Multi Media Cable Tester TM-901N/TM-902/TM-903



Similar documents
Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

INSTRUCTION MANUAL. NC-500 NETcat Pro Wiring Tester

MICROMAPPER. Users Manual. LAN Wiremap Checker

MicroScanner 2. Users Manual. Cable Verifier

MULTI-FIELD EMF METER. TM-190 User s Manual B2TM

SC8108-A. NetWork Cable Tester. User Operation Manual. Taking Its Source At Sanling Science & Technology Good helper to network

MicroScanner 2. Cable Verifier. Getting Started Guide

5 in 1 Cable Tester RTK-T05 User Manual

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

Chapter 4 Connecting to the Internet through an ISP

TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

T7560A,B,C Digital Wall Module

Multipurpose LCD Display Cable Test & Inspection Instrument

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

AXIS T81B22 DC 30W Midspan

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

User Guide. Model Insulation Tester / Megohmmeter

AudioJoG (TM) Pro 8 Connector PIN LABEL LED Connector PIN LABEL LED. Operations Manual 3.5mm & 6.35mm Mono/Stereo Jacks

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Ground Resistance Clamp On Tester

User Guide. 4 wire Earth Resistance Tester Model GRT300

Manual Ranging MultiMeter

SMART SENSOR COLLECTION

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

HP ProCurve High-Speed Transceivers Installation Guide

Model UT33A: OPERATING MANUAL Table of Contents (1)

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

AutoRanging Digital MultiMeter

Setting Up the ZigBee Ethernet Gateway

TMS TANK MANAGEMENT SYSTEM

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

ES-3305P V2 / ES-3308P V2. Quick Installation Guide / v1.0

Drayton Digistat +2RF/+3RF

UT202A Operating Manual. Contents

Dual Laser InfraRed (IR) Thermometer

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

Home Security Alarm System

Advanced Systems Tester 900AST

This paper will explain some of the more important factors on how UTP wires work; specifically it will cover the following:

IFS SP-PoE Splitter User Manual

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Agilent U1230 Series Handheld Digital Multimeters (DMMs)

AVer EVC. Quick Installation Guide. Package Contents. 8. Mini Din 8 pin MIC Cable. 1. Main System. 9. HDMI Cable. 2. Camera. 10.

Safety Information. 2 Safety Information

SignalTEK II. Save money by using a single multifunction device in place of separate copper, fiber and Power over Ethernet (PoE) testers

CableIQTM. Users Manual. Qualification Tester

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

IEEE 802.3af 4-Port Power over Ethernet Injector Hub POE-400. User s Manual

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

User's Guide. Pinless Moisture Meter. Model MO257

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

USB/VGA Cat 5 UTP Console Extender

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Microwave Meter. Instruction Manual

COLOR TFT LCD MONITOR. User Manual

CableIQTM. Users Manual. Qualification Tester

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

RS DIGITAL THERMOMETER

KRONOS GA11 WEEKLY-PROGRAMMING DIGITAL CHRONOTHERMOSTAT FOR THE REMOTE CONTROL OF HOT AIR GENERATORS THROUGH BRAHMA INTERFACE BOARD APPLICATION

Dual Laser InfraRed (IR) Thermometer with Color Alert

Model 1756 Test Lead Kit

Dual Laser InfraRed (IR) Thermometer

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Hygro-Thermometer + InfraRed Thermometer Model RH101

CONSOLE REMOTE I /O AC 9V

SOLAR I-V Rel /07/10

How To Control A Battery Cell Phone With A Battery Power Control System

DC-8706K Auto Dial Alarm System

User Manual. Humidity-Temperature Chart Recorder. Model RH520

ADM1TE 5/30A DIN rail single phase two wire energy meter

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

VE02AL / VE05AL / VE02ALR VGA & Stereo Audio CAT5 Extender with Chainable Output

12 Volt 30 Amp Digital Solar Charge Controller

PiSector Home security systems

Thermistor Thermometer MODEL NO

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Energy Communication Unit (ECU)

LW A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets

Multi-Function Ground

Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Terminal and Dimension

GSM ALARM SYSTEM USER MANUAL

Mini InfraRed Thermometer with Laser Pointer

User's Guide. Integrating Sound Level Datalogger. Model Introduction

TRIPLETT TDR. Cable Fault Finder. Instruction Manual

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

Fluke 3000 FC Series Test Tools Technical Data

VoCALL - CFVCM/CFVCWM & CFVCX8. Fire Telephone & Disabled Refuge Network System. User Manual & Log Book

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

Model CFA-24 Transparent Cable Farm Automation Switch

Terminal and Dimension

Transcription:

