A short description to the VABus protocol



Similar documents
SERIAL INTERFACE. Series SSW-03 and 04

ESPA Nov 1984 PROPOSAL FOR SERIAL DATA INTERFACE FOR PAGING EQUIPMENT CONTENTS 1. INTRODUCTION 2. CHARACTER DESCRIPTION

Development Kit EM4095 User s Manual

plc numbers Encoded values; BCD and ASCII Error detection; parity, gray code and checksums

DSP801 Operation Manual

Card Issuing Machine for Magnetic, Contact & IC Card

Z-1170BT V2 ( Version 1.01) User s Manual

How To Send A Message From A Computer To A Computer (Iwea) On A Microsoft Macbook 2.5 (Isoa) To A Microsatellite 2.4 (Ios) On An Unix (Ise

PROPERTY MANAGEMENT SYSTEM

4511 MODBUS RTU. Configuration Manual. HART transparent driver. No. 9107MCM100(1328)

MTS Master Custom Communications Protocol APPLICATION NOTES

Timeout The Crosspoint Status Request message has a timeout, which means that you need to wait 1 second in between request messages.

PFB366 Profibus-DP Gateway User Manual

The Answer to the 14 Most Frequently Asked Modbus Questions

Barcode Magstripe. Decoder & Scanner. Programming Manual

NG360 Inclinometer with digital RS485 communications port and 360 degree measuring range

RFID MODULE Mifare Reader / Writer SL025B User Manual Version 1.4 Nov 2012 StrongLink

Memory is implemented as an array of electronic switches

BRMO 80 / ETH-IP. User Manual. Réf : MU-BRMO 80-ETH-IP-1.4-EN

Applied Data Communication Lecture 14

RFID MODULE Mifare Reader / Writer SL031 User Manual Version 2.7 Nov 2012 StrongLink

TAP Interface Specifications

Xi2000 Series Configuration Guide

Operating Instructions Serial Monitor ROBERT RIELE GmbH & Co KG

GE Power Controls FIELDBUS APPENDIX PROFIBUS DP. Doc. No.: ASTAT Plus PB_Appendix-v0

HOST Embedded System. SLAVE EasyMDB interface. Reference Manual EasyMDB RS232-TTL. 1 Introduction

User Manual. AS-Interface Programmer

PM1122 INT DIGITAL INTERFACE REMOTE

Table 1 below is a complete list of MPTH commands with descriptions. Table 1 : MPTH Commands. Command Name Code Setting Value Description

Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide

Index...1. Introduction...3. Installation- Keyboard Wedge...3 RS USB...3. Default Setting for each barcode shown as below:...

1.Eastron SDM220Modbus Smart Meter Modbus Protocol Implementation V1.0

USER S MANUAL Communication Function

CB15/CB155. PROFIBUS Module

Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0

Arndt & Voß GmbH Elektronik - Meßtechnik

CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual

Model 200 / 250 / 260 Programming Guide

48,1;&RPPXQLFDWLRQ3URGXFWV

CMC-DN01 DeviceNet Slave Communication Card Operation Manual

CONCEPT1 RS232 COMMUNICATION

ASCII Code. Numerous codes were invented, including Émile Baudot's code (known as Baudot

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

Scanner Configuration

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

SPA-Bus Communication Protocol V2.5. Technical description

Network Operation and Troubleshooting

Modbus Communications for PanelView Terminals

Users Manual. QuickBarII Single-Chip Bar Code Decoder

RFID MODULE Mifare Reader / Writer SL032 User Manual Version 1.5 Nov 2012 StrongLink

This is great when speed is important and relatively few words are necessary, but Max would be a terrible language for writing a text editor.

MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual

Start-up of IVI-KHD2-4HRX, IVI-KHA6-4HRX at S7-300 V1.1. Table of Contents TABLE OF CONTENTS... 1

Elettronica dei Sistemi Digitali Costantino Giaconia SERIAL I/O COMMON PROTOCOLS

NHD-0420D3Z-FL-GBW-V3

SIMATIC. S7-300 PtP coupling and configuration of CP 340. Preface. Product Description 1. Basic Principles of Serial Data Transmission

Computer Control of Satellite Antennas

PRODUCT MANUAL SKX OPEN SKX ADVANCE ZN1RX-SKXOPEN. Edition 2 Version 1.1

ND48-RS ASCII A2.04 Communication Protocol

Experiments: Labview and RS232

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. Version 3.0

Meter Communication. Twisted Pair Baseband (M-Bus) Physical and Link Layer CEN TC 294. Date: TC 294 WI 006 CEN TC 294. Secretariat: AFNOR

Part Number Description Packages available

RDF1. RF Receiver Decoder. Features. Applications. Description. Ordering Information. Part Number Description Packages available

Introduction: Implementation of the MVI56-MCM module for modbus communications:

Interface Protocol v1.2

THE SERIALS DOTMATRIX DISPLAYS WITH RS-232

RS485 & Modbus Protocol Guide

CENTRONICS interface and Parallel Printer Port LPT

USART and Asynchronous Communication

Temp. & humidity Transmitter Instructions

Voyager 9520/40 Voyager GS9590 Eclipse 5145

Process Control and Automation using Modbus Protocol

ARLcom: Package of result transmission solutions

MSR605. Programmer s Manual. Magnetic Stripe Card Reader/Writer (High & Low Coercivity) Revision B

MODBUS RTU compatible master and slave driver for High Performance Controllers

NTAG213/215/216. The mechanical and electrical specifications of NTAG21x are tailored to meet the requirements of inlay and tag manufacturers.

