Current Balance. Important Information

Similar documents
Physics 41, Winter 1998 Lab 1 - The Current Balance. Theory

Pre-lab Quiz/PHYS 224 Magnetic Force and Current Balance. Your name Lab section

Experiment #9, Magnetic Forces Using the Current Balance

Physics 221 Experiment 5: Magnetic Fields

FORCE ON A CURRENT IN A MAGNETIC FIELD

Magnetic Field of a Circular Coil Lab 12

ELECTRIC FIELD LINES AND EQUIPOTENTIAL SURFACES

The purposes of this experiment are to test Faraday's Law qualitatively and to test Lenz's Law.

Electric Field Mapping Lab 3. Precautions

Experiment 6: Magnetic Force on a Current Carrying Wire

E/M Experiment: Electrons in a Magnetic Field.

Lab 8: Ballistic Pendulum

Prelab Exercises: Hooke's Law and the Behavior of Springs

Experiment 3: Magnetic Fields of a Bar Magnet and Helmholtz Coil

The DC Motor. Physics 1051 Laboratory #5 The DC Motor

Resistance, Ohm s Law, and the Temperature of a Light Bulb Filament

Experiment 3: Magnetic Fields of a Bar Magnet and Helmholtz Coil

Interferometers. OBJECTIVES To examine the operation of several kinds of interferometers. d sin = n (1)

Interference. Physics 102 Workshop #3. General Instructions

Force on Moving Charges in a Magnetic Field

Magnetism. d. gives the direction of the force on a charge moving in a magnetic field. b. results in negative charges moving. clockwise.

Experiment #8: Magnetic Forces

1. The diagram below represents magnetic lines of force within a region of space.

Ampere's Law. Introduction. times the current enclosed in that loop: Ampere's Law states that the line integral of B and dl over a closed path is 0

Polarization of Light

Lab 7: Rotational Motion

Experiment 7: Forces and Torques on Magnetic Dipoles

5. Measurement of a magnetic field

Experiment 8: Undriven & Driven RLC Circuits

Magnetic Fields and Their Effects

Measurement of Charge-to-Mass (e/m) Ratio for the Electron

Review Questions PHYS 2426 Exam 2

General Physics Lab: Atwood s Machine

Objectives. Capacitors 262 CHAPTER 5 ENERGY

F B = ilbsin(f), L x B because we take current i to be a positive quantity. The force FB. L and. B as shown in the Figure below.

Motion of Charges in Combined Electric and Magnetic Fields; Measurement of the Ratio of the Electron Charge to the Electron Mass

Physics 25 Exam 3 November 3, 2009

GENERAL SCIENCE LABORATORY 1110L Lab Experiment 6: Ohm s Law

Experiments on the Basics of Electrostatics (Coulomb s law; Capacitor)

A Determination of g, the Acceleration Due to Gravity, from Newton's Laws of Motion

PS-6.2 Explain the factors that determine potential and kinetic energy and the transformation of one to the other.

Rotational Motion: Moment of Inertia

Experiment #4, Ohmic Heat

Experiment #3, Ohm s Law

6/2016 E&M forces-1/8 ELECTRIC AND MAGNETIC FORCES. PURPOSE: To study the deflection of a beam of electrons by electric and magnetic fields.

The Viscosity of Fluids

Experiment 5: Magnetic Fields of a Bar Magnet and of the Earth

Reflection and Refraction

Lab 3 - DC Circuits and Ohm s Law

Mechanics. Determining the gravitational constant with the gravitation torsion balance after Cavendish. LD Physics Leaflets P

Physics 121 Sample Common Exam 3 NOTE: ANSWERS ARE ON PAGE 6. Instructions: 1. In the formula F = qvxb:

Mapping the Magnetic Field

Electromagnetism Laws and Equations

Fraunhofer Diffraction

AP Physics C. Oscillations/SHM Review Packet

ELECTRICITE ET MAGNETISME.

EXPERIMENT 7 OHM S LAW, RESISTORS IN SERIES AND PARALLEL

A METHOD OF CALIBRATING HELMHOLTZ COILS FOR THE MEASUREMENT OF PERMANENT MAGNETS

Edmund Li. Where is defined as the mutual inductance between and and has the SI units of Henries (H).

1. A wire carries 15 A. You form the wire into a single-turn circular loop with magnetic field 80 µ T at the loop center. What is the loop radius?

