DMA-1 Direct Mercury Analyzer

FMA-80 Fluorescence Mercury Analyzer

DMA-80 Direct Mercury Analyzer

MILESTONE START D. Microwave Digestion System

M I C R O W A V E O P E N V E S S E L D I G E S T I O N S Y S T E M T HE NEW MIL E STO NE MILESTONE

Milestone Warranty. ETHOS One. The Best Choice in Microwave Sample Preparation MILESTONE

MILESTONE. RotoSYNTH. Rotative Solid-Phase Microwave Reactor

MILESTONE. SynthWAVE. The Game Changer in Microwave Synthesis

Mercury Determination in House Dust, NIST SRM-2584, USEPA Method 7473, Using the Teledyne Leeman Labs Hydra II C Combustion CVAAS

MILESTONE. MicroSYNTH. Microwave Synthesis Labstation

MILESTONE CLEAN CHEMISTRY LINE DUOPUR TRACECLEAN ULTRA-TRACE INSERTS. A Breakthrough in Reduction and Control of the Analytical Blank MILESTONE

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

Phoenix Apollo Laboratory TOC Analyzers and Services Designed To Meet Your Needs

FP628. Nitrogen / Protein Determination by Combustion. Rev 1-6/8/11

M I C R O W A V E E X T R A C T I O N S Y S T E M THE NEW MILESTONE MILESTONE

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

The art of elemental analysis

ORGANIC SAMPLE PREPARATION

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

The Sievers 900 Series TOC Analyzers

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems

Accurate Determination of Lead in Different Dairy Products by Graphite Furnace Atomic Absorption Spectrometry

Nitrogen analysis is elementary

MILESTONE. NEOS Rapid, Solvent-Free Microwave Extraction (SFME) of Essential Oil The Microwave Clevenger TM

A fully quantitative research method for the analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS

Assessing the Changes Required by the Industrial Boiler MACT Regulations

UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850

DETERMINATION OF TOTAL CARBON, TOTAL ORGANIC CARBON AND INORGANIC CARBON IN SEDIMENTS

SCION SQ Series GC-MS

Elemental analyzer multi EA 5000

Halogen Free: What, Why and How. Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc.

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

How To Test For Contamination In Large Volume Water

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

Multi-elemental determination of gasoline using Agilent 5100 ICP-OES with oxygen injection and a temperature controlled spray chamber

UVC LEDs for. Environmental Monitoring

STANDARD CLEANING AND CALIBRATION PROCEDURE FOR TGA-50(H) AND TGA-51(H)

Amino Acid Analyzer L-8900

limit to percentage levels, a limited working range translates

Nu G Medical Waste System Technology (Pyrolysis / Thermal Decomposition)

Elemental Analyses by ICP-AES

Quality Assurance for the Analysis of Steel by Gas Component Analysis

TRL-onlineTOC Monitor is designed for monitoring carbon content in

DSC Differential Scanning Calorimeter

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

NITRIC OXIDE and NITROGEN DIOXIDE 6014

4.2 Bias, Standards and Standardization

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Pore size and BET surface area. analysis at your fingertips. SA Gas Adsorption Analyzer

Modern approaches to determination of toxic metals in marine environmental objects. Atomic absorption and inductively coupled plasma, advantages and

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Certificate of Analysis

Appendix 5 Overview of requirements in English

Innovative Technology Verification Report

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

Advanced Solutions for Gas Monitoring

Brewery Wastewater: 2010 Water and Wastewater Conference Page 1

GUIDELINES FOR LEACHATE CONTROL

Bridging the analytical gap

73 Series Spectrophotometers

Colorimetric Determination of Iron in Vitamin Tablets

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

2nd IEA Oxyfuel Combustion Conference

When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task.

