Series 4G/8G/16G Temperature/Process Controllers

Similar documents
+ A B V B NO NC V COM PV PV

Delta Temperature Controller User Manual

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual

HONEYWELL DC 1010 / / 1040 DIGITAL CONTROLLER PRODUCT MANUAL /02

SYL-2372 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Version 1.4 (May 2016)

INITIAL SETTING MANUAL

2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:

User Manual Auto Tuning PID Temperature Controller

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

PID Microprocessor temperature controllers CTD43 - CTD46 - CTH46

The E5CN provides communications or event input functionality when mounted with one of the following Option Boards.

Softstarters. Type PSTX Fieldbus communication, Built-in Modbus RTU. 1SFC132089M0201 April SFC132089M0201 1

NC-12 Modbus Application

SYL-2342, SYL-2352 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Version 4.6 RTD R 4

#1381-3, Juan-dong, Nam-gu, Incheon, Korea TEL:(82-32) FAX:(82-32)

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

*.ppt 11/2/ :48 PM 1

SR1, SR3 Series Digital Controller Instruction Manual

DC1000 Series General Purpose UNIVERSAL DIGITAL CONTROLLERS

TC-9102 Series Surface Mount Temperature Controllers

ITC-308 Plug and Play Temperature Controller

PX-series digital temperature controller Example of Applications and Parameter Functions

TC 1818a. Operating Guide. Control Module SWM-015.5

T-100-R Installation Guide

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

Thyristor-controlled power supplies and battery chargers

Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line

MODEL 4400 TEMPERATURE CONTROL Royalton Rd. Cleveland, OH (440) (440)

4-Channel Thermometer / Datalogger

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Temperature & Humidity SMS Alert Controller

Operational Overview and Controls Guide

Application/Connection Examples

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

USB-500 Series Stand-Alone, Low-Cost Data Loggers

REGTRONIC OPERATING INSTRUCTIONS

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Dyeing Programmer DP - 01

SMS GSM Alarm Messenger

DC DC DC DC1040

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

DIGITRONIK Digital Indicating Controller SDC10. User s Manual

Telefon (+45) Telefax (+45) Installation and operating manual

PIEZOMETER AIRFLOW MEASURING RING

Operating Instructions. Single Loop Controller EC48 & EC96

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

Manual Ranging MultiMeter

Temperature Controller USER S MANUAL

Programmer/Controller

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Duct Humidity Transmitter

CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

WD-AMX Water Detection Controllers

Online UPS. PowerWalker VFI 1000R/1U

PowerLogic Sub Meter Display (SMD and SMDOPN)

Centro-Matic Automatic Lubrication Systems System Controls

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

Configuring Allen-Brandly ControlLogix PLC with Moxa MGate 5105-MB-EIP. 1 Application Description Objective Goals...

Panel Meters and Controllers Modular Panel Meter Type EDM 35

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

Electronic Control Devices The European Product Catalogue 2007

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

AIS750 Series Alarm Annunciator

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Antec TruePower User's Manual

MEMOBUS/Modbus Communications

NOW A PRODUCT! 1 /4 DIN PROCESS CONTROLLER. Single Loop Profile Controller (optional) NEMA 4X Front Panel PowerTune. The Interface Solution Experts

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

AutoRanging Digital MultiMeter

HCE80/HCC80/HCE80R/HCC80R

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

A project to optimise quality and energy efficiency must include metering

Model: DC-A2IO Advanced HVAC Controller

PRODUCT LIST Facility DDC Access WebXL DDC

Digital Indicating Controllers. Bulletin 05P01A01-01EN.

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

Controls for fan coil units and cassettes

Power Meter Series 700

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL CAUTION CONNECTION DIAGRAM

Softstarters. Type PST/PSTB Fieldbus communication CANopen for PST sw CU SFC132070M0201 February SFC132070M0201 1

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

User s Manual Before using the inverter, you need to read and save the safety instructions.

Controller Automation, Model II+

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Temperature & Humidity SMS Alert Controller

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

User Manual for CH-PFC76810

Transcription:

Series 4G/8G/16G Temperature/Process Controllers Warning DANGER! Caution! Electric Shock! When the power is on, DO NOT touch the AC terminals in case an electric shock may occur. Make sure the power is disconnected when you check the input power supply. Prevent dust or metallic debris from falling into the controller and causeing malfunctions. DO NOT modify or uninstall the controller. Series 4G/8G/16G is an open-type device. Make sure it is installed in an enclosure free of dust and humidity to limit the potential for electric shock. Wait for one minute after the power is switched off to allow the capacitor to discharge. DO NOT touch the internal wiring within this period of time. Display, LED & Keys Ordering Information Series / Panel size (W H) Output 1 options Output 2 options Optional Function 1 Optional Function 2 Options 16: 1/16 DIN W48 H48mm 8: 1/8 DIN W48 H96mm 4: 1/4 DIN W96 H96mm 2: Voltage pulse, 12V ±10% 3: Relay, 250 VAC, 5A 5: DC current, 4 to 20m A 6: L: Linear voltage, 0 to 10 VDC 2: Voltage pulse, 12V ±10% 3: Relay, 250 VAC, 5A 5: DC current, 4 to 20m A 6: L: Linear voltage, 0 to 10 VDC 0: None 1: Event input 2 3: Retransmission output 4: CT input 2 0: None 1: Event input 1 2: Remote setpoint input 4: CT input 1 Blank : AC 100 to 240V LV: DC 24 V±10% 1 Love Controls A Div. of Dwyer Instruments Inc. Michigan City, IN 46360 PH: 800-879-8000 www.dwyer-inst.com