Simple Harmonic Motion

Determination of Acceleration due to Gravity

Physics 9e/Cutnell. correlated to the. College Board AP Physics 1 Course Objectives

Lab E1: Introduction to Circuits

Sample Questions for the AP Physics 1 Exam

Experiment #5, Series and Parallel Circuits, Kirchhoff s Laws

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

The electrical field produces a force that acts

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

A Comparison of the Measured Magnetic Field Strength Using Ampere-Turns (AT) and millitesla (mt)

Determination of g using a spring

Physics 202 Problems - Week 8 Worked Problems Chapter 25: 7, 23, 36, 62, 72

Copyright 2011 Casa Software Ltd. Centre of Mass

General Physics (PHY 2140)

Eðlisfræði 2, vor 2007

ACCELERATION DUE TO GRAVITY

EXPERIMENT 3 Analysis of a freely falling body Dependence of speed and position on time Objectives

Electrical Resonance

Experiment 2: Conservation of Momentum

MEASURING INSTRUMENTS. By: Nafees Ahmed, Asstt, Prof, EE Deptt, DIT, Dehradun

Acceleration of Gravity Lab Basic Version

Electricity. Confirming Coulomb s law. LD Physics Leaflets P Wie. Electrostatics Coulomb s law

Lab 4: Magnetic Force on Electrons

Fric-3. force F k and the equation (4.2) may be used. The sense of F k is opposite

Cathode Ray Tube. Introduction. Functional principle

FRICTION, WORK, AND THE INCLINED PLANE

Chapter 22: Electric Flux and Gauss s Law

Capacitors in Circuits

AP1 Electricity. 1. A student wearing shoes stands on a tile floor. The students shoes do not fall into the tile floor due to

E X P E R I M E N T 8

LAB 6 - GRAVITATIONAL AND PASSIVE FORCES

Parallel Plate Capacitor

Spring Force Constant Determination as a Learning Tool for Graphing and Modeling

Solving Simultaneous Equations and Matrices

Two bar magnets are brought near each other as shown. The magnets... A) attract B) repel C) exert no net force on each other.

Magnetic Circuits. Outline. Ampere s Law Revisited Review of Last Time: Magnetic Materials Magnetic Circuits Examples

SOLID MECHANICS TUTORIAL MECHANISMS KINEMATICS - VELOCITY AND ACCELERATION DIAGRAMS

MIME 3330 Mechanics Laboratory LAB 5: ROTATING BENDING FATIGUE

The Simple DC Motor: A Teacher s Guide

Lesson 26: Reflection & Mirror Diagrams

Transcription:

1 Current Balance Equipment Current balance apparatus, laser on tripod, paper and tape, Fluke multimeter, leads, 9 V DC from wall strip, 5 Ω 9.2 A rheostat, two 6 inch flat 1 mm thick rulers, weights (50 mg, 100 mg, 200 mg) Comment: Disconnect the circuit by removing the red banana plug from the red receptacle on the wall strip. Reading Your textbook. Review the vector product (also known as the cross product). Reread Electrical Safety at the beginning of this manual. Important Information 1. This experiment uses a laser beam as an optical lever arm. DO NOT LET THE LASER BEAM OR ITS REFLECTION ENTER YOUR EYE. SERIOUS DAMAGE TO YOUR EYE MAY RESULT. 2. A wire pivots on two knife edges. The knife edges rest on flat surfaces. Both the knife edges and flat surfaces are easily damaged. Please handle them with care, using the centering rod, described below, to center the knife edges and to gently lower the knife edges onto the flat surfaces. 3. A current passes through a rheostat (variable resistor). At the higher currents one end of the rheostat gets quite hot. DO NOT TOUCH THIS END OF THE RHEOSTAT. 1 Introduction The French Physicist Andre Marie Ampere noticed that when one wire carrying an electrical current is brought near a second wire also carrying a current the two wires experience forces. The force is proportional to the product of the two currents and depends on the relative orientations of the wires. A moving charge in one wire must exert a force on a moving charge in the other wire. The force between the two wires is the sum of the individual forces between the moving charges. This force has distinctly different characteristics from the wellknown Coulomb force between charged particles. The force between charged particles due to their motion is called the magnetic force. In this experiment you will verify that the force between two wires is proportional to the product of the currents, and estimate the proportionality constant involved. 2 Description of the Experiment The experiment is similar in principle to the Coulomb balance and indeed uses the same platform. See Fig. 1. A single horizontal rod or wire is pivoted so that it can move freely up and down. Below this wire is a long 10 turn rectangular coil whose long sides are horizontal and parallel to the single wire. One long side of the coil is substantially closer to the single wire than the other long side of the coil. The single wire and coil are connected in series and a current passed through them so that this current is in opposite directions for the single wire and nearby long side of the coil, and in the same direction for the single wire and faraway long side of the coil. The net force between wire and coil is a repulsion. With zero

