TABLE OF CONTENTS. Hurricane 1300 User Manual 2 Rev. 4



Similar documents
Bubble King. User Manual

1. Before You Begin... 3

Snapshot. LEDrain 38 USER MANUAL. Ok on Dimmer. Outdoor OK. Sound Activated. DMX/Master/Slave. 115V/230V Switch. Replaceable Fuse.

TABLE OF CONTENTS. 6. Technical Specifications Page 2 of 20 COLORband PiX User Manual (Rev. 02)

FT-100 Fire Training Fog Machine User Manual English

TABLE OF CONTENTS. Returns Contact Us... 20

1. BEFORE YOU BEGIN INTRODUCTION SETUP AC POWER... 7 Power Linking... 7 MOUNTING... 8 Orientation... 8 Rigging...

1. BEFORE YOU BEGIN INTRODUCTION SETUP... 6

MultiDim MKII V.2 ORDERCODE 50386

Snapshot. User Manual. Use on Dimmer. Outdoor Use. Sound Activated DMX. Master/Slave Autoswitching Power Supply Replaceable Fuse.

Freedom Par Quad-4 IP User Manual Rev. 1

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

TABLE OF CONTENTS. Product Maintenance Technical Specifications...17 Returns Contact Us... 18

TABLE OF CONTENTS. 1. Before You Begin... 3

Cable Tester Pro ORDERCODE D1909

Edition Notes. Edition Notes. Trademarks. Copyright Notice. Manual Usage. Document Printing. Intended Audience. Disclaimer

MANUAL ENGLISH MHS-30S. Ordercode: D6544. Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

Ref. Nr LCP-288 LED COLOR PANEL 288X LED 5MM MANUAL

VF400. User Instructions

Fixture One Power Cord One User Manual One Omega Bracket One DMX Cable - One

LED Par 56 Short DMX ORDERCODE 42421

Portable Air Conditioner

LED Cube Direct Control 30 ORDERCODE 41131

LED BAR 126 / 252 RGB. Owner s Manual LED BAR RGB

RX-18B ORDERCODE D3314

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

K E E P E TH T I H S I MA M N A U N A U L A FO F R

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

MANUAL ENGLISH UBR-180BT Ordercode: D1258

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

DP-DMX20L 4 CHANNEL DMX DIMMER PACK MODE MENU DISPLAY. OUTPUT: 10A/CH, TOTAL 20A Max. DMX CHANNEL RECEIVE TOTAL DMX CHANNEL DIMMER / SWITCH

Congratulations! Thank you!

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

MANUAL ENGLISH. Ordercode: Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

ORLAND FOLLOW PR-1211

STAGE SETTER-8. User Instructions. Elation Professional

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

USER MANUAL PLEASE KEEP THIS FOR FUTURE USE

19 LED Tube Controller ORDERCODE 41003

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

MA-4150 ORDERCODE D6149 Highlite International B.V.

American DJ. User Instructions. American DJ

Sunstrip Active DMX ORDERCODE 30710

Stage Color LED. Elation Professional 4295 Charter Street Los Angeles, Ca Rev. 06/21/07

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

MANUAL ENGLISH. Ordercode: Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

Shogun Blue Laser Head ORDERCODE 30972

LED Par 64 Short V2 ORDERCODE 42464

TMS TANK MANAGEMENT SYSTEM

ENGLISH PSS-108 MKII / PSS-110 MKII

ATS Overhead Table Shelf System INSTRUCTION MANUAL

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Par 56 90W COB RGB ORDERCODE 43300

GenStore Archive Cabinet

Acrobat. user manual

Ref. Nr WI-PAR 8X 3W LED TRI COLOR BATTERY 2.4GHZ DMX MANUAL

Indoor Remote Controlled Power Points

ComPar KIT 1 & 2 DMX LED light set

K E E P E TH T I H S I MA M N A U N A U L A FO F R

Matrix 5x5 Blinder ORDERCODE 30711

MANUAL ENGLISH Mini-GIG Order code: D2280

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Floodlight Range Installation Guide

LED Par 56 Ultra Bright RGB Black ORDERCODE Polished ORDERCODE 42451

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Warning! To prevent or reduce the risk of electrical shock or fire, do. Caution! There are no user serviceable parts inside this unit.

Meaco 30L and Meaco 40L dehumidifier instruction manual

16/32 Channel 1U Rack Mount CCTV Power Supply

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Manual for Fire Suppression & Methane Detection System

LED Par 64 Short Q4-18 ORDERCODE 42468

HP ProDisplay P17A LED Backlit Monitor. User Guide

Moving Head - One Signal Cable - One Omega Clamp One Power Cable - One Safety

PORTABLE AIR CONDITIONER

1. Dispacking. 2. Safety Instructions

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.


Nest Learning Thermostat Installation Guide. Installation step-by-step

OPTI TRI PAR. User Instructions. Elation Professional 6122 S. Eastern Ave. Los Angeles CA

Single Day Alarm Clock with. Bluetooth and USB Play-through

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

FlexFlash Instruction Manual Models SB FLXFLSH400W, SB FLXFLSH200W, SB FLXFLSHE400W, SB FLXFLSHE200W

IS200-MH. User Manual. 10. Specifications. Input Voltage: AC90-260V 50/60Hz. LED Quantities: 1*150W High brightness white LED unit

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

EC4.8. BalancedReferencePreamplifier. Owner smanual ENG

Transcription:

User Manual

TABLE OF CONTENTS 1. BEFORE YOU BEGIN... 3 What Is Included... 3 Unpacking Instructions... 3 Claims... 3 Product at a Glance... 3 Safety Instructions... 4 2. INTRODUCTION... 5 Product Overview... 5 Product Dimensions... 6 3. SETUP... 7 AC Power... 7 Fuse Replacement... 7 Mounting... 8 Orientation... 8 Rigging... 8 4. OPERATING INSTRUCTIONS... 9 Manual Remote Operation (FC-M) (Optional)... 9 Timer Remote Operation (FC-T) (Standard)... 9 Wireless Controller (FC-W) (Optional)... 10 General Troubleshooting... 11 Contact Information... 11 5. TECHNICAL INFORMATION... 12 General Maintenance... 12 Storage... 12 Returns Procedure... 13 TECHNICAL SPECIFICATIONS... 14 Hurricane 1300 User Manual 2 Rev. 4

1. BEFORE YOU BEGIN What Is Included 1 x Hurricane 1300 1 x FC-T wired timer remote 1 x Warranty Card 1 x User Manual Unpacking Instructions Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing. Claims The carrier is responsible for any damage incurred during shipping to this product or any part that shipped with it. Therefore, if the received merchandise appears to have damages caused during shipping, the customer must submit the damage report and any related claims with the carrier, not CHAUVET. The customer must submit the report upon reception of the damaged merchandise. Failure to do so in a timely manner may invalidate the customer s claim with the carrier. For other issues such as missing components or parts, damage not related to shipping, or concealed damage, the customer must make claims to CHAUVET within seven (7) days of receiving the merchandise. Product at a Glance Use on Dimmer Auto Programs Outdoor Use Auto-ranging Power Supply Sound Activated Replaceable Fuse DMX User Serviceable Master/Slave Duty Cycle Hurricane 1300 User Manual 3 Rev. 4

Safety Instructions Please read the following notes carefully because they include important safety information about the installation, usage, and maintenance of this product. Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet. Always make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not higher than that stated on the decal or rear panel of the fixture. This product is intended for indoor use only! (If applicable) To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no flammable materials close to the unit while operating. The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent surfaces. Be sure that no ventilation slots are blocked. Always disconnect from power source before servicing or replacing lamp or fuse and be sure to replace with same lamp source. Secure fixture to fastening device using a safety chain. Never carry the fixture solely by its head. Use its carrying handles. Maximum ambient temperature (Ta) is 104 F (40 C). Do not operate fixture at temperatures higher than this. In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts. Never connect the device to a dimmer pack. Make sure the power cord is never crimped or damaged. Never disconnect the power cord by pulling or tugging on the cord. Avoid direct eye exposure to the light source while it is on. There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact CHAUVET at: 954-929-1115. FCQ (Fog Cleaner Quart) was specifically developed by Chauvet to clean your Hurricane 1300. Make sure you use FCQ regularly to increase the life of your fogger. Hurricane 1300 User Manual 4 Rev. 4

2. INTRODUCTION Product Overview Fluid container Hanging bracket Safety eyebolt Handle Tilt Adjustment knob Heater Nozzle Power switch Low Fluid indicator Manual controller Fluid level indicator Fuse holder Power input (hardwired) Manual Fog button Wireless Controller Hurricane 1300 User Manual 5 Rev. 4

Product Dimensions 317 mm / 12.5 in 425 mm / 16.7 in 306 mm / 12 in Hurricane 1300 User Manual 6 Rev. 4

3. SETUP AC Power To determine the power requirements for a particular fixture, see the label affixed to the back plate of the fixture or refer to the fixture s specifications chart. A fixture s listed current rating is its average current draw under normal conditions. All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch. Before applying power to a fixture, check that the source voltage matches the fixture s requirement. Check the fixture or device carefully to make sure that if a voltage selection switch exists that it is set to the correct line voltage you will use. Fuse Replacement Unplug the IEC power cable before replacing the fuse! Always replace with same type of fuse. This product has a replaceable fuse. In the event that the fuse needs to be replaced, follow the instructions provided below. 1. Using a flat head screwdriver, remove the fuseholder from the IEC housing. 2. Remove the bad fuse from the fuseholder. 3. Insert the new fuse into the fuseholder. 4. Install the fuseholder in the IEC housing. The fuse is located inside this compartment. Remove using a flat head screwdriver. Hurricane 1300 User Manual 7 Rev. 4

Mounting Orientation Rigging This fixture should only be mounted/used on a flat surface. This fixture may not be tilted. It is important never to obstruct the vents pathways. Mount the fixture using, a suitable C or O type clamp. When selecting installation location, take into consideration the fluid reservoir access and routine maintenance. Safety cables must always be used, utilizing the provided safety eye bolt. Never mount in places where the fixture will be exposed to rain, high humidity, extreme temperature changes or restricted ventilation. Hanging Clamp Angled Down Angled Up Note! Clamp is sold separately. Hurricane 1300 User Manual 8 Rev. 4

4. OPERATING INSTRUCTIONS Manual Remote Operation (FC-M) (Optional) 1. Plug in the fog machine to power and turn the power switch to the fixture on. 2. Plug in the wired manual remote to the Manual Controller socket on the rear of the fog machine. 3. Press the single button located on the remote to trigger the fog output. The button is momentary, which means that the fog machine will only output while the button is pressed. Once the button is released, the fog will stop outputting. Timer Remote Operation (FC-T) (Standard) This mode will allow you to control the fogger manually, set the fog machine to run continuously, or to set the fog machine to run off bursts with adjustable interval and duration settings. 1. Plug in the fog machine to power and turn the power switch to the fixture on. 2. Plug in the timer remote to the Manual Controller socket on the rear of the fog machine. 3. Press the TIMER ON/OFF button on the timer remote. The LED above the button should light, indicating activation of function. 4. You may now set the INTERVAL & DURATION adjustment knobs to the desired position. The INTERVAL is the time between bursts of fog. The DURATION is the time the fog machine will run during the burst. Interval Adjustment Timer LED Indicator Manual/Power LED Timer Latching Button Duration Adjustment Manual Momentary LED Manual control Momentary Continuous Latching Button Hurricane 1300 User Manual 9 Rev. 4

Wireless Controller (FC-W) (Optional) This mode will allow you to control the fogger using the optional wireless controller. This consists of the transmitter and the receiver. You may control up to 4 independent fog machines or many more if you run them simultaneously. See the below instructions on setting up your fogger to operate with the FC-W. 1. Plug the wires receiver into the fog machine 5-pin port labeled Wireless Controller. 2. There are 4 buttons on the wireless remote transmitter which act as triggers. Each button can be assigned to a different fog machine. You may only choose 1 dipswitch on each receiver. See the below configuration for setting the receivers to operate with the transmitter remote. Mode CH1 CH2 CH3 CH4 Dipswitches 1 = On, 2-4 = Off 2 = On, 1,3,4 = Off 3 = On, 1,2,4 = Off 4 = On, 1,2,3 = Off 3. Press the fog button, and the fog machine will output fog momentarily for as long as you hold down the button. LED indicator (ready) LED indicator (heating) Dipswitches Wireless Transmitter Fog Triggers Wireless Receiver Hurricane 1300 User Manual 10 Rev. 4