Specifications Supply Voltage AC 100 to 240 V -20/+8%, 50/60Hz; Optional DC 24 V ±10% Power Consumption 5 VA Display Process Value: 4-digit, orange LCD Setpoint Value: 4-digit, green LCD Thermocouple: K, J, T, E, N, R, S, B, L, U, TXK Input sensors RTD: Pt100, JPt100, Cu50, Ni120 Analog input: 0 to 5 V, 0 to 10 V, 0 to 20 ma, 4 to 20 ma, 0 to 50 mv Control modes PID, PID program (ramp/soak), Fuzzy, Manual, /, 2PID Tuning method Auto-tuning, Self-tuning Display Resolution 0 or 1 digit to the right of the decimal point Sampling rate Analog input: 0.1s, Thermocouple or platinum RTD: 0.1s Ambient temperature 0 to +50 C Ambient humidity 35 to 80% RH (non-condensing) Panel Cutout Model Panel cutout ( W H ) 16G 45mm 45mm 8G 44.5mm 91.5mm 4G 91mm 91mm Wiring 4G/8G Wiring Terminals 16G Wiring Terminals 2 Love Controls A Div. of Dwyer Instruments Inc. Michigan City, IN 46360 PH: 800-879-8000 www.dwyer-inst.com

Parameters Operation Regulation Mode Operation Mode Initial Setting Mode Auto-tuning (Set in PID control and RUN Use to set up target temperature Set up input type mode) Self-tuning switch (set when in PID Control loop RUN or STOP Set up temperature unit (not displayed control and the TUNE parameter = ST) when in analog input) Select the n th (n = 0 ~ 5) PID. When n = AUTO, PID is auto-selected. Set up start pattern (when in PID programmable control and ) Set up upper temperature limit Set up PID control offset Set up start step (when in programmable Set up lower temperature limit control) Set up Fuzzy gain value Set up the position of decimal point Select control modes Set up Fuzzy Deadband Lock the keys Select SV control modes Adjust Output 1 hysteresis (when in / control) Adjust Output 2 hysteresis (when in / control) Control cycle for Output 1 (except in / control) Control cycle for Output 2 (except in / control) Ratio of Output 1 against Output 2 when in dual output control (set when in PID and dual output control) Set up deadband (when in dual output) Set up upper limit of Alarm 1 Set up lower limit of Alarm 1 Set up upper limit of Alarm 2 Set up lower limit of Alarm 2 Set up upper limit of Alarm 3 Set up lower limit of Alarm 3 Set up waiting temperature (when in programmable control) Set up waiting time (when in programmable control) Set up start slope (when in programmable control) Select pattern to be edited Select AT or ST Select heating, cooling or dual output heating and cooling Set up input filter factor Record highest temperature of Alarm 1 Set up Alarm 1 mode Set up input filter range Record lowest temperature of Alarm 1 Set up Alarm 1 options Adjust input compensation Record highest temperature of Alarm 2 Set up Alarm 1 delay Adjust input gain Record lowest temperature of Alarm 2 PV color change Set up rising slope (when CRTS = SLOP) Record highest temperature of Alarm 3 2PID Switch temperature Adjust upper limit compensation for Record lowest temperature of Alarm 3 2PID Return temperature analog Output 1* Display and adjust Output 1 volume Set up Remote type analog Output 1* Adjust upper limit compensation for Display and adjust Output 2 volume Select auxiliary function analog Output 2* Set up percentage of upper limit for Output 1 Select auxiliary function 2 analog Output 2* Adjust upper limit compensation for Set up percentage of lower limit for Output 1 Enable/disable communication write-in Retransmission* Set up percentage of upper limit for Output 2 Select ASCII or RTU format Retransmission* Adjust Remote gain Set up percentage of lower limit for Output 2 Set up communication address Adjust Remote compensation Display current measured at CT1 Set up baudrate Set up EVENT1 function Display current measured at CT2 Set up data length Set up EVENT2 function to return to set up target temperature Set up stop bit Set up EVENT3 function to return to auto-tuning *1 scale = 2μA; 1scale = 1mV Set up parity bit to return to set up input type PID mode: Any of the 6 PID groups can be selected. When n = AUTO, the program will automatically select the PID group that is the closest to the target temperature. Select the n th PID (n = 0 ~ 5) 0 ~ 5 th PID Set up the 0 th PID temperature value Set up the 0 th proportional band value Set up the 0 th Ti value Set up the 0 th Td value Set up the 0 th PID integral deviation to return to PID deviation Set up the 5 th PID temperature value Set up the 5 th proportional band value Set up the 5 th Ti value Set up the 5 th Td value Set up the 5 th PID integral deviation to return to PID deviation 3 Love Controls A Div. of Dwyer Instruments Inc. Michigan City, IN 46360 PH: 800-879-8000 www.dwyer-inst.com

