Mobile Generator MMG35FH Specifications

Similar documents
Magnum Mobile Generator MMG55 Specifications

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Diesel Engine Driven Generators Page 1 of 6

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

DIESEL GENERATOR SETS

APS100 Rental Generator Set Specification

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Spark-ignited generator set

Diesel Generating Set

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

Atlas Copco Generators

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT kva / ekw

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.

PUMP MAINTENANCE SCHEDULE AND CHECKLISTS

Industrial Generator Set Accessories

Industrial Generator Set Accessories

TMS TANK MANAGEMENT SYSTEM

Annex-A TECHNICAL SPECIFICATION

General Dimensions and Weights - Non Loader

WHOLESALE DIRECT INC WEST 65TH STREET

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 10 kw 12.

Technical Specification. Generating Set with Waukesha engine burning natural gas

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

Generator DoCKInG StatIonS

Power Generation. Power Control PCL System Generator Set Control

GENERATOR TRANSFER SWITCH

The kva RAnge

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

Oil and Coolant Circulating Heating System. Model - OCSM

PEACH PACKAGED ELECTRIC AIR CONDITIONING & HEATING PATENT PENDING FIRST RESPONDER EMERGENCY EQUIPMENT

Marine Generating Sets 3.7 to 50 kva

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

How To Use A Cat Diesel Engine

GENERATOR SET, DIESEL ENGINE, MODEL MEP-903A

C18 ACERT Fire Pump Tier bkw/ rpm

OPTIONAL FEATURES 30

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

Frequently Asked Questions Generators

Auxiliary Power Unit (APU) for Military Vehicles

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Industrial Generator Set Accessories

Generator Parts List. GXi Part Number. Model Year. 5650,5650EL, 6500, 6500EL, 4550 Pro, 7550EL Pro DEK, STANLEY

Midwest Industrial Tanks

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

Utility Distribution Systems

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) rpm

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

Emergency Voice Communication Systems EVCS Network 8 Data Sheet

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Commercial Electric Water Heater

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater.

Industrial Generator Set Accessories

Industrial Generator Set Accessories

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

Product Specification instalert Rapid Messenger Variable Message Sign

Industrial Generator Set Accessories

Technical data. Danfoss DHP-A

Mini Hydraulic Excavator

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

A/C-HEATER SYSTEM - AUTOMATIC

JCB MIDI EXCAVATOR 8040 ZTS / 8045 ZTS

Uninterruptible Power Supply

Photovoltaic Solar Energy Unit EESFB

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Industrial Generator Set Accessories

The Yachtmans Choice...

How To Control A Power Command Powerplant

Diesel Generator Set Model DFHC 60 Hz

HM-W536 Install Guide

SIOUX HYBRID WATER HEATER

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Diesel Generator Set Model DGDK 60 Hz

Rotary screw compressors kw 5,5 7, , bar MODULO

The CLIPPER Solutions

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

VoCALL - CFVCM/CFVCWM & CFVCX8. Fire Telephone & Disabled Refuge Network System. User Manual & Log Book

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

START A REVOLUTION! THE NEW SULLAIR 185 PORTABLE AIR COMPRESSOR.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Transcription:

Mobile Generator MMG35FH Specifications ENGINE John Deere PE4024TF281 - turbocharged, diesel engine o Prime - 43 hp @ 1800 rpm o Standby - 48 hp @ 1800 rpm o 4 cylinder o 2.4 L displacement o Tier IV Interim approved Steel, single wall fuel tank o 106 gal. capacity o 95 useable gallons o 36.9 hr. run time full load o Fuel tank built into skid of generator set Fuel consumption at prime: o 100% - 2.6 gph (9.8 Lph) o 75% - 2.0 gph (7.6 Lph) o 50% - 1.3 gph (4.9 Lph) Cooling system capable of operating at 120 F ambient Low coolant shutdown Radiator and oil drains plumbed to exterior Rubber vibration dampers isolate engine/generator from frame Disposable air filter - paper element Air filter restriction indicator mounted on control panel 60 Hz engine/generator Electronic isochronous governing www m-p-llc com Trailer sold separately 35 GENERATOR Marathon Electric o Brushless o 4 pole o Class H insulation Voltage regulation +/- 1% with Marathon SE350 Voltage Regulator SYSTEM OUTPUT 3 position selector switch o Single phase 120 / 240V Zig Zag o Three phase 120 / 208V Low Wye o Three phase 277 / 480V High Wye 26 kw / 26 kva standby, single phase 25 kw / 25 kva prime, single phase 29 kw / 36 kva standby, three phase 26 kw / 33 kva prime, three phase SYSTEM CONTROLS Microprocessor-based controller o Backlit, 128x64 pixel resolution display o -40 F to 185 F operating temperature range o Thermostatically controlled LCD heater Phone: 800-926-9768 Fax: 920-361-2214 ww.m-p-llc.com Page 1 of 5

