SOLAR PUMPING SYSTEM
SOLAR PUMPING SYSTEM Continuous data connection for remote telemetry made available via a RS-485 port. IP55, NEMA 3 rated enclosure for outdoor use. Easy to read, 3 digit, 7 segment LED display. Provides ease of programming and troubleshooting. Push button navigation for ease of programming and display control. Sliding door protects display from wildlife and environmental abuse. DC and AC power supply input. Automatic switching to AC generator backup power if no DC is available from the solar array. Contacts for up to two level control switches (can also operate from a pressure switch, used for long pipe runs). TRIP contact for flow switch to detect dry run conditions and protect the motor. Removable bottom gland plate makes conduit installation simple. Robust enclosure made of 1.9 and 1.5mm (14 and 16 gauge) zinc-plated and powder coated steel to stand up to the toughest environmental conditions. Applications Livestock watering Tank/Cistern filling Wildlife refuge & game farms Rural water supply for villages & homesteads Irrigation systems Fountains Vineyards Renewable energy projects Built-in Diagnostics and Protection The SubDrive Solar QuickPAK products include diagnostic features and built-in protection from potentially harmful conditions. Surge Short circuit Underload Overheated controller Undervoltage Dry run Locked pump Reverse polarity Open circuit
System Solutions All-in-One Package The SubDrive Solar QuickPAK is the System Solution to your solar pumping requirements. Using Franklin quality components, our technical expertise in groundwater pumping, and innovative thinking based on global market inputs, we have developed a rugged, high-output system which tackles the challenges of remote and harsh environments. No other system delivers the features, benefits, and reliability of SubDrive Solar QuickPAK in just one package! The SubDrive QuickPAK includes: Franklin Solar motor Franklin Solar pump SubDrive Solar controller Flow switch with 1m cable Variety of flow rates available in: 3, 45, 7, 15, and 27 lpm (1, 15, 25, 45, and 9 USGPM) Motor and drive ratings available in: 1.1 and 2.2 kw (1.5 and 3. hp) Features High flow system for faster tank fill and significant water output Proven motor and pump technology and reliability Robust IP55, NEMA 3 drive enclosure minimizes impact of wildlife, insects, dust, and weather DC and AC power inputs with auto-switching to generator back-up Seven segment controller display shows real-time input watts and system status Remote telemetry capability through a RS-485 continuous data port MPPT Max Power Point Tracking for maximizing efficiency of input power Soft start feature prevents water hammer and increases system life Allows use of new solar array or retrofit to existing array (subject to size and performance check) Simple installation and no required maintenance Built-in diagnostics and protection C-tick and UL approved 1
