TECHNICAL DESCRIPTION. SANITARY CABIN (PU - design)

Similar documents
ORAY PREFABRICATED GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS

TARIFF CODE and updates standard

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

ECOCIAT. Domestic hot water heat recovery unit

QUICK BUILD DEMOUNTABLE CONTAINERS & WAREHOUSES. Construct the Quick-Build Container in under 5 minutes!

LOW COST PREFABRICATED CONSTRUCTION SYSTEM

HEAVY DUTY STORAGE GAS

SERVER ROOM CABINET INSTALLATION CONCEPTS

TPM 006/99 Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

20 TANK CONTAINER STANDARD SPECIFICATION MODEL NUMBER: 24 FSTD 2 QUOTATION NUMBER

SOLAR WATER HEATER USER AND INSTALLATION MANUAL

Industrial infrared heater IR For premises with large volumes and high ceilings

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

Energy Company Obligation (ECO): Technical Monitoring Questions

Excerpts from the Canadian National Building Code (NBC)

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

Linkeo 19" freestanding cabinets

UniPlate. Solar Collectors SOLAR SYSTEMS.

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

plumbing products guide

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Building Condition Assessment Report

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Does Wall Township require an inspection by the building department on resale of a home?

MODEL HSR-007 Direct Drive Rolling Steel

Operators manual Basic water heater

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to

SPECIFICATIONS FOR TENDER NO: PSNR/SCP/VKS/E 1635 ANNEXURE I TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST

All Weather Hall. Efficient, multipurpose & quick to build

19 DYNAmax Free Standing Server C A B I N E T s

19 DYNAmax Free Standing Server C A B I N E T s

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

PLEASE REFER TO YOUR INDIVIDUAL QUOTE

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

HERZ-Thermal Actuators

TMS TANK MANAGEMENT SYSTEM

Saferand easierinstallation

Renovation instructions

Modular Access Floor for Data Center. From Rack to Row to Room to Building

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

Asbestos in the home. for you - for your community - not for profit

FIRE RATED GLAZING System Guide

Pre-installation Manual. CONCEPT Processor 305 DW / 405 DW / 505 DW 505 DW XP

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Mark Cramer Inspection Services, Inc.

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

1 DESCRIPTION OF THE APPLIANCE

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

Networking Cabinets > Part No Capacity Available Colors Height(mm) Width(mm) Depth(mm)

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Meaco 30L and Meaco 40L dehumidifier instruction manual

DRUM ROLLER. FAR-1, Article No. B A DRUM CART FOR 200 LITER STEEL DRUMS. Model FK FK FK FK

SERVICE SERVICE MANUAL FOR ALDE ELECTRICAL HEATER

Energy Efficiency in Buildings

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

Installation Instructions

2010 Residential Water Heater Replacement Check List

Aluminium Standard. Technical Data. Included in delivery

Transformer oil cooler ALFA A02

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

HS-Steel-Classic. Curing chambers for the concrete block industry in a proven steel version

Please also see 10 golden rules for correct Saniflo installation on

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Morgue refrigeration unit

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

ENGLISH FORK GUIDE 2013

Linear Luminaire with LED Series EXLUX 6402/2

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza (Spain) Tel.: Fax:

MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

SSG PRODUCTS FOR SHIPS AND OFFSHORE

Services Enclosures and Protected Shafts - Maintaining Compartmentation

BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad

Slides and Drawers. The right collection

DIGITUS Network & Server Cabinets. UNIQUE Series

ABSeam Panel Overview and Installation Instructions

The specialist for mobile space solutions

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

TFSR & TFSK Roof Fans

Superform Products Ltd.

PB301 July Lightweight Building Solutions. Bushfire Protection.

SECTION TABLE OF CONTENTS. H Proposed Material, Product or Equipment Substitution Request

Transcription:

TECHNICAL DESCRIPTION for SANITARY CABIN (PU - design) In General: The following description refers to the specification and design of standard cabins. Our cabins match the ISO-norm dimensions and have therefore many advantages of that system. They consist of a solid frame construction. Dimensions (mm) and weights (kg): Type external internal length width height Length width height weight SU 10 2,989 2,435 2,591 2,815 2,260 2,340 1,490 SU 20 6,055 2,435 2,591 5,880 2,260 2,340 2,490 1.) FLOOR: - frame construction: - cold rolled, welded steel profiles, 3 mm thick - 4 corner casts, welded - 2 fork lift pockets - distance 2,050 mm (alternatively 1,650 mm) (inside clearance of forklift-pockets: 352 x 85 mm) - steel cross members with omega profiles, thickness = 2.5 mm In the area of the water heater double amount of cross members. - insulation: - 60 mm mineral wool slabs (density 16-24 kg/m³) flammability class A - non combustible both in accordance with ÖNORM B 3800 - subfloor: - 0.63 mm thick, galvanised steel sheets - floor: - cement bound chipboard, thickness 22 mm resistant against water, mildew and fungal attack - vinyl knob floor cover, 2 mm thick flammability class B1 - hardly combustible welded seams pulled up 100 mm on the side walls SA_PU_englisch Valid: January 2005 Page 1

