TERRACE DNA APPLICATION GUIDE
THE BEST-IN-CLASS FRAME-AND-TILE SOLUTION FOR CUSTOMERS AND DESIGNERS SEEKING THE GREATEST PRICE-TO-PERFORMANCE RATIO AND SPACE DIVISION VERSATILITY. DYNAMIC SPACE PLANNING WITH PROVEN SOLUTIONS: PANEL-BASED TERRACE DNA PANELS 35"H, 50"H, AND 65"H DENSITY REACH STORAGE WALLS 50"H AND 65"H WITH TERRACE DNA EXPANSION/COMPRESSION ADEPT DIVIDERS 50"H WITH TERRACE DNA FREESTANDING CADENCE DESKING NEW FEATURES AND AESTHETIC STYLING: CONSISTENT TILE REVEALS WITH RECESSED SEGMENT BAR PURPOSEFUL ALIGNMENT OF PANELS, OVERHEAD STORAGE, STORAGE TOWERS, TILE SEGMENTATION, REACH, AND ADEPT FULL TILE SEGMENTATION OPTIONS IN 15" INCREMENTS AT ANY LOCATION DESIGNED OPTIONS LIKE RAISED COUNTERTOP ADVANCED VALUE CHOICES: LOWER COST OPTIONS IN WORKSURFACES, DESKING, AND SINGLE-PANE GLASS TILES ABILITY TO GO FROM BASIC TO DRESSED UP SURFACE FINISH CHOICES INCLUDING LANDSCAPE CUSTOM TILE OPTION AND UPGRADED STORAGE OPTIONS CONSISTENT STANDARD LEAD TIMES
TABLE OF CONTENTS OVERVIEW p3-5 FRAMES & CONNECTORS p6-7 TILES p8-9 ELECTRICAL p10-11 WORKSURFACES p12-13 STORAGE p14-15 REACH p16-19 CADENCE p20-21 ACCESSORIES p22 TABLES p22 TYPICALS p23 This application guide is designed to provide an overview and serve as a handy reference when specifying Terrace DNA. For complete model numbers, pricing, and fabric and finish availability refer to the Terrace DNA price list at allsteeloffice.com.
9 STEPS TO SPECIFYING TERRACE DNA 1. FRAMES AND CONNECTORS provide the structure that turns raw space into office space. Stack them up, connect them together, and adorn them with color and texture. See pages 6-7. 2. TILES are for expression. They make simple walls more functional, bringing color, texture, and light to your workspace and your brand. Choose segmented or fill the frame with monolithic tiles. See pages 8-9. 4. WORKSURFACES are the forms that help create function. Use a variety of shapes to define space, encourage teamwork or individual effort, organize tasks, and ensure ergonomic work habits. See pages 12-13. TABLES expand your worksurface. Choose height-adjustable models that easily adjust to the right height. See page 22. 5. STORAGE performs many jobs, from organizing documents to offering a seat. Choices in shapes, sizes, fronts, and pulls mean overhead cabinets, shelves, pedestals, towers, and files can be both functional and stylish. See pages 14-15.
3. ELECTRICAL AND DATA can be routed both vertically and horizontally in the open structure of the frame. In today s high-tech world, every employee needs to plug in. See pages 10-11. ENHANCERS shown below provide products that expand the possibilities of Terrace DNA. 7. REACH where storage is the wall and the wall is storage. Reach creates offices where high-capacity storage is within arm s length and files and piles, peripherals, and electronics are out of the way. See pages 16-19. 8. ADEPT features light-scale dividers and desking that integrate with spine walls of Terrace DNA or Reach storage. Available Spring 2009. 9. CADENCE freestanding desk solution offers unlimited versatility. Made to last with heavy-gauge steel, it works in the open plan, the private office, or in combination with Terrace DNA panels, allowing complete office coordination. See pages 20-21. 6. ACCESSORIES include tools for organization, ergonomics, and lighting that allow you to personalize offices while improving individual productivity and comfort. See page 22. FOR ADDITIONAL TERRACE DNA IDEAS AND THOUGHT STARTERS VISIT OUR TYPICAL GALLERY AT: WWW.ALLSTEELOFFICE.COM/TYPICALS 5
