Maintenance and Trou ble shoot ing Guide



Similar documents
Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information

Oil and Coolant Circulating Heating System. Model - OCSM

, User s Manual

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Ceiling Mount Air Handler Manual

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

INSTALLATION INSTRUCTION

TROU BLE SHOOTING VIKING ALARM VALVES

Installation and Operation Guide for PD5100 Automatic Transfer Switch

ATS Overhead Table Shelf System INSTRUCTION MANUAL

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Manual for Fire Suppression & Methane Detection System

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Cooling system components, removing and installing

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

Install Guide CT101. Caution. Caution

USER S MANUAL HSC-24A

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Line to Refrigerator Ice/Water Dispenser

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

User Manual THR840DUK Digital Thermostat

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

E2 Series Electric Furnaces

INSTALLER S & OWNER S MANUAL

CARING FOR YOUR WATER HEATER

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

Leak Detection System

T-Series Air Conditioner T62 Model

Utility Distribution Systems

i ChatterBox! Motorcycle Security

Dehumidifier Users manual. For Models: DH45S DH65S

Ozone Generator Manual

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

LOBOY 16 AIR CONDITIONERS

ROTOR LOADER OWNER S MANUAL

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Float and Thermostatic Traps Series H, C and X

Super Cascade Filtration Systems (CE)

Owner s Manual Phoenix Solution. LGR Performance Amplifier

Water Leak Detection System

Installation Instructions WARNING: WARNING: WARNING: WARNING: WARNING:

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Volkswagen Golf > VW Rabbit GTI 2006->

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Cooling system components, removing and installing

16/32 Channel 1U Rack Mount CCTV Power Supply

POOL SUNSHINE IONIZER MODELS SPD, SPD2 AND SPS INSTALLATION INSTRUCTIONS

Operating Manual. Los Angeles Abrasion Machine HM-70A & HM-70AF

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Installation and Operating Instructions (for chargers shown below)

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

Portable Air Conditioner

About this Manual. Support for Your Product

INSTALLATION MANUAL. Address card EKAC10B

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930

Addendum to the Operating Instructions

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Installation Instructions

StorTrends 3400 Hardware Guide for Onsite Support

Installation, Operation & Service Manual

Thermo Top - Troubleshooting Tree

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

FLEXIT S4 R S6 R S7 R

Panel Mounted Air Conditioners by Dantherm, Inc.

SunMaxx Solar Filling Station Operating Instructions

PALLET JACK TON

HEAT PUMP PROGRAMMABLE THERMOSTAT

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

ECM. Service Guide.

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

WE-350 Series ¼ Turn Electric Actuator

Transcription:

SGH Steam Gen er ating Hu mid i fiers Maintenance and Trou ble shoot ing Guide IMPORTANT: Read and save this guide for future reference. This guide to be left with equipment owner. SL-14060 Form # 99-427 Rev. 1 / 150-1636 Rev. A

Ta ble Of Contents MAINTENANCE 1 WHEN TO REPLACE THE STEAM CYL IN DER.............................. 1 HOW TO REMOVE THE STEAM CYL IN DER............................... 1 MAN DA TORY CLEANING OF THE DRAIN VALVE............................ 2 HOW TO IN STALL THE RE PLACE MENT CYL IN DER... 2 EX TENDED SHUT DOWN......................................... 2 BUILT ON AND REMOTE MOUNTED BLOWER PACKS........................ 3 TROU BLE SHOOTING 3 PRE REQ UI SITES............................................. 3 BLOWER PACK OP ER A TION.... 4 USING THE WIRING DI A GRAM...4 PRO CE DURES AND TERMS USED IN DI AG NOSING... 4 PRIN CI PLE OF OP ER A TION... 4 FILL RATE............................................... 5 DRAIN TIME.............................................. 5 RATED AMPS............................................. 5 SHORT CY CLING... 5 FOAMING............................................... 5 BACKPRESSURE... 5 MON I TORED LEG... 5 RE SET UNIT (HU MID I FIERS).... 5 DI AG NOS TIC PRO CE DURES - TROU BLE SHOOTING.... 6 WIRING DI A GRAM 7