2.) ROOF: - frame construction: - cold rolled, welded steel profiles, 3 mm thick - 4 corner casts, welded - wooden cross members l x w = 100 x 40 mm - roof cover: - 0.63 mm thick, galvanised steel sheet double folded joint along the whole cabin length - insulation: 100 mm mineral wool slabs (density 16-24 kg/m³) flammability class A - non combustible both according to ÖNORM B 3800 - ceiling: - 0.63 mm steel sheet RAL 9010 white on 12.5 mm plasterboard - CEE connectors: recessed in frame on short end side 3.) CORNER POSTS: - cold rolled steel profiles, 3 mm thick welded to roof and floor frame 4.) WALL PANELS: - with integrated enforcements in different versions - wall thickness: 60 mm - panel types: - full panel - door panel - sanitary window panel - half panel - external cladding: - corrugated, galvanised and coated steel sheet; 0.6 mm thick colour: blue, white, grey (similar to RAL 5010/9010/7035) - insulation: - 60 mm polyurethane (PU), (density 35-40 kg/m³) - flammability class B2 - internal cladding: - galvanised steel sheet; 0.5 mm thick colour: white 5.) PARTITION WALLS: - wall thickness: 60 mm (optional) - panel types: - full panel - door panel - 60 mm honeycomb cardboard filling - internal cladding: - galvanised steel sheet; 0.63 mm thick colour: white SA_PU_englisch Valid: January 2005 Page 2

6.) DOORS: - external door: - right or left hand hinged - door blade with galvanised steel sheets on both sides, 40 mm insulation - steel frame with triangular wraparound sealing - dimensions: nominal dimensions internal clearance 875 x 2,000 mm 811 x 1,968 mm - internal door: (optional) - right or left hand hinged - door blade with galvanised and coated steel sheets on both sides, 40 mm insulation - steel frame with triangular wraparound sealing - dimensions: nominal dimensions internal clearance 625 x 2,000 mm 561 x 1,968 mm 875 x 2,000 mm 811 x 1,968 mm 7.) WINDOWS: - upvc-windows with insulated obscured glazing and - one hand tilt and turn mechanism; white - window dimensions: 652 x 714 mm ATTENTION: The built-in insulation glass is only suitable for use at altitudes up to 1,100 m above sea level; above 1,100 m pressure compensation must be undertaken. 8.) ELECTRICAL INSTALLATIONS: construction: dampproof concealed cabling - technical data: - recessed CEE external plug and socket connections - voltage 230/400 V - 50/60 Hz, 3/5 poles, 32 A - circuit diagram for assembly provided inside the consumer box - consumer box, surface type, dampproof, single-row - circuit breaker for boiler - residual current operated device 40 A/0.03 A 2/4 poles - circuit breaker 10 A/13 A (light) 2 poles - circuit breaker 13 A (convector heater) 2 poles - circuit breaker 13 A/16 A (sockets) 2 poles - circuit breaker 16 A (boiler) 3 poles - dampproof power sockets - dampproof light switches - 2 twin batten fluorescent light tubes with plastic covering 1 x 36 W - earthing: Earthing conductor of galvanised flat steel and clamp. The protective earthing installation on site must be carried out by the buyer/hirer. SA_PU_englisch Valid: January 2005 Page 3

9.) WATER INSTALLATIONS: - water supply: supply with ¾ or 1 pipe through the cabin wall - internal: PVC piping - warm water supply: with electric boiler size depending on cabin type (80 or 300 litres.) ATTENTION: The boiler with 80/300 litre capacity are designed for a max. working pressure of 6 bar. Higher water pressure will be reduced by a pressure reduction valve! - waste water: The waste water is collected in PVC-pipes DN 50 or DN 100 (external diameter 50 or 110 mm) and discharged through the cabin wall. The buyer/hirer must feed the waste water into an authorised sewage network or sewage tank. 10.) HEATING AND AIRCONDITION: Individual heating by frost heaters, thermostatically controlled electric convector and/or fan heaters with safety switch for overheating. Mechanical air circulation via extract fans! Regular ventilation of the rooms must be provided - a relative humidity of 70 % should not be exceeded! 11.) INSULATION: - floor: thickness = 60 mm U= 0.54 W/m² K - roof: thickness = 100 mm U= 0.37 W/m² K - external wall: thickness = 60 mm polyurethane U= 0.375 W/m² K - sanitary window: thickness = 4/16/4 mm U= 2.10 W/m² K 12.) LOAD BEARING CAPACITY: (single container) - floor: max. load capacity: 2.0 kn/m² (working load) in the area of the boiler: 3.0 kn/m² max. total load: 2.5 kn/m² - roof: max. load capacity: 1.0 kn/m² (snow load) max. total load: 1.5 kn/m² 13.) WIND RESISTANCE: Multi stacked cabins or cabins which are exposed to strong winds must be secured adequately (for example with stacking cones, steel cables, etc.) SA_PU_englisch Valid: January 2005 Page 4

14.) ASSEMBLY / ERECTION: The individual cabins can be positioned side by side, end to end or stacked (in a block) and utilized 3-high according to static calculations. A single cabin (for example a 20' cabin) must be put on either 6 wooden or concrete foundation points. The cabins can also be positioned on concrete strips or concrete slabs. Foundation parameters and frost depths have to be adapted to local soil and ground conditions. Level foundations are a pre-requisite to enable a trouble free assembly and a perfect standing of the whole building. The same applies for the assembly of multi unit buildings. 15.) HANDLING: - with fork lift - with crane: angle between rope and horizontal line at least 60 Due to construction and design, handling with spreader is not allowed. 16.) QUALITY SUPERVISION: Germanischer Lloyd Type test for the 20' office cabin with internal height of 2,340 mm. 17.) PAINT: Physically drying lacquer, high weather and ageing resistance. Resistant against chemicals (industrial atmosphere), lasting elasticity, for ferrous and non-ferrous metal surfaces. - floor: 70 µm PVC primer (corrosion protection) - roof: topcoat in RAL colour - panels with PVC coating: 25 µm paint thickness for standard RAL colours (RAL 5010/9010/7035) - frame: 30-60 µm PVC primer 30-40 µm PVC topcoat We do not give any warranty for production caused colour deviations. The buyer is responsible to ensure that magisterial and legal requirements concerning storage, assembly and use of the cabins are met. Subject to technical alterations. SA_PU_englisch Valid: January 2005 Page 5