2 current, the vertical position of the single wire is adjusted to a convenient value. A weight is then added to a pan on the single wire and a DC (constant) current established so that the position of the single wire returns to its initial value. This procedure is repeated for a number of weights. This determines the force on the single wire as a function of the current. 3 Theory As in the case of the Coulomb force, it is necessary to assume that the magnetic force between two wires A and B is brought about by each wire producing a vector field at all points of the other wire. This field is called the magnetic field B. The S.I. unit of magnetic field is the tesla (T), a rather large unit. Consider a differential length of wire d l, where this vector coincides with the wire and points in the direction of the current in the wire. Let r be the vector from d l to the field point. The differential magnetic field d B produced at r is given by db = µ 0 Id l ˆr, (1) 4π r 2 where I is the current, ˆr is the unit vector that points from the wire element to the field point and µ 0 is a constant called the vacuum permeability. For almost all purposes, the permeability of air can be taken as µ 0. This constant is defined so that µ 0 /4π is exactly equal to 10 7. In principle, Eq. 1 can be used to calculate the magnetic field produced by one wire at all points in another wire. No matter how complicated the geometry, this magnetic field will be proportional to the current I. If a wire element d l with current I is in the magnetic B it will experience the force df given by d F = Id l B. (2) Eq. 2 can be integrated to give the total force on the wire. Using Eq. 1 and Eq. 2 it can be shown that the magnitude of the force F per unit length between two thin infinitely long parallel wires separated by the distance D is given by F = 2µ 0 I A I B 4π D, (3) where I A is the current in one wire and I B is the current in the other wire. The force is attractive if the currents are in the same direction and repulsive if the currents are oppositely directed. Notice that the force is proportional to the product of the currents. One cannot perform this experiment using infinite wires, but we would expect that the error in using this equation for finite wires, each of length L, would get smaller as the distance D between the wires became smaller and the length of the wires becomes longer. Therefore the following approximate expression is used for the force between two wires of length L. F = 2µ 0 I A I B L 4π D, (4) We will use Eq. 4 as a starting point for analyzing this experiment. First assume that the force on the single wire is due entirely to the the current in the long side of the rectangular coil that is nearest the single wire. The experiment is wired so that the current through the

3 single wire also passes through each turn of the coil. The coil has N=10 turns, so that Eq. 4 can be written F = 2µ 0 NI 2 L 4π D, (5) where I is the common current in the single wire and each wire of the coil. Second, we will break the distance D into two parts such that D = d + b. We define the distance d as the thickness of shim(s) placed between the single wire and the coil. The distance d will be either a or 2a where a=1.0 mm. The distance b is a complicated average that takes into account the thickness of the single wire and the coil. The distance b will be obtained from the data, and (a+b) or (2a+b) will be approximately but not exactly equal to the distance between the center of the single wire and the center of the longer side of the coil nearest the single wire. In other words, the distance b, obtained experimentally, will compensate to some degree for the fact that Eq. 5 assumes two thin wires and in this experiment there are more than two wires and they are not thin. Two sets of data will be obtained, one with D = a + b and denoted by subscript 1, and the other with D = 2a + b and denoted by subscript 2. The following two equations are derived from Eq. 5. F 1 = 2µ 0 NI1L 2 and F 2 = 2µ 0 NI2L 2 4π a + b 4π 2a + b, (6) where I 1 is the current that will result in the Force F 1 on the single wire, and so forth. For each of the two spacings (a+b) and (2a+b) a series of weights are added to the single wire and the current necessary to bring the single wire back to its original position determined. The two sets of data are plotted on the same piece of linear graph paper, force on the vertical axis and current squared on the horizontal axis. The two sets of data have different slopes, S 1 and S 2. Eqs. 6 then give F 1 = S I1 2 1 = 2µ 0 NL and 4π (a + b) These two equations can be solved to give b. F 2 I 2 2 = S 2 = 2µ 0 4π NL (2a + b). (7) b = a(2s 2 S 1 ) S 1 S 2. (8) We can use this value of b in either of Eqs. 6 to obtain a value of µ 0 /4π. Using the first of these equations, we have 4 A Remark About The Speed of Light µ 0 4π = S 1(a + b) 2NL. (9) With the introduction of the vacuum permeability µ 0 it is of interest to note that Maxwell showed in the mid-19th century that by combining his equations containing the electric and magnetic fields he could predict the existence of propagating waves containing both types of fields. He predicted that the speed c of electromagnetic waves is given by c = 1 ɛ0 µ 0 = 3.00 10 8 m/s. (10)

