SOFT STARTERS. Easy Selection Guide MOTOR CONTROL AND DRIVES. nhp.com.au

Similar documents
POWER FACTOR CORRECTION

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use:

Energy Monitoring and Control System

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Phone: Fax: Web: info@clrwtr.com

PSR The compact range Description

ESA operator panels & industrial PCs

Products and solutions for lifting systems

Panorama. Softstarters The complete range

Specifying a Variable Frequency Drive s

Products and solutions for pumping, irrigation and piping

Softstarters Type PSR

Products and solutions for machine builders (OEM) 100% electricity

Number 1 in efficiency

Easy to connect - Easy to configure Easy to install

Install the DeviceNet Module using the following procedure:

Iboco Cable Ducting. An integrated system of wiring duct and accessories to suit all applications. TERMINATION & WIRING SYSTEMS

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Franco Vecchiato, SAM LPBS Regional Manager New SACE Emax 2 From Circuit-breaker to Power Manager

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Altistart. 01 Soft Start The starting solution. For single-phase and three-phase asynchronous motors 3 to 85 Amps 1/4 to 75 HP (0.

40.3. Control Relays and Timers

NHP CUBIC Switchboard solutions

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Phone: Fax: Web: info@clrwtr.com

BIG SAVINGS FOR A LOT MORE APPLICATIONS

Frequency Converter Fv

Softstarters. Main Catalogue. Type PSR Type PSS Type PST/PSTB. Latest updated not printed, only in PDF-format

NXL Series Inverters. HVAC Inverters made simple

GE Energy Industrial Solutions. New. AF-6 Series Drives. Built-in features Built-in simplicity. GE imagination at work

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Softstarters. Index. 5 - Softstarters. Phone: Fax: Web: info@clrwtr.com.

MOTOR CONTROL IS OUR NATURE

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

AIS750 Series Alarm Annunciator

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

FIREDEX Conventional Fire Panels

RVS-DXM Instruction Manual

Additional Benefits of VFDs In addition to energy savings and better process control, VFDs can provide other benefits:

Torque control MSF Softstarter

PRODUCT LIST Facility DDC Access WebXL DDC

Single and three phase modular Automatic Transfer Switch from 40 to 160 A

ATS - Automatic Changeover

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

... Electronic Softstarter...

Quick Connect. quick - simple - efficient.

Electric Rotary Actuator - On/Off or programmable control actuator

SMC -3 Specifications

Safety technique. Emergency stop module BO 5988 safemaster

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

HERZ-Thermal Actuators

Thyristor-controlled power supplies and battery chargers

WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE

Low Voltage Products. Switches Automatic Transfer Switches

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

1.44 kw Programmable DC Power Supplies XLN Series

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

*.ppt 11/2/ :48 PM 1

Safety Relays ESM/ESM-F

Safety automation solutions

A1000 Cheat Sheet (Open Loop Vector)

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930

Reduced Voltage Starters Section 2

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Application/Connection Examples

Electronic, Digital and Mechanical Vibration Switches

Voltage Regulator SPAU 341 C. Product Guide

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

Magnum Mobile Generator MMG55 Specifications

Cooking at the Speed of light!

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

Heating, air-conditioning, cooling

1 Application Description Objective Goals... 3

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

Electronic overload relay EF19 and EF45

VARIABLE FREQUENCY DRIVES Revised 4/30/ Mechanical Systems

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Control. Overview. Contents

Electronic Control Devices The European Product Catalogue 2007

AC Variable Speed Drive. Powerful Performance. Advanced motor control. 0.75kW 250kW / 1HP 350HP V Single & 3 Phase Input

Permissible ambient temperature Operation Storage, transport

Multifunction devices

PNOZsigma - Base units

ECOCIAT. Domestic hot water heat recovery unit

MLC TM Maximum Productivity and Versatility for Control without Compromise!

