Electronic Pressure Independent Control Valve. Technical Databook. Belimo Actuators Ltd.

Similar documents
Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Type overview. Technical data

Overview of types. Technical data

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Electric Rotary Actuator - On/Off or programmable control actuator

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point

Characterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, and power and energy-monitoring function

Belimo Gateway MP to Modbus RTU - UK24MOD

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Air damper actuators

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

VAV system solution for non-pressure-dependent applications in enclosed spaces

Series 6000 Torque measured metal bellow coupling

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Butterfly Valves PN 6/10/16 for flanged connection

EBS852 (Contrac) Power Electronic Unit

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

How To Use A Flowmeter

Actuator for modulating control AME 435

RM4TG20 three-phase network control relay RM4-T - range V

HERZ-Thermal Actuators

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Electronic Control Devices The European Product Catalogue 2007

Quick Connect. quick - simple - efficient.

Characterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, power control, and power and energy-monitoring function

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

2- and 3-port valves with flanged connections, PN 10

Electronic Control Devices The European Product Catalogue 2007

SINEAX U553 Transducer for AC Voltage

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Heating, air-conditioning, cooling

Assisted lift operated 2/2-way solenoid valves Type EV250B

Adjustable room thermostat for heating only or cooling only systems

Voltage Regulator SPAU 341 C. Product Guide

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Frequency Converter Fv

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

T U R B I N E G A S M E T E R

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Hydraulic Control Solutions

Digital input modules

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Safety technique. Emergency stop module BO 5988 safemaster

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

AMTRON E-30 Compact heat and cooling meter

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

Duct Humidity Transmitter

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Products no longer available

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Series 7500 Torque Sensor

ABB i-bus KNX SA/S Switch Actuators Product Manual

38 Series - Relay interface modules A

HYDRUS ULTRASONIC METER

Digital inductive conductivity transmitter

Vario-Series Accessories

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

DS 600. A contact free flux gate based current measurement sensor 600A rms

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

PNOZsigma - Base units

Analogue + IVS Electronic Throttle Controls for CUMMINS Engines

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

3/2-way Solenoid Valve, direct-acting, NC or NO

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

Combi switchbox with integrated 3/2 way pilot valve

Operating instructions

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

Electronic Pressure Switch EDS 300

Thyristor-controlled power supplies and battery chargers

VE 210. Velocity transducer for low-frequency measurements. » From the Vibro-Meter product line» Low-frequency compensation allows frequency

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

38 Series - Relay interface modules A

SMOKE DAMPERS IMOS DKI-1 TECHNICAL CONDITIONS TPI (DAMPERS FOR EMISSION EXHAUST) FOR ONE FIRE AREA

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

VAV compact controller KNX / PL-Link

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Valve Remote Control Systems Centralized Hydraulics for marine vessels and offshore installations

Cable Plug acc. to DIN EN , Form A

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Heating Controller. Building Technologies HVAC Products

Transcription:

Electronic Pressure Independent Control Valve echnical Databook Ver. Version 2 1 Belimo Actuators Ltd.

Product overview/contents he Electronic Pressure Independent Valve and Rotary Actuators for modulating V [l/s] [mm] DN [inches] Valve and Sensor Frequency Rotary actuator 8.0 65 1 2 2" EPIV-65-800 8.0 65 1 2 2" EPIV-65-800-60 50Hz 60Hz SR24 - PI - 65 11.33 11.33 80 80 3" 3" EPIV-80-1140 EPIV-80-1140-60 50Hz 60Hz SR24 - PI - 80 Note: he Electronic Pressure Independent Valve (EPIV) must be ordered together with the SR..Rotary Actuator. Ordering examples : EPIV-65-800 with SR24-PI-65 Rotary Actuator fitted, order code: EPIV-65-800+ SR24-PI-65 Neither the actuator nor the Flow sensor can be ordered as a standard product. able of contents Product overview / contents 1 echnical data SR-PI.. Rotary Actuator 2 4 subject to technical changes 1