MAINTENANCE WARNING! The plumbing and electrical compartments contain high voltage components and wiring. The access door(s) is equipped with a lock. Access should be limited to authorized personnel only. WHEN TO REPLACE THE STEAM CYLINDER The steam cylinder is disposable and must be replaced at end of cylinder life. Cylinder life is dependent on water supply conditions and humidifier usage. Failure to replace the cylinder at the end of cylinder life may result in unit damage. Liebert is not responsible for any damages resulting from, or attributable to, the failure to replace a used cylinder (see Manufacturer s Warranty). There are many indications, each of which signifies the end of cylinder life. 1. After a period of operation (not on initial start-up), the water level will approach the top of the cylinder. (Life varies from 500 to 2000 operating hours, as illustrated in Figure #1.) Figure #1 Water Conditions vs. Cylinder Life 30 20 10 5 Capacity Adjustment Setting 100% 50% 25% 500 1000 2000 4000 Cylinder Life Expectancy 8000 (average operating hours) 2. Each SGH humidifier has a yellow status lamp, a green status lamp, and a relay for remote indication. Double units (models SGH 200) have two of each. 3. When the yellow status lamp is on, the water level is detected as being at the top of the cylinder. This is normal on start-up, but as the contained water concentrates, the water will stabilize at a lower water level and the yellow lamp will be off. 500 400 200 100 available at end-of-cylinder-life, the required steam output rate can no longer be maintained. 5. At this stage, the yellow lamp flashes (4 times in sequence) and the green lamp is off, telling the user that the cylinder has reached the end of its life and will need to be replaced. The SGH will not operate at end of cylinder life fault. HOW TO REMOVE THE STEAM CYLINDER 1. (It is advisable to keep a spare cylinder in stock throughout the humidification season.) When ordering a replacement steam cylinder, always quote the three or five digit model number on the label applied to the cylinder or quote the unit s serial number, model and voltage located on the spec label (nameplate). 2. Turn off water supply to unit. 3. Open plumbing door. 4. The used cylinder must be drained completely before removal. If the water has just been boiling, allow it to cool before draining. Push the ON/OFF/DRAIN switch to the MANUAL DRAIN position. Leave it in this position just long enough to drain the cylinder (usually less than 10 minutes). 5. When completely drained, push the main ON/OFF/DRAIN switch back to the OFF position. 6. Once drained, open the main electrical disconnect. The electrical disconnect is to remain open during the entire cylinder change operation. 7. Cylinder plugs are attached to the primary voltage cylinder wires. (The plugs remain attached to the wires unless they have to be replaced due to damage.) The plugs are press-fitted over the electrode pins protruding from the top of the cylinder. Remove cylinder plugs from cylinder by pulling vertically. 8. Using slot screwdriver, loosen the steam hose clamp(s) and pull steam hose off the cylinder vertically. 9. Using a small slotted screwdriver, depress tab on the re-usable tie wrap, if present, around the middle of the cylinder. This will allow you to remove the tie wrap so you can re-use it later on. 10. Cylinder is now ready to be lifted out of the unit. CAUTION: Cylinder and any undrained water might still be HOT. 4. When the cylinder is fully used, the water level will have returned to the top of the cylinder. Since there is no longer any clean electrode surface - 1 -

MANDATORY CLEANING OF THE DRAIN VALVE Always clean the drain valve before installing a new cylinder since the valve port may be as dirty as the used cylinder. 1. Remove used cylinder as previously described. 2. Remove two screws securing drain valve body to drain pan. Disconnect the two slip-on terminals from the two tabs on the (24VAC) drain valve coil. 3. Remove hose clip and hose connection from drain valve body. 4. Drain valve assembly is now free to be taken to a sink for disassembly and cleaning. 5. Remove snap-fit red cap from coil assembly and slide coil off the actuator. 6. Loosen actuator with wrench and unscrew from plastic valve body. 7. Clean the exposed core and spring and plastic drain valve port. 8. Important: Tapered end of spring must be installed toward the solenoid. Reassemble, tighten actuator 1/4-turn past hand-tight. See Figure #4. Figure #4 Re as sem bly of the Drain Valve and Fill Valve Plunger Actuator Spring Sleeve Holding Coil Male Slip-on Connection Tabs 9. Clean out the end of the hose, then reconnect it to the drain valve body with the clamp. 10. Fit mounting screws through drain valve body, one for the green ground wire. 11. WARNING: To prevent the possibility of electrical shock the green ground wire must be reinstalled before power is restored. 12. Push the two slip-on terminals back onto the two tabs on the coil. The terminals, although not identical, are reversible. HOW TO INSTALL THE REPLACEMENT CYLINDER Note: Liebert does not recommend the use of any acid solutions to clean the used cylinder. Always replace a used cylinder. 1. Reverse procedure in the section How to remove steam cylinder to install new cylinder. With the exception that the main disconnect is to be left open until cylinder is completely installed and reconnected. 2. Ensure that cylinder is secured properly by the re-usable tie wrap and mounting brackets within the unit. (Verify that it is the right cylinder type). 3. The cylinder plug wires are color-coded in accordance with colored dots beside the electrode pins on top of the cylinder. 4. This color-coding must be adhered to when replacing cylinder plugs on pins. 5. With cylinders having six primary voltage cylinder plugs, it should be noted that there are two of each color. 6. Care must be taken so that cylinder leads of the same color are always directly opposite each other as indicated by the dot formation on the top of the cylinder. 7. The crimped on blue plug on all units is for the sensor electrode which always goes on the single pin surrounded by a plastic shoulder. 8. Ensure that cylinder plugs fit snugly on the pins. 9. If cylinder plugs become loose, it is best to obtain a new replacement plug. Consult factory. EXTENDED SHUTDOWN Before disconnecting power to the humidifier for a period of extended shutdown, ALWAYS DRAIN the cylinder first. Otherwise, the electrodes are subject to harmful corrosion which drastically shortens cylinder life. Do NOT leave the switch in the DRAIN position indefinitely as the drain coil could burn out. Leave the switch in the OFF position and open the main external fused disconnect to stop power to the humidifier. Close the shut off valve in the water supply line feeding the humidifier. Lock the cabinet door(s) to prevent unauthorized tampering. All doors are factory supplied with keyed locks. DO NOT LEAVE KEY IN - 2 -

Figure #3 Cyl in der Plug In stal la tion 10 GA Wire Cylinder Plug Installation Instruction For Part # 135-4012 (R, Y, or B) 0.50" Cylinder Plug Hex (Allen) 5/64" (2 mm) TROUBLESHOOTING PLEASE READ THIS SECTION BEFORE REFERENCING SPECIFIC DIAGNOSTIC MESSAGES. 1. Ensure the installation detail conforms with the recommendations contained in the Installation Manual. 2. Understanding the Principle of Operation is an asset when troubleshooting. This information is readily available from your local representative. Oil Here Figure #4 Where To Oil 3. When contacting your local representative or Liebert, for troubleshooting assistance, please ensure the serial number has been obtained for reference purposes. 4. Whenever the troubleshooting steps indicate a problem with the main PCB, first check all connections at the main PCB before ordering replacements. PREREQUISITES - on/off/drain switch must be switched on - control circuit 8-10 must be made LOCK. ACCESS SHOULD BE LIMITED TO AUTHORIZED PERSONNEL ONLY. As long as the SGH is powered, it will automatically drain the cylinder when there has not been a call for humidity for a 72 hour period of time. The cylinder will remain empty until there is a call for humidity at which time the fill valve will open and refill the cylinder. The unit will go through its normal stabilization process for optimum operation. This feature will reduce the possibility of corrosion of the electrodes and the possible accumulation of algae and bacteria growing in the cylinder. BUILT ON AND REMOTE MOUNTED BLOWER PACKS FAN MOTOR OILING: The blower pack fan motor requires occasional oiling of motor bearings. To do this, open up the blower pack top and oil the motor with ten drops of SAE-20 grade motor oil. Refer to Figure #4 for oiling slots. It is important to oil the fan motor every four months to preserve long life and to maintain the fan s warranty. It is not necessary to disassemble the fan/motor assembly. The exploded view is for visual purposes only. See Figure #4. - modulation humidistat, if present, must be calling - control circuit 82-83 and 84-85 must be made - door interlock switch must be made (in ter lock switch can be pulled out to op er ate unit) NOTE: Most water does not contain enough conductivity for full boil on initial start-up. Units will need to concentrate the water over a time period (hours to days). During this process both lights are on. (Also see Troubleshooting Guide). The SGH has built in diagnostic capabilities and will shutdown for the following reasons: - Ex cess cur rent - Max fill time - Change cyl in der/end of life See Figure #5 on page 4 for system messages and responses of the unit. - 3 -