General Purpose, Interposing, Solid-State and Specialty Relays. Bulletin 700

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

NX Series Inverters. HVAC Pocket Programming Guide

Circuit Breakers. NRC Series. NRC Series

Electric Flow Boiler

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Transcription:

SOFT STARTERS Easy Selection Guide MOTOR CONTROL AND DRIVES nhp.com.au

Follow the three Easy Steps to select the right soft starter for your motor application. STEP 3: Select your motor connection STEP : Select your motor full load current rating Soft starters are commonly used in motor applications. Motor data ratings are referred to as the power of the motor in kw and the full load current (FLC) or nominal current in amps. What is the kw and motor full load current? Both of these ratings can be found on the name plate of the motor or directly from the motor manufacturer. When selecting a soft starter be sure to check the FLC rating is sufficient to run the motor. 3 3 wire motor connection 6 wire motor connection Category Light duty Medium duty Heavy duty duty Start condition 3x FLC, 0 second start 3.5x FLC, 5 second start 4x FLC, 0 second start 4.5x FLC, 30 second start Motor kw Typical ratings for 3-phase motor @ 45 V AC Approx. full Approx. full load current Motor kw load current Motor kw @ 45 V AC @ 45 V AC Approx. full load current @ 45 V AC 0.37 30 55 50 45 0.55.6 37 66 300 55 0.75 45 80 35 535.5 3.5 55 00 375 65. 5 75 35 400 670 4 8.4 90 65 450 750 5.5 0 00 500 80 7.5 4 3 40 560 90 60 80 630 00 5 8 85 35 700 00 8.5 35 00 340 800 380 40 0 390 900 500 STEP : Select your Application Soft starter product selection is influenced by the type of motor application. Find your application on the table below. Once the motor application is selected, note the corresponding duty category. Application Application Application Agitator Heavy Debarker Medium Palletiser Atomiser Heavy Dryer Planer Medium Bottle washer Light Dust collector Medium Press Medium Centrifuge Edger Medium Pump - Bore Light Chipper Fan - Axial (Damped) Medium Pump - Centrifugal Medium Compressor - Recip (Loaded) Compressor - Recip (Unloaded) Compressor -Screw (Loaded) Compressor -Screw (Unloaded) Heavy Fan - Axial (Un-damped) Fan - Centrifugal (Damped) Fan - Centrifugal Un-damped) Pump - Positive displacement Heavy Medium Pump - Slurry Re-pulper Heavy Fan - High pressure Rotary table Heavy Conveyor - Belt Grinder Medium Sander Heavy Conveyor - Roller Medium Hydraulic power pack Medium Saw - Bandsaw Conveyor Screw Heavy Mill Saw - Circular Medium Crusher - Cone Medium Mill - Ball Separator Crusher - Jaw Mill - Hammer Shredder Crusher - Rotary Medium Mill - Roller Slicer Light Crusher - Vertical impact Medium Mixer Tumbler Heavy Note: The above table is a guide only. If your application is not on the above table contact NHP for recommendations. 4 Most common motor connection Suitable for most motors. Convenient if replacing an existing star delta starter with a new soft starter STEP 4: Select either the Sprecher+Schuh PCS or AuCom EMX3 below Using the table below and information from the following pages ask the customer which features are required. Features S+S PCS AuCom EMX3 Catalogue Reference PCS EMX3... Nominal -3 wire connection 4 85 A 3 600 A current range -6 wire connection 5. 47 A 35 400 A Supply Voltage 00 480 VAC 00 440 VAC 690 VAC variant available User Adjustments DIP switches & rotary Multi-line digital keypad with plain English dial LCD display (removable keypad) Includes local control push buttons (Start, Stop, Reset, Local/Remote) Operating Temperature -5...50 o C -0.60 o C, above 40 o C with derating Internal Bypass Contacts Yes, Standard Yes, Standard (EMX3-xxxxB models only) Electronic Motor Protection Motor overload with adj. Motor overload with programmable thermal trip class model Phase imbalance Current imbalance Phase loss / open load Phase loss / motor connection Phase sequence Phase sequence Starter over temperature Starter over temperature Shorted SCR Shorted SCR Motor thermistor Excess start time Electronic shearpin Under-current Supply frequency Aux. input trip Comms error RTD input (expandable) Ground fault (optional) Communication Options Nil DeviceNet Profibus Modbus RTU Ethernet (Ethernet IP, Modbus TCP, Profinet) USB Applications Light, Medium duty Light, Medium, Heavy, duty Page reference 4 8 3

