Heating and Drying Product Guide

Similar documents
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

SPECIALIST RENTAL PROVIDER HEATING & HOT WATER PACKAGES

ThermoSorb Desiccant Dryers

Kompressoren. Adsorption Dryer AD

HEAVY DUTY STORAGE GAS

FTQ. Daikin Inverter Ducted Heat Pump

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

MovinCool Office Pro Series. The Portable Spot Cooling Solution

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

Adsorption air dryers ADS 1 215

Natural geothermal energy.

Dehumidification Frequently Asked Questions

LG Electronics AE Company, Commercial Air Conditioning

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

FTXS. Wall Mount Heat Pump or Cooling Only

ECOCIAT. Domestic hot water heat recovery unit

Commercial Gas Furnace Upflow

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Temperature control solutions to help you improve business performance

USER S MANUAL HSC-24A

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Operating Instructions Split System Air Conditioner

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

TWE+TTA TWE+TWA T.R.

Portable Air Conditioner

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools


ECO-AIR AIR CONDITIONING

Glossary of Heating, Ventilation and Air Conditioning Terms

Creating the Ideal Environment for Accelerated Drying Times on Construction and Restoration Projects

MAC-120HE-01 Air-Cooled Chiller

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

Guidelines for Preparing for a Temporary Steam Plant

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

HVAC Processes. Lecture 7

Installation Questions

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Direct Fresh Air Free Cooling of Data Centres

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

ROTEX gas hybrid heat pump. A strong team.

HVAC Systems: Overview

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

Technical data. Danfoss DHP-A

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

IV. Rear Mount System

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Low Cost. Lower Energy Costs. Higher Efficiency.

Refrigerated Air Dryers. Catalogue

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

ENHANCED LABORATORY HVAC SYSTEM

The Complete Air Conditioning Guide

Screw Compressors ESM Fixed Speed & VS Variable Speed

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

PORTABLE AIR CONDITIONER

HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Compressed air systems. How to plan, install and operate. Best Practices for Maintenance Management

Air-Conditioning Buying Guide

Printing and Publishing Energy Savings Guide

How To Buy A Lennox Power System

Technical Specification. Generating Set with Waukesha engine burning natural gas

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

The natural ombination

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

Electric Flow Boiler

Laddomat Charging unit

Drives and motors. A guide to using variable-speed drives and motors in retail environments

WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard

Evaluate, Clean, and Tune Guidance

Energy Efficiency. Energy Efficient Home Cooling:

Glossary of HVAC Terms

Cooling kw Heating kw

GLOBACON 05 HVAC Systems for Cogen

Dehumidifier D 850E. - Instruction manual version 02

XV 95. Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace PUB. NO.

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Daikin Altherma Hybrid Heat Pump

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

IMMERSION MANAGEMENT SERVICE KG

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

clean and quiet dental

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

SECTION MORTUARY REFRIGERATORS

Creating Efficient HVAC Systems

Operation and Installation Manual. Max Series

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Transcription:

Heating and Drying Product Guide

Aggreko engineers have vast experience designing and delivering commercial heating and drying packages across a range of industries. Construction Facilities management Shipping Oil and gas These include the construction, facilities management, shipping and oil and gas sectors - environments where climate and moisture control applications are critical to operational success. Using our extensive range of heaters, dehumidifiers, boilers and supporting power and temperature control fleet, we ll find a solution to your most challenging projects. 01 Product Guide Introduction

Construction and refurbishment We understand that the main goal of a construction or fit-out contractor is to complete projects on time and within budget. We therefore design our heating and drying packages to speed up project completions and prevent delays due to poor weather and ambient conditions. Applications: Curing or drying concrete, screed and building structures, ready for fit-out Maintaining temperatures when fitting specialist flooring Drying paint, coatings or plastering Ceiling tile humidity control Dew point protection for critical electrical installations Moisture ingress protection for hard wood veneers Listed building repair / preservation Construction and refurbishment Product Guide 02

Asset preservation Our climate control packages ensure expensive assets or perishable goods are kept in optimum condition. By controlling moisture and humidity, we ll help reduce the risk of condensation, corrosion and spoilage. From preventing the oxidisation of exposed metals on laid-up ships, to controlling the dew point within sensitive areas of museums we can help! 03 Product Guide Asset preservation