4 The coefficient is not exactly three. If it is written out with more decimal places it is slightly less than three. It was assumed by Maxwell and other scientists of the time that electromagnetic waves propagated in a medium that was called ether. Michelson in his experiment of 1881 could not detect the effect on the speed of light as the earth moved in various directions through the supposed ether. The accuracy was improved in a later experiment by Michelson and Morley but still no effect of motion through the ether could be detected. Einstein s special theory of relativity resolved the dilemma: electromagnetic waves can travel in vacuum and the speed of the waves in vacuum is c even if there is relative motion between the light source and the observer. 5 The Apparatus Fig. 1 is a sketch of the apparatus. The long rectangular coil is fixed in position. The single wire is held by two rods that are attached to a pivot arm that pivots on two knife edges. This allows the single wire to freely move in a vertical plane toward and away from the coil. This single wire assembly has a balance adjustment weight that allows the equilibrium vertical position of the single wire to be adjusted. There is a mirror attached to the pivot arm. A laser beam is directed onto the mirror and then reflected back to a piece of paper taped to the front of the laser. This allows you to return the single wire to a given position with great accuracy. The period adjustment weight changes the oscillation period of the single wire. Moving this weight down makes the period of oscillation longer, and lengthens the times necessary for the wire to stop oscillating. This weight, being below the pivot points, also serves to make the equilibrium position of the wire stable. The lower this weight is, the more stable the mechanical equilibrium of the wire. There is a centering rod (not shown) that is a rod with two knobs at the ends and two off-set points. When the centering rod is rotated, the two points fit into two tapered holes in the bottom of the pivot arm, and one can lift the pivot arm a bit. When the pivot arm is lowered back down, the knife edges should be centered on their supports. This should be done gently so as not to damage the knife edges. You will be provided with 2 small plastic rulers that are quite close to 1.0 mm thick. They are used as spacers to set the distance d between the single wire and coil. A metal plate attached to the pivot arm is positioned in the gap of a small permanent magnet. As the pivot arm swings back and forth, this arrangement provides eddy current damping. 6 Apparatus Set-Up This apparatus is sensitive. Once you start adjusting it and taking data, take care not to disturb the bench or apparatus so as not to move the wire or set it into oscillation. 1. Check that the board on which the apparatus is mounted does not wobble. If it does, adjust one of the two thumbscrews on the front of the board. 2. The current balance is supplied by about 9 V DC from red and black banana plugs on the wall strip. Initially, the red banana plug that goes to the wall strip should be

5 unplugged so that the current in the circuit is zero. Check that the apparatus is wired as shown in Fig. 2, with all elements of the circuit in series. A Fluke multimeter will be used to measure the current. Use the Com and 10 A jacks on the Fluke. To turn the Fluke on, rotate the dial to the A that has a solid and dashed line above it. The A stands for amperes and the solid and dashed lines signify DC (direct or steady current). In so far as feasible, keep the wires and rheostat away from the apparatus so as to minimize the effect of their magnetic fields. 3. Try setting the period adjustment weight toward the lower end of its range. If you decide to move it later, you will have to realign the apparatus as described below. 4. Center the pivot arm by gently raising it and lowering it with the centering rod. 5. Check that the single wire rotates freely. The damping plate should not touch the magnet, and the points on the centering rod should not touch the pivot arm. 6. Hold one of the 6 inch rulers near the middle by the edge. Place the ruler on top of the plastic that holds the coil. The ruler should not rest on the aluminum strip that holds the plastic coil form. Drop a quarter on the weight pan of the single wire to bring the wire down onto the ruler. This procedure sets the distance between the wire and the top of the coil form at d=a=1.0 mm. 7. WITH THE LASER OFF, familiarize yourself with the knobs on the tripod mount so that you can raise, lower, and rotate the laser with ease. In adjusting the laser beam, you may also have to move the tripod sideways. Tape a piece of paper to the front of the laser. 8. REMINDER. DO NOT LET THE LASER BEAM OR ITS REFLECTION ENTER YOUR EYE. Turn on the laser, open the shutter, and adjust the position and orientation of the laser so that the laser beam reflects off the mirror and back onto the paper taped to the laser. Make a horizontal mark where the laser beam strikes the paper. Rather than making the mark in the middle of the laser beam, you might consider making the mark at the very top or bottom of the laser beam. Your ultimate goal will be to return the laser beam to its original location. 9. Remove the quarter and the ruler, taking care not to disturb the position of the wire assembly. Rotate the balance adjustment weight until the laser beam hits the mark you have have already drawn on the paper attached to the laser. The wire should now be in the same position it was in when the ruler was in place. 7 Procedures 7.1 Adjusting the rheostat A rheostat is a variable resistor. The one on the lab bench consists of resistance wire wound on a cylindrical form so that the resistance wire forms a resistive coil which is inserted into the circuit where some resistance is desired. One end of a conducting bar is attached to one end of the coil and the other end of the bar is electrically insulated from the coil. A conducting slider moves along the bar and the coil. The slider makes electrical contact with both the bar and the coil. When the slider is at the end of the coil where the bar is attached to the coil, the resistance presented to the circuit is the full resistance R of the coil.

