TB82 Conductivity transmitters 2-Wire. Loop-powered transmitters that reduce installation costs in hazardous areas

Similar documents
AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Rosemount 333 HART Tri-Loop

TB2CS Conductivity sensor 2-Electrode. Superior accuracy in low level conductivity measurement ranges

Rosemount 333 HART Tri-Loop

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

Technical Information RIA14

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Electronic Control Devices The European Product Catalogue 2007

Regards from the Team at Rheology Solutions.

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

3DLevelScanner II TECHNICAL DATA SHEET

3500/93 System Display

Actuators & Positioners LP - Linear Pneumatic Piston Actuator. Cylinder Actuators. High resolution, sensitivity, and fast response

Digital inductive conductivity transmitter

3500/62 Process Variable Monitor

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

CalMaster2 Field and Software Tools. The world's first battery- and mains-powered in situ flow verification system

TEIP11 I/P signal converter for standard signals. Measurement made easy

STB Series Enclosures

Microcor Wireless Transmitter (MWT)

Testomat AW101 Water Hardness Monitor. A unique water hardness monitoring system with superior performance

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Electronic Control Devices The European Product Catalogue 2007

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

Toroidal Conductivity Sensor

Analog signal converters CC-E I/I Current / current isolators

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Unidirectional Transmitter/ Receiver Units Introduction

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

EBS852 (Contrac) Power Electronic Unit

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

STX2100. Differential Pressure (Flow) Transmitter. GE Measurement & Control. Models FKC...5. Features

Technical Data Sheet. 3DLevelScanner

TWO-WIRE TRANSMITTERS FOR ph, ORP, CONDUCTIVITY, OXYGEN, OZONE, AND CHLORINE

PRODUCT PROFILE FEATURES

1701/22 FieldMonitor Management Interface Module

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Use A Ds340 (Dsp)

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Repeaters and Mimics Data Sheet

SEISMIC VELOCITY TRANSDUCER T1-40

Floodlight Range Installation Guide

Model: DC-A2IO Advanced HVAC Controller

S-series SQ Controller

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

T0118 T2118 T3118. Instruction Manual

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Analytical Instruments Smart Analyzer 90 Type SMA

Rosemount 751 Field Signal Indicator

ALARMLINE ANALOGUE Linear Heat Detection System

Navigator 600 Phosphate Phosphate analyzer. Cost-effective automated monitoring of phosphate for steam raising applications

For Multi-Parameter Meters see mvx

FIREDEX Conventional Fire Panels

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

Siemens AG Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.

OZW30. Central Unit SYNERGYR

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Electromagnetic Flowmeter

3500/25 Enhanced Keyphasor*Module

Product Specification instalert Rapid Messenger Variable Message Sign

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

2.12. page Products for Explosion hazardous Environment

Model 3051 Pressure Transmitter with HART Protocol

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

Wireless Gauge and Absolute Pressure Transmitters Series XYR 5000, Model WG5xx/WA5xx Specifications - Americas

Service catalog Flow products

The L&J Engineering Model MCG 1500SFI Servo Gauge

COMBIMASS. Technical Data COMBIMASS eco-bio +

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Process gas chromatographs. Measurement made easy. Compliance Solutions for 40CFR60 Subpart Ja

Instruction Manual LIQ-MAN-5081P/rev.J January Model 5081-P. Two-Wire ph/orp Transmitter

FGM 160 ATEX EC type examination certificate

S-series Mass Connection Solutions

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Quick Start Guide , Rev DA March Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator

Duct Humidity Transmitter

Three-phase monitoring relay CM-PFE

MINIMAT-EC-Servo Screwdriver Spindles

Voltage Regulator SPAU 341 C. Product Guide

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

DC Electronic Loads 8500 series

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

M-series FOUNDATION Fieldbus I/O

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

S300 Series Dust Monitors

Transcription:

Data sheet DS/TB82-EN Rev. G TB82 Conductivity transmitters 2-Wire Loop-powered transmitters that reduce installation costs in hazardous areas Intuitive user interface Easy to use menus guide the operator through set-up, calibration and maintenance Full range of conductivity sensors Make measurements in ultra-pure or high conductivity applications Advanced Digital Communications Available with PROFIBUS PA, FOUNDATION Fieldbus or HART communications Large, Easy-to-Read Display Shows primary measurement along with user-selectable secondary display (temperature, output current or sensor input) Programmable Security Codes Prevents unauthorized modifications to transmitter configuration and calibration Intrinsically Safe, Non-incendive Design Permits use in hazardous areas Hazardous area transmitters Withstand the harshest environments NEMA 4X / IP65 housings