Sprecher+Schuh PCS Providing users with consistent performance in a compact, space-saving design, the PCS soft starter is an intelligent and cost-effective means to control your motor application. Providing installation flexibility, integral bypass, 3 wire / 6 wire motor connection, as well as choice of starting and stopping modes, the PCS is ideal for many applications. Up to 85 A (3 wire) / 47 A (6 wire) Compact size, reducing panel space requirements Integral bypass, for minimal heat dissipation during run time True three phase control, for smoother starting and minimal thermal stress on the motor 3 wire / 6 wire motor connection for flexibility of installation Choice of starting and stopping modes: Start: Timed Voltage Ramp, Current Limit, Kick-Start Stop: Soft Stop, Coast to Stop Electronic Motor Protection: Motor overload with adj. trip class (OFF, 0, 5, 0 seconds), phase imbalance, phase loss / open load, phase sequence, starter over temperature, shorted SCR 3 wire motor connection Ordering details With knowledge of motor full load current, application duty category (page 3), motor power connection (page 3), the appropriate PCS can be selected. 3 wire motor connection is the most common motor connection. Alternatively, 6 wire motor connection is suitable for most motors. 6 wire motor connection is a convenient option if replacing an existing star delta starter with a new soft starter. Light / Medium 00-40 V AC Control 4 V AC/DC Control Setting Range 3 A PCS-003-480V PCS-003-480V-04 3 9 A PCS-009-480V PCS-009-480V-04 8 6 A PCS-06-480V PCS-06-480V-04 9.5 9 A PCS-09-480V PCS-09-480V-04.5 5 A PCS-05-480V PCS-05-480V-04 5 30 A PCS-030-480V PCS-030-480V-04 8.5 37 A PCS-037-480V PCS-037-480V-04.5 43 A PCS-043-480V PCS-043-480V-04 30 60 A PCS-060-480V PCS-060-480V-04 4.5 85 A PCS-085-480V PCS-085-480V-04 Test / reset button This dual purpose button allows testing of the trip function without motor current flow and fault resetting under normal operating conditions. Optional remote or standard local reset for your convenience. DIP switch set-up Quick, accurate and repeatable settings are assured through a simple to use DIP switch selection panel. Marking tag holder Used with marking tags to provide quick and accurate starter identification. Potentiometer A clearly labeled potentiometer is used to adjust motor full load current setting. The lowest minimum Full Load Current (FLC) setting is one third of the soft starters current rating. The motor connected must have an FLC within this range. E.g: PCS-009-480 V has an overload range of 3 A to 9 A. 6 wire motor connection.6 5. A PCS-003-480V PCS-003-480V-04 8 6 A PCS-009-480V PCS-009-480V-04 3.8 7.6 A PCS-06-480V PCS-06-480V-04 6.4 3.8 A PCS-09-480V PCS-09-480V-04 43.5 A PCS-05-480V PCS-05-480V-04 6 5 A PCS-030-480V PCS-030-480V-04 3 64 A PCS-037-480V PCS-037-480V-04 37 74 A PCS-043-480V PCS-043-480V-04 5 04 A PCS-060-480V PCS-060-480V-04 73.5 47 A PCS-085-480V PCS-085-480V-04 Above ratings for the PCS refer to light / medium duty. For heavy and severe duty loads refer to EMX3, or consult NHP for recommendations. As standard, the PCS is capable of 3 wire and 6 wire motor connection. When using the PCS in 6 wire mode, the overload current must be set to 58 % of the motor FLC. E.g: a 50 amp motor in 6 wire would use a PCS-030-480 V and the overload current setting would be set to 9 Amps. LED status indication Clear indication of all motor and system fault conditions via a flash coded LED. DIN-rail mounting & screw fixing Complete with DIN-rail mounting and screw fixing, the PCS is easy to install. Configurable Auxiliary Contacts As standard, the PCS provides a configurable (normal or up-to-speed) normally open (N/O) auxiliary contact for motor run status indication. The PCS has a line of side-mount configurable (normal or up-to-speed) auxiliary contacts, allowing you more flexibility. Integral motor overload/fault contact A normally open (N/O) fault contact for indication of motor overload/fault is included on the PCS. 4 5