o Six LED indicators w/ lamp test Alarm / Fault (Red) Ready / Manual (Red) Running (Green) Warning (Yellow) Ready / Auto (Green) Supplying Load (Green) Push buttons for easy operation o Manual or Auto Start o Engine Start or Stop o Alarm Cancel & Fault Reset o Scrolling Arrows for Diagnostic Information System kw output display Line output & frequency display Engine diagnostic display Oil pressure Engine temperature Fuel level Battery System hours Running hours kw hours Time to service o Alarm list warnings / shutdowns are date & time stamped Fuel level: warning 15%; shutdown 5% Overspeed protection: shutdown 115% Oil pressure: warning 25 psi; shutdown 20 psi Coolant temperature: warning 220 F; shutdown 230 F Battery voltage: over 15VDC; under 11VDC Generator over voltage: warning 110%; shutdown 111% Generator under voltage: warning 87%; shutdown 86% Generator over frequency: warning 105%; shutdown 110% Generator under frequency: warning 95%; shutdown 90% Over current shutdown ELECTRICAL CONTROLS Remote start / stop contacts located next to lug box Lockable control box door with diagnostics window Lockable lug box with safety switch o Trips main breaker when lug door is opened o Disables voltage regulator Cable entry guides to the lug box o Restricts access of foreign objects Output ground connection lug inside lug box 125A main breaker with shunt trip Convenience receptacles with individual breakers (restricted use in high wye mode) o (2) 120V 20 Amp GFCI duplex outlets (Nema 5-20R type) o (2) 125 / 250V 50 Amp, 3 pole, 4 wire twistlock (Non-Nema 6369) Panel mounted rheostat for voltage adjustment - +/- 10% 720 CCA wet cell battery Phone: 800-926-9768 Fax: 920-361-2214 www.m-p-llc.com Page 2 of 5

ENCLOSURE Generac Mobile Power decals Flip-Hood Patented design - aluminum, sound attenuated enclosure o Easy access for daily maintenance o Centralized location for all electrical connections/wiring o UV & fade resistant, high temperature cured, white polyester powder paint o Insulated and baffled o 68 db(a) at 23 feet prime power Fully lockable enclosure including doors and fuel fill Stainless steel hinges on doors Emergency stop switch located on outside of enclosure Central lifting point Multi-lingual operating/safety decals Document holder with operating manual including AC/DC wiring diagrams TRAILER Flip-Tongue design DOT approved tail, side, brake, and directional lights o Recessed rear lights Transportation tie downs Safety chains with spring loaded safety hooks 2 ball hitch 3500 lb. axle 3000 lb. tongue jack with footplate P205/75R15 tubeless tires 6 ply WEIGHTS & DIMENSIONS Skid mounted Dry weight: 2020 lbs (996 kg) Operating weight: 2475 lbs (1206 kg) 95 x 35 x 52 in (2.41 x 0.89 x 1.32 m) Trailer mounted Dry weight: 2540 lbs (1167 kg) Operating weight: 2990 lbs (1377 kg) 150 x 57 x 67 in (3.81 x 1.45 x 1.70 m) WARRANTY Engine and generator covered under OEM warranty consult factory for details. CERTIFICATIONS CSA certified Phone: 800-926-9768 Fax: 920-361-2214 www.m-p-llc.com Page 3 of 5

MMG35FH Options ENGINE OPTIONS In-line engine block heater (Kim Hotstart) Fuel transfer pump ELECTRICAL CONTROLS OPTIONS 720 CCA gel cell battery Battery disconnect Battery charger 2A trickle GENERATOR OPTIONS PMG Generator - critical grade power quality Super Start Generator - motor starting applications VOLTAGE OUTPUT OPTIONS 4 position phase switch Single phase 120 / 240V Zig Zag Three phase 120 / 208V Low Wye Three phase 277 / 480V High Wye Three phase 120 / 240V Delta Dedicated voltage configurations Buck Transformer kit Provides 120V at GFCI outlets when in 277/480V Cam locks SYSTEM CONTROLS OPTIONS Analog gauges Auxiliary strobe/audible indication for soft & hard alarm conditions COOLANT OPTIONS 60/40 Coolant - cold weather applications ENCLOSURE OPTIONS Fire extinguisher Interior cabinet light Control panel light FUEL TANK OPTIONS 120% Containment Phone: 800-926-9768 Fax: 920-361-2214 www.m-p-llc.com Page 4 of 5

TRAILER OPTIONS Single axle trailer w/ surge brakes Single axle trailer w/ electric brakes Tandem axle trailer w/ surge brakes Tandem axle trailer w/ electric brakes 6 pin or 7 spade electrical connectors Spare tire/wheel kit HITCH OPTIONS 3 lunette ring 2 5/16 ball Adjustable height options: 2 ball 2 5/16 ball Phone: 800-926-9768 Fax: 920-361-2214 www.m-p-llc.com Page 5 of 5