6 When the slider is at the end of the coil where the bar is electrically insulated from the coil, essentially the coil is shorted out by the bar and zero resistance is presented to the circuit. Intermediate positions of the the slider result in a circuit resistance between 0 and R. If the slider on the rheostat is moved all the way to the wrong end of the rheostat too large a current will flow in the circuit. The Fluke multimeter could be ruined! First, examine the rheostat and see if you can ascertain which end of the rheostat the slider should be at so as to maximize the rheostat s resistance in the circuit and minimize the current in the circuit. Now put the slider in the middle of the rheostat, turn the Fluke multimeter to DC amperes, and plug the red banana plug into the wall strip. The Fluke multimeter should register a current that is less than 9 A, the maximum current rating of the rheostat. Move the slider a little both ways to see which way decreases the current, and then move the slider all the way to the end of the rheostat that minimizes the current. Is this the direction you had determined by examining the rheostat? If not, examine the rheostat again. Unplug the red banana plug from the wall strip so that the current will be zero. 7.2 Taking Data Check that the laser beam is hitting the mark on the piece of paper. Place a 50 mg mass on the pan attached to the wire. Complete the circuit by plugging the red banana plug into the wall strip. Increase the current by slowly moving the rheostat slider until the laser beam hits the mark on the paper. Record the current and the mass. Repeat this procedure for masses from 100 mg to 300 mg in steps of 50 mg. DO NOT EXCEED 9 A, the maximum current rating of the rheostat. Make a four column table of mass in mg, force in newtons, current in A, and the square of the current in A 2. Repeat the above measurements but with a distance between the wire and the top of the plastic coil form of 2 ruler thicknesses (d=2a=2.0 mm). 8 Analysis On the same sheet of linear graph paper, plot your two sets of data, force in newtons on the vertical axis and current squared in A 2 on the horizontal axis. Calculate the slopes S 1 and S 2 of your two lines and use Eq. 8 to calculate b. Then use Eq. 9 with L=0.30 m to obtain a value of µ 0 /4π. Compare your value to 10 7. As an alternative procedure, use your scientific calculator to give a least squares fit to the data, including the origin as one of your points for each line. Your calculator will give you the slope of the line. You might want to do it both ways and compare the results. 9 Questions 1. Can the two sets of data be reasonably represented by straight lines? 2. Draw two straight lines through the data. Each line should go through the origin. Does your data support the statement that for a given spatial configuration, the force is proportional to the square of the current? 3. The two wires that support the single wire also carry current. Will there be a forces on these two wires due to the magnetic field of the coil, and if so, how will they effect the experiment?

7 10 Comments 1. The current produced in one part of a coil will produce a force or stress on another part of the same coil. For example, the two long sides of the coil in this experiment will repel each other. There is no net force on the coil, but there are internal forces. A coil designed to produce a high magnetic has to be designed so that it does not blow apart. 2. The tesla (T) is a very large magnetic field. A commonly used unit of magnetic field is the gauss (G), where 10 4 G = 1 T. The Earth s magnetic field is of the order of 1 G. 11 Finishing Up Please leave the bench as you found it. Thank you. Figure 1: Setup for the experiment.

Figure 2: Schematic of the electric circuit. 8