Physical & Chemical Properties. Properties

OLIVÉR BÁNHIDI 1. Introduction

Department of Environmental Engineering

Car and commercial cial air conditioning service solutions

German engineering under high pressure

Thermo Scientific ConFlo IV Universal Interface

Austin Peay State University Department of Chemistry CHEM Empirical Formula of a Compound

MATHESON REFINERY PROGRAM for Specialty Gas Supply. Experience the MATHESON Commitment to Supply Chain Excellence

Sample preparation for X-ray fluorescence analysis

RECOMMENDED SPECIFICATION. Cogent Environmental OVA-5000 Heavy Metal Analyzer. to Monitor Total Dissolved Arsenic. for

HFM Heat Flow Meter Thermal Conductivity Analyzer

Hazardous Waste Procedures. Faculty of Science University of Ottawa

Heavy Metal Analysis for the Toy Industry by Inductively Coupled Plasma Optical Emission Spectroscopy

Assignment 8: Comparison of gasification, pyrolysis and combustion

Determination of Total Suspended Solids (TSS) and Total Volatile Solids (TVS) in Waters of Fresh/Estuarine/Coastal Waters

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

SO 3 -Monitoring in Flue Gas of a Power Plant Application & Results

LC-MS/MS, the new reference method for mycotoxin analysis

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Flow Injection Analysis

Hellma. Where precision becomes an art. Calibration standards for spectrophotometers by Hellma

Fields of Application / Industry:

El Paso Water Utilities Public Service Board. Application for Renewal Industrial Wastewater Discharge Permit

Ecological Aspects of Oil Shale Processing

Calibration Certificate

Tracer Detection Systems

SODIUM CARBOXYMETHYL CELLULOSE

ß-CYCLODEXTRIN SYNONYMS

Gas emission measurements with a FTIR gas analyzer - verification of the analysis method Kari Pieniniemi 1 * and Ulla Lassi 1, 2

Managing Floor Drains and Flammable Traps

LACHAT METHOD NUMBER D Rev 1, 21 March 2011 SCOPE AND APPLICATION Approximately g CN/L g CN/L. 09e

Exhibit A - Scope of Work

MB3600-HP12 / Measurement & Analytics. Laboratory FT-NIR Heavy Oils Analyzer Crude oil, fuel oil, heavy oil upgrader unit feeds

Transcription:

MILESTONE H E L P I N G C H E M I S T S

8 good reasons to choose the Milestone DMA-80 1. No sample preparation The DMA-80 does not require any sample preparation or other wet chemistry prior the analysis. This means ease of use, low running cost and no need for hazardous chemicals to purchase, handle and dispose. 2. Best analytical performance Combining an innovative mercury measuring system with a unique optical path spectrophotometer, the DMA-80 achieves a detection limit as low as 0,001 nanograms of mercury and is capable of measuring up to 30.000 nanograms of mercury, equivalent to a concentration of 300 mg/kg (300 ppm) on a 100 mg sample analysis. ˆ1=1.2722 W 0.5 =4.10s ˆ2=0.1611 Typical DMA-80 Dual Cell absorbance profile. The 1 st peak is related to the more sensitive longer cell, while the 2 nd peak corresponds to the shorter cell. W 0.5 =5.55s 0204 06 08 10 12 14 16 18 20 22 24 26 28 30 32 34 36 Time [s] 3. Ease of use Just weigh your sample, load it onto the built-in auto-sampler and press start. The DMA-80 is so simple to use that it can be operated in the field, not only in the analytical laboratory. 4. High productivity The DMA-80 is incredibly fast. A complete analysis -start to finish, takes 5 minutes. Sample weight is automatically transferred from the analytical balance. The dual-tray auto-sampler allows sample loading on-the-fly, for a continuous operation of the instrument.