Multi Media Cable Tester TM-901N/TM-902/TM-903 User Manual HB2TM9020010 TENMARS ELECTRONICS CO., LTD

Table of Contents 1 Introduction... 1 2 Safety Precaution... 1 3 The verifier does the following:... 2 4 Display Features... 3 5 Multi Media Cable Tester Features... 4 6 Testing Twisted Pair Cabling... 5 7 Twisted Pair Test Results... 6 Opens... 6 Shorts... 7 Miswires... 7 Split Pair... 8 8 Length measures... 9 9 SIGNALTONE measures(tm-903)... 10 10 Using Multiple Remote ID Locators...11 11 Auto power on and off setting mode... 12 12 Backlight on or off setting mode... 13 13 Changing Memory Number / Default Category /Types(UTP/STP) /Calibrating Length Measurements Value Parameter Options... 14 14 Checking the LCD and Software Version... 16 15 Battery Replacement... 17 16 Options and Accessories... 17 17 End of life... 17 18 Specifications... 18

1 TM-901N/TM-902/TM-903 1 Introduction The TM-902/TM-903 Multimedia Cable Tester (TM-901N LAN Cable Tester)is a hand-held test instrument that lets you verify and troubleshoot the Lan cable of twisted pair. 2 Safety Precaution CAUTION Be extremely careful for the following conditions while measuring Do not operate the meter under the environment with explosive gas (material), combustible gas (material) steam or filled with dust. In order to avoid reading incorrect data, please replace the battery immediately when the symbol appears on the LCD. In order to avoid the damage caused by contamination or static electricity, do not touch the circuit board before you take any adequate action. Operating Environment: Indoors use. This instrument has been designed for being

used in an environment of pollution degree 2. Operation Altitude: Up to 2000M. EMC: EN61326-1(2006), IEC 61000-4-2(2008, IEC 61000-4-3(2006) + (2007). 3 The verifier does the following: Detects opens, shorts, miswires and split pairs on twisted pair cabling. Displays graph wiremap, opens, shorts, miswires, split pairs, and the remote ID number all on one screen. Identify remote ID number only one pair. Measures length. Using multiple remote ID up to 8 locators. Low battery detector. Auto backlight. Auto power off. 2

4 Display Features TM-901N/TM-902/TM-903 1. Displays graph wiremap, opens, shorts, miswires, split pairs. 2. Displays Length and Unit. 3. Lower battery indication. 4. Enter the SETUP mode symbol. 5. Result displays, Pass,, split. 6. Displays remote ID number. 3

5 Multi Media Cable Tester Features 1. Power Key. 2. Setup function right Key. 3. Setting Key and Unit select Key 4. Test Key and Enter Key. 5. Setup function left Key. 6. Length and wiremap and signal-tone function key 4 7. RJ-45 connector socket. 8. F-Connector.(TM-903) 9. RJ-11 connector socket.(tm-903) 10. Remote ID locator. 11. RJ-45 connector socket of remote ID locator. 12. Tilt-stand. 13. Battery cover.

6 Testing Twisted Pair Cabling 1. Connect the meter and remote ID locator to the cabling as shown in Figures. 2. Press the key to power on. (TM-902/903) 3. Press key to measures wiremap and Remote ID Locators detect. 4. Display show some testing option as shown in Figures. 5

7 Twisted Pair Test Results The following figures show typical test results for twisted pair cabling. Any error occurs will show symbol on LCD. Opens Figure shows an open pair wire 4 and 5. 6

Shorts TM-901N/TM-902/TM-903 Figure shows tow short between wires 3, 4 and 5, another 1 and 8. When shorted occur, the verifier maybe not show open and miswires. Miswires Figure shows that wires 3 and 4 are crossed. The pin numbers order to indicate the fault. 7

Split Pair TM-901N/TM-902/TM-903 The following figure shows a split pair on 3, 6 and 4, 5. The split pair flashes to indicate the fault. LCD will show SPLIT indicate. In a split pair, continuity from end to end is correct, but is made with wires from different pairs. Split pairs cause excessive crosstalk that interferes with network operation. The spilt pair detects of cable must be at least 5 meter(15ft) in length. If open, short and miswires anyone occur, the spilt pair detects will don t work. 8

8 Length measures 1. Press the key to power on. 2. Press the L/W key(tm-901n/tm-902) or key(tm-903) to switch to Length (TM-903). 3. Press and Key to select show length pairs 1~4. 4. In the display length. Press the key to changing the length units, shown in Figure.. 9

