Sanitary Sewer Design and Modeling Workshop



Similar documents
2.0 BASIC CONCEPTS OF OPEN CHANNEL FLOW MEASUREMENT

CHAPTER 9 CHANNELS APPENDIX A. Hydraulic Design Equations for Open Channel Flow

Appendix 4-C. Open Channel Theory

CHAPTER 3 STORM DRAINAGE SYSTEMS

Open Channel Flow 2F-2. A. Introduction. B. Definitions. Design Manual Chapter 2 - Stormwater 2F - Open Channel Flow

STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION DRAINAGE HANDBOOK OPEN CHANNEL. OFFICE OF DESIGN, DRAINAGE SECTION November 2009 TALLAHASSEE, FLORIDA

Module 9: Basics of Pumps and Hydraulics Instructor Guide

Topic 8: Open Channel Flow

OPEN-CHANNEL FLOW. Free surface. P atm

What is the most obvious difference between pipe flow and open channel flow????????????? (in terms of flow conditions and energy situation)

Open Channel Flow. M. Siavashi. School of Mechanical Engineering Iran University of Science and Technology

COMBINED SEWER OVERFLOW OPERATIONAL AND MAINTENANCE PLAN SUMMARY

Chapter 13 OPEN-CHANNEL FLOW

M6a: Open Channel Flow (Manning s Equation, Partially Flowing Pipes, and Specific Energy)

Note: first and second stops will be reversed. Bring clothing and shoes suitable for walking on rough ground.

CITY UTILITIES DESIGN STANDARDS MANUAL

Experiment (13): Flow channel

Hydraulic Jumps and Non-uniform Open Channel Flow, Course #507. Presented by: PDH Enterprises, LLC PO Box 942 Morrisville, NC

STORM DRAINS CHAPTER 7

CLARK COUNTY REGIONAL FLOOD CONTROL DISTRICT HYDROLOGIC CRITERIA AND DRAINAGE DESIGN MANUAL SECTION 800 STORM SEWER SYSTEMS TABLE OF CONTENTS

2O-1 Channel Types and Structures

Module 7: Hydraulic Design of Sewers and Storm Water Drains. Lecture 7 : Hydraulic Design of Sewers and Storm Water Drains

CHAPTER 4 STORM DRAINAGE SYSTEMS

Basic Hydraulic Principles

CHAPTER 2 HYDRAULICS OF SEWERS

6-1 Introduction. 1. Storm drain that does not require pressure testing. 2. Lateral that does not require pressure testing.

Experiment 3 Pipe Friction

Environmental Data Management Programs

Travel Time. Computation of travel time and time of concentration. Factors affecting time of concentration. Surface roughness

CEE 370 Fall Laboratory #3 Open Channel Flow

Open channel flow Basic principle

21. Channel flow III ( )

Chapter 2. Derivation of the Equations of Open Channel Flow. 2.1 General Considerations

SECTION 5 - STORM DRAINS

How To Model Hydrology

Sanitary Sewer Overflow (SSO) Incident Report Form

Lecture 24 Flumes & Channel Transitions. I. General Characteristics of Flumes. Flumes are often used:

Scattergraph Principles and Practice Characterization of Sanitary Sewer and Combined Sewer Overflows

Chapter 9. Steady Flow in Open channels

DIVISION OF WATER QUALITY CONSTRUCTION GRANTS & LOANS SECTION FAST TRACK AUDIT CHECKLIST

DRAFT Public Outreach Document for What s an SSMP?

SANITARY SEWER SPECIFICATIONS

Floodplain Hydraulics! Hydrology and Floodplain Analysis Dr. Philip Bedient

Design Charts for Open-Channel Flow HDS 3 August 1961

DESCRIPTION OF STORMWATER STRUCTURAL CONTROLS IN MS4 PERMITS

Texas Commission on Environmental Quality Page 1 Chapter Design Criteria for Domestic Wastewater Systems

CITY OF SALEM DEPARTMENT OF PUBLIC WORKS ADMINISTRATIVE RULES CHAPTER 109 DIVISION 003 SANITARY SEWER COLLECTION SYSTEM

FLOW CONDITIONER DESIGN FOR IMPROVING OPEN CHANNEL FLOW MEASUREMENT ACCURACY FROM A SONTEK ARGONAUT-SW

Fort Dodge Stormwater Master Planning. Prepared By: Ralph C. Stark, Jr., P.E., C.F.M. Joel N. Krause, P.E., C.F.M.

Open Channel Flow Measurement Weirs and Flumes

APPENDIX M-2 SANITARY SEWER TECHNICAL MEMORANDUM. Stadium Reconstruction EIR

Collection Systems 2005 Sustaining Aging Infrastructure: System, Workforce and Funding

Application of InfoWorks CS Software for the Hydraulic Design of HATS Stage 2 Sewage Conveyance System in Hong Kong, China

Chapter 7 Ditches and Channels

ecmar SECTION INSTRUCTIONS: Sanitary Sewer Collection Systems

Emergency Spillways (Sediment basins)

MIKE 21 FLOW MODEL HINTS AND RECOMMENDATIONS IN APPLICATIONS WITH SIGNIFICANT FLOODING AND DRYING

CHAPTER ONE Fluid Fundamentals

From Civil 3D, with Love

Civil Engineering Hydraulics Open Channel Flow. Adult: Where s your costume? What are you supposed to be?

GIS in Wastewater Collection System Master Planning

Micromanagement of Stormwater in a Combined Sewer Community for Wet Weather Control The Skokie Experience

Storm Drainage Systems

2011 HYDRAULICS MANUAL

Chapter 9 Storm Sewers

Pressure drop in pipes...

Basic Hydrology. Time of Concentration Methodology

CHAPTER 4 OPEN CHANNEL HYDRAULICS

EXAMPLES (OPEN-CHANNEL FLOW) AUTUMN 2015

HYDROVEX. CSO, SSO and Stormwater Management Specialist Products and Services for North America

SECTION 5 DRAFTING STANDARDS

PART 6 - STANDARD DESIGN AND CALCULATION FORMS 6.1 SANITARY SEWER DATA SHEET

Land Disturbance, Erosion Control and Stormwater Management Checklist. Walworth County Land Conservation Department

Engineering Specifications February, 2004 Schedule H to Bylaw 7452, Subdivision Bylaw Page 18

Geoprocessing Tools for Surface and Basement Flooding Analysis in SWMM

Sanitary Sewer Overflows Leave Telltale Signs in Depth-Velocity Scattergraphs

W13. Storm Drainage Layout with InRoads Storm & Sanitary. XM Edition TRN /0001

Type of Sewer Systems. Solomon Seyoum

Master Planning and Hydraulic Modeling

Home Drainage & Causes of Basement Flooding. Water

Town of Elkton & Cecil Soil Conservation District Checklist for Joint Agency Review Stormwater Management / Erosion and Sediment Control

Rational Method Hydrologic Calculations with Excel. Rational Method Hydrologic Calculations with Excel, Course #508. Presented by:

Review of Footing Drain Disconnection Projects

SECTION 5: SANITARY SEWER SYSTEM DESIGN

LECTURE 9: Open channel flow: Uniform flow, best hydraulic sections, energy principles, Froude number

Source Water Protection Practices Bulletin Managing Sanitary Sewer Overflows and Combined Sewer Overflows to Prevent Contamination of Drinking Water

Urban Hydraulics. 2.1 Basic Fluid Mechanics

Scattergraph Principles and Practice Practical Application of the Froude Number to Flow Monitor Data

Hydrologic Modeling using HEC-HMS

SECTION STORM DRAINAGE TABLE OF CONTENTS

Chapter 9 Sanitary Sewers

Performing a Steady Flow Analysis

DRAINAGE MANUAL CHAPTER VII STORM DRAINAGE SYSTEMS

Kansas City s Overflow Control Program

REHABILITATION METHOD FOR INCREASING FLOW VELOCITY AND REDUCING SEDIMENTATION

8.1.3 General Design Guidelines. The following guidelines shall be used when designing inlets along a street section:

USSD Workshop on Dam Break Analysis Applied to Tailings Dams

URBAN DRAINAGE CRITERIA

Chapter 8: Flow in Pipes

Transcription:

Sanitary Sewer Design and Modeling Workshop Featuring Bentley Systems SewerGEMS Slavco Velickov, PhD Bentley Systems

Scope Steady hydraulics Model building Unsteady hydraulics Hydrology Dry weather loading Sanitary sewers Combined Sewers Designing new systems Pumps and force mains Pressure sewers Transient analysis Monitoring/rehab Geospatial data Load building Water quality

Sanitary Sewer System Overview Convey wastewater to treatment In some cases stormwater is also conveyed Primary components are: gravity pipes connecting manholes or access chambers pump stations and pressure mains Most systems designed for gravity flow

Types of Conveyance Gravity flow Surcharged gravity flow Inverted siphons Pressure flow in force mains Pressure sewers Vacuum sewers

Applications of Collection Design System Models Long-range master planning Rehabilitation studies Operational problems Regulatory compliance What if? scenarios

Temporal Considerations Steady State Used for design work Typically concerned with extreme conditions Snap shots of the system in time Unsteady (extended period) Used when pumps cycling or storage in system are significant Routing hydrographs through system

The Modeling Process Select Modeling Software Learn Software Develop Alternatives Document Results Define Scope Of Project Prepare System Description Enter System Data Initial Model Calibrated Model Apply Model Develop Solution Obtain Loading Data Enter Loading Data Refine Alternatives Store Model Collect Calibration Data Verify Data

Open Channel Flow Types of Flow Flow with free surface exposed to atmosphere Pressure or Pipe Flow Flow in closed conduit under pressure

Incompressible Turbulent Newtonian Fluid Wastewater Obeys Newton s Law of Viscosity In typical wastewater, solids don t significantly affect viscosity Waste activated sludge still Newtonian Thickened sludge not Newtonian

Volume/time FLOW m 3 /s cubic metres/second (SI) L/s litres/second m 3 /hr cubic metres/hour ft 3 /s cubic feet/second (FPS) gpm gallons/minute MGD million gallons/day ac-ft/day acre-feet/day cufr/frtnt - cubic furlongs/fortnight

PRESSURE Force/Area Newton/square metre - Pascal (SI) kpa kilopascal bar 100 kpa psf pound/square foot (FPS) psi pound/square inch (US typical) atm atmosphere (14.7 psi) pound? Gage vs. absolute

Flow Classification Scheme Uniform Nonuninform Steady Normal depth Long channel Manholes Backwater Unsteady Pump cycling Wet weather

Conservation Equations Conservation Principles Mass Energy Conservation of Mass requires that Inflow - Outflow = Rate of change in storage If Inflow = Outflow, no storage occurs If Inflow > Outflow, excess is stored If Inflow < Outflow, water level drops

Velocity and Flow Velocities vary across flow giving a velocity profile. In practical applications, average velocity can be used: V = Q A V = average fluid velocity Q = pipeline flow rate A = cross-sectional area of flow Substituting the cross-sectional area of a full circular pipe the equation becomes: V = 4Q πd 2 D = diameter

Conservation of Energy Water flows from a region of higher energy to a region of lower energy Energy terms are typically expressed as head Consider the energy terms for pressurized pipe flow

Conservation of Energy For steady, incompressible full pipe flow steady P 2 2 1 v 1 P 2 v + z + = + z + 2 1 2 γ 2g γ 2g + h f p = fluid pressure γ = specific weight of fluid Z = elevation above an arbitrary datum plane V = fluid velocity, averaged over a cross-section g = acceleration of gravity h f = headloss due to friction

Conservation of Energy For open channel flow, pressure head is expressed in terms of depth of flow (y) The energy equation for open channel flow is: 2 v 1 y 1 + z 1 + = 2g y 2 + z 2 + v 2g 2 2 + h f

Energy Grade Lines Total energy at-a-point in the fluid system Pipe flow: EGL= P + z + γ 2 v 2g Open channel flow: 2 v EGL= y +z + 2g

Hydraulic Grade Lines Sum of the pressure and elevation head terms at-a-point Pipe flow : HGL = P γ + z Open channel: HGL = y + z

Friction Head Loss Equations Energy is used to overcome friction and/turbulence Several equations are available to calculate head loss: Manning Darcy-Weisbach Kutter/Chezy Hazen-Williams Most head losses is wall friction Minor losses often small in comparison

Manning s Equation Most commonly used in US Q = k n A R 2 / 3 h S 1/ 2 k = 1.49 for U.S. customary units and 1.0 for SI units A = cross sectional area of flow R h = Hydraulic radius S = slope of the energy line = S o for uniform flow n = Manning s roughness coefficient

Manning s Equation Manning s n-value is viewed as a roughness coefficient, but it is actually influenced by many factors: Wall roughness Viscosity Diameter Velocity Depth of flow Obstructions Stage and Discharge Silting and Scouring

Darcy-Weisbach Equation Widely used theoretically correct h = f f = f L D v 2 2g h f = headloss f = Darcy-Weisbach friction factor L = pipe length V = average pipe velocity g = gravitational constant

Moody Diagram f e/d Reynolds Numbe

Kutter/Chezy Equation Sometimes used in various parts of the world V = C R h S V = Mean velocity (ft/s, m/s) C = Roughness coefficient R = Hydraulic radius (ft, m) S = Friction slope (ft/ft, m/m)

Hazen-Williams Equation Frequently used in North America for pressure h L = C C L f 1.852 Q 1.852 4.87 D h L = pipe friction head loss L = pipe length C = Hazen-Williams C factor D = diameter Q = flow rate C f = unit conversion factor

Minor Losses Any feature that causes the flow to accelerate, decelerate, change direction, or change crosssectional area results in loss of energy. Minor losses typically occur in sewer systems at manholes h M = K M v 2 2g h m = the minor head loss K m = a minor loss coefficient

Minor Losses Minor losses occur at manholes, where there are entrance and exit losses and changes in flow direction Values of K m for manholes range from 0.5 to 1.0 Methods for calculating junction losses in SewerCAD Absolute Standard Generic HEC-22 Energy AASHTO

Specific Energy Specific Energy (E) - total energy at-a-point (cross-section) in open channel flow with respect to channel bed: E = y + v 2 2g For a given discharge Q = V*A 2 Q E = y + 2 2g A

Specific Energy Plot of the depth of flow vs. specific energy for a 12 inch pipe (y c is the critical depth) 1.0 0.8 y c = 0.74 Q = 3.0 0.6 y - ft 0.4 0.2 y c = 0.42 y c = 0.29 Q = 0.5 Q = 1.0 0.0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 Specific Energy - ft

Froude Number Dimensionless parameter to classify open channel flow The Froude Number is equal to 1 at critical depth F = V gd h Classification of flow: Depth of flow is higher than y c, F < 1, flow is subcritical Depth of flow is equal to y c, F = 1, flow is critical Depth of flow is lower than y c, F > 1, flow is supercritical

Non-Uniform Flow Most channels are non-prismatic Sanitary sewers are non-prismatic due to Presence of manholes Changes in pipe diameter, slope and direction Flow may be non-uniform in a prismatic channel due to the influence of a control Backwater created by a high tailwater depth Drawdown at a free outfall

Control A channel feature (structural) with a unique (1:1) relationship between depth and discharge Free overfall at the end of a mild channel Weirs and Flumes (critical controls) Long prismatic channel (control reach) Regulates (controls) the state of flow Subcritical flow is controlled by downstream conditions Supercritical flow is controlled by upstream conditions

Nonuniform flow controls Weir Change in slope

Channel Classification Channel bed slopes are classified hydraulically as mild, steep, critical, horizontal or adverse For a given flow rate, the bed slope is called: Mild if y n > y c Steep if y c > y n Critical if y n = y c

Assembling the Model

Data Requirements Network layout (system data) Hydraulic properties Sanitary flows (dry weather) Inflow and infiltration (wet weather) Operation data Calibration data

Network Data- System Layout Data coordinates of each pipe segment and manhole locations of wet wells, pumps, appurtenances pipe connectivity, lengths pipe diameters, materials pipe invert levels and manhole elevations Data Sources maps paper/cad construction/as-built drawings corporate GIS system asset-management systems work orders field survey

Hydraulic Properties Data pipe roughness pump curves Data Sources manufacturers specifications contractor submittals literature values field tests

Sanitary Flows- Dry Weather Data location of each source min, max, mean daily flows diurnal patterns projections Data Sources metering maps, aerial photos census data

Inflow and Infiltration- Wet Weather Data infiltration rate for each pipe segment or sub-basin locations of inflows quantities of inflow Data Sources field inspection measurements analysis of treatment plant flows hydrologic analysis literature values

Operation Data Data settings for pump operation settings of flow-control structures control strategies outlet controls Data Sources interviews with operations personnel operations records and manuals field inspection

Calibration Data Data recorded depth, rate of flow frequency/locations of overflows Precipitation data Data Sources field inspection and measurements operations records weather records flow-monitoring program

Types of Simulations Steady EPS Dry Sizing, Good system Design Check Wet Sizing, I/I system Overflows, troubleshooting

Defining Gravity Pipes Internal diameter Length (schematic or scaled) Material Roughness as Manning's n Shape Invert elevations (set to upstream/downstream pipe) Number of sections

Siphons (Depressed sewers) Designed dip in a gravity sewer Occurs when sewer must pass under structures Sewer line is below the HGL, full, and under pressure Designed with smaller pipes to maintain self-cleaning velocities

Defining Manholes Invert elevation- bottom of pipe entering manhole Rim elevation Structure size- common diameter in US is 4 ft Drop manhole- incoming sewage transported down vertical shaft

Junction Chamber Model special underground structures No loading Input parameters necessary to physically define a junction chamber are: Coordinates Ground Elevation Structure Diameter Top Elevation Bottom Elevation

Defining Outlets Represents treatment plant, pump station, CSO, SSO or end of study area Specify tailwater depth Known tailwater Full pipe Critical depth Critical depth appropriate when pipe freely discharges

MODELING PRACTICE Data Entry Frequent checking Trial runs and GUI can show major data entry errors Using Model Plan runs before you make them Try different scenarios and alternatives Keep track of runs and backup files Ongoing Practices Large initial investment in modeling and training Keep good records Hit by a truck principle - so train others

TRADITIONAL METHOD OF MANAGING RUNS Input File Input File 1 Output File 1 Input File 2 Output File 2 MODEL Input File 3 Output File 3 Input File 4 Output File 4 Input File 5 Output File 5 Output File Input File 6 Output File 6 Input File 7 Output File 7 Input File 8 Output File 8 Input File 9. Output File 9..

SCENARIO MANAGER TERMINOLOGY Scenario = single run of model contains type of run pointers to alternative data Alternatives = data set building block of scenarios Inheritance = building alternatives and scenarios from previous

Create New Scenario SCENARIO MANAGER Scenario Cycle Build Model (Base Scenario) Calculate Scenario Add/Modify Alternatives Review Results Alternatives -Topology -Physical -Boundary Conditions -Initial Conditions -Hydrology -Output -Rainfall runoff -Water quality -User data extensions

TOPOLOGICAL ALTERNATIVES Make individual elements active or inactive Great for future scenarios

Getting at Results Property grid Flex tables Graphing Color coding Annotation Profiling

Managers Scenario Alternatives Calc Options Graphs Profiles Symbology Animation Selection sets Queries Drawing navigator Backgrounds Prototypes Flex Tables

Unsteady Flow Hydraulics

What does SewerGEMS do? Given: System map Physical properties Loading data (Water Quality) Determines: Flow, velocity, depth in each conduit Level in each manhole, pond, tank (water Quality)

Evolution of Models Sanitary Stormwater Steady State Simple Routing SewerCAD StormCAD SewerCAD Pond Pack EPS StormCAD Fully Dynamic (St. Venant) SewerGEMS Civil Storm

Elements Point Manhole Pressure junction Cross section Junction chamber Catch basin Pump Wet well Pond outlet Outfall Line Conduit Channel Pressure pipe Gutter Polygon Catchment Pond

Basic Principles Conservation of Mass S( t + t) = S( t) + I ( t) t Q( t) t Conservation of Energy y v 2g 2 1 1 + z1 + = y 2 + z 2 + 2 v2 2g + h f Manning s Q = k n A R 2/3 h S 1/ 2

Pumps cycling Wet weather I/I Batch processes What Causes Unsteady Flow? Normal diurnal water use variation Occurs in sanitary, combined and stormwater systems

Unsteady Flow Can t just slide hydrograph downstream Increase in flow shows up as Increase outflow Increase depth (horizontal storage) Depends on nature of system

Hydrograph Routing Short distance Steep slope Flow Long distance Mild slope Time

Hydrologic Mukingum Puls Kinematic wave Convex Hydraulic St. Venant equations Routing Methods

Fully dynamic model? Solves full St. Venant equations for 1-D flow in open channels y u y Continuity = 0 + + x y u x u y t y 0 ) ( = + + S x S f g x y g x u u t u ) Momentum

Normal Depth B 1 cfs A 1 cfs

Gradually varied surcharged flow HGL B 2 cfs A 2 cfs

Overflow HGL 1 cfs B 3 cfs A 2 cfs

Backup HGL 4 cfs B 3 cfs A 1 cfs

Bentley Dynamic Models Solve full St. Venant equations Use stable implicit finite difference solution Based on FLDWAV Routes hydrographs Handles surcharging, overflows, backups Handles pipes, channels, ponds, pumps Used in CSD, SewerGEMS

Special Situations Surcharging Dry pipes Drop structures Pump cycling

Handling Pressure Flow

Start Type Can start with dry pipe Can warm-up model up to time 0 Warm up time depends on system Experiment to find best warm up Q t

Avoid very short pipes Convergence Tips Make computation time step shorter Move N-R weighting coefficient closer to one Decrease computation distance Test with no weir flow

Graphing A Picture is Worth 10 3 Words

Single Element Over Time Shows one attribute for one element over time

Scenario Comparison over Time Used to compare single attribute over time between scenarios

Element Comparison over Time Compare attribute for an element over time for single scenario

Element Scenario over Time Can include different elements and scenarios for a single attribute over time

Graphing Controls Graph Series Option (SewerGEMS choices) Attribute (fields) Element Scenario Chart Options (Graphics choices) Chart tab Axis, title, legend Click on individual series properties Series tab Format, marks

Graphing Tips Checking/unchecking visible turns things on/off Default for legend is outside; use custom to move inside Set display number of digits in data tab or in options Background under panel tab Marks refers to placing actual value on graph There is no Undo ; Save work frequently

Terminology Title Subtitle Mark Axis Title Axis Label 2000 Foot Panel Series

Dynamic Wave Routing Because life is dynamic

Sanitary Systems

Sanitary Sewer Systems Designed for sanitary loads Should be minimal wet weather I/I Inflow / Infiltration Problems usually caused by I/I Must understand dry weather flow I/I enters through defects Manholes Joints Illegal connections

System design Sanitary Sewer Modeling System capacity analysis Steady, gradually varied flow analysis Overflows Compliance with Capacity management operation and maintenance (CMOM)

Sanitary Sewer Design Dendritic layout Controlled by Loading Min and max slopes Right of way and conflicts Min pipe size usually 8 in.

Sanitary Sewer Overflows SSO not permitted Understand cause (SSO) Maintenance (roots, grease) Lack of capacity (growth) RDII (wet weather only) Model can help identify cause, remedial action Combine modeling and monitoring

Solving Overflows Compare model with monitoring Find flow and hydraulic properties that match monitoring Propose solutions I/I control Increase capacity Storage Model proposed solutions

Dry Weather Loads Referred to as: Usage Demand Loading Loads are assigned to nodes Must add in wet weather loads Wide variety of data sources

PLACING LOADS AT NODES MH-35 MH-36 Q(load) << Q(in)

Steps in Loading Model Current year average day Peaking and temporal variations Wet weather flows Projections

Top Down System Production Large Users Subareas Nodal Load Nodal Nodal Nodal Nodal Load Load Load Load Customer Meter Records/ Unit Loads I/I? Bottom Up

Loading Projections Spatial and temporal population projections Usually provided by city or regional planners Get others to sign off on population projections Where will high growth be? Where will large water users be? Future water conservation and per capita usage rates Average Load Alternative loading projections 1960 1970 1980 1990 2000 2010 2020 2030

Year Population 2000 540 2010 635 2020 710 Planning District Drainage Divide Placing Projected Load Existing Pipes

Loading Methods in SewerGEMS Sanitary loading Hydrograph Unit load x count (with pattern) Base flow x pattern Inflow Fixed inflow Hydrograph Base flow x pattern Catchment runoff Pipe infiltration

Hydrograph Pattern Flow, cfs Multiplier Day 1 Day 2 Day 3 Day 1 Day 2 Day 3 Time Time

Unit Loading Unit load Home Restaurant per customer Office per employee Default values available User provides count (population) Pattern setup assigns pattern to load type

Patterns Multiplier x base flow Base on flow metering for dry day Assign patterns to nodes Few patterns, many nodes Repeat each period (24 hrs) Flow Time

Dry Weather Loading Patterns Define patterns by demand types: e.g. residential - industrial - commercial For large water users, use actual water use patterns Data logging Literature values can provide first guess very system specific Patterns can vary by season/day of week

Patterns: Stepwise or Continuous STEPWISE CONTINUOUS TIME

Typical Loading Patterns

Flow Balance For given time period Load = V(in) V(out) +/-Storage Define area where all flows and levels are known Flow = Usage/Time Multiplier = Flow/(Average Flow)

Combined Sewers Carry wastewater and stormwater Overflows permitted in wet weather No dry weather overflows Nine minimum controls

Key Terminology Types of Sewer Flow

Separate Sanitary Sewers

Combined Sewers

From System Typical CSO From System Weir To Treatment Control To Treatment To Overflow To Overflow

Nine Minimum Controls Proper O&M Maximize use of storage Modify pretreatment requirements Maximize flow to POTW Eliminate dry weather CSOs Control solids and floatables Pollution prevention Public notification of impacts Monitor impacts and controls

Modeling Diversions Dynamic waver calculates flow split Control structures (pipe property) Weir Orifice Functions Q = a(h-weir) b Depth vs. flow curve Stability issues small time steps Hydrologic routine rating table

Combined System Loading Uses both Inflow and Sanitary Sanitary - dry weather flow Inflow/Infiltration - wet weather flow

Modeling CSOs Determine magnitude of event that causes overflow Determine volume of overflow vs. event From event frequency, can identify overflow volume Long term simulation

Sewer separation Storage of wet weather flow CSO Solutions No new combined systems in EMEA Combined sewers common elsewhere Modeling important

Selection Sets Can define groups of elements for graphics or tables Useful for finding things in large models Can use queries to create sets View with Drawing Navigator

Selection sets can Be manually created Query Manager Query is used to Create selection sets Selection Set Manager Drawing Navigator Selection sets are used By drawing navigator to Determine elements for display

Questions and Answers Thank you