5. Lowest cost of analysis Ease of use, speed of analysis, catalyst and amalgamator long lifetime, sample boats durability and the possibility of using air as combustion and carrier gas minimize the DMA-80 cost of analysis. 6. Easy maintenance All the DMA-80 components, such as the catalytic furnace, amalgamator and spectrophotometer, are easily accessible for routine cleaning and maintenance. 7. Largest installed base With over 1300 units installed in 80 different Countries worldwide, Milestone is the acknowledged market leader in direct mercury determination. Our extensive experience enables us to provide the highest level of application and service support. 8. Official methods compliance The DMA-80 has been used to develop the US EPA method 7473 (Mercury in solids and solutions by thermal decomposition, amalgamation, and atomic absorption spectrophotometry). It is furthermore compliant with ASTM method D-6722-01 (Total mercury in coal and coal combustion residues) and ASTM method D-7623-10 (Total mercury in crude oil).

Milestone DMA-80 The Milestone DMA-80 is a direct mercury analyzer of solid, liquid, and gas samples. Analysis time is 5 minutes only and no sample preparation is required. The DMA-80 is based on the principles of sample thermal decomposition, mercury amalgamation and atomic absorption detection. With over 1300 units installed in 80 different Countries worldwide, the DMA-80 is the most successful direct mercury analyzer in the market. The sample is weighed into a quartz or metal boat, and its weight automatically transferred from the analytical balance to the DMA-80. Sample boats are loaded on-the-fly onto the instrument auto-sampler. Samples are dried and then thermally decomposed in an oxygen-rich stream. Mercury and other combustion products are released and flown through the catalyst, where all interfering substances, such as halogens and nitrogen or sulfur oxides, are eliminated. Mercury is selectively trapped by gold amalgamation, while other combustion by-products are flushed off. The amalgamation furnace is heated and mercury is rapidly released. Mercury is finally carried into multiple measuring cells positioned along the optical path of the spectrophotometer, and quantitatively measured by atomic absorption at 253,65 nm.

DMA-80 user interface The DMA-80 is operated via a compact control terminal with easy-to-read, bright, full-color, touch screen display or, alternatively, by a Windows-based computer. The terminal is provided with multiple USB and RS-232 ports for direct printouts of methods and runs, and for interfacing the instrument to an external balance. The terminal runs Milestone s unique EasyCONTROL software, providing simple and intuitive, but extremely flexible and powerful control over the analytical process. All sample parameters, including furnace temperatures, method profiles, absorbance signals, results, and calibrations are saved. They can be viewed, easily transferred using a USB memory stick or integrated to LIMS Laboratory Information Management Systems. EasyCONTROL software includes the unique AutoBLANK feature. If, following the analysis of a sample with a very high mercury content, the pre-set blank level is exceeded; EasyCONTROL will automatically run blank cycles until the pre-set blank level is achieved. EasyCONTROL allows the operator to designate certain samples as reference, or QC samples. Once a sample is designated as a reference, a known concentration value is entered. If the analysis of that sample yields a concentration outside the acceptable range specified by the operator, EasyCONTROL can be pre-set to either continue, stop, or pause the analysis of the remaining samples. EasyCONTROL software is fully compliant with FDA regulations 21 CFR Part 11.

Milestone DMA-80 analytical performance Accuracy The DMA-80 produces accurate results over a wide dynamic range and on a variety of different matrices. The results below refer to analyses on solid certified reference materials with a mercury concentration ranging from 5 μg/kg to over 25 mg/kg. Sample Certified (μg/kg) DMA-80 (μg/kg) NIST 1568a Rice Flour 5,8 ± 0,5 5,9 ± 0,2 BCR-150 Skim Milk Powder 7,7-11,1 9,2 ± 0,2 NIST 1630a Coal 93,8 ± 3,7 93,4 ± 2,4 NIST 1633b Fly Ash 141 ± 19 149 ± 2 BCR-61 Aquatic Plant 210-250 221 ± 3 GSD-10 Stream Sediment 280 ± 40 270 ± 15 BCR-422 Cod Muscle 543-575 558 ± 8 IAEA-086 Human Hair 534-612 574 ± 12 NIST 2711 Soil 6.250 ± 190 6.240 ± 70 BCR-680 Polyethylene 24,3-26,3 mg/kg 25,8 ± 0,5 mg/kg Sample amount Up to 1,5 grams of solid or 1,5 ml of liquids can be analyzed. This is particularly important for the analysis of heterogeneous materials or for samples with a very low mercury concentration. Precision The DMA-80 provides reproducible results over a broad range of samples, such as polymers, food and feed, and biologicals for instance. Tuna fish average=235 sd=5 RSD=2,2% Hg concentration 265 250 235 220 205 190 175 1 2 3 4 5 6 Run