PCS Accessories Side-mounted auxiliary contacts ) x N/O contact x N/C contact x N/O contacts x N/O and x N/C contact Contactor connection modules Connects PCS-003 09 to CA7-9 3 Connects PCS-030 037 to CA7-30 37 PCS-PA-0 PCS-PA-0 PCS-PA-0 PCS-PA PCS-3-CI3 PCS-3-CI37 Enclosed PCS solutions - for 3 wire applications The PCS soft starters are also available in enclosed format and are provided as standard assemblies or manufactured to specifications. The enclosed PCS solutions listed below are suitable for 3 wire applications. Standard control voltage is 40 VAC. Standard assembly includes line contactor, PCS soft starter with integral bypass contacts and electronic motor protection with adjustable trip class (OFF, 0, 5, 0), control circuit breaker as well as start, stop and reset pushbuttons. Selecting your PCS from page 5, enclosed soft starter options include insulated polycarbonate or steel enclosures, both with IP 66 protection. Insulated enclosed,...85 A * Insulated polycarbonate enclosures, IP 66 protection Remote reset magnets 4 V AC coil CMR7-4VA 40 V AC coil CMR7-30VA 4 V DC coil CMR7-4VDC Cooling fans Frame : PCS-003 37 PCV-064 Frame : PCS-045 85 PCV-47 ) Marking tags Marking tag covers (x 00) CA7-FMP Transparent cover (x 00) CA7-FMC Marking tag stickers (x 00) CA7-FMS PCS Soft Starter Setting Range Amps Line contactor Dimensions (mm) Height Width Depth PCS-003-480V 3 A CA7-9 80 80 80 SSPC7-.-40VAC PCS-009-480V 3 9 A CA7-9 80 80 80 SSPC7-4-40VAC PCS-06-480V 8 6 A CA7-6 80 80 80 SSPC7-7.5-40VAC PCS-09-480V 9.5 9 A CA7-3 80 80 80 SSPC7-9-40VAC PCS-05-480V.5 5 A CA7-30 80 80 80 SSPC7--40VAC PCS-030-480V 5 30 A CA7-30 80 80 80 SSPC7-5-40VAC PCS-037-480V 8.5 37 A CA7-37 80 380 80 SSPC7-8.5-40VAC PCS-043-480V.5 43 A CA7-43 600 400 0 SSPC7--40VAC PCS-060-480V 30 60 A CA7-60 600 400 0 SSPC7-30-40VAC PCS-085-480V 4.5 85 A CA7-85 600 400 0 SSPC7-45-40VAC PCS dimensions (mm) and weights (kg) Steel enclosed,...85 A * Quality steel enclosures, IP 66 protection Width Height Depth kg PCS-003...037 45 40 0 0.86 PCS-043...085 7 06 3.5 PCS Soft Starter Setting Range Amps Line contactor Dimensions (mm) Height Width Depth PCS-003-480V 3 A CA7-9 300 300 0 MSSPC7-.-40VAC PCS-009-480V 3 9 A CA7-9 300 300 0 MSSPC7-4-40VAC PCS-06-480V 8 6 A CA7-6 300 300 0 MSSPC7-7.5-40VAC PCS-09-480V 9.5 9 A CA7-3 300 300 0 MSSPC7-9-40VAC PCS-05-480V.5 5 A CA7-30 300 300 0 MSSPC7--40VAC PCS-030-480V 5 30 A CA7-30 300 300 0 MSSPC7-5-40VAC PCS-037-480V 8.5 37 A CA7-37 400 300 0 MSSPC7-8.5-40VAC PCS-043-480V.5 43 A CA7-43 500 400 0 MSSPC7--40VAC PCS-060-480V 30 60 A CA7-60 500 400 0 MSSPC7-30-40VAC PCS-085-480V 4.5 85 A CA7-85 500 400 0 MSSPC7-45-40VAC ) As standard, the PCS includes a configurable (normal or up-to-speed) normally open (N/O) auxiliary contact. ) Frame size cooling fans come complete as standard. 6 7