Ordering Information Contents SubDrive Solar QuickPAK Ordering Information...2 SubDrive Solar QuickPAK 1.1 kw Performance... 3-7 SubDrive Solar QuickPAK 2.2 kw Performance...8-12 Dimensions...13 Drive Specifications...14 Quick Install Guide...15 Model Number Description XXX SS QP - X.XKW Motor Rating: 1.1, or 2.2 kw (1.5 or 3. hp) QuickPAK SubDrive Solar Pump Flow: 3, 45, 7, 15, or 27 lpm (1, 15, 25, 45, or 9 USGPM) SubDrive Solar QuickPAK Model Numbers Solar QuickPAK SubDrive Solar Controller Solar Pump BSPP Solar Motor Flow Switch BSPP Order No. QuickPAK Model Drive Model Part No. LPM USGPM Solar Pump Part No. kw Part No. Model Part No. 9312 3SSQP-1.1 kw SD Solar 1.1 kw N3 58731113 3 1 3SL15S4-PEXB 92111 1.1 23454194S C25 2261411 9313 3SSQP-2.2 kw SD Solar 2.2 kw N3 58731223 3 1 3SL15S4-PEXB 92111 2.2 23436256 C25 2261411 93152 45SSQP-1.1 kw SD Solar 1.1 kw N3 58731113 45 15 45SL15S4-PEXB 921511 1.1 23454194S C25 2261411 93153 45SSQP-2.2 kw SD Solar 2.2 kw N3 58731223 45 15 45SL15S4-PEXB 921511 2.2 23436256 C25 2261411 93252 7SSQP-1.1 kw SD Solar 1.1 kw N3 58731113 7 25 7SL15S4-PEXB 922511 1.1 23454194S C25 2261411 93253 7SSQP-2.2 kw SD Solar 2.2 kw N3 58731223 7 25 7SL15S4-PEXB 922511 2.2 23436256 C25 2261411 93452 (a) 15SSQP-1.1 kw SD Solar 1.1 kw N3 58731113 15 45 15SL15S4-PEXB 924511 1.1 23454194S F21 2261911 93453 (a) 15SSQP-2.2 kw SD Solar 2.2 kw N3 58731223 15 45 15SL15S4-PEXB 924511 2.2 23436256 F21 2261911 9392 (a) 27SSQP-1.1 kw SD Solar 1.1 kw N3 58731113 27 9 27SL15S4-PEXB 92911 1.1 23454194S F21 2261911 9393 (a) 27SSQP-2.2 kw SD Solar 2.2 kw N3 58731223 27 9 27SL15S4-PEXB 92911 2.2 23436256 F21 2261911 Solar QuickPAK SubDrive Solar Controller Solar Pump NPT Solar Motor Flow Switch NPT Order No. QuickPAK Model Drive Model Part No. USGPM LPM Solar Pump Part No. kw Part No. Model Part No. 9412 1SSQP-1.5 hp SD Solar 1.1 kw N3 58731113 1 3 1SL15S4-PEX 9211 1.1 23454194S C25 2261412 9413 1SSQP-3. hp SD Solar 2.2 kw N3 58731223 1 3 1SL15S4-PEX 9211 2.2 23436256 C25 2261412 94152 15SSQP-1.5 hp SD Solar 1.1 kw N3 58731113 15 45 15SL15S4-PEX 92151 1.1 23454194S C25 2261412 94153 15SSQP-3. hp SD Solar 2.2 kw N3 58731223 15 45 15SL15S4-PEX 92151 2.2 23436256 C25 2261412 94252 25SSQP-1.5 hp SD Solar 1.1 kw N3 58731113 25 7 25SL15S4-PEX 92251 1.1 23454194S C25 2261412 94253 25SSQP-3. hp SD Solar 2.2 kw N3 58731223 25 7 25SL15S4-PEX 92251 2.2 23436256 C25 2261412 94452 (a) 45SSQP-1.5 hp SD Solar 1.1 kw N3 58731113 45 15 45SL15S4-PEX 92451 1.1 23454194S F21 2261912 94453 (a) 45SSQP-3. hp SD Solar 2.2 kw N3 58731223 45 15 45SL15S4-PEX 92451 2.2 23436256 F21 2261912 9492 (a) 9SSQP-1.5 hp SD Solar 1.1 kw N3 58731113 9 27 9SL15S4-PEX 9291 1.1 23454194S F21 2261912 9493 (a) 9SSQP-3. hp SD Solar 2.2 kw N3 58731223 9 27 9SL15S4-PEX 9291 2.2 23436256 F21 2261912 * A 1 meter (~33 foot) cable for use with the flow switch is included in the controller packaging ** 316SS Motors available on request (a) High capacity pumps, 15 lpm (45 USGPM) and higher, in a QuickPAK are not supplied with an internal check valve. 2
