Instruction Manual Type K Thermocouple Thermometer

Similar documents
Instruction Manual Temp 4/5/6 Temperature Meter Series

Thermocouple Thermometer Models

Instruction Manual ph 5+ ph 6+ Ion 6+ Technology Made Easy...

ExStik TM ph Waterproof Meters

Thermistor Thermometer MODEL NO

Thermocouple Thermometer

Thermocouple Thermometer

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

Dual Laser InfraRed (IR) Thermometer

INSTRUCTION MANUAL DTH Fax: (503)

Dual Laser InfraRed (IR) Thermometer with Color Alert

Instruction Manual DO 110. Hand-held Dissolved Oxygen Meter with RS 232C. 68X Rev. 0-11/05. Technology Made Easy...

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Dual Laser InfraRed (IR) Thermometer

Electrical Stability Tester, Model 23E Instruction Manual Manual No , Revision B Instrument No

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

Hand-held thermometer Model CTH7000

Instruction Manual HI Refractometer for Refractive Index and Brix Measurements

High Temperature InfraRed Thermometer with Laser Pointer

Leaf River Outdoor Products Vibrashine, Inc. P.O. Box 557 Taylorsville, MS (601) FAX (601)

Microwave Meter. Instruction Manual

RS DIGITAL THERMOMETER

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

Barnant Company THERMOCOUPLE THERMOMETER. Dual J-T-E-K MODEL NO Barnant Company

Automatic Phone-Out Home Monitoring Systems

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Model 349KLX Remote Display Digital Scale User Instructions

FARMEX HT-PRO OPERATING INSTRUCTIONS PORTABLE MOISTURE AND TEMPERATURE TESTER FOR BALED HAY

AutoRanging Digital MultiMeter

User Manual. Humidity-Temperature Chart Recorder. Model RH520

IN-OUT Thermometer with Cable Free Sensor and Clock

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Soil Sensor Reader PRODUCT MANUAL

User's Guide. Digital Viscotesters. Model High Range (0.3 to 4000 dpas) Model Low Range (1.5 to 330 mpas) Introduction

Manual Ranging MultiMeter

Instruction Manual HI Refractometer for Sucrose Measurements

Temperature, Humidity & Dew Point Chart Recorder

Nokia Wireless Keyboard (SU-8W) User Guide

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

4-Channel Thermometer / Datalogger

Hygro-Thermometer + InfraRed Thermometer Model RH101

Kurzweil KORE 64. ROM Expansion Board for the PC3 and PC3K

Periodic Verification System Model 775PVS

User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:

User Guide. Temperature and Humidity Datalogger. Model 42280

Refer to page 6 to page 19 for detailed instructions.

G670 Intermittent Pilot Ignition Controls

Care and use guide. Contents. a handy solution made easy. page

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Portable Waterproof ph/dissolved Oxygen Meter

SINGLE RANGE DS METERS Operation Instructions

Digital Fingerprint safe

DSM155 Digital LED Light Meter User s Manual DSM155

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

Light Meter (Foot Candles)

Wolverine Data PASS Portable Scanner User Manual V1.0

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

EzFlex Combustible Gas Leak Detector Model EZ40

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

ViviCam 25 Digital Camera User s Manual

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Phoenix Body Fat Scale Manual

Optical Power Meter. Specification & User Manual

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Milwaukee USER MANUAL

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

AD-01 Slave Auto Dialer. Owner s Manual

ADVANCED INTERNET DOWNLOADABLE POSTAL & SHIPPING SCALE

PIPELINE INSPECTION COMPANY LTD. Portable Holiday Detectors. OPERATING INSTRUCTIONS SPY PORTABLE HOLIDAY DETECTORS Models 780, 785, & 790

Wireless Alarm System. Wireless Keypad. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

Care and use guide. Contents. page

K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)

OPERATING INSTRUCTIONS

CAD-05 Kit GSM Auto Dialer. Owner s Manual

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

TRIMBLE TX5 3D LASER SCANNER QUICK START GUIDE

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Your Simple Guide to Battery. Replacement. Customer Care:

Electric Water Kettle

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

Care and use guide. Contents. a handy solution made easy. page

100 Series Maxi Internal Filters. Instruction Manual

E&P HYDRAULICS Remote control EPRC-01 Level System Camper

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

User s Manual. Bluetooth Calculator Keypad. Page

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

DCX300 - DCX400 - DCX600

USER S MANUAL HSC-24A

Troubleshooting Salt Generators

EK908FHL - Thermostat for floor heating

Ground Resistance Clamp-On Tester

ROTOR LOADER OWNER S MANUAL

Transcription:

Type K Thermocouple Thermometer Technology Made Easy... 68X243624 Rev. 0 02/04

Preface This manual serves to explain the use of the Digi-Sense Type K thermocouple thermometer. This manual functions in two ways: first, as a step by step guide to help you operate the meter; second, it serves as a handy reference guide. This manual is written to cover as many anticipated applications of the Type K meter as possible. If there are doubts in the use of the Type K meter, do not hesitate to contact the nearest Eutech Instruments/ Oakton Instruments Authorized Distributor. Eutech Instruments/ Oakton Instruments will not accept any responsibility for damage or malfunction to the meter caused by improper use of the instrument. The information presented in this manual is subjected to change without notice as improvements are made, and does not represent a commitment on the part of Eutech Instruments Pte Ltd/ Oakton Instruments. Copyright 2004 Eutech Instruments Pte Ltd/ Oakton Instruments Rev 0, 02/04.

Table of Contents 1. INTRODUCTION 1 2. GETTING STARTED 2 2.1 Description of Keypad Functions 2 2.2 Description of LCD Annunciators 2 2.3 Inserting & Removing the Rubber Boot / Stand (Optional Purchase) 3 2.4 Inserting New Batteries 3 2.5 Battery Replacement 4 2.6 Connecting the Temperature Sensor 4 2.7 Switching the Meter On 4 3. CALIBRATION 5 3.1 Temperature Calibration 5 4. MEASUREMENT 7 4.1 Taking Measurements 7 4.2 Holding a Reading 7 4.3 Releasing a Held Reading 7 5. PROBE CARE AND MAINTENANCE 8 6. TROUBLESHOOTING 8 7. SPECIFICATIONS 9 8. ACCESSORIES 10 9. WARRANTY 11 10. RETURN OF ITEMS 12

1. INTRODUCTION Thank you for purchasing the Digi-Sense Type K thermocouple thermometer. This economical microprocessor-based handheld meter works with any type K probe with color-coded yellow ANSI miniconnectors. Type K probes (chromel-alumel) offer a wide temperature range from 250 to 1372 C / 418 to 2502 F; suitable for use in oxidizing environments The meter features: Large LCD for clear and easy reading Readings in o C and o F (selectable) Low battery indicator Hold function, freezes measured reading User calibration - offset adjustment Built-in non volatile memory to ensure that calibration and other information are not erased if battery is disconnected This instruction manual is organized for quick reference with step-by-step procedures that give you thorough review of the various features and meter operations. Included with your meter are 4 alkaline AAA batteries and an instruction manual. To order Type K thermocouple probes, please refer to Section on Accessories for more information. 1

2. GETTING STARTED 2.1 Description of Keypad Functions The meter has three keys on its splash-proof keypad. These keys include ON / OFF, HOLD, and o C/ o F keys. ON/OFF o C/ o F HOLD/ENTER Powers meter on and shuts the unit off. Meter directly enters measurement mode when you turn it on. Switches between o C and o F measurement mode Activates the calibration mode when used with the ON/OFF key. Decrease the calibration value during the calibration mode. Freezes the measured reading. Confirm calibration value Increase the calibration value during the calibration mode. Figure 1: Keypad 2.2 Description of LCD Annunciators The Digi-Sense Type K meter has a large custom LCD that consists of 4-digit segments and operation annunciators for o C and o F. Other indicators include HO (when the HOLD function is activated), LO (low battery condition) and K (Type K thermocouple thermometer). K HO LO C F Figure 2: LCD Segment 2