General Description The ABB TB82 Series of two-wire conductivity transmitters are available in three base configurations to utilize ABB s two-electrode, four-electrode or toroidal (electrodeless) sensors, allowing for installations ranging from ultra-pure water to the most difficult chemical applications. The TB82 Series is available with traditional programmable outputs or with advanced digital communications utilizing FOUNDATION Fieldbus (FF), PROFIBUS PA (PA) or HART. Setup, maintenance and operation in the field is simple. Easy to follow instructions appear above each Smart Key. The user-friendly interface provides for straightforward transmitter configuration and calibration. A unique secondary display clearly defines each menu option when programming the transmitters. During normal operation, the secondary display may be configured to show process temperature, current output, concentration type, raw conductivity or software revision depending upon configuration. The TB82 series transmitters meet current CE, NEMA 4X, IP65, CSA, FM, ATEX and FISCO requirements. Sensor Compatibility and Ranges Sensor compatibility is determined by the TB82 model number. The TB82 Series is available in three base configurations. The TB82TE connects to ABB 2-electrode sensors, TB82EC to ABB 4-electrode sensors, and TB82TC to ABB toroidal sensors. A menu choice during programming makes changing from one cell constant or sensor group simple; no jumpers or manual adjustments required. Temperature Compensation The TB82 is compatible with a variety of automatic temperature compensation elements. See Specification section. Programmable Security Code The transmitter has a three-digit security code to prevent unauthorized modifications that may be applied to any combination of the following menus: Calibration, Output/Hold, Security, and Configure. Basic or Advanced Programming Modes (FOUNDATION Fieldbus, PROFIBUS PA models and HART available in Advanced mode only) Available with either Basic or Advanced programming modes at time of purchase, the Advanced mode offers an expanded feature set for more complex operations, such as: Nonlinear and concentration analyzer modes Advance temperature compensation modes Analog pulse diagnostic output Impresses a user-defined 0.16 to 16 ma pulse on the 4 to 20 ma output to alert operator of a fault condition. (Not available on transmitters with digital communication.) 2

Diagnostics The transmitter constantly monitors both itself and the sensor to ensure reliability and accuracy. Upon detection of a diagnostic condition, the transmitter provides diagnostic notification by flashing FAULT on the display and supplying a pulse on the analog output (if activated on non-hart devices). Transmitters equipped with Foundation Fieldbus or PROFIBUS PA send a complete diagnostic description over the network to the controller. This allows for easy, immediate troubleshooting. Pressing FAULT info on the transmitter provides a short description and fault codes on the secondary display. The FAULT icon remains active until problem has been resolved. Adjustable Damping Damping is helpful in process environments where noise is present. It is a capacitive type lag where reaction to any signal change is slowed according to the entered time constant. For example, the response to a step input change reaches approximately 63 percent of its final value in five seconds for five seconds of damping. Communications FOUNDATION Fieldbus (FF) addresses modern instrument users needs for flexibility and cost savings, while providing a whole host of additional features. Measurement variable quality and diagnostic conditions transmitted during each scheduled data transfer Easily configured remotely or locally Transmission of multiple process variables utilizes two Analog Input Blocks (AI) Transmitter characteristics such as device name, manufacturer and serial number via a Standard Resource Block Configuration and calibration capability via custom Enhanced Transducer Block Provides calibration Methods on supported host tools and systems PROFIBUS PA (PA) is a standardized, open, digital communications system for process automation. Configuration, calibration and trending available via a Device Type Manager (DTM) when used on compatible host tools and systems Measurement variable quality and diagnostic conditions transmitted during each scheduled data transfer Remote and local configuration capability Choice of Standard Analyzer Profile or Manufacturer Specific Profile conforms to PROFIBUS PA Profile requirements v. 3.0 GSD files available on all product variations Utilizes one Physical, one Transducer, and two 3

HART communications protocol provide remote programming via any HART compatible primary or secondary communications device. Digital communications through a low-level modulation superimposed on the standard 4-to-20 ma current loop Accommodates Universal, Common Practice and Device Specific Command Sets for functionality within HART networks and for use with HART hand-held terminals Driver files for various host systems and tools available Calibration The TB82 features a simple and straightforward one-point or two-point calibration of the primary process variable and temperature. Calibration data may be manually edited. Input Temperature Compensation Types Temperature Display Range -20 to 300 C (-4 to 572 F) Advance Temperature Compensation Modes Specifications Type 2-wire Conductivity Transmitter: 2-Electrode Model TB82TE 4-Electrode Model TB82EC Toroidal Model TB82TC Input Sensor Types TB82TE: ABB 2-electrode sensors TB82EC: ABB 4-electrode sensors TB82TC: ABB toroidal sensors 4

Measurement Ranges 2-Electrode Conductivity - Model (TB82TE) Cell Constant 4-Electrode Conductivity - Model TB82EC Sensor Group A Accuracy Display: Measurement Range Output: Temperature: 1 C or 1 F Repeatability Display: Display Resolution 0 to 1999 ms/cm 0. 1 B 0 to 1999 0.01 Toroidal Conductivity - Model TB82TC Sensor Group Toroidal Measurement Range Measurement Range Display Resolution 0 to 1999 ms/cm 0. 1 Display Resolution Output: Temperature: 1 C to 1 F Auto-range 0 to 199.9, 0 to 1,999 0 to 19.99 ms/cm, 0 to 199.9 ms/cm 0 to 1,999 ms/cm 0 to 19.9, 0 to 199. 9 0 to 1,999 Auto-range 0 to 199.9, 0 to 1,999 0 to 19.99 ms/cm, 0 to 199.9 ms/cm 0 to 1,999 ms/cm +/-0.5% of measurement range per decade (TB82EC,TC) +/-1.0% of measurement range per decade (TB82TE) +/-0.02 ma +/-0.5% of measurement range per decade( TB82EC & TC) +/-1.0% of measurement range per decade (TB82TE) +/-0.02 ma Stability Display: +/-2 LSD typical, +/-5 LSD max Output: +/-0.01 ma Temperature: 1 C or 1 F Output Isolated 4-20 ma, Linear and Non-linear (non-fieldbus models) Auto-range 0 to 1.999 0.01 0 to 199. 9 0.001 0 to 19.99 0 to 199.9 0.10 0 to 1999 0.01 1.00 0 to 19.99 ms/cm 0. 1 0 to 19.99 0 to 199.9 0 to 1,999 0 to 199.9 0 to 1,999 0 to 19.99 ms/cm Output Minimum Span Concentration: 5% of maximum configured concentration Output Maximim Span (Full scale settings) Concentration: 1999 digits Damping Adjustable: 0.0 to 99.9 seconds Environmental (Temperature) Operating: -20 to 60 C (-4 to 140 F) LCD: -20 to 60 C (-4 to 140 F) Storage: -40 to 70 C (-40 to 158 F) Humidity: up to 95% RH Enclosure NEMA 4X and IP65, anodized aluminum alloy with polyester powder coating Size (1/2 DIN) H x W x D: 144.0 x 144.0 x 171.0 mm (5.67 x 5.67 x 6.73 in.) Min. panel depths: 144.8 mm (5.70 in.) Max. panel thickness: 9.5 mm (0.38 in.) Panel cutout: 135.4 [+1.3, -0.8] by 135.4 [+1.3, -0.8] mm (5.33 [+0.05, -0.03] by 5.33 [+0.05, -0.03] in.) Weight: 1.9 kg (4.2 lb) 3.4 kg (7.5 lb) with pipe mounting hardware Conduit Connections Two (2) each: 22.2 mm (0.875 in.) holes in enclosure that accepts 1/2 inch hubs Lightning Suppressor Installed integral to the transmitter to suppress lightning induced transients. Tested to suppress 10 successive 8 by 20-μsec pulses with a peak value of 20 ka (reference IEEE C62.41) 5

Power Requirements Standard: HART: 14.0 to 53 VDC (14.0-42 VDC for certified applications) 14 to 53 VDC (14-42 VDC for certified applications). For HART communication, a 250 Ω resistor is required; 19 VDC minimum voltage required. 14 VDC required for liftoff Foundation Fieldbus & PROFIBUS PA bus powered: 9-32 VDC (non-i.s. model) 9-24 VDC (I.S. model) 15 ma quiescent current consumption Agency Certifications ATEX 100A ATEX Category II 1G; EEX ia, Zone 1; Group IIC, T4 when used with appropriate barriers Canadian Standards Association (CSA) Intrinsic safety: Class I, II, III; Division 1; applicable Groups A, B, C, D, E, F and G; when used with appropriate barriers. T3C Non-incendive: Class I, Division 2, Groups A, B, C, and D. Class II, Division 2, Groups E, F and G. Class III, Division 2 Factory Mutual (FM) Intrinsic Safety: Class I, II, III; Division 2; applicable Groups A, B, C, D, E, F and G; when used with appropriate barriers. T3C (Max ambient Temperature: 60 C Non-incendive: Class I, Division 2, Groups A, B, C, and D. Class II, Division 2, Groups F and G. Class III, Division 2. T5 Fieldbus Intrinsically Safe Concept (FISCO) Fieldbus products (FF and PA) meets the requirements for the FISCO model EMC Requirements CE Certified complies with all applicable European Community product requirements, specifically those required to display the CE markings on the product nameplate. 6

