Magnum user manual

Similar documents
FT-100 Fire Training Fog Machine User Manual English

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

TABLE OF CONTENTS. Hurricane 1300 User Manual 2 Rev. 4

Bubble King. User Manual

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Meaco 30L and Meaco 40L dehumidifier instruction manual

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

=============================== WARNING

Acrobat. user manual

INFRARED QUARTZ WALL HEATER

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Fixture One Power Cord One User Manual One Omega Bracket One DMX Cable - One

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

19 LED Tube Controller ORDERCODE 41003

User Manual for CH-PFC76810

ORLAND FOLLOW PR-1211

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Applied Electronics. Commercial Dimming System UPDATE NOTICE

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

HP ProDisplay P19A LED Backlit Monitor. User Guide

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

LED BAR 126 / 252 RGB. Owner s Manual LED BAR RGB

V94 BULK TAPE DEGAUSSER

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

OPERATING INSTRUCTIONS

MCR1900 Media Converter 19-Slot Chassis

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Portable Air Conditioner

Drayton Digistat +2RF/+3RF

USER S MANUAL HSC-24A

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

OPL BASIC. Dosing System for Professional Laundry machines. Contents

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

12 Volt 30 Amp Digital Solar Charge Controller

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

Mania SCX500. user manual

12-Volt 10-Amp Regulated Power Supply

Model Owner s Manual. Español - P. 19 Français - P. 39

1. Before You Begin... 3

Thermo Top - Troubleshooting Tree

Atomic user manual

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

K E E P E TH T I H S I MA M N A U N A U L A FO F R

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

TIG INVERTER INSTRUCTION MANUAL

24 Wide Screen LED Monitor with HDMI

BeoLab 1. User s guide

Overheating limit control

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

Ultrasonic support removal tank

DP-DMX20L 4 CHANNEL DMX DIMMER PACK MODE MENU DISPLAY. OUTPUT: 10A/CH, TOTAL 20A Max. DMX CHANNEL RECEIVE TOTAL DMX CHANNEL DIMMER / SWITCH

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

MANUAL PC1000R

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

BeoLab 7-1 BeoLab 7-2. Guide

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

SunMaxx Solar Filling Station Operating Instructions

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Hegel H80 High End Integrated Amplifier. User manual

SMD Rework Station TABLE OF CONTENTS

Streaming Potential System (SPT1000, SPD1000)

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

4.3-inch Back-Up Camera

LED Par 56 Short DMX ORDERCODE 42421

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

Oil and Coolant Circulating Heating System. Model - OCSM

RE-3 : SOLID TOP RANGE RANGE TOP ONLY

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

USER MANUAL. 914 Power Amplifier MODEL: P/N: Rev 1

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

Model 43AP Pneumatic Controller, Style B

PROFESSIONAL WIRELESS DMX CONTROLLER USER S MANUAL EWDMXSYSTEM

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

Bottom Loading Water Dispenser

VX 2400 Dimmer User's Manual

Congratulations! Thank you!

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Please read operating instructions carefully before use and keep for further reference.

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

INSTALLATION GUIDE 1

TMS TANK MANAGEMENT SYSTEM

Transcription:

Magnum 2000 user manual

Figure 1: Dimensions in mm 1995, 2000 Martin Professional A/S, Denmark. All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing from Martin Professional A/S, Denmark. Printed in Denmark. P/N 35000038, Rev. C 2

INTRODUCTION 1 FEATURES The Magnum 2000 is a high performance micro-controller based smoke machine that features: Specially designed heating element for long life and reliability High pressure pump Variable smoke output Remote control unit with auto-timer and memory function 0-10 V control input Slave output for control of multiple units from a single remote control 9.5 liter (2.5 gallon) internal tank Electronic and mechanical overheating protection with manual reset Mounting bracket and carrying handles Non-toxic fog-fluid Introduction 3