Ship building Our team has years of experience delivering projects using heaters and dehumidifiers to facilitate the painting and coating of vessels. While our dehumidifiers can prevent the rusting of a vessel s surface prior to painting and coating, our heaters can then speed up the drying time. Ship building Product Guide 04

Emergency heating and drying When you experience a disaster, such as a flood or a fire, the Aggreko team is here to help. With 18 local service centres across the UK and Ireland, we ll rapidly mobilise and install our kit 24 hours a day, 365 days a year. We aim to get you back up and running fast. Each year we help hundreds of companies to: Dry out water or flood damaged buildings, eliminating the need to replace and reconstruct. Provide temporary, back-up heating, should their HVAC system fail. Control a building s humidity post fire damage. 05 Product Guide Emergency heating and drying

Product range Contact us now on: T: 03339 205294 Product range Product Guide 06

Electric heaters For both indoor and outdoor applications, our electric heaters will keep your operations running and your projects on track. Our industrial heaters are tough, portable and ideal for either largescale or localised temporary heating applications. 18 kw Electric heater 42 kw Electric heater 45 kw Electric heater Contact us now on: T: 03339 205294 07 Product Guide Electric heaters

18 kw Electric heater The 18 kw electric heater has been designed for applications that require a low noise solution. The heavy duty castor wheels make it ideal for commercial use. It can be switched down to suit a range of requirements and most models include an internal thermostat option. Airflow dry air: 1700 m 3 /h Power supply: 390/415V 3p + E 50 Hz Elec. supply running: 29 A Elec. supply min: 17 A Plug type: 32 A 5 pin Ducting size: 305 mm 700 mm 650 mm 600 mm 35 kg Electric heaters Product Guide 08

42 kw Electric heater The 42 kw heavy duty electric heater is designed for applications that require good airflow over long distances. It is easy to manoeuvre with heavy duty castor wheels, fork pockets and lift eye points. It has a remote thermostatic control if required. Airflow dry air: 7000 m 3 /h Power supply: 415V 3p + E 50 Hz Elec. supply running: 63 A Elec. supply min: 22 A Plug type: 63 A 5 pin Ducting size: 500 mm 1150 mm 740 mm 1110 mm 114 kg 09 Product Guide Electric heaters

45 kw Electric heater This high specification heater incorporates a digital display to control heat levels, allowing for very tight temperature settings. The unit also has heavy duty castor wheels, fork pockets and lift eye points. If required it can be internally or remotely thermostatically controlled. Airflow dry air: 5100 m 3 /h Power supply: 415V 3p + E 50 Hz Elec. supply running: 63 A Elec. supply min: 20 A Plug type: 63 A 5 pin Ducting size: 500 mm 1090 mm 574 mm 1120 mm 150 kg Electric heaters Product Guide 10

Indirect diesel fired heaters Aggreko s Indirect Diesel Fired (IDF) heaters are fully fume-free with no additional moisture. High quality fuel filters provide trouble-free running and all can be run with an external thermostat to save on fuel. 65 kw IDF heater 125 kw IDF heater 200 kw IDF heater 350 kw IDF heater Contact us now on: T: 03339 205294 11 Product Guide IDF heaters

65 kw IDF heater This is the smallest of the IDF range. It is fully fume-free with no additional moisture. Best quality fuel filtering ensures trouble-free running. Its own fuel tank allows for independent use. The heater is dual voltage and can run off 110 and 240 volts. Airflow dry air: 5100 m 3 /h Power supply: 110 / 240 V Elec. supply running: 12 A Elec. supply min: 6 A Plug type: 16 A 4343 CEE FORM Fuel consumption: 1.3 gal/h (5.9 L/h) Fuel tank size: 22 gal (100 L) Ducting size: 500 mm 1600 mm 800 mm 1500 mm 380 kg wet IDF heaters Product Guide 12

125 kw IDF heater This heavy duty heater has a powerful fan, allowing many lengths of flexible ducting. The heater has its own 24 hour running fuel tank allowing for independent use. Airflow dry air: 11250 m 3 /h Power supply: 380/415V 3p N+E 50 Hz Elec. supply max: 10 A Plug type: 32 A 5 pin Fuel consumption: 2.7 gal/h (12.3 L/h) Fuel tank size: 70 gal (318 L) Ducting size: 500 mm 2900 mm 1230 mm 1600 mm 1475 kg wet 13 Product Guide IDF heaters