9 SIGNALTONE measures(tm-903) 1. Press the key to power on. 2. Press the key to switch to SIGNALTONE. 3. Press the Key to select a different tone sequence displayed as the numbers 1~4 on LCD. 4. The function default continuity(lcd display C ) 5. If you want to changing, press the Key to select continuity (LCD display C ) to changing one-shot(lcd display F ),you can selection numbers 1~8. 6. Press the key to enable or disable out signal tone is cable tracing function. Toner is cable tracing function that assists in tracking cables hidden in walls. Ceilings, floors or patch panels by generating four distinct multi-tone signals that can be 10

received by a cable tracer. To trace a cable 10 Using Multiple Remote ID Locators Using multiple remote ID locators helps you identify multiple network cable connections, as shown in Figure. The display in Figure shows that the verifier is connected to the cable terminated with remote ID locator number 3. 11

11 Auto power on and off setting mode 1. Press the key to power on. 2. Press the key for more than 2 Second to enter Setting mode into setting mode. 3. Press the key again to auto power on or off setting. 4. Press the or key to change ON or OFF. 5. Press the key to enter and exit setting mode, shown in Figure.. 12

12 Backlight on or off setting mode Press the key to power on. Press the key for more than 2 Second to enter Setting mode into setting mode. Press the key setting to auto power on or off setting Press the key to backlight set Press the key again to backlight setting mod Press the key to change ON or OFF. Press the key to enter and exit setting mode, shown in Figure. 13

14 TM-901N/TM-902/TM-903 13 Changing Memory Number / Default Category /Types(UTP/STP) /Calibrating Length Measurements Value Parameter Options The meter to provide user self calibrate memory use number 1 ~ 9. User can order different cable type, category and length to acquire measurements value parameter. 1. Press the key to power on. 2. Press the key more than 2 second to and setting mode. 3. Press the key setting to auto power on or off setting Press the key to backlight set Press and key to select number zero from No.0~9. Press key again to setting flashes number. Press and key to select number zero from No.0~9. Press key to enter exit setting mode, 4. Press key into setting flashes cable

category, Press and key to setting cat 5 or cat 6,( RJ11,COAX.TM-903). 5. Press key again to setting flashes cable type. 6. Press key to select UTP or STP, Press key to enter exit setting mode shown in Figure. 7. Press the key more than 2 second to and setting mode. Press the key again to select setting flashes calibrating length measurements value parameter. 8. Press and key to select known length measurements value parameter. 15

9. Press key to enter and exit setting mode shown in Figure. 14 Checking the LCD and Software Version In the shutoff mode, Press and hold key again press the key to turn on meter and LCD will keep all dark continued. 16

15 Battery Replacement Turn off the meter and disconnect all test leads before replacing the battery. Use only the correct type of batteries, properly installed in the case, to power the meter. WARNING If the symbol appears on the LCD, please replace the battery immediately 16 Options and Accessories Consumers can order options and accessories as follows: Remote ID Locator Kit, numbers 2-8. 17 End of life Caution: this symbol indicates that equipment and its accessories shall be subject to a separate collection and correct disposal 17

18 Specifications Cable types tested : UTP, STP Cable Category tested : CAT5, CAT6 (RJ-11.COAX.TM-903 only). Test connectors : Shielded 8-pin modular jack (RJ45),test voice cable(rj11)tm-903,and video coax cable(f-connenector) TM-903. Wiremap test : Detects opens, shorts, miswires, split pairs Length test : Range : up to 255 m (836 ft) Resolution : 0.1 m (ft) Unit : meter and foot Typical accuracy : ± 10%+1.0m (3 ft) Display : 58mm(L) x45mm(w) Monochrome LCD with backlight Battery : 1.5Vx6 batteries (LR03 SIZE AAA 1.5V) Battery Lift : Approx continuous testing 200 times 18

Shutoff Rate Power :1uA Operate Maximum Power :20mA Operating temperature and humidity : 5 to 40,below 80% RH. Storage temperature and humidity : -10 to 60, below 70%. Dimensions : 156(L)*73(W)*35(H) mm. Weight : About 170g. Accessories : User s manual x1, 1.5V AAA battery x6, CAT5 STP Cable x1, remote ID(1) x1 19

Professional Electrical and Environment Test & Measurement Instruments: Battery Capacity / Impedance Tester LED light meter, Temperature & Humidity meter, Infrared Thermometer, Sound level meter Light meter, EMF meter, UV Light meter, RF meter, Hot wire Anemometer, CO meter Anemometer, Lan cable tester, CO 2 meter, Solar power meter, Radiation meter, Clamp meter, Multimeter, Phase Rotation test, Digital Insulation tester Our products of high quality are selling well all over the world TENMARS ELECTRONICS CO., LTD 6F, 586, RUI GUANG ROAD, NEIHU, TAIPEI 114, TAIWAN. E-mail: service@tenmars.com http: //www.tenmars.com