2.3 Inserting & Removing the Rubber Boot / Stand (Optional Purchase) 1. To remove meter from rubber boot, push out from the bottom edges of meter until it is completely out of boot. Ensure that the connector of temperature sensor is not connected. 2. To insert meter into rubber boot, slide in from the top of meter before pushing the bottom edges of meter down to set it into position. Lift up the stand at the back of meter for bench top applications if necessary. 2.4 Inserting New Batteries Figure 3: Inserting meter into the rubber boot The battery compartment is found at the back of instrument. To open the battery compartment, push in the direction of arrow and lift up the cover. Note the polarity of battery before inserting into position. After replacement, place cover back and press down until it locks tight. Figure 4: Battery compartment at the back of the meter 3

2.5 Battery Replacement A LO annunciator in the LCD alerts you when battery power is running low. Replace with the same type as recommended by the manufacturer. K LO o C Figure 5: Low battery indicator Caution: Power off the meter when changing battery. 2.6 Connecting the Temperature Sensor Insert the yellow 2-pin mini connector plug of the temperature sensor into the connector socket on the side of the meter. NOTE: The negative pin is larger than the positive pin, be sure to properly align the pins. Remove sensor from meter for long periods of non use. Figure 6: Connecting the temperature sensor 2.7 Switching the Meter On 1. Press ON/OFF key to power up your meter. The meter will momentarily display its revision number and the whole LCD segments before switching to the measurement mode. Figure 7: "Open" annunciator 2. The LCD displays open if the temperature sensor is faulty, or there is an open circuit, i.e. no sensor is attached. Please refer to section on Troubleshooting if in doubt. 4

3. CALIBRATION 3.1 Temperature Calibration Your meter is factory calibrated. The meter allows you to enter a 1-point calibration as fine adjustment by changing its offset value. This is useful when using a new probe for the first time. 1. Connect the temperature probe and switch on the meter. 2. Dip the probe in a constant temperature bath, or in liquid whose temperature can be checked against another accurate thermometer. For best accuracy, place your thermocouple probe and the reference thermometer in a constant temperature bath. 3. Note the reading. Power off the meter once the reading has stabilized. 4. With the meter powered off, hold down C/ F key and press ON/OFF key to power up the meter. 5. Continue to hold down C/ F key until display shows CA momentarily. This is followed by a blinking value which is with respect to the factory default calibration. 6. To adjust the display until it matches the correct temperature: - Press C/ F key to decrease - Press HOLD key to increase Press C/ F key to decrease value With meter off, Hold down C/ F key and press ON/OFF to power on the meter. Continue hold down C/ F until display shows CA momentarily. ON OFF C F C F HOLD C Press HOLD key to increase value C To confirm value, wait 5 seconds. CO = confirms temperature calibration C Back to measurement Figure 9: Calibration Sequence 5

7. To confirm value, wait for 5 seconds without any key press. The CO display appears signifying conformation and meter goes back to the measurement mode. 8. To abort calibration, press ON/OFF key to power off the meter. NOTE: The offset adjustment window is ±10 C (±18 F) of the factory default value. 6

4. MEASUREMENT 4.1 Taking Measurements K C 1. The meter automatically enters Temperature mode when powered on. The K annunciator will be displayed. 2. The o C or o F annunciator displayed in your LCD indicates which mode you are taking measurements in. 3. Press the C/ F key to toggle between temperature units. 4.2 Holding a Reading To freeze or hold your reading, press HOLD key once. The LCD displays HO annunciator to indicate the HOLD function is activated. K HO o F 4.3 Releasing a Held Reading Press HOLD key again to deactivate HOLD function or to release your frozen reading. The meter returns to measurement mode, and the HO annunciator disappears from the LCD. 7

5. PROBE CARE AND MAINTENANCE For best results, maintain the thermocouple probe as per the manufacturers instructions. To remove the probe, simply hold firmly onto the plastic yellow mini-connector and pull out of the meter s socket. Store both the probe and meter into its original packaging when not in use. 6. TROUBLESHOOTING Problem Cause Solution No display when turned on. open display on LCD a) Batteries not in place. a) Re-insert batteries in correct polarity. a) Probe not connected a) Make sure probe is firmly connected or is not damaged. Ur or Or display on LCD a) Measurement over (Or) or Under (Ur) range a) Ensure temperature taken is within meter s specification. LO annunicator in the LCD a) Low battery a) Replace batteries with fresh ones. Inaccurate readings Unstable reading a) Wrong thermocouple probe type used b) Reading has not stabilized c) Temperature calibration not correct or new probe used a) Electrode not deep enough in sample b) Dirty connector c) Broken probe d) External noises or induction caused by nearby electrical motor Slow response a) Dirty probe a) Clean probe a) Verify that Type K probe is used. b) Check time constant of probe & wait for reading to stabilize c) Recalibrate a) Place probe deeper in sample. b) Clean probe connector. c) Replace electrode. d) Remove or switch off interfering motor. 8