200 kw IDF heater The 200 kw heater is designed for areas that require a good heat/flow with low background noise. Airflow dry air: 11200 m 3 /h Power supply: 400V 3p N+E 50 Hz Elec. supply max: 7.5 A Plug type: 32 A 5 pin Fuel consumption: 4.2 gal/h (18 L/h) Ducting size: 500 mm 2400 mm 810 mm 1360 mm 605 kg IDF heaters Product Guide 14

350 kw IDF heater The 350 kw heater is the largest of the Aggreko heater fleet. This machine has the latest heat controls and frequency slow-start. It can also be switched down to a lesser heat output if required. High flow and low noise make for an excellent all-round heater. Airflow dry air: 25,000 m 3 /h Power supply: 380/415V 3p N+E 50 Hz Elec. supply max: 20 A Plug type: 32 A 5 pin Fuel consumption: 7.8 gal/h (38 L/h) Ducting size: 500 mm 3800 mm 1200 mm 1890 mm 1100 kg 15 Product Guide IDF heaters

Heat pump chillers Aggreko heat pump chillers can be used for both heating and cooling applications, reducing the equipment footprint should both be required. With the addition of an air handling unit, the heat pumps become efficient space heaters providing fume-free, warm dry air. 100 kw Heat pump chiller 250 kw Heat pump chiller Contact us now on: T: 03339 205294 Heat pump chillers Product Guide 16

100 kw Heat pump chiller The 100 kw refrigeration heat pump can be used if a project has electrical power available and use of open-fire systems is not possible. The heat pump is very energy efficient: for every kw of electrical energy consumed, up to 3 kw of thermal heat can be obtained. Due to the nature of refrigeration heat pumps, special care must be taken when operating the units at sub-zero ambient temperatures, ask an Aggreko representative for advice. Heating capacity: 119 kw (@ 45 C LWT 7 C ambient temperature) Absorbed power: 34 kw Temperature range: 30-50 C Fluid flow: 19 m 3 /h Power supply: 400V 3p 50 Hz 3000 mm 1200 mm 2520 mm 1904 kg 17 Product Guide Heat pump chillers

250 kw Heat pump chiller The 250 kw refrigeration heat pump is ideal for heating applications where electrical power is available, and use of open-fire systems is not possible. The heat pump offers excellent energy efficiency: for every kw of electrical energy used, up to 3 kw of thermal heat can be obtained. Due to the nature of refrigeration heat pumps, special care must be taken when operating the units at sub-zero ambient temperatures, ask an Aggreko representative for advice. Heating capacity: 255 kw (@ 45 C LWT 7 C ambient temperature) Absorbed power: 79 kw Temperature range: 30-50 C Fluid flow: 39 m 3 /h Power supply: 400V 3p 50 Hz 4700 mm 1200 mm 2520 mm 3210 kg Heat pump chillers Product Guide 18

DX air conditioner heat pumps Aggreko s DX air conditioner heat pumps offer high levels of heating, cooling and ventilation from a low electrical input. The compact construction of these self-contained units makes them an ideal solution for applications where space, as well as power input, can be a problem. ACHP80 air conditioner heat pump ACHP160 air conditioner heat pump ACHP350 air conditioner heat pump 19 Product Guide DX air conditioner heat pumps Contact us now on: T: 03339 205294

ACHP80 air conditioner heat pump Our smallest air conditioner heat pump has a highly reliable and practical design, specifically for the rental market. The unit is simple and quick to install, with no pumps, pipes, air handlers or water required for comfort heating or cooling. It has a fully automatic operating mode to maintain the required temperature and standard 20 ducting connections designed to fit with Aggreko s ducting range. Air volume: 7000 m 3 /h Heating capacity @ eurovent conditions: 42 kw Absorbed power: 14 kw Temperature rise: 18 K 2300 mm 1980 mm 1320 mm 950 kg Duct connection in: 1 x 500 mm Duct connection out: 1 x 500 mm Electrical connection: Cee-form 63 A 5p Eurovent conditions: Air inlet 20 C 50% rh Ambient 7 C 86% rh DX air conditioner heat pumps Product Guide 20