General Troubleshooting No Power Symptom No fog output Breaker/Fuse keeps blowing Low fog output Fog machine is not heating up Remote does not work Fluid indicator states no fog, but the container if full. Check mains power. Check external fuse. Check internal fuse. Solution(s) Check fluid level. Check remote. If using wireless, check batteries. If using wireless, check dipswitches on receiver. Possible electrical short. Contact Chauvet or a Chauvet Dealer/distributor for further instruction. Run a cleaning solution through the fog machine. Check that the fog machine is plugged into the correct voltage. Check to replace the external fuse. Check to replace the internal fuse. Possible bad part. Contact Chauvet or a Chauvet Dealer/distributor for further instruction. Make sure connector is firmly connected to device. Try using another controller. Possible bad controller. Check the internal fuse. Check the external fuse. Try resetting the fog machine by turning the power off, and then on again. Possible bad part. Contact Chauvet or a Chauvet Dealer/distributor for further instruction. If you still have a problem after trying the above solutions, please contact CHAUVET Technical Support at the location listed below. Contact Information World Headquarters CHAUVET General Information Address: 5200 NW 108th Avenue Sunrise, FL 33351 Voice: (954) 929-1115 Fax: (954) 929-5560 Toll free: (800) 762-1084 Technical Support Voice: (954) 929-1115 (Press 4) Fax: (954) 756-8015 World Wide Web www.chauvetlighting.com United Kingdom & Ireland CHAUVET Europe Ltd. General Information Address: Unit 1C Brookhill Road Pinxton, Nottingham, UK NG16 6NT Voice: +44 (0)1773 511115 Fax: +44 (0)1773 511110 Email: uktech@chauvetlighting.com World Wide Web www.chauvetlighting.co.uk Hurricane 1300 User Manual 11 Rev. 4

5. TECHNICAL INFORMATION General Maintenance Do not allow the haze machine to become contaminated. After every 40 hours of continuous operation, use Chauvet Fog Cleaner Quart (or a solution of 80% distilled water and 20% distilled vinegar) through the system to prevent the accumulation of particulate matter in the heating element is recommended. The recommended cleaning regimen is as follows: 1. Empty all haze liquid from the machine. 2. Add cleaning solution to tank. 3. Plug unit in and allow it to warm up. 4. Run the unit in a well-ventilated area until the tank is almost empty. Do not allow the pump to run dry. 5. Cleaning is now complete. Refill with haze liquid. Run the machine briefly to clear any cleaning solution from the pump and heater. Fog Cleaner Quart (FCQ) was specifically developed by Chauvet to clean your Hurricane 1300. Make sure you use FCQ regularly to increase the life of your product. Storage Before storing this product, FCQ through the system as described in the cleaning method above. This will help to avoid any particles condensing inside the pump or heater. Test-run your Hurricane 1300 on a monthly basis to achieve the best performance. Hurricane 1300 User Manual 12 Rev. 4

Returns Procedure Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Merchandise Authorization Number (RMA #). Products returned without a RMA # will be refused. Call CHAUVET and request a RMA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the customer s responsibility. CHAUVET reserves the right to use its own discretion to repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. If you are given a RMA #, please include the following information on a piece of paper inside the box: 1. Your name 2. Your address 3. Your phone number 4. The RMA # 5. A brief description of the symptoms Hurricane 1300 User Manual 13 Rev. 4

TECHNICAL SPECIFICATIONS WEIGHT & DIMENSIONS Length...16.7 in (425 mm) Width...12.5 in (317 mm) Height...12.0 in (306 mm) Weight... 21 lbs (9.5 kg) POWER AC Power... 120V 60Hz AC or 230V 50Hz Fuse... 13A 250V Power Consumption... 1,328W (11.2A) max at 120V Inrush Power... (11.2A) at 120V Power Factor... 0.99 at 120V Fuse... 7A 250V Power Consumption... 1,325W (5.8A) max at 230V Inrush Power... (1.83A) at 230V Power Factor... 0.99 at 230V THERMAL Maximum ambient temperature... 104 F (40 C) CONTROL & PROGRAMMING Data input... 5-pin & ground DIN5 female socket Data pin configurationpin1(led), pin2(control), pin3(+5v), pin4(ground), pin5(none), ground(none) ORDERING INFORMATION Hurricane 1300... F1300 Wired manual remote (optional)... FC-M Wired timer remote (included)...fc-t Wireless manual remote (optional)... FC-W SPARE PARTS ORDERING INFORMATION Master PCB... P170-F3MSPCB Heater... 1P20-HT13 Pump... P200-F3PUMP Fluid container... P170-F3FLC Fluid sensor... P170-F1FLOS Thermal switch... P170-THEF11 Bracket knob... P111-F3BKNOB Fuse holder... P170-FUSEHOL Manual fog button...p111-f3fogb WARRANTY INFORMATION Warranty... 1-year limited warranty Hurricane 1300 User Manual 14 Rev. 4