Pump Performance 3SSQP-1.1 kw SubDrive Solar 1.1 kw, 3 lpm Pump End, 1.1 kw Motor 5 45 4m (57 psi) 6m (85 psi) 12 4 8m (114 psi) 1 FLOW (LITERS/MINUTE) 35 3 25 2 15 1m (142 psi) 12m (17 psi) 14m (199 psi) 8 6 4 FLOW (US GALLONS/MINUTE) 1 2 5 2 4 6 8 1 12 14 16 18 2 PV POWER (WATTS) PV Power (Watts) 4 6 8 1 12 14 16 18 2 Head (m) 4 14 24 3 35 39 43 46 48 6 16 24 29 33 37 41 44 46 8 16 23 28 32 36 39 41 1 16 22 26 3 34 36 12 19 2 24 28 31 14 16 18 22 25 * 1 bar = 1.2 meters of head **Refer to Drive Specifications table on page 14 for PV source power and voltage recommended operating ranges 3
Pump Performance 45SSQP-1.1 kw SubDrive Solar 1.1 kw, 45 lpm Pump End, 1.1 kw Motor 8 7 4m (57 psi) 2 FLOW (LITERS/MINUTE) 6 5 4 3 6m (85 psi) 8m (114 psi) 1m (142 psi) 12m (17 psi) 14m (199 psi) 15 1 FLOW (US GALLONS/MINUTE) 2 5 1 2 4 6 8 1 12 14 16 18 2 PV POWER (WATTS) PV Power (Watts) 4 6 8 1 12 14 16 18 2 Head (m) 4 23 34 42 48 54 59 64 68 72 6 23 33 4 46 51 56 61 64 8 21 3 37 43 48 53 57 1 18 27 34 39 45 49 12 15 24 3 36 4 14 12 2 27 32 * 1 bar = 1.2 meters of head **Refer to Drive Specifications table on page 14 for PV source power and voltage recommended operating ranges 4
Pump Performance 7SSQP-1.1 kw SubDrive Solar 1.1 kw, 7 lpm Pump End, 1.1 kw Motor FLOW (LITERS/MINUTE) 12 1 8 6 4 2m (28 psi) 3m (43 psi) 4m (57 psi) 5m (71 psi) 6m (85 psi) 7m (1 psi) 8m (114 psi) 9m (128 psi) 3 25 2 15 1 FLOW (US GALLONS/MINUTE) 2 5 2 4 6 8 1 12 14 16 18 2 PV POWER (WATTS) PV Power (Watts) 4 6 8 1 12 14 16 18 2 Head (m) 2 47 68 83 94 14 111 117 3 25 5 68 81 92 11 18 114 4 31 52 67 8 9 97 15 11 5 1 35 54 67 79 87 95 11 6 17 38 55 67 77 85 92 7 22 4 55 66 75 83 8 26 42 55 65 73 9 1 28 43 54 64 * 1 bar = 1.2 meters of head **Refer to Drive Specifications table on page 14 for PV source power and voltage recommended operating ranges 5
Pump Performance 15SSQP-1.1 kw SubDrive Solar 1.1 kw, 15 lpm Pump End, 1.1 kw Motor 2 18 1m (14 psi) 15m (21 psi) 2m (28 psi) 5 16 25m (36 psi) 4 FLOW (LITERS/MINUTE) 14 12 1 8 6 3m (43 psi) 35m (5 psi) 4m (57 psi) 45m (64 psi) 3 2 FLOW (US GALLONS/MINUTE) 4 1 2 2 4 6 8 1 12 14 16 18 2 PV POWER (WATTS) PV Power (Watts) 4 6 8 1 12 14 16 18 2 Head (m) 1 77 12 152 174 188 15 43 87 12 145 162 174 181 2 12 57 92 118 137 152 161 167 17 25 28 65 93 115 13 14 149 154 3 39 68 91 19 121 13 136 35 15 46 7 88 13 114 12 4 25 49 7 85 96 15 45 29 51 68 8 9 * 1 bar = 1.2 meters of head **Refer to Drive Specifications table on page 14 for PV source power and voltage recommended operating ranges 6
Pump Performance 27SSQP-1.1 kw SubDrive Solar 1.1 kw, 27 lpm Pump End, 1.1 kw Motor FLOW (LITERS/MINUTE) 35 3 25 2 15 1 1m (14 psi) 15m (21 psi) 2m (28 psi) 9 8 7 6 5 4 3 2 FLOW (US GALLONS/MINUTE) 5 1 2 4 6 8 1 12 14 16 18 2 PV POWER (WATTS) PV Power (Watts) 4 6 8 1 12 14 16 18 2 Head (m) 1 9 162 214 254 285 31 33 345 15 44 112 164 24 235 26 281 2 68 118 157 189 215 * 1 bar = 1.2 meters of head **Refer to Drive Specifications table on page 14 for PV source power and voltage recommended operating ranges 7