Figure #5 Sys tem Mes sages and Re sponses UNIT OPERATION STATUS SGH UNIT STATUS LAMPS RE MOTE IN DI CA TION (24 VAC TO:) SYS TEM FAULTS* YEL LOW GREEN 61-20 Ex cess Cur rent OFF Flashing (1 time in sequence) OFF ON Max. Fill ing Time OFF Flashing (2 times in sequence) OFF ON Cylinder Spent OFF Flashing OFF ON (4 times in sequence) Maximum level ON ON ON OFF BLOWER PACK OPERATION An optional blower pack, if present, gets its primary voltage from inside the humidifier. This way, only one external power source has to be connected to the equipment. Blower packs are equipped with a control thermostat mounted on the steam distributor. When the humidifier generates steam the thermostat is heated, the contact is closed, and the fan is started. When steam is no longer being generated, the fan cuts out with a delay. If blower packs get overheated (malfunction of the air circulation), the manual reset safety thermostat interrupts the steam generation. To reset, switch off the humidifier and wait until the steam distributor cools down. Wait until the fan stops before throwing the disconnect switch. Failure to do so will trip the safety thermostat interrupts. Then remove left-hand side intake air filter and, using a screwdriver, press the reset button (marked with a red dot) inside the blower packs. All units are equipped with speed select switch. The switch is located on the right-hand side of the blower, inside the blower pack. To access the switch remove the right-hand side intake air filter. For blower packs working with humidifier outputs of 50lbs/hr or higher use the high speed setting. USING THE WIRING DIAGRAM Fixed to the inside of each unit s door is a wiring diagram showing all of the internal (and most of the external) wiring details. Additional external wiring details can also be found with any electrical accessories purchased from Liebert. The following is a detailed explanation of how the SGH humidifier (with and without options) operates. Direct reference is made to the wiring diagram. Reviewing the proper function in detail will make it easier to troubleshoot if something goes wrong. The wiring diagram details a 24 Vac control circuit and a primary voltage circuit. The contactor receives its hot leg from Relay #1 (RL1) on the control board. The fill receives its hot leg from terminal P4/2. The drain receives its hot leg from terminal P4/3. PROCEDURES AND TERMS USED IN DIAGNOSING PRINCIPLE OF OPERATION The conductivity of the water within the cylinder must be controlled in order for the humidifier to function properly. The fill and drain rates must be maintained. Filling too quickly can cause over-amping and automatic shutdown or blown fuses. Filling too slowly can cause insufficient steam output and foaming. Water supply pressure should be between 30 and 150 psig. Draining too slowly can cause over-concentration and malfunction due to foaming. These are just some examples of what can go wrong if the fill and drain rates are not maintained. FILL RATE Fill rates of suspect units should be checked. Fill rates should measure nominally at 1" to 1-1/2" of vertical rise in water level in the cylinder in one minute. A clogged fill valve will cause lower fill rate. The fill valve strainer is removable and can be cleaned. - 4 -