RS-485 Protocol Manual

TELOCATOR ALPHANUMERIC PROTOCOL (TAP)

SureServo Communication Parameters SureServo Parameter Memory Addresses Connecting to DirectLogic PLCs...6 8

How To Communicate With A Netbook (Netbook) On A Computer Or Ipad (Networking) On An Ipad Or Ipa (Netcom) On The Network (Netrocessor) On Your Computer Or Computer On A Network

PRINTED MANUAL AGG Software (

Technical Support Bulletin Nr.18 Modbus Tips

S-TEC electronics AG KBOX P100. KBOX-Program P100 V0115. Hardware und Software engineering Industrielle Steuer- und Regeltechnik

KSH-3000-MI. Swipe Card Reader. ( Magnetic / IC Card two in One Reader ) Revision Reason Date V

1.1 Connection Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking

gammadue and deltadue controller series Serial communications and configuration software USER GUIDE M.I.U. CSG2-14/10.04 Cod. J ACS3 - ENG

Serial Communications / Protocol in AirTest Products

Original instructions. PLUTO Gateway. User Manual. PROFIBUS GATE-P1/P2 DeviceNet GATE-D1/D2 CANopen GATE-C1/C2 Ethernet GATE-E1/E2

Master-Touch and ValuMass. Modbus Communications. INSTRUCTION MANUAL (Rev. 2.1)

Industrial Networks & Databases

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

ATC-300+ Modbus Communications Guide

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

DRS-6/1 Doppler Radar Sensor

NOTICE: respective owner. Note: Specification is subject to changes without. notice.

Industrial Networks & Databases. Protocols and Networks - Device Bus - - Field Bus -

Numeral Systems. The number twenty-five can be represented in many ways: Decimal system (base 10): 25 Roman numerals:

Copyright All rights reserved. No warranty of any kind is made in regard to this material, including, but not limited to, implied warranties of

ECR-Interface ZVT-Protocol. Transport-Protocol Application-Protocol

Transcription:

A short description to the VABus protocol The VABus-protocol can be used with the CM-232 or the CM-485. 1. connectors...2 2. Baudrate...3 3. Node-Adress...3 4. Serial Port Defines...4 5. Control Characters...4 6. Protocoll...5 6.1 Enquiry-Telegramm...5 6.2 Select-Telegram f...5 6.3 inverter adresses...6 6.4 Binary Checksum BCC...7 6.5 Error handling...7 6.6 telegram / data length...7 7. Examples...8 8. PC / COM-Port setting...9 9. Inverter control...9 A short description to the VABus protocol 1

1. connectors Pinning X310 CM-232 Pin Signal 1-2 RxD 3 TxD 4-5 0V 6-7 - 8-9 - Pinning X310 CM-485 Pin Signal 1 B 2 B 3 0V 4-5 +5V 6-7 A 8 A 9 - Connection with shielded twisted pair.! Shield is to be connected to PE at both ends of the line. Note: When using the CM-485 the bus line must be terminated at both physical ends of the line. The termination resistor has the value 150R. The termination is activated by the DIP-switch on the CM-485 A short description to the VABus protocol 2

2. Baudrate The baudrate is set by the parameter Baudrate 10. Nr. Name Min. Default Max. 10 Baudrate 1 4 4 supported baudrates P. 10 Baudrate 1 2400 Baud 2 4800 Baud 3 9600 Baud 4 19200 Baud 3. Node-Adress The node-adress is set by the parameter RS232/RS485 NodeID 394. Nr. Name Min. Default Max. 394 RS232/RS485 NodeID 1 1 30 A short description to the VABus protocol 3

4. Serial Port Defines One character exists of: 1 Startbit 8 Informationsbits (7 Databits, 1 Paritybit) 1 Stopbit The startbit is followed by the least-significant-bit (LSB). Start b1 b2 b3 b4 b5 b6 b7 Parity Stop Parity = even Note: Only ASCII-characters are used. Be careful to the BCC. This can be any value. 5. Control Characters The listed control characters are used: Control- Name HEX-Value Character EOT End_Of_Transmission 0x04 ENQ Enquiry 0x05 STX Start_Of_Text 0x02 ETX End_Of_Text 0x03 ACK Acknowledge 0x06 NAK Negative_Acknowledge 0x15 A short description to the VABus protocol 4