ACHP160 air conditioner heat pump Offering heating, cooling and ventilation from one unit, the ACHP160 air conditioner heat pump is very practical when space is limited. The direct expansion (DX) design allows rapid plug and play installation. It has energy efficient compressor units and is ideal where low noise levels are required. Air volume: 15000 m 3 /h Heating capacity @ eurovent conditions: 93 kw Absorbed power: 34 kw Temperature rise: 18 K 3800 mm 2300 mm 1900 mm 2500 kg Duct connection in: 2 x 500 mm Duct connection out: 2 x 500 mm Electrical connection: Cee-form 125 A 5p Eurovent conditions: Air inlet 20 C 50% rh Ambient 7 C 86% rh 21 Product Guide DX air conditioner heat pumps

ACHP350 air conditioner heat pump The largest of our air conditioner heat pump range remains compact and practical in design, ideal for projects where space is restricted. Comfort heating, cooling and ventilation can be achieved very quickly due to its plug and play design. It has a fully automatic operating mode to maintain the required temperature and standard 20 ducting connections designed to fit with Aggreko s ducting range. Air volume: 35000 m 3 /h Heating capacity @ eurovent conditions: 214 kw Absorbed power: 70 kw Temperature rise: 18 K 5800 mm 2232 mm 2605 mm 4900 kg Duct connection in: 2 x 800 mm Duct connection out: 2 x 800 mm Electrical connection: Busbar M12 Eurovent conditions: Air inlet 20 C 50% rh Ambient 7 C 86% rh DX air conditioner heat pumps Product Guide 22

Desiccant dehumidifiers 23 Product Guide Desiccant dehumidifiers Aggreko s desiccant dehumidifiers are a cost-effective way to reduce the effects of moisture damage. The units are discreet (one unit can dry out very large areas) and do not require background heat for them to work. In-built heater controllers ensure maximum performance is maintained all year round and help keep running costs to a minimum. If your site access is tight, then all units can be placed outside. By using flexible ducting, the air can then be directed into a specific area as required. Temperature control accessories are available, including a variety of compatible ducting and remote humidistats that easily incorporate into the package. KT1600 Desiccant dehumidifier KT2000 Desiccant dehumidifier KT7000 Desiccant dehumidifier Contact us now on: T: 03339 205294

KT1600 Desiccant dehumidifier The KT1600 desiccant dehumidifier is a heavy duty machine suitable for many applications. Made of stainless steel, this unit combines smart appearance with excellent performance. Its built-in heater controller ensures maximum efficiency is maintained all year round. Remote humidistat control is available when required. Airflow dry air: 1600 m 3 /h Power supply: 380/415V 3p N+E 50 Hz Plug type: 32 A 5 pin Electrical supply running: 20 A Electrical supply min: 15 A Ducting size dry: 205 mm Ducting size wet: 205 mm Keep dry area approx: 4268 m 3 Dry out area approx: 2845 m 3 1750 mm 710 mm 1520 mm 385 kg Desiccant dehumidifiers Product Guide 24

KT2000 Desiccant dehumidifier The KT2000 desiccant dehumidifier is a heavy duty machine suitable for many applications. Its variable fan speed ensures the exact air flow for optimum performance. An electronically-controlled regeneration heater maintains the user humidity level for maximum energy savings. Remote humidistat control is available when required. Airflow dry air: 1700 / 2000 m³/h Power supply: 380/415V 3p N+E 50 Hz Plug type: 32 A 5 pin Electrical supply running: 26 A Electrical supply min: 15 A Ducting size dry: 205 mm Ducting size wet: 205 mm Keep dry area approx: 5335 m³ Dry out area approx: 3556 m³ 2200 mm 7700 mm 1480 mm 410 kg 25 Product Guide Desiccant dehumidifiers

KT7000 Desiccant dehumidifier The KT7000 desiccant dehumidifier is a heavy duty machine suitable for many applications. Made of stainless steel, this unit combines smart appearance with excellent performance. Its built-in heater controller ensures maximum efficiency all year round. Remote humidistat control is available when required. Airflow dry air: 7000 m 3 /h Power supply: 380/415V 3p N+E 50 Hz Plug type: Hard wired Electrical supply running: 112 A Electrical supply min: 32 A Ducting size dry: 305 mm Ducting size wet: 205 mm Keep dry area approx: 17,566 m 3 Dry out area approx: 11,730 m 3 2200 mm 1200 mm 1650 mm 1100 kg Desiccant dehumidifiers Product Guide 26

Boilers Aggreko s oil-fired mobile boilers offer a self-contained, complete hot water package ready for use across a wide range of applications. They are compact and ideal for spaces with a small footprint. A built-in heat exchanger control valve allows them to quickly and accurately operate within a range of fluid temperatures. With an ability to reach 10 bar, they re suitable for applications within high rise buildings. With the addition of an Aggreko air handling unit, they become an efficient space heater providing fume-free warm dry air. 250 kw Boiler 500 kw Boiler Contact us now on: T: 03339 205294 27 Product Guide Boilers

250 kw Boiler The 250 kw boiler has a small footprint for sites where space is limited. The two stage burner and thermostat allow stable temperature regulation. This boiler is very energy efficient, complying to the latest environmental exhaust legislation. Heating capacity (high/low): 250 / 180 kw Fuel consumption (high/low): 22 / 15 L/h Fluid temperature range: 25-80 C Fluid flow: 11 m³/h Power supply: 230 V 1ph / 50 Hz 3400 mm 1000 mm 1622 mm 1922 kg Boilers Product Guide 28

500 kw Boiler The 500 kw boiler has a small footprint for sites where space is limited. The two stage burner and thermostat allow stable temperature regulation. This boiler is very energy efficient, complying to the latest environmental exhaust legislation. Heating capacity (high/low): 515 / 370 kw Fuel consumption (high/low): 55 / 39 L/h Fluid temperature range: 25-80 C Fluid flow: 22 m³/h Power supply: 400 V 3ph / 50 Hz 3700 mm 1200 mm 1622 mm 2900 kg 29 Product Guide Boilers

Useful conversions Area: 1 m 2 = 10.76 ft 2 1 ft 2 = 0.093 m 2 Temperature: ºC = (ºF-32) x 5/9 ºF = (ºCx9/5) + 32 Air flow: Capacity: Water flow: 1 m 3 /s = 2119 cfm 1000 cfm = 17000 3 /h 1 kg = 2.2046 lb 1 lb = 0.4536 kg 1 L = 0.22 gal 1 gal = 4.546 L 1 L/s = 13.2 g/m 1 g/m = 0.076 L/s Heat: 1 kw = 3412 BTU/h 1000 BTU/h = 0.293 kw 1 Therm = 29.3 kw Refrigeration: 1 kw = 0.284 Ton R 1 Ton R = 3.12 kw Heat transfer: 1 W/m 2 ºC = 0.176BTU/h sqft ºF 1 BTU/h sqft ºF = 5.678 W/m 2 ºC Volume: 1 m 3 = 35.31 ft 3 Linear: 1 ft 3 = 0.0283 m 3 1mm = 0.0394 inch 1 in = 25.4 mm 1 m = 3.28 ft 1 ft = 0.3048 m Velocity: Pressure: Power: 1 m/s = 196.85 ft/min 1000 ft/min = 5.08 m/s 1000 pascals = 100 mm water gauge 1 inch WG = 25mm WG 1 bar = 14.5 psi 1 psi = 0.069 bar 1 kw = 1.34 HP 1 HP = 0.746 kw 1 inch WG = 25mm WG 1 bar = 14.5 psi 1 psi = 0.069 bar Useful conversions Product Guide 30

Head Office Aggreko UK Ltd Aggreko House, Orbital 2, Voyager Drive, Cannock, Staffordshire, WS11 8XP T: 03458 24 7 365 E: hire@aggreko.co.uk Aggreko Ireland Ltd Clonminam Industrial Estate, Portlaoise, Co Laois, Ireland T: ROI - 1890 200 400 T: NI - +353 57 86 63233 E: hire@aggreko.ie Aggreko operates from more than 200 locations throughout the world. For the location nearest you please go to: www.aggreko.com/contact