DIAGNOSTIC PROCEDURES - TROUBLESHOOTING The SGH controller provides a number of messages to simplify troubleshooting procedures. The following table presents fault messages displayed by the controller, their meaning and possible corrective actions. Refer to the preceding section for detailed information about terms used in the table. Unit Sta tus Lamp Symp tom Possible Cause Corrective Ac tion Yel low 1 flash in sequence Green Off Excess Cur rent. Cur rent drawn on mon i tored pri mary lead to cyl in der has reached or ex ceeded 130% of its rated amps. The unit will have tried to self-correct prior to sys tem shut down by draining wa ter from the cyl in - der and de-energising the contactor mo men tarily while it drains. This self cor rec tive ac - tion oc curs be tween 115% and 130% of it s rated amps. When con trol ler de tects ex - cess cur rent it also drains wa - ter from cyl in der. 1. Cyl in der wa ter is over-concentrated (too con - duc tive) due to re stricted drain, short-cycling by con - trols, sup ply wa ter not within ac cept able lim its (too con duc tive), im proper fill rate, in cor rect cyl in der be - ing used. 2. Wa ter level too high due to leak ing fill valve, ex cess con den sate re turn from steam line. 1. Turn unit back on and check the fill rate (1-1-1/2 inches per minute) 2. Manually drain cyl in der while check ing drain rates (See Figure #6). If too slow cor rect cause. 3. Once RH% set point is at tained, mon i - tor cy cle time and check for wa ter flow pres ence in over flow hose (symp tom of backpressure). 2 flashes in sequence Off Max i mum fill ing time. Neither Maximal Level (full cyl in der) is de tected, nor is there enough cur rent drawn to meet ca pac ity de mand within a pre-programmed in - ter val.(30 min utes) 1. Steam line re stric tion causing back pressure 2. Im proper fill rate 3. Leaking drain valve 1. Check for wa ter leak ing from drain. If pres ent, cor rect the drain valve de fi ciency (check for de bris hold ing drain coil plunges open) 2. Check steam line to the steam dis trib u - tor (duct or blower pack), for re stric tions that could cause high back pres sure. 3. Check wa ter level in cyl in der. 4. Full cyl in der not detected. - If full: Re set unit and en sure there is a de mand for steam (the green LED on unit door will stay il lu mi nated). Max i mal Level should be in di cated with both the green and yel low lights on the unit door il lu mi - nated. If Maximal Level is not in di cated, a prob lem ex ists with the high wa ter sen sor cir cuitry since the unit does not sense the wa ter level. - If not Full: Drain cylinder, re set unit and check the fill rate (1-1 ½ per min ute). If fill rate is cor rect, back pres sure is the likely cause and should be re checked. 4 flashes in sequence Off Cyl in der spent. Wa ter level stays high, cy - cling on and off Max i mal Level (full cyl in der), with out an in crease in out put/amp draw or reach ing de mand for an ex tended pe riod of time. 1.Normal on start-up with Re place the cyl in der im me di ately or if the a new cyl in der or a cyl in der cyl in der has been re placed re cently, check that has been completely for foaming. drained be cause of an ex - ten sive off pe riod. This can last sev eral hours un til the wa ter in the cyl in der has con cen trated. Or the elec - trodes can no lon ger pro - vide rated ca pac ity (or ad justed ca pac ity). Wa ter level au to mat i cally rises to seek out fresh elec trode sur face to meet the de - mand. - 6 -

DRAIN TIME Manual drain time of a half full cylinder depends on cylinder size (see Figure #6). If time measurements are longer, repeat with the external drain disconnected (and draining into a pail) to verify that the external drain is impeding flow. If it still does not drain, check for a clogged strainer or drain valve. A clogged strainer or drain valve will cause shortened cylinder life. Determine what caused the strainer or drain valve to clog in the first place. Do not assume that if a strainer and/or drain valve is clogged that it is to blame. If the external drain has been impeding flow then waste accumulates resulting in a clogged strainer or clogged drain. Clean the drain valve and install a fresh cylinder. Then measure the manual drain time with and without the external drain connected. Is the external drain impeding flow? Liebert recommends an open external drain line. CYL. SIZE (SERIES) RATED AMPS This refers to amps listed on the humidifier specification label. SHORT CYCLING Figure #6 Manual Drain Times PROPER TIME (sec) TO DRAIN MANUALLY FROM SEAM TO EMPTY BEIGE BODY DRAIN VALVE 600 2 min utes and 52 sec onds ± 10 sec. 300 43 seconds ± 2 sec. 200 25 seconds ± 1 sec. Occurs when the on time of the humidifier is less than ten minutes upon a call for humidity. To correct short cycling, all humidifiers have a capacity adjustment which allows the output of the humidifier to be reduced as low as 25% of rated output, thus extending the on time required to maintain output. Excessive short cycling may cause higher water conductivity (mineral content) than the unit is designed for. FOAMING A phenomenon which can occur in water when impurities, already in the water, reach an excess concentration as result of boiling away pure water and the continued boiling action agitating the contained water. The humidifier electronics are designed to prevent this occurrence although in extreme cases water will foam with little concentration, making it necessary to have the drain time of the water, contained in the cylinder, increased. Foaming is normally caused by short cycling, a restricted drain, or back pressure. The foam, generated in these instances, is conductive and may lead to a false full cylinder indication if the level of the foam approaches the top of the cylinder. BACKPRESSURE Restriction of steam flow caused by improperly sloped steam lines, elbows changing the direction of the steam flow from horizontal to vertical without a condensate drain leg, and any plumbing detail allowing the accumulation of condensate, undersized steam line, improper steam distributor, downward air flow onto the distributor creating excess static pressure at the steam outlets or high static pressure ducts (not probable). To overcome excess static pressure in the duct, a fill cup extension kit should be used. In downflow applications, a downflow distributor should be used but in some cases the fill cup extension will also be required. MONITORED LEG Refers to the primary wire, to the cylinder, which loops through the current sensing device on the main PCB. This wire is terminated at the red cylinder plug at the cylinder. Units with six primary wires to the cylinder will monitor only one of the two wires, terminating with red plugs. RESET UNIT (HUMIDIFIERS) To reset the humidifier, the on/off/drain switch at the front of the humidifier should be switched to the off position for a minimum of five seconds and then switched back to the on position. - 5 -