EPIV technical data Applications Large AH system Distribution Applications Electronic Pressure Independent Valve: DN65...80 For modulating, and MP-Bus control of cold and warm water echnical data Medium cold and warm water, with 50% volume of glycol in closed system emperature of medium system without spindle heater: +2 C...120 C system with spindle heater: -10 C...120 C Rated pressure 1600kPa Flow characteristic equal percentage (following VDE 2173) Rangeability 1:40 (2.5% of the V nom) Pipe connector Flange ISO7005-2 Differential pressure Max. 340kPa Closing pressure ps 700 kpa (actuator still capable of closing valve, leakage rate exceeds 0.01% maximum flow) Angle of rotation 90 Installation position vertical to horizontal (referred to as the valve stem) Maintenance maintenance-free Material Valve body forged nickel-plated brass Ball Stainless Steel Characterising disk Stainless Steel Grounded Flow Sensor Accuracy Inlet length Flow unit needs to be grounded +_5% 5xDN Mode of operation he Electronic Pressure Independent Valve is motor-operated by a type of SR.. Rotary Actuator he actuator is controlled by a modulating or MP-Bus system and move the ball of the EPIV, the throttling element, to the opening position dictated by the control signal. Product features Equal-percentage characteristic Equal-percentage characteristic of the flow ensured by the integrated characterising disk, and algorithm inside actuator Constant flow volume V. Constant flow volume V. with various differential pressure up to 340kPa, thanks to the electronic flow sensor. A valve authority of 1 is attained, regardless of differential pressure variations across the valve. Even in the part-load range, the flow rate remains constant, and valve needs to compensate the dp. Manual operation by lever Manual operation by lever after disengaging the gearing latch on the type of SR.. Rotary Actuator subject to technical changes 2

EPIV technical data System Functionality and olerances Flow olerance of the EPIV: From 25% to 100% V nom +/-10% of the actual Flow From 2.5% to 25% V nom +/-10% of the Flow at 25% +/-2.5% of V nom. V nom = he nominal flow of the EPIV-System Remark: his tolerance is determined under the whole range of temperature and glycal mixture without any calibration on the field. Flow % Curve 1:40 Flow Curve Flow Reading by Feedback () he actual flow can be read out from feedback signal pin 5 (), with referring to the flow curve calculation (2 formulae as below): Linear part (from x = 0% to x = 31%): [%] = X[X] n lin n lin = 0.35 Equal percentage part of the curve (from x= 31% to x = 100%): [%] = kv 0 exp(n gl X[%]) kv0 = 0.04 ngl = 3.22 Common feedback signal table (/5) subject to technical changes 0.5-10 VDC Controller Actuator Feedback: /5 2-10 VDC Water Flow in % 0.5-10 VDC Controller Actuator Feedback: /5 2-10 VDC Water Flow in % Controller Actuator Feedback: /5 0.5-10 VDC 2-10 VDC Water Flow in % 0.50 2.00 0% 6.96 7.44 35% 8.96 9.12 70% 1.83 3.12 5% 7.34 7.76 40% 9.24 9.36 75% 3.16 4.24 10% 7.72 8.08 45% 9.43 9.52 80% 4.40 5.28 15% 8.00 8.32 50% 9.53 9.60 85% 5.25 6.00 20% 8.29 8.56 55% 9.72 9.76 90% 5.92 6.56 25% 8.58 8.80 60% 9.91 9.92 95% 6.49 7.04 30% 8.77 8.96 65% 10.00 10.00 100% 3

SR-PI..Rotary Actuators Communication-capable rotary actuator for EPIV system orque 20Nm Nominal voltage AC/DC 24V Communication via BELIMO MP-Bus Conversion of sensor signals Multifunction control SR24-PI-65 SR24-PI-80 echnical data Electrical data Nominal voltage AC 24V, 50/60 Hz / DC 24V Power supply range AC 19.2... 28.8V / DC 21.6... 28.8V Power consumption in operation At rest Rating 8.5W @ nominal torque 5.75W 11VA Connection Cable 1m, 4 x 0.75mm 2 orque (nominal torque) Min. 20Nm at nominal voltage Control Control signal DC 0.5...10V, input impedance 100k Working range DC 0.5...10V Position feedback (measuring voltage 5) Running time Volumetric flow, DC 0.5...10V 90s / 90 Sound power level Max. 45dB (A) (Just Actuator) Position indication Mechanical, plug-on Safety Protection class III Safety extra-low voltage Degree of protection IP54 EMC CE according to 89/336/EEC Mode of operation ype 1 (in acc. with EN 60730-1) Rated impulse voltage 0.8 kv (in acc. with EN 60730-1) Ambient temperature range -30... +50 C Non-operating temperature range -40... +80 C Ambient humidity range <95% RH, non-condensating (acc. to EN 60730-1) Maintenance Maintenance-free Dimensions/weight Dimensions See "Dimensions" on page 7 Weight approx. 1200g Sensor Nominal voltage AC 24V, 50 Hz ( 60Hz: EPIV-...-60) DC 24V 4