6. Protocoll The protocoll is a Master/Slave-System. Two different telegrams are used: 6.1 Enquiry-Telegramm The bus-master asks for a parameter value. Bus-Master Inverter EOT ADR 0 p n n n ENQ Inverter Bus-Master ADR STX 0 p n n n a a w w w...... w w w ETX BCC in case of error ADR NAK Bus-Master Umrichter EOT 6.2 Select-Telegram f The bus-master sends a parameter value. Bus-Master Inverter EOT ADR STX 0 p n n n a a w w w... w w w ETX BCC Inverter Bus-Master ADR ACK in case of error ADR NAK Bus-Master Umrichter EOT ADR p nnn aa ww...www BCC inverter adress dataset-number parameter-number number of data following data binary checksum A short description to the VABus protocol 5

6.3 inverter adresses adress coding: adress (ASCII-) character HEX-value 1 A 41 2 B 42 3 C 43 4 D 44 5 E 45 6 F 46 7 G 47 8 H 48 9 I 49 10 J 4A 11 K 4B 12 L 4C 13 M 4D 14 N 4E 15 O 4F 16 P 50 17 Q 51 18 R 52 19 S 53 20 T 54 21 U 55 22 V 56 23 W 57 24 X 58 25 Y 59 26 Z 5A 27 [ 5B 28 \ 5C 29 ] 5D 30 ^ 5E 32** ` 60 ** = Broadcast-Adresse The broadcast adress can be used to send parameters simultaneous to all connected inverters by an enquiry telegram. In this case no answer ACK/NAK is send from the inverters. A short description to the VABus protocol 6

6.4 Binary Checksum BCC The binary checksum BCC exists of one byte who is calculated as EXOR of all bytes between STX (exclusive) and ETX (inclusive). ADR STX 0 p n n n a a w w w... w w w ETX BCC BCC = 0 EXOR p EXOR n...exor ETX EOT ADR STX 0 p n n n a a w w w... w w w ETX BCC BCC = 0 EXOR p EXOR n...exor ETX 6.5 Error handling In case of an NAK is received, then the error register (P.11) must be read first. The error register contains the error number. Before the error register is not read it is not possible to write any parameter to the inverter. error register error 0 no error 1 invalid parameter value 2 invalid data set 3 parameter can not be read (write-only) 4 parameter can not be written (read-only) 5 read error EEPROM 6 write error EEPROM 7 checksum error EEPROM 8 Parameter not writable while drive running 9 values of data sets different 10 wrong parameter type 11 unknown parameter 12 checksum-error in string String 13 syntax error in string 14 type of parameter and number of bytes in string do not fit 15 unknown error 6.6 telegram / data length The data field length depends on the parameter type. The data in the data field is allways HEX-ASCII. uint/int values 4 characters long values strings 8 characters number of characters = number of characters in string see examples A short description to the VABus protocol 7

7. Examples Reading parameter Fixed Frequency 2 481 dataset 0 from inverter with adress 1 (long value) Enquiry-Telegram Master Inverter EOT ADR 0 p n n n ENQ ASCII A 0 0 4 8 1 Hex- Value 04 41 30 30 34 38 31 05 Response Inverter Master ADR STX 0 p n n n a a w w w w w w w w ETX BCC ASCII Hex- Value A 0 0 4 8 1 0 8 0 0 0 0 0 3 E 8 H 41 02 30 30 34 38 31 30 38 30 30 30 30 30 33 45 38 03 48 The received value is hexadecimal 0x000003E8 = decimal 1000. The parameter Fixed Frequency 2 481 is 10,00 Hz. Reading parameter Fiexed Percent 1 520 dataset 2 from inverter with adress 10 (int value) Enquiry-Telegram Master Inverter EOT ADR 0 p n n n ENQ ASCII J 0 2 5 2 0 Hex- Value 04 4A 30 32 35 32 30 05 Response Inverter Master ADR STX 0 p n n n a a w w w w ETX BCC ASCII J 0 2 5 2 0 0 4 0 3 E 8 L Hex- Value 4A 02 30 32 35 32 30 30 34 30 33 45 38 03 4C The received value is hexadezcmal 0x03E8 = decimal 1000. The parameter Fiexed Percent1 520 is 10,00 %. A short description to the VABus protocol 8

8. PC / COM-Port setting C-Call for setting COM-Port (Windows): (void) setcom(com-port, Baudrate, EVEN,7,1); COM-Port port-number (1, 2, 3...) Baudrate 19200 (= ACT default) EVEN even parity 7 7 databits 1 1 stopbit 9. Inverter control For the inverter control the same functions can be used as described in the Profibus manual. The control word is equivalent to the parameter 410 (unsigned int, read/write). The state word is equivalent to the parameter 411 (unsigned int, read only). A short description to the VABus protocol 9