OPTIONAL BLOWER PACK ( BUILT-ON OR REMOTE ) TRANSFORMER ( IF REQUIRED ) 3 A FUSE TWO SPEED SWITCH HIGH LOW FAN RESETABLE THERMODISC ( N.C. ) T FAN RELAY 24 V COIL THERMODISC ( N.O. ) T 81 82 83 84 85 OPTIONAL HUMIDISTAT or JUMPER BLOWER PACK TERMINAL BLOCKS DEDICATED DISCONNECT BY OTHERS S S x x S L3 L2 L1 x GROUND CLAMP G JUMPER OR ON/OFF CONTROLS IN SERIES 8 10 81 82 83 84 85 MOD + - REMOTE FAULT 32 30 61 20 PRI. TERMINAL BLOCK TRANSFORMER 3 PHASE CONNECTION STEP DOWN TRANSFORMER 3 A FUSE MAIN SWITCH 1/3 0N 1/2 1/1 OFF DRAIN 2/6 2/5 2/4 DOOR SWITCH 24 V COIL 24 V COIL DRAIN CONTACTOR(S) FILL 24 V COIL 1 2 3 P4 1 2 P1 1 2 1 2 P3 P5 RL 1 1 P8 5 P2 1 2 3 P6 1 2 3 4 GREEN LAMP YELLOW LAMP CYLINDER SGH HUMIDIFIER w OR w/o OPTIONAL BLOWER PACK ( BUILT-ON OR REMOTE ) WIRING DIAGRAM NO. SGH0001 Rev. C - 7 -

LIMITED WAR RANTY Liebert Corporation (hereinafter collectively referred to as THE COMPANY), warrant for a period of two years from date of shipment, that THE COMPANY s manufactured and assembled products, not otherwise expressly warranted (with the exception of the cylinder) are free from defects in material and workmanship. No warranty is made against corrosion, deterioration, or suitability of substituted materials used as a result of compliance with government regulations. THE COMPANY s obligations and liabilities under this warranty are limited to furnishing replacement parts to the customer, F.O.B. THE COMPANY s factory, providing the defective part(s) is returned freight prepaid by the customer. Parts used for repairs are warranted for the balance of the term of the warranty on the original humidifier or 90 days, whichever is longer. The warranties set forth herein are in lieu of all other warranties expressed or implied by law. No liability whatsoever shall be attached to THE COMPANY until said products have been paid for in full and then said liability shall be limited to the original purchase price for the product. Any further warranty must be in writing, signed by an officer of THE COMPANY. THE COMPANY s limited warranty on accessories, not of Liebert s manufacture, such as controls, humidistats, pumps, etc. is limited to the warranty of the original equipment manufacturer from date of original shipment of humidifier. THE COMPANY makes no warranty and assumes no liability unless the equipment is installed in strict accordance with a copy of the catalog and installation manual in effect at the date of purchase and by a contractor approved by THE COMPANY to install such equipment. THE COMPANY makes no warranty and assumes no liability whatsoever for consequential damage or damage resulting directly from misapplication, incorrect sizing or lack of proper maintenance of the equipment. THE COMPANY retains the right to change the design, specification and performance criteria of its products without notice or obligation.

Model #: Serial #: Cylinder #: Cylinder Last Replaced: MTH/DAY/YR MTH/DAY/YR MTH/DAY/YR LISTED HUMIDIFIER E65185 LIEBERT CORPORATION 1050 Dearborn Drive, P.O. Box 29186 Columbus, Ohio 43229 Tel: (614) 888-0246 Fax: (614) 841-6882 LR-35859