Pump Performance 3SSQP-2.2 kw SubDrive Solar 2.2 kw, 3 lpm Pump End, 2.2 kw Motor FLOW (LITERS/MINUTE) 6 5 4 3 2 4m (57 psi) 6m (85 psi) 8m (114 psi) 1m (142 psi) 12m (17 psi) 14m (199 psi) 16m (227 psi) 18m (256 psi) 2m (284 psi) 14 12 1 8 6 FLOW (US GALLONS/MINUTE) 4 1 2 5 1 15 2 25 3 35 PV POWER (WATTS) PV Power (Watts) 75 1 125 15 175 2 225 25 275 3 325 35 Head (m) 4 28 35 39 43 47 51 53 56 58 6 23 29 34 38 43 46 49 52 55 58 6 8 15 23 29 34 38 41 45 48 51 53 56 58 1 16 23 28 33 37 4 43 46 49 52 54 12 16 22 27 32 35 38 42 44 47 5 14 16 21 26 3 34 37 4 43 45 16 15 2 24 28 32 35 38 41 18 13 28 23 26 3 33 36 2 12 16 21 24 28 31 * 1 bar = 1.2 meters of head **Refer to Drive Specifications table on page 14 for PV source power and voltage recommended operating ranges 8
Pump Performance 45SSQP-2.2 kw SubDrive Solar 2.2 kw, 45 lpm Pump End, 2.2 kw Motor FLOW (LITERS/MINUTE) 9 8 7 6 5 4 3 4m (57 psi) 6m (85 psi) 8m (114 psi) 1m (142 psi) 12m (17 psi) 14m (199 psi) 16m (227 psi) 18m (256 psi) 2m (284 psi) 2 15 1 FLOW (US GALLONS/MINUTE) 2 5 1 5 1 15 2 25 3 35 PV POWER (WATTS) PV Power (Watts) 75 1 125 15 175 2 225 25 275 3 325 35 Head (m) 4 37 45 52 58 63 68 72 76 8 83 87 6 25 36 44 5 56 61 65 69 74 78 82 84 8 25 34 42 48 53 58 63 67 71 75 78 1 1 24 33 4 46 52 56 6 64 68 72 12 1 23 31 38 43 48 53 58 62 66 14 1 21 28 35 41 46 5 55 54 16 18 26 33 38 43 47 52 18 16 23 29 35 4 44 2 16 2 26 32 37 * 1 bar = 1.2 meters of head **Refer to Drive Specifications table on page 14 for PV source power and voltage recommended operating ranges 9
Pump Performance 7SSQP-2.2 kw SubDrive Solar 2.2 kw, 7 lpm Pump End, 2.2 kw Motor FLOW (LITERS/MINUTE) 16 14 12 1 8 6 4 4m (57 psi) 6m (85 psi) 8m (114 psi) 1m (142 psi) 12m (171 psi) 14m (2 psi) 4 35 3 25 2 15 1 FLOW (US GALLONS/MINUTE) 2 5 5 1 15 2 25 3 35 PV POWER (WATTS) PV Power (Watts) 75 1 125 15 175 2 225 25 275 3 325 35 Head (m) 4 4 62 79 91 12 111 12 126 133 138 142 146 6 27 5 66 8 91 1 18 116 122 127 132 8 15 37 55 68 8 9 98 15 112 117 1 26 43 57 7 79 87 95 11 12 14 32 46 58 68 77 85 14 22 36 48 57 66 * 1 bar = 1.2 meters of head **Refer to Drive Specifications table on page 14 for PV source power and voltage recommended operating ranges 1
Pump Performance 15SSQP-2.2 kw SubDrive Solar 2.2 kw, 15 lpm Pump End, 2.2 kw Motor 3 FLOW (LITERS/MINUTE) 25 2 15 1 1m (14 psi) 15m (21 psi) 2m (28 psi) 25m (36 psi) 3m (43 psi) 35m (5 psi) 4m (57 psi) 45m (64 psi) 5m (71 psi) 55m (78 psi) 6m (85 psi) 7 6 5 4 3 FLOW (US GALLONS/MINUTE) 2 5 1 5 1 15 2 25 3 35 PV POWER (WATTS) PV Power (Watts) 75 1 125 15 175 2 225 25 275 3 325 35 Head (m) 1 132 165 191 211 227 239 248 255 261 265 15 1 135 164 186 24 217 228 236 244 249 251 255 2 69 17 137 162 181 196 29 219 226 232 236 24 25 4 8 111 138 16 176 19 21 21 216 223 226 3 53 87 114 137 155 171 184 193 21 27 212 35 27 63 91 115 135 152 165 176 186 193 199 4 4 7 95 116 134 148 16 17 178 185 45 16 47 75 98 115 132 145 155 164 172 5 27 55 79 98 115 128 141 15 158 55 35 6 81 99 113 125 136 146 6 16 42 64 83 97 11 123 131 * 1 bar = 1.2 meters of head **Refer to Drive Specifications table on page 14 for PV source power and voltage recommended operating ranges 11
Pump Performance 27SSQP-2.2 kw SubDrive Solar 2.2 kw, 27 lpm Pump End, 2.2 kw Motor FLOW (LITERS/MINUTE) 5 45 4 35 3 25 2 15 1m (14 psi) 15m (21 psi) 2m (28 psi) 25m (36 psi) 3m (43 psi) 35m (5 psi) 12 1 8 6 4 FLOW (US GALLONS/MINUTE) 1 5 1 5 1 15 2 25 3 35 PV POWER (WATTS) PV Power (Watts) 75 1 125 15 175 2 225 25 275 3 325 35 Head (m) 1 119 188 243 287 323 354 379 4 418 432 445 454 15 89 156 29 25 286 316 34 361 378 391 42 2 58 122 173 214 248 276 3 32 338 351 25 27 89 137 177 21 239 261 28 296 3 52 1 139 171 198 221 239 35 16 61 1 13 157 179 * 1 bar = 1.2 meters of head **Refer to Drive Specifications table on page 14 for PV source power and voltage recommended operating ranges 12
Dimensions A B D C G.1 G.2 F E SubDrive Solar Controller Dimensions A B C D E F G.1 G.2 Centimeters 25.9 46.4 53.4 5.8 15.2 7.6 22.1 26.5 Inches 1.2 18.3 21. 2. 6. 3. 8.7 1.4 A B C Solar PMA Dimensions A B C lpm USGPM kw hp Stages Discharge mm inches mm inches mm inches 3 1 1.1 1.5 18 642 25.3 298 11.7 94 37. 1 1/4" 45 15 1.1 1.5 15 521 2.5 298 11.7 819 32.2 1 1/4" 7 25 1.1 1.5 1 488 19.2 298 11.7 786 3.9 1 1/4" 15 45 1.1 1.5 7 593 23.3 298 11.7 891 35.1 2" 27 9 1.1 1.5 5 575 22.6 298 11.7 873 34.4 2" 3 1 2.2 3 18 645 25.3 48 16.1 153 41.4 1 1/4" 45 15 2.2 3 15 521 2.5 48 16.1 929 36.6 1 1/4" 7 25 2.2 3 1 488 19.2 48 16.1 896 35.3 1 1/4" 15 45 2.2 3 7 593 23.3 48 16.1 11 39.4 2" 27 9 2.2 3 5 575 22.6 48 16.1 983 38.7 2" Note: Maximum diameter across cable guard is 99.1 mm (3.9") on all models. 13
Drive Specifications SubDrive Solar Controller Specifications 1.1 kw model 2.2 kw model Controller Model No. 58731113 58731223 General Output voltage, max 2 V AC, 3-phase 2 V AC, 3-phase Max Amps (RMS) 6.8 A, each phase 12.5 A, each phase Output Frequency 3-58 Hz 3-68 Hz Efficiency at Max Power 96% 96% PV Source Input Voltage, at mpp 15* 33 V DC 15* 33 V DC Max Amps Input 7 A DC, continuous 12 A DC, continuous Power at mpp 5 2 watts 875 35 watts Alternate AC Generator Input voltage 23 V AC, single-phase 23 V AC, single-phase Max Amps (RMS) 16 A 25 A Power and VA capability For Use With Follow Instruction Manual for proper Generator Sizing Data Follow Instruction Manual for proper Generator Sizing Data SubDrive Solar Motor 23454194S** 23436256** SubDrive Solar Pumps (BSPP) SubDrive Solar Pumps (NPT) lpm USGPM 3 1 92111 92111 45 15 921511 921511 7 25 922511 922511 15 45 924511 924511 27 9 92911 92911 3 1 9211 9211 45 15 92151 92151 7 25 92251 92251 15 45 92451 92451 27 9 9291 9291 Controller Size L X W X D L X W X D Centimeters (53.34 X 25.87 X 21.87cm) (53.34 X 25.87 X 26.31cm) Inches (21." X 1.19" X 8.61") (21." X 1.19" X 1.36") Weight Operating Conditions Temperature Range 19 kg (41 lbs) 22 kg (47 lbs) -25 C to 5 C (4 C max when using AC generator) -25 C to 5 C (4 C max when using AC generator) Relative Humidity Range to 1% Condensing to 1% Condensing * Drive will attempt to pump with input voltage as low as 15 V DC, and will maintain logic functions at even lower voltage. However, 15 V DC should not be interpreted as an adequate rated PV array output voltage for any installation. ** Motor model without lead - The lead is provided in the QuickPAK carton. Contact local FE office for lead replacement part numbers 14
Programming Header System Quick Install Guide DC Power Solar PV Array Alternate AC Power (Optional) SubDrive Solar Controller 3A - 2 Pole DC Rated Disconnect COMM. COMM. STATUS UP MENU SELECT DOWN 22597911, 22599611, 4-2mA -5VDC 4-2mA OUT SOLAR SUBMERSIBLE PUMP CONTROLLER DC Polarity Green = OK E1 E2 E3 E4 E5 E6 E7 Motor Under Locked External Open Short Overheated Red = Reversed Underloaded Voltage Pump Circuit Circuit Controller Running Power On Suitable for use on a circuit capable of delivering not more than 5 rms symmetrical amperes, 25V COM maximum. Use 9 ºC CU wire rate 3V min. Tighten line terminals to 15 in-lbs. NC NO + - L1 L2 BLK RED YEL RUN STOP TRIP SOLAR PRIMARY BACKUP DC AC MOTOR E8 Internal Error Pump/Motor Flow Switch (required for operation) Level Control Stop (OPEN) (CLOSED) Level Control Run (OPEN) (CLOSED) 2 Level Control Switch Operation Trip 15
16 Notes
SOLAR PUMPING SYSTEM SubDrive Solar and QuickPAK Selector: Franklin s user-friendly Solar SubDrive QuickPAK Selector helps you determine the optimal system for your solar project. Simply input your location, duty requirements, and solar panel characteristics (if known) and the system will automatically recommend the Solar QuickPAK model and array configuration best for your application. * Above screen shot is illustrative only and is subject to continuous improvement The Franklin Electric SubDrive Solar Selector and other information on our series of solar products can be found on Franklin Electric s Solar Website: www.franklin-electric.com/solar
ASEAN Franklin Electric (SEA) Pte. Ltd. Singapore Representative Office 1 Changi Business Park Avenue 1 # 3-1, Ultro Building Singapore 48658 Phone: +65.6789.6865 Fax: +65.6789.155 CHINA Franklin Electric (Shanghai) Co. Ltd. Unit 12-3, Shanghai Central Plaza No. 227, Huang Pi Bei Road, Shanghai 23, China Phone: +86.21.6327.99 Fax: +86.21.6327.91 INDIA Franklin Electric India Pvt. Ltd. DBS-26, 1st Floor World Trade Tower Barakhamba Avenue New Delhi 11 1, India Tel: +91.11.438.4697 Fax: +91.11.2341.474 KOREA Franklin Electric Korea 9th Floor Heraffice Building 17-41 SaDang-dong DongJak-gu, Seoul 156-824, Republic of Korea Phone: +82.2.3473.3353 Fax: +82.2.3473.3352 SOUTH AFRICA Franklin Electric South Africa (Pty) Limited P.O. Box 8136, Edengie, 1613 13 Engwena Road, Sebenza, Edenvale, 161 South Africa Phone: +27.11.723.65 Fax: +27.11.69.2417 AUSTRALIA / NEW ZEALAND Franklin Electric (Australia) Pty. Ltd. 16-11 Micro Circuit Dandenong South, Victoria 3175 Australia Phone: +61.3.9799.5 Fax: +61.3.9799.55 Hotline: 1.3 FRANKLIN (1.3.372.655) EUROPE/MID-EAST/N. AFRICA Franklin Electric Europa GmbH Rudolf-Diesel-Straße 2 D-54516 Wittlich, Germany Phone: +49.6571.15. Fax: +49.6571.15.51 JAPAN Franklin Electric International, Inc. Aoba Bldg. 4F 1-14-7, Sugamo Toshima-Ku, Tokyo 17-2, Japan Phone: +81.3.5319.1251 Fax: +81.3.5319.1252 LATIN AMERICA Motores Franklin S.A. de C.V. Avenida Churubusco #16 (Bodega #16) Col. Francisco I. Madero Monterrey, N.L. Mexico C.P. 6456 Phone: +52.81.8.1 Fax: +52.818.864.8445 UNITED STATES Franklin Electric Co., Inc. 4 E. Spring St., Bluffton, IN 46714 USA Phone: +1.26.824.29 Fax: +1.26.824.299 www.franklin-electric.com M168 6.12