Overall Dimensions FRONT SIDE BOTTOM 26.7 1.05 10.2 0.40 143.8 5.66 143.5 5.65 114.0 4.49 143.8 5.66 50.8 2.00 41.9 1.65 DIMENSIONS MILLIMETERS INCHES 14.0 0.55 (4 TYP) 32.8 1.29 (4 TYP) 22.2 DIA 0.88 (2 TYP) T01688C Pipe Mounting Option DIMENSIONS PIPE MOUNT BRACKET LOCKWASHER (4) MILLIMETERS INCHES 12 0.47 FLATWASHER (4) 203 8.00 Pipe 12 0.47 5/16" U-BOLT (2) 5/16" NUT (4) 5/16" X 5/8" LOCKWASHER (4) BOLT (4) 5/16" FLATWASHER (4) Panel Mounting Option PANEL CUTOUT 135.4 +1.3 0.8 5.33 +0.05 0.03 9.5 MAXIMUM PANEL 0.38 THICKNESS PANEL MOUNTING BRACKET (4) PANEL MOUNTING SCREWS (4) 11.9 0.47 135.4 +1.3 0.8 5.33 +0.05 0.03 REAR COVER REMOVED 11.9 0.47 MINIMUM PA NEL DEPTH = 144.8 MM (5.70 IN.) PANEL GASKET EXTERNAL GROUND SCREW PANEL REAR VIEW 3/8-IN. LOCKWASHER (4) 3/8-16 x 1/2-IN. HEX SCREW (4) T01088E 7

Wall (Side) Mounting Option PIPE MOUNT BRACKET FLATWASHER (4) DIMENSIONS MILLIMETERS INCHES FASTENERS FOR WALL (SUPPLIED BY OTHERS) 227 8.94 WALL WALL X 5/8" BOLT (4) LOCKWASHER (4) Wall/Hinge (Rear) Mounting Option TOP VIEW FRONT VIEW FASTENERS FOR WALL (SUPPLIED BY OTHERS) X 3/4" BOLT (8) S.S. HINGE FLATWASHER (4) WALL PIPE MOUNT BRACKET "L" BRACKET NUT (8) FLATWASHER (8) LOCKWASHER (8) X 5/8" BOLT LOCKWASHER (4) Terminal Blocks TB82EC and TB82TE 2-electrode & 4-electrode TB82TC Toroidal (Electrodeless) 8

Base Model T B 8 2 Model TB82 XX X X 1 0 X X X Input Type 2-Electrode 4-Electrode Toroidal (Electrodeless) T E E C T C Programming Option 1 Basic 1 Advanced 2 Digital Communications Option None (Analog Only) 0 HART 1 FOUNDATION Fieldbus 2 PROFIBUS PA 3 Lightning Suppressor Included 1 Housing Type Powder Coated Aluminum 0 Mounting Options None 0 Pipe 1 Wall/Hinge (Rear Mount) 2 Panel 3 Wall (Side Mount) 4 Agency Approvals None 0 FM (Factory Mutual) 1 CSA (Canadian Standards Association) 2 ATEX 100A 3 Tag None 0 Stainless 1 Mylar 2 Accessories: Part Number 4TB9515-0123 4TB9515-0124 4TB9515-0125 4TB9515-0156 Description Panel Mounting Kit Pipe Mounting Kit Hinge Mounting Kit Wall Mounting Kit Product Instruction Manuals: (One copy supplied with instrument at no charge) Notes: 1. Advanced Programming Option must be selected for HART, FOUNDATION Fieldbus or PROFIBUS PA Digital Communication Option 9

TB82EC 4-Electrode Transmitter TB82TC Toroidal Transmitter TB82TE 2-Electrode Transmitter 10

Notes 11

Contact us ABB Inc. Process Automation 843 N Jefferson Street PO Box 831 Lewisburg 24901-9509 USA Tel: +1 800 HELP 365 (435 7365) Fax: +1 304 647 1862 ABB Limited Process Automation Oldends Lane Stonehouse Gloucestershire GL10 3TA UK Tel: +44 1453 826 661 Fax: +44 1453 829 671 Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2015 ABB All rights reserved 3KXA112804R1001 05.2015 ABB Engineering (Shanghai) Ltd. Process Automation No. 5, Lane 369, Chuangye Road 201319, Shanghai, P.R. China Phone: +86 (0) 21 6105 6666 Fax: +86 (0) 21 6105 6992 Mail:china.instrumentation@cn.abb.com www.abb.com