7. SPECIFICATIONS Temperature Range Type K Resolution t<-99.0 C -99.9 C<t<299.9 C t>299.9 C Accuracy t<-99.9 C t>-99.9 C Offset Adjustment Window Auto Power-Off Hold Function Display Low Battery Indicator Input Power Requirement Battery Life Operating Temperature Dimension / Weight -250 to 1372 C (-418 to 2501 F) 1 C (1 F) 0.1 C (0.1 F) 1 C (1 F) ± 0.25% of reading + 1 C (2 F) ±0.25% of reading + 0.5 C (0.9 F) ±10 C (±18 F) 17 minutes after last key-press Yes Custom LCD Yes 2-pin ANSI mini connector 4 AAA Batteries >400 hours continuous operation 0 to +50 C (32 to 122 F) Meter: 14 x 7 x 3.5 cm / 200 g Boxed: 24 x 17 x 8 cm / 550 g 9

8. ACCESSORIES Item Description Eutech Instruments Ordering Code Oakton Instruments Ordering Code Digi-Sense Type K Thermocouple Thermometer Type K general purpose probe (immersion into liquids), 5-ft coiled cable. Type K penetration probe (meat, semi-soft materials), 5-ft coiled cable. Type K surface probe (direct contact on hot surface, no liquids), 5-ft coiled cable. Type K alligator clip-on surface probe, 2, (electronics, tubing, no liquids), 5-ft coiled cable. 93000-00 93000-00 EC-TPGLPK-01M 08516-55 EC-TPPENK-01M 08516-65 EC-TPSURK-01M 08516-60 EC-TPCLPK-01M 08469-02 Rubber Boot / Stand EC-RUBBERBOOTTC 35627-80 Replacement AAA Batteries 60X023200 09376-00 10

9. WARRANTY This meter is supplied with a warranty against significant deviations in material and workmanship for a period of THREE years from date of purchase. If repair or adjustment is necessary and has not been the result of abuse or misuse within the designated period, please return freight pre-paid and correction will be made without charge. Eutech Instruments/ Oakton Instruments will determine if the product problem is due to deviations or customer misuse. Out of warranty products will be repaired on a charged basis. Exclusions The warranty on your instrument shall not apply to defects resulting from: Improper or inadequate maintenance by customer Unauthorized modification or misuse Operation outside of the environment specifications of the product 11

10. RETURN OF ITEMS Authorization must be obtained from our Customer Service Department or authorized distributor before returning items for any reason. A Return Goods Authorization (RGA) form is available through our authorized distributor. Please include data regarding the reason the items are to be returned. For your protection, items must be carefully packed to prevent damage in shipment and insured against possible damage or loss. Eutech Instruments/ Oakton Instruments will not be responsible for damage resulting from careless or insufficient packing. A restocking charge will be made on all unauthorized returns. NOTE: Eutech Instruments Pte Ltd/ Oakton Instruments reserves the right to make improvements in design, construction, and appearance of products without notice. 12

For more information on Eutech Instruments/ Oakton Instruments products, contact your nearest distributor or visit our website listed below: Oakton Instruments P.O Box 5136, Vernon Hills, IL 60061, USA Tel: (1) 888-462-5866 Fax: (1) 847-247-2984 E-mail: info@4oakton.com Web-sites: www.4oakton.com www.oaktoninstruments.com Eutech Instruments Pte Ltd. Blk 55, Ayer Rajah Crescent, #04-16/24 Singapore 139949 Tel: (65) 6778 6876 Fax: (65) 6773 0836 E-mail: marketing@eutechinst.com Web-site: www.eutechinst.com Distributed by: