Standard Series Key features: Wide power range: 7.W-48W Universal input : 7.W-W: 8-264V /1-37V DC W: 8-2V /17-264V 24-37V DC (selectable) W, W, 24W: 8-264V /11-3V DC 48W: 3 phase: 32- V 3 phase: 3- V Overcurrent/overvoltage protection Power Factor Correction (W, W, 24W models) EN6-3-3 EN6-3-2 adjustment +1% Spring-up crew terminal, IP2 (finger-safe) DIN rail or panel surface mount Style Approvals: CE marked UL 8 Listed c-ul TÜV approved LVD EN9:2 Capacity 7. 1 3 EMC Directives: EN81-2 EN82-2 EN6-6-2 8 to 264V Standard Series Switching Rated Current Part Numbers Part Number V DC 1.A -A V DC.6A -A 24V DC.3A -A24 V DC 2.A -B V DC 1.2A -B 24V DC.6A -B24 V DC 2.A -C 24V DC 1.3A -C24 24V DC 2.1A -D24 Style UL 8 Listed File #E177168 Capacity Cert No. BL982332392 8 to 264V Rated Current Part Number 24V DC 3.1A -Q24 24V DC 4.2A -E24 to 24V 24V DC A -F24 24 24V DC 1A -G24 48 32 to V (3 phase) 3 to V (2 phase) 24V DC 2A -TJ24* * 3-Phase OI Touchscreens PLCs Automation Software Sensors Communication Barriers 8-262-IDEC (4332) USA & Canada 161
Standard Series Specifications Barriers Communication Sensors Automation Software PLCs OI Touchscreens -A -B* Model -A -B -C -A24 -B24 -C24 -D24 -Q24 -E24 -F24 -G24 -TJ24 Capacity 7.W 1W 3W W W W W 24W 48W (singlephase, 2-wire) to 24V nominal (8 to 264V ), /Hz (47 to 63Hz) 11 to 34V DC nominal (1 to 37V DC) to V, /Hz 2 to 24V, /Hz (jumper selectable) 24 to 37V DC 2.A at V 1.A at 2V to 24V, /Hz, 11 to 34V DC.17A at.3a at.68a at V 1.1A at 1.1A at 1.8A at Current (typical) 4A at V V V V V V Internal Fuse Rating 2A 2A 3.1A 3.1A 3.1A 4A 4A 6.3A 7A maximum A maximum (at 7A maximum (at cold start at Inrush Current A maximum (at cold start at 2V ) (at cold start at cold start at 2V 23V ) 23V ) ) Leakage Current (at no load) Typical Efficiency Overvoltage Protection and Current Ratings V, 1.A V,.6A 24V,.3A 69% at V % at V 79% at 24V V, 2.A V, 1.2A 24V,.6A.mA maximum (Hz, measured in conformance with UL, CSA, VDE) % at V % at 24V V, 2.A 24V, 1.3A 3 phase: 32 to V 2 phase: 3 to V 3 x 1.1A 3 x.8a 79% at 24V 83% at 24V 8% at 24V 83% at 24V 91% s turns off at 1% (typical) 21A na <3.ml 24V, 2.1A 24V, 3.1A 24V, 4.2A 24V, A 24V, 1A 24V, 2A Adjustments ±1% ( screw on top) Holding Time 2ms minimum (at full rated input and output) 1ms typical Rise Time 2ms maximum (at full rated input and output) 1ms max.? Line Regulation.4% maximum 1.% max Load Regulation 1.% maximum 2.% max Fluctuation due to Ambient Temperature Change.% maximum Ripple 2% peak to peak maximum (including noise) < 1mVpp Overload Protection % typical (Zener-limiting) % typical, auto reset % typical, auto reset Operation Indicator LED (green) Parallel Operation -A -B -C -D -Q -E -F -G Allowed No Yes No Yes Yes Between input and output terminals: 3,V, 1 minute Dielectric Strength Between input terminals and housing: 2,V, 1 minute Between output terminal and housing: V, 1 minute Insulation Resistance Between input and output terminals/input terminals and housing: MΩ minimum (V DC megger) 2kV, V DG Operating Temperature 1 to + C (14 to 14 F) (see derating curves) -2 to +7 C Storage Temperature 3 to +8 C (-22 to 18 F) -4 to +8 C Operating Humidity 2 to % relative humidity (no condensation) 9% max (at 2 C, no condensation) <1Hz amplitude +/- 2.mm in Vibration Resistance 4m/s 2, 1 to Hz, 2 hours on each of 3 axes 1 to Hz,.mm p-p, 2 hrs on each of 3 axes accordance with IEC 68-2-6 1 to 1Hz, 2.3g, min. 3g in all Shock Resistance 3m/s 2 (3G), 3 shocks in each of 6 directions directions in accordance with IEC 68-2-27 Approvals Conforms to EMC Directives EN81-2 & EN82-2. LVD Directive EN29 Certified to EN9. UL8 listed. c-ul, TUV approved. CE marked. EN6-3-2 Weight 1g 17g 3g 3g 8g g g 2g 2g Termination Spring-up, fingersafe terminals with captive M3. screws IP protection IP2 (finger safe) Dimensions H x W x D (mm) x 4 x 7 x 4 x9 x x 9 x x 9 x 8 x 14 x 14 x 9 x 11 x14 x 2x 14 x 11 x 12. Dimensions H x W x D (inches) 2.9 x 1.77 x 2.76 2.9 x 3.4 x 2.9 x 3.4 4.72 x 3.3 x 4.72 x 4.3 x 4.72 x 7.87 x 2.9 x 1.77 x 3.74 2.9 x.71 x 3.74 3.74 x 3.74.2.2.1. x 4.3 x 6. 1. For dimensions, see page 16. 2. For usage instructions, see page 164. 3. *.W for VDC model. 162 www.idec.com
Standard Series -A/B 8 7 4 3 2 1 1 1 2 3 4 -E 8 7 4 3 2 1-1 -F/G 1 2 3 4 Operating Temperature ( C) Mounting Style B Mounting Style A 8 7 4 3 2 1 1 2 3 3 4 A Mounting (standard) B Mounting (Facing Upward) Vertical Vertical Temperature Derating Curves -C/D 8 7 4 3 2 1 1 1 2 3 3 4 -Q Current (A) Mouting style A 8 7 4 3 2 1 1 2 3 4 -TJ 8 7 I w 4 3 2 1 1 2 3 4 7 Ambient Temperature (C) OI Touchscreens PLCs Automation Software Sensors Communication Barriers 8-262-IDEC (4332) USA & Canada 163
Standard Series OI Touchscreens Accessories Part Numbers: Accessories Appearance Description Part Number DIN rail (mm) BNDN Overcurrent Protection Characteristics -A/B (%) PLCs DIN rail end clip BNL 1 Installation Instructions -C/D/E Time-Saving Spring-up Terminals Automation Software The innovative terminals on the series use a spring-loaded screw. This makes installation as easy as pushing down and turning with a screwdriver. Installation time is cut in half since the screws do not need to be backed out to install wiring. The screws are held captive once installed and are % finger-safe. Screw terminals accept bare wire or ring or fork connectors. 1. Insert the wire connector into the slot on the side of the power supply. (%) 1 Sensors 2. Using a flat head or Phillips screwdriver, push down and turn the screw. The wire is now connected, and the screw terminal is fingersafe! Front Panel (terminals) Markings Name Description V. ADJ adjustment Operation indicator Adjusts within ±1%; turn clockwise to increase output voltage Green LED is lit when output voltage is on + - Parallel Operation TERMINALS Communication +V, V L, N DC output terminals Frame ground terminals No connection +V: Positive output Terminal V: Negative output terminal Ground this terminal to reduce high-frequency currents caused by switching Accept a wide range of voltages and frequencies (no polarity at DC input) Do not insert wires here, as this may damage the power supply Barriers ELECTRICAL LOAD 1. Parallel operation only recommended for -Q24, -F24 and -G24. 2. Factory recommended diode ST Microelectronics BYV4V-, BYV4V-, BYV4V-2, BYV41V-2 or with equivalent electrical specifications. 3. Using the voltage adjustment make sure out-voltage is the same for all power supplies. 164 www.idec.com
Standard Series 62. R2.2 6-ø6. 3 38. 14 2-24V Dimensions -A (7.W) -B (1W) -C (3W) 1-ø6. 8 62. R2.2 6-ø6. 3 38. 8 4.6 1 2 11 11 26 11 1-ø6. -D (W) -Q (W) -F (W) -E (W) 14-ø6. Terminal Markings -A/B -C/D/Q/F/G -E -V +V L N V +V L N -G (24W) 8 16 1 11 11 V +V w-output -TJ24 VOLTAGE SELECT L N 2-24V -V 11 11 OI Touchscreens PLCs Automation Software Sensors Communication Barriers 2-24V 8-262-IDEC (4332) USA & Canada 16