-32 6.094-6.366 5.875 4.00 5.809 1.375 3,500 4,500 101.60x177.80 34.2-47.6 154.79-161.70 149.23 101.60 37.48 9.48 24.13 31.02 www.loganinternationalinc.com (403) 930-6810 2015 Logan International Inc. All rights reserved. PDS/CAPS/MSF Iso Syst 06-10