SAFETY This product is for professional use only. It is not for household use. For safe usage, read this manual before powering or installing the device, follow the safety precautions listed below and observe all warnings in this manual and printed on the device. If you have questions about how to operate the device safely, please contact your Martin dealer or call the Martin 24-hour service hotline at +45 70 200 201. Keep the output nozzle at least 60 cm (24 inches) away from people and objects. Never point the output at people s heads or place your hand over the nozzle. Disconnect the device from AC power before refilling the fluid tank or servicing. Use specified fog fluid only. Always ground (earth) the device electrically. Use only a source of AC power that complies with local building and electrical codes and has both overload and groundfault protection. Do not expose the device to rain. Never operate the smoke machine if it is damaged or if parts are missing. Never attempt to bypass the thermostatic switch or fuses. Always replace defective fuses with ones of the specified type and rating. Allow the device to cool before handling. Refer all service not described in this manual to a qualified technician. Do not install the smoke machine directly over people. When suspending the device above ground level, verify that the structure can hold at least 10 times the weight of all installed devices. Use an approved means of secondary attachment such as a safety cable. Block access below the work area whenever installing or removing the device. 4 Introduction

SET UP 2 Your Magnum 2000 package comes complete with the following items: Magnum 2000 smoke machine with remote control unit 5 meter (16.5 ft) XLR/XLR cable for remote control Adaptor-cap with fluid filter for fluid tank Users guide Warning! Before attempting any of the following ensure that the machine is disconnected from mains power. FITTING THE MAINS PLUG Warning! For protection from fire and electric shock, the fixture must be grounded (earthed). The Magnum 2000 is delivered from the factory without a plug on the mains lead. You will have to fit a suitable plug (one that fits your local wall outlet) before you can connect the machine to the mains. The double isolated mains lead on the Magnum 2000 contains three wires. Connect the brown wire to the LIVE pin, the blue wire to the NEUTRAL pin, and the Yellow/Green wire to the EARTH pin (ground). INSTALLATION The Magnum 2000 may be placed on a flat surface or suspended by means of a rigging clamp (not included) fastened through the 13 mm (0.5 inch) hole in the mounting bracket. The adjustable bracket allows you to turn and/or tilt the machine. Warning! Warning! DO NOT install directly above or within 60cm ( 24 inches) of people. Use a safety cable for secondary attachment. Set up 5

Important! FOG FLUID Martin fog fluid comes in disposable containers that fit the smoke machine. Use Martin or Jem Pro-Smoke fog fluid only. Other fluids may clog the heating element or spit from the nozzle. To install the fluid tank 1 Place the fluid tank in the Magnum 2000 as shown on page 2. 2 Remove the container cap and screw on the tank adaptor cap. Verify that the tube (with fluid filter) reaches the bottom of the tank. 3 Connect the fluid tube to the fluid outlet of the tank adaptor cap. 6 Set up

OPERATION 3 For optimum performance from your Magnum 2000: Keep the machine and the remote control unit away from damp rooms or wet conditions. Never operate the machine without fluid in the tank, as this may harm the pump system. Use clean fluid to avoid clogging of the heating element and damage to the pump. Use Martin fog fluid. This fluid is non- toxic, water-based and specially designed for Martin smoke machines. Jem Pro-Smoke fluids may be substituted. (REMOTE) CONTROL UNIT The control unit is secured to the back panel by two thumbscrews. It may be removed for remote control and placed in a rack or on a table. To remove the control unit 1 Unscrew the thumbscrews on either side of the control unit and pull it out of the control unit well. 2 Use the included cable to connect either one of the 3-pin outputs on the control unit to the 3-pin input inside the control unit well. Either of the control unit s outputs may be used, but not both. To connect additional machines, use the Slave output on the rear panel of the smoke machine. POWER To enable the heater circuit, simply turn the knob on the control unit clockwise until the POWER LED lights. Operation 7

STATUS The three LEDs on the rear panel of the smoke machine indicate the machines status. POWER (red): There is power to the heater. HEAT (red): The machine is heating. The LED flashes rapidly and then more slowly as the heating cycle nears the end. It turns off when the heating element has reached maximum temperature. The heating cycle for a cold machine takes 8 to 10 minutes. READY (green): Ready to produce smoke. The HEAT and READY LEDs can be on simultaneously as smoke production is possible when the machine is heating. MANUAL OPERATION As soon as the green READY LED turns on, you can make smoke by pressing the Smoke button on the control unit. The output level can be adjusted using the Smoke output knob. Though the fluid pump stops when you release the Smoke button, smoke emission will continue for another few seconds because the fluid in the heating element is under pressure. AUTO-TIMER The auto-timer allows you to program output duration and level at repeatable intervals. The maximum programmable interval (output duration + pause) is approximately 1 hour. The auto-timer sequence is stored in the smoke machine s memory and is not cleared when disconnecting the machine from mains power. When switched on, the machine will execute the auto-timer sequence as soon the machine is ready. Adjusting the smoke output potentiometer does not override the stored auto-timer level. You can still produce smoke manually and, if this level is higher than the stored level, it will take precedence. To set the auto-timer 1 Adjust the Smoke output knob to the desired level. 2 Press the smoke button for the desired output duration. 3 Wait for the desired pause time and then press the timer store button. 8 Operation