AuCom EMX3 Providing users with unprecedented motor control, protection and monitoring capabilities, the EMX3 soft starter is suitable for a vast range of industrial applications. Easy to use and with numerous standard features, including integral bypass (up to 000 A), user friendly LCD display in plain English, advanced electronic motor protection, multiple starting and stopping modes, the EMX3 is truly an outstanding soft starter. Up to 000 A (3 wire) / 500 A (6 wire) with integral bypass ) Extremely user friendly with plain English LCD display, for easy setup True three phase control, for smoother starting and minimal thermal stress on the motor 3 wire / 6 wire motor connection (auto-detected) for flexibility of installation Multiple starting and stopping modes: Start: Constant Current, Current Ramp, XLR-8 Adaptive Acceleration Control, Kick-Start Stop: Soft Stop, XLR-8, Adaptive Deceleration Control, Brake mode, Coast to Stop Advanced Electronic Motor Protection: Motor overload with programmable thermal model, current imbalance, phase loss / motor connection, motor thermistor input, phase sequence, excess start time, electronic shear pin, under-current, shorted SCR, supply frequency, aux. input trip, comms error, RTD input (expandable), ground fault (optional) Optional communications: DeviceNet, Profibus, Modbus RTU, Ethernet modules USB module for connecting EMX3 to PC Additional User-friendly Features Large viewable screen with real language text, no more trip codes Status LEDs for immediate feedback 3 wire motor connection Ensure the EMX3 maximum motor FLC rating is greater than or equal to the motor FLC rating. Ordering details With knowledge of motor full load current, application duty category (page 3), motor power connection (page 3), the appropriate EMX3 can be selected. 3 wire motor connection is the most common motor connection. Alternatively, 6 wire motor connection is suitable for most motors. 6 wire motor connection is a convenient option if replacing an existing star delta starter with a new soft starter. EMX3 maximum motor FLC ratings Light Medium Heavy 0-440 V AC Control 4 V AC/DC Control 3 A 0 A 7 A 5 A EMX3-003B-V4-C-H EMX3-003B-V4-C-H 43 A 37 A 3 A 6 A EMX3-0043B-V4-C-H EMX3-0043B-V4-C-H 50 A 44 A 37 A 30 A EMX3-0050B-V4-C-H EMX3-0050B-V4-C-H 53 A 53 A 46 A 37 A EMX3-0053B-V4-C-H EMX3-0053B-V4-C-H 76 A 64 A 55 A 47 A EMX3-0076B-V4-C-H EMX3-0076B-V4-C-H 97 A 8 A 69 A 58 A EMX3-0097B-V4-C-H EMX3-0097B-V4-C-H 00 A 88 A 74 A 6 A EMX3-000B-V4-C-H EMX3-000B-V4-C-H 05 A 05 A 95 A 78 A EMX3-005B-V4-C-H EMX3-005B-V4-C-H 45 A 3 A 06 A 90 A EMX3-045B-V4-C-H EMX3-045B-V4-C-H 70 A 45 A A 97 A EMX3-070B-V4-C-H EMX3-070B-V4-C-H 00 A 89 A 60 A 34 A EMX3-000B-V4-C-H EMX3-000B-V4-C-H 0 A 0 A 78 A 48 A EMX3-00B-V4-C-H EMX3-00B-V4-C-H 55 A 3 A 0 A 76 A EMX3-055B-V4-C-H EMX3-055B-V4-C-H 350 A 306 A 66 A 30 A EMX3-0350B-V4-C-H EMX3-0350B-V4-C-H 45 A 37 A 3 A 76 A EMX3-045B-V4-C-H EMX3-045B-V4-C-H 500 A 445 A 383 A 36 A EMX3-0500B-V4-C-H EMX3-0500B-V4-C-H 580 A 49 A 45 A 364 A EMX3-0580B-V4-C-H EMX3-0580B-V4-C-H 700 A 59 A 5 A 438 A EMX3-0700B-V4-C-H EMX3-0700B-V4-C-H 80 A 705 A 606 A 56 A EMX3-080B-V4-C-H EMX3-080B-V4-C-H 90 A 804 A 684 A 57 A EMX3-090B-V4-C-H EMX3-090B-V4-C-H 000 A 936 A 796 A 664 A EMX3-000B-V4-C-H EMX3-000B-V4-C-H Mounting holes for easy mounting and removal Top and bottom cable retainers for tidier wiring Small footprint and depth saves space Start, Stop, Reset, Local/ Remote pushbuttons Shortcut buttons for quick access to common tasks IP 65 Removable keypad for mounting on cabinet exterior Easy access door hides cables from operator, but allows easy access for installers Unique wiring loom separates wires for easy install, greater access allows access from top, left or bottom for more flexibility ) Integral bypass ensures minimal heat dissipation during run time. Also available: continuously rated models up to 600A (3 wire) / 400A (6 wire). Consult NHP. 6 wire motor connection Ensure the EMX3 maximum motor FLC rating is greater than or equal to the motor FLC rating. 34 A 30 A 6 A A EMX3-003B-V4-C-H EMX3-003B-V4-C-H 64 A 59 A 5 A 44 A EMX3-0043B-V4-C-H EMX3-0043B-V4-C-H 75 A 66 A 55 A 45 A EMX3-0050B-V4-C-H EMX3-0050B-V4-C-H 79 A 79 A 69 A 55 A EMX3-0053B-V4-C-H EMX3-0053B-V4-C-H 4 A 96 A 83 A 70 A EMX3-0076B-V4-C-H EMX3-0076B-V4-C-H 45 A 3 A 04 A 87 A EMX3-0097B-V4-C-H EMX3-0097B-V4-C-H 50 A 3 A A 9 A EMX3-000B-V4-C-H EMX3-000B-V4-C-H 57 A 57 A 43 A 7 A EMX3-005B-V4-C-H EMX3-005B-V4-C-H 7 A 84 A 59 A 36 A EMX3-045B-V4-C-H EMX3-045B-V4-C-H 55 A 7 A 8 A 46 A EMX3-070B-V4-C-H EMX3-070B-V4-C-H 300 A 83 A 4 A 00 A EMX3-000B-V4-C-H EMX3-000B-V4-C-H 330 A 35 A 68 A 3 A EMX3-00B-V4-C-H EMX3-00B-V4-C-H 38 A 346 A 30 A 64 A EMX3-055B-V4-C-H EMX3-055B-V4-C-H 55 A 459 A 399 A 345 A EMX3-0350B-V4-C-H EMX3-0350B-V4-C-H 638 A 557 A 48 A 44 A EMX3-045B-V4-C-H EMX3-045B-V4-C-H 750 A 668 A 575 A 490 A EMX3-0500B-V4-C-H EMX3-0500B-V4-C-H 870 A 738 A 637 A 546 A EMX3-0580B-V4-C-H EMX3-0580B-V4-C-H 050 A 889 A 768 A 658 A EMX3-0700B-V4-C-H EMX3-0700B-V4-C-H 30 A 058 A 90 A 774 A EMX3-080B-V4-C-H EMX3-080B-V4-C-H 380 A 06 A 06 A 857 A EMX3-090B-V4-C-H EMX3-090B-V4-C-H 500 A 404 A 94 A 997 A EMX3-000B-V4-C-H EMX3-000B-V4-C-H 8 9

Turn over a new page with the NHP ecatalogues App! AuCom EMX3 Accessories Communication Modules Modbus RTU DeviceNet Profibus Ethernet IP USB module (EMX3 to PC via USB) PIM-MB-0 PIM-DN-0 PIM-PB-0 PIM-EI-0 PIM-USB-0 Expansion cards ) Input / Output card ) 995-04803-00 RTD and ground fault card 995-04805-00 Keypad Remote Mounting Kit Remote mounting kit (includes 3 m cable) 995-0833-00 EMX3 dimensions (mm) and weights (kg) Download Now! Scan to download the ecatalogues App. Width Height Depth kg EMX3-003B...0053B 56 95 9 3. EMX3-0076B 56 95 3 3.5 EMX3-0097B...005B 56 95 3 4.8 EMX3-045B...00B 8 438 50 6 EMX3-055B 44 440 98 6 EMX3-0350B...045B 44 440 98 30. EMX3-0500B...0580B 433 640 97 49.5 EMX3-0700B...000B 433 640 97 60 Enclosed EMX3 solutions The EMX3 is also available as an enclosed soft starter solution. Contact NHP for further information. ) Each EMX3 can support a maximum of one expansion card at a time. nhp.com.au ) As standard, EMX3 includes 5x digital inputs, 4x relay outputs (x changeover), x analogue output. Expansion card adds x digital inputs, 3x relay outputs, x analogue input, x analogue output. 3 ) For EMX3-045B to EMX3-000B, width and height are the unit footprint. Busbars are not included as this NECATPUB 03 3 dimension will vary with busbar configuration. 0

Scan the QR code to download the ecatalogues App AUSTRALIA nhp.com.au SALES 300 NHP NHP FAX 300 NHP FAX Victoria Melbourne 43-67 River Street Richmond VIC 3 Tel +6 3 949 999 Laverton 04-06 William Angliss Drive Laverton North VIC 306 Tel +6 3 9368 90 Albury / Wodonga 847 Ramsden Drive Albury NSW 640 Tel +6 6049 0600 Fax +6 3 605 059 Dandenong 40-4 Cyber Loop Dandenong South VIC 375 Tel +6 3 8773 6400 Fax +6 3 8768 85 Tasmania Hobart Unit 65 Albert Street Moonah TAS 7009 Tel +6 3 68 9575 Fax +6 3 68 9757 Launceston Unit 3 3-7 Merino Street Kings Meadows TAS 749 Tel +6 3 6345 600 Fax +6 3 6344 634 New South Wales Sydney 30-34 Day Street North Silverwater NSW 8 Tel +6 9748 3444 Newcastle 575 Maitland Road Mayfield West NSW 304 Tel +6 4960 0 Fax +6 4960 03 Wollongong 34 Industrial Road Unanderra NSW 56 Tel +6 47 5763 Fax +6 47 5957 ACT Canberra Unit 87 Gladstone Street Fyshwick ACT 609 Tel +6 680 9888 Fax +6 680 9588 Western Australia Perth 38 Belmont Ave Rivervale WA 603 Tel +6 8 977 777 Northern Territory Darwin 3 Steele Street Winnellie NT 080 Tel +6 8 8947 666 Fax +6 8 8947 049 Queensland Brisbane 6 Riverview Place Murarrie QLD 47 Tel +6 7 3909 4999 Townsville 5 Leyland Street Garbutt QLD 484 Tel +6 7 4779 0700 Fax +6 7 4775 457 Rockhampton Lawson Street Parkhurst QLD 470 Tel +6 7 497 77 Fax +6 7 49 947 Toowoomba Cnr Carroll Street and Struan Court QLD 4350 Tel +6 7 4634 4799 Fax +6 7 4633 796 Cairns Unit Bramp Close Portsmith QLD 4870 Tel +6 7 4035 6888 Fax +6 7 4035 6999 South Australia Adelaide 36-38 Croydon Road Keswick SA 5035 Tel +6 8 897 9055 NHP Electrical Engineering Products Pty Ltd A.B.N. 84 004 304 8 NHPNTUSOFTSTARTAUSESG 06 3 Copyright NHP 03