Sample matrix The DMA-80 produces matrixindependent results.the instrument is calibrated with aqueous standards and analyzes organic and inorganic solid samples. Just one method is used to analyze different matrices making the DMA-80 extremely easy to use. 10 ng of mercury from aqueous mercury standard, NIST 2709 Soil and NIST 1632c Coal, generate the same absorbance peaks. ˆ1=0.5168 ˆ1=0.5271 ˆ1=0.5009 W 0.5 =3.85s W 0.5 =3.90s W 0.5 =3.85s 10 ng of mercury from aqueous mercury standard (left), NIST 2709 Soil (center) and NIST 1632c Coal (right). Memory effect The DMA-80 does not virtually suffer from any memory effect. The instrument software features the Autoblank function, by which the user preset a satisfactory blank level. If that level is exceed the instrument automatically runs blank cycles until the expected level is reached. This is important when analyzing a series of unknown samples. Stability Results are stable over time. The calibration lasts for months of operation. Here is an example on a certified reference material, NIST 2781 Domestic Sludge, which has a mercury content of 3.640 ± 250. 4.500 4.000 3.500 3.000 µg/kg 01 02 03 04 06 07 08 09 10 11 13 14 15 16 17 18 20 21 22 23 24 25 27 28 29 30 31 Mon Tue Wed Thu Fri Sat Mon Tue Wed Thu Fri Sat Mon Tue Wed Thu Fri Sat Mon Tue Wed Thu Fri Sat Mon Tue Wed

Gas analysis Sorbent Traps Sample the gas, through a dedicated mass flow controller, using the Sorbent Traps, and load them onto the autosampler. Total mercury (elemental and oxidized forms) is quantitatively measured in 5 minutes. Sorbent Traps are reusable and extremely easy to use. UNI EN ISO 9001: 2008 CERTIFIED MILESTONE H E L P I N G C H E M I S T S MILESTONE Srl Via Fatebenefratelli, 1/5-24010 Sorisole (BG) - Italy Tel: +39 035 573857 - Fax: +39 035 575498 www.milestonesrl.com - email: analytical@milestonesrl.com MILESTONE INC. 25 Controls Drive - Shelton, CT 06484 - USA Tel: (203) 925-4240 - Toll-free: (866) 995-5100 - Fax: (203) 925-4241 www.milestonesci.com - email: mwave@milestonesci.com Gas Sampling kit Samples are introduced using either a syringe or from a gas sampling bag. The Gas Sampling Kit includes an injection block for sampled delivery and a vacuum pump, which pulls the injected gas through the analyzer. Applications include mercury determination in natural gas, biogas, gas processing etc. as well as in the environmental field (workplace monitoring, mercury spills screening). Major benefits are: fast analysis (3 minutes per sample), wide dynamic range (0,01 to 1.500 µg/m 3 ) and ease of use. MILESTONE GENERAL K.K. KSP, 3-2-1, Sakado - Takatsu-Ku, Kawasaki 213-0012 - Japan Tel: +81 (0)44 850 3811 - Fax: +81 (0)44 819 3036 www.milestone-general.com - email: info@milestone-general.com MLS GmbH Auenweg 37 D-88299 Leutkirch im Allgau - Germany Tel: +49 (0)7561 9818-0 - Fax: +49 (0)7561 9818-12 www.mls-mikrowellen.de - email: mws@mls-mikrowellen.de In Your Country: CAT261EN-002