4 To terminate the auto-timer sequence, press the timer store button for 5 seconds. This clears the memory. For example, to program 15 seconds of smoke every 2 minutes, press the smoke button for 15 seconds, wait 1 minute and 45 seconds, and then press timer store. 0-10 V OPERATION Operation via a 0-10 volt signal is similar to operation via the remote control unit. Unplug the remote control unit and connect your analog source to the XLR control input inside the control unit well. Verify that GND (ground) on your analog source connects to pin 1 on the XLR control input and that the +0-10V output connects to pin 3. The analog control levels are shown below. Voltage Function 0-1.0 V Standby 1.0-2.5 V Heater power on 2.5-9.5 V Smoke emission, increases with voltage 9.5-10.0 V Timer store MULTIPLE MACHINES Whether you operate your Magnum 2000 via the control unit or a 0-10 volt source, you can command additional machines through the XLR slave output on the back panel. Connect the slave output on the first machine to the control input (located inside the control unit well) of the next machine. Continue by similarly connecting as many machines as desired output to input. All machines connected in this manner will produce smoke at the same time and output level as the first machine. Operation 9

BASIC SERVICE 4 TROUBLESHOOTING No light in the POWER LED on rear panel. No light in the POWER LED on the control unit. Pressing the smoke button activates the pump but no smoke is produced. The machine indicates heating but the READY LED never lights. Check the mains plug. Check the fuse. Is the remote control unit properly connected? Check XLR/XLR cable. Check that the fluid filter reaches the bottom of the tank. Check that the fluid tube is connected to the inlet on the machine. Reset the thermo-switch as described below. If the problem persists then consult your Martin dealer. In case of other failures, contact a Martin service technician. FUSE To replace the fuse 230 V model: Use a 10A slow-blow fuse. 115 V model: Use a 15A slow-blow fuse. Warning! Before attempting any of the following ensure that the machine is disconnected from mains power. 1 Remove the fluid tank from the machine. 2 Remove the Philips screws that secure top-cover at the back of the machine. 3 Slide the cover forwards until the circuit board (PCB) is accessible. 4 Locate on the left hand-side of the PCB fuse "F1". 5 Replace the fuse with a new one (T 10 A at 230 V, T 15 A at 115 V). 6 Re-assemble the device before connecting to the mains. 10 Basic service

THERMO-SWITCH The Magnum 2000 has an over-heat switch (thermo-switch) that interrupts power to the heating element should it reach a temperature above normal. The thermo-switch must be reset manually after it has been activated. This reset is performed by pressing the plastic button on top of the switch. If the thermo-switch activates repeatedly, contact your Martin dealer for service. To reset the thermo-switch Warning! Before attempting any of the following ensure that the machine is disconnected from mains power and cooled down. 1 Remove the fluid tank from the machine. 2 Remove the two Philips screws that secure the top cover over the heating element. 3 Slide the cover backwards until the thermo-switch becomes accessible. The thermo-switch is located on the mid, left hand side of the heating element with two wires attached. 4 Press the plastic button on the thermo-switch to reset it. 5 Reassemble the machine before connecting to the mains. Basic service 11

SPECIFICATIONS 5 Dimensions: See figure 1 Weight (empty tank): AC-voltage - 230 V model: AC-voltage - 115 V model: AC-frequency: Power consumption: Maximum fluid consumption: Tank capacity: Warm-up time: Fuse: Overheat protection: 13 Kg (28.5 lb) 200-260 V 100-130 V 50 / 60 Hz 1700 W 0.2 l/min 9.5 l (2.5 gall) 8-10 min 10 AT at 200-260 V 15 AT at 100-130 V Electronic / Mechanical (with manual reset)