SR-PI..Rotary Actuators Safety notes! he actuator has been designed for use in stationary heating, ventilation and air conditioning systems and is not allowed to be used outside the specified field of application, especially in aircraft or in any other airborne means of transport. It may only be installed by suitably trained personnel. All applicable legal or institutional installation regulations must be complied with. he device may only be opened at the manufacturer s site. It does not contain any parts that can be replaced or repaired by the user. he cable is not allowed to be removed from the unit. he device contains electrical and electronic components and is not allowed to be disposed of as household refuse. he local and currently valid regulations and requirements must be observed. Product features Mode of operation Conventional operation: he actuator is controlled with a standard modulating signal of DC 0...10V and travels to the position defined by the control signal. Measuring voltage serves for the electrical display of the flow. Operation on the MP-Bus: he actuator receives its digital positioning signal from the higher level controller via the MP-Bus and travels to the flow defined. Connection serves as communication interface and does not supply an analogue measuring voltage. Converter for sensors Parameterisable actuators Manual override High functional reliability Connection option for a sensor (active sensor or switching contact). he MP actuator serves as an analog/digital converter for the transmission of the sensor signal via MP-Bus to the higher level system. he factory settings cover the most common applications. Input and output signals and other parameters can be altered with the MF-H parameterising device or the BELIMO Service ool, MF-P. Manual adjustment possible with pushbutton - temporary, permanent.he gear is disengaged and the actuator decoupled for as long as the button is pressed / latched. he actuator is overload-proof, requires no limit switches and automatically stops when the end stop is reached. Description of the Parameters used Measurement range Control range Area for V'max Measurement range 0% 2.5% 30% his range describes the range the sensor can measure. V'max V'nom=100% Flow Control range his range describes the range the system can control a certain flow value. he Control range is 1:40 (2.5% of the V'nom) he Control range is not adjustable by any tools. V'nom V'max Is the nominal Flow of the EPIV -System. Each DN - Size has just one V'nom. he maximum Flow value can be adjusted. - V'max can be equal with V'nom - V'max can be lower than V'nom - Adjustment range: 30%--100%V'nom V'max can be adjusted with the PC -ool (Version 3.5) and the GEN.VAV 5

SR-PI..Rotary Actuators Electrical installation Wiring diagram Conventional operation Operation on the MP-Bus Notes Connect via safety isolation transformer.! Parallel connection of other actuators possible. + DC 0.5...10V DC 0.5...10V + DC 0.5...10V MP 1 2 3 5 1 2 3 5 SR24-PI.. SR24-PI.. Connection of active sensors + MP Connection of external switching contact + MP p Further actuators and sensors (max. 8) Further actuators and sensors (max. 8) 1 2 3 5 1 2 3 5 + SR24-PI.. Supply AC/DC 24A Output signal DC 0.5... 10V (max. DC 0... 32V) Resolution 30 mv + SR24-PI.. Switching current 16 ma @ 24V Start point of the operating range must be parameterised on the MP actuator as > _ 0.6V 6

SR-PI..Rotary Actuators Functions for actuators with specific parameters Override control and limiting with AC 24V with relay contacts e (DC 0... 10V) From controller a b c d e.g. 1N 4007 Function a b c d e Close V'max 1 2 3 5 Open 1 Control SR24-PI-.. #1:Valve fully open Dimensions [mm] Dimensional diagrams 34 34 139 96 45 16 62 17 21 47 50 6 64 153 66 95 48 70 176 172 Valve+Actuator Dimensions & Weight B C M-Piping otal D A Valve otal Height A.) Valve B.) Sensor C.) M - Piping D.) Actuator DN [mm] 65 80 Dimensions [mm] Weight M-Piping Seal Valve otal Height [kg] 315 2 136.5 454 290 22.5 329 2 168 499 297 26.6 7

Innovation, Quality and Consultancy: A partnership for motorising HVAC Actuators BELIMO Automation AG Brunnenbachstrasse 1 8340 Hinwil, Switzerland el: +41 43 843 61 11 Fax: +41 43 843 62 68 E-mail: info@belimo.ch BELIMO Actuators (Shanghai) rading Ltd. 479 Chun Dong Road, Building C-2 Xin Zhuang Industry Park Shanghai 201108, P.R. China el: +86 21 5483 2929 Fax: +86 21 5483 2930 E-mail: info.asiapacific@belimo.ch BELIMO Aircontrol (SA), Inc. 43 Old Ridgebury Road Danbury, C 06813-2928, SA el: +800 543-9038 / 203 791-9915 Fax: +800 228-8283 / 203 791-9919