Patterns and steps: Edit in parameter. Take editing pattern 0 for example: SPxx & TMxx parameters save must be after in parameter. Select the pattern number to be edited Select number to select Exit pattern and step editing and switch to to continue the setup process. Edit temperature for Step 0 Edit time for Step 0 (time unit: hr, min) Set up Step 0 ~ 15 in order Edit temperature for Step 15 Edit time for Step 15 to set up actual step numbers Select actual number of steps when the program is executing Set up additional cycles (0 ~ 99) for the pattern execution Set up link pattern. refers to the program end. to return to select the pattern number to be edited RS-485 Communication Series 4G/8G/16G Controllers support baudrate 2,400 to 38,400 bps, Modbus ASCII/RTU protocol, function code 03H and reads maximum 8 words from the register. Address Content Definition 1000H Present value (PV) Measuring unit: 0.1 scale. The following values read mean error occurs. 8002H: Temperature not yet acquired 8003H: Not connected to sensor 8004H: Incorrect sensor 1001H Set value (SV) Measuring unit: 0.1 scale. 1002H Upper limit of temp. range Cannot exceed the default value 1003H Lower limit of temp. range Cannot fall below the default value 1005H Control mode 0: PID, 1: /, 2: Manual, 3: FUZZY 1006H Heating/cooling control 0: Heating/ Heating, 1: Cooling/ Heating, 2: Heating/cooling, 3: Cooling/ Cooling 1007H 1 st heating/cooling control cycle 0.1 ~ 99.0 sec. 1008H 2 nd heating/cooling control cycle 0.1 ~ 99.0 sec. 1009H Proportional band (PB) 0.1 ~ 999.9 100AH Ti value 0 ~ 9,999 100BH Td value 0 ~ 9,999 1012H Read/write Output 1 volume Unit: 0.1%, only valid in manual control mode 1013H Read/write Output 2 volume Unit: 0.1%, only valid in manual control mode 1016H Regulated temp. value -99.9 ~ +99.9, Unit: 0.1 102AH Read/write LED status b0: ALM3, b1: ALM2, b2: F, b3: C, b4: ALM1, b5: OUT2, b6: OUT1, b7: AT 102BH Read/write key status b0: Set, b1: Select, b2: Up, b3: Down, 0: it 102CH Panel lockup status 0: Normal, 1: Fully locked, 2: SV adjustable 102DH CT value Unit: 0.1A 103BH AT setting 0:(default), 1: 103CH Control RUN/STOP setting 0 : STOP, 1:RUN (default), 2 : END (program), 3 : HOLD (program) 4 Love Controls A Div. of Dwyer Instruments Inc. Michigan City, IN 46360 PH: 800-879-8000 www.dwyer-inst.com

Alarm Outputs Series 4G/8G/16G controllers offer 3 alarm outputs, and each alarm output has 20 alarm modes to choose from in the initial setting mode. SV Alarm mode Alarm output operation 0 No alarm 1 Alarm output will be enabled when the temperature reaches upper or lower limit: The alarm will be enable when the PV exceeds SV + or falls below SV. SV-() SV SV+() 2 Alarm output will be enabled when the temperature reaches the upper limit: The alarm will be enabled when the PV exceeds SV +. SV SV+() 3 Alarm output will be enabled when the temperature reaches the lower limit: The alarm will be enabled when the PV falls below SV. SV-() SV 4 Alarm output will be enabled when the temperature reaches the absolute value of the upper or lower limit: The alarm will be enabled when the PV exceeds or falls below. 5 Alarm output will be enabled when the temperature reaches the absolute value of the upper limit: The alarm will be enabled when the PV exceeds. 6 Alarm output will be enabled when the temperature reaches the absolute value of the lower limit: The alarm will be enabled when the PV falls below. 7 Upper limit hysteresis alarm: The alarm will be enabled when the PV exceeds SV +. The alarm will be disabled when the PV falls below SV +. SV SV+() SV+() 8 Lower limit hysteresis alarm: The alarm will be enabled when the PV falls below SV. The alarm will be disabled when the PV exceeds SV. 9 Offline alarm: The alarm will be enabled when the input sensor is not correct or offline. 10 Timing alarm SV-() SV-() SV 11 CT1 alarm: The alarm will be enabled when the CT1 value falls below or exceeds. 12 CT2 alarm: The alarm will be enabled when the CT2 value falls below or exceeds. 13 When SOAK status (temperature hold) happens to PID program control, alarm output is. 14 When RAMP UP status happens to PID program control, alarm output is. 15 When RAMP DOWN status happens to PID program control, alarm output is. 16 When RUN status happens to PID program control, alarm output is. 17 When HOLD status happens to PID program control, alarm output is. 18 When STOP status happens to PID program control, alarm output is. 19 When END status happens to PID program control, alarm output is. 5 Love Controls A Div. of Dwyer Instruments Inc. Michigan City, IN 46360 PH: 800-879-8000 www.dwyer-inst.com