FRAMES & CONNECTORS Radius painted or veneer top trim is standard with any base panel frame. Lay-in top pathway accepts data cables. Stacking frames are available in 15"H or 30"H. Frame features slotted steel vertical members that allow hangon components to be adjusted in 1" increments. 95"H 110"H Beltline area accommodates electrical power and provides desktop access to data and communication cables. Panels (frames and tiles) are a 3" nominal thickness (use 2-3 4" to calculate intersections in length of panel run). 80"H Opening in the side of uprights accommodate data cabling and electrical. Steel horizontal members have vertical cable and electrical routing capacity. Structural panel frames are available in 35"H, 50"H, and 65"H (nominal heights). Plus, 95"H doors and 42"H for transaction tops (monolithic only). 35"H 50"H 65"H 95"H 42"H FRAME DIMENSIONS Widths: 24", 30", 36", 42", 48", and 60" Heights (actual): 34-1/4", 41-3/4", 49-1/4", and 64-1/4" Lay-in base pathway accepts voice, data and fiber optic cable, as well as electrical system. Leveling glides provide 2-3/4" of adjustment and are accessible from the interior of the frame. Base pathway cover has outlet openings that accept duplex receptacles or commercially available modular data faceplates. Depth: 2-5/8" (use 2-3/4" to calculate intersections) Stacking Frames: 15"H and 30"H FRAMES are welded steel verticals and horizontals that turn raw space into office space. They come in basic black; but top trim, base pathway covers, and trim pieces are offered in multiple colors to blend or create contrast. DOOR OPTIONS include a 95"H x 42"W door frame that comes complete with a 36"W x 82-3/4"H laminate or veneer hinged door. The door requires either a door knob or lever to be ordered separately. Hinged door frames include special 7-1/2"H acoustic tiles on each side above the door and will accommodate one 15"H x 42"W stack-on frame to reach a combined height of 110". WALL MOUNT KITS provide a means to affix a panel run to a permanent building wall. Kit adds 1-1 16" to length of panel run. USE END TRIM E at the end of a panel run; or H high-low trim to cover the exposed end of a frame when joining frames of differing height. DIRECT IN-LINE CONNECTIONS between same-height frames in a continuous run are accomplished with provided hardware. There is no incremental increase in dimension along the run. Terrace DNA frames are self-aligning with direct line, panel-to-panel fastening, you get automatic leveling. TOP TRIM is provided with structural panel frames. When adding stacking frames, remove the top trim from the structural frame, and install it on top of the uppermost stacking frame. Stacking connection provides a solid metal-to-metal connection, allowing the stacking frame to accept hang-on components, per Allsteel storage guidelines. SLIDING DOOR options are also available in 50"H, 65"H, or 80"H doors that are 42"W to support a 36"W opening. Doors are Frosted Translucent insert material. Mounting bracket kits are required for sliding door support and attach to an adjacent panel that is 30"W, 36"W, 42"W, or 48"W. Stability guidelines need to be followed when specifying a sliding door. BUILDING HORIZONTALLY WITH TERRACE DNA FRAMES To ensure stability when building horizontally with Terrace frames, use either opposing or single-sided returns. METHOD 1 OPPOSING RETURNS: A parent run must be a minimum of 48" and a maximum of 144" between return panels. The parent run must have a minimum of two return panels running in opposing directions on each end of run. METHOD 2 SINGLE-SIDED RETURNS: A parent run must be a minimum of 48" and a maximum of 144" between return panels. The parent run must have a minimum of two return panels totaling at least 58% of its length, extending in one direction. Return panels must not be any more than 30" shorter in height than parent run. WHEN USING 120 CONNECTIONS, 12" MUST BE ADDED TO LENGTH OF RETURN PANELS AS DETERMINED BY METHODS 1 AND 2. ANY RUN UNDER 100" MUST HAVE A MINIMUM COMBINED LENGTH OF 72" OF RETURN PANELS.
CONNECTORS turn two-dimensional panels into three-dimensional floor plans. You can create Ls, Ts, Xs, Ss, or 120 angles with B or C connectors. L 90 T 3-Way X 4-Way Top View Frame Frame MULTIPLE-HEIGHT CONNECTIONS also utilize standard L, T, X, S, and E connectors, with corresponding height connectors stacked according to the number of intersecting panels from the bottom up. (See examples) Example 1 Connectors required: 1-15"H S 1-35"H T Frame 2-3/4" Frame EXTENDED STRAIGHT connectors S are used to keep continuous runs dimensionally consistent with opposing panel runs which incorporate T or X intersections. Connectors may be specified either full height or segmented, as shown. 50"H Example 4 Connectors required: 50"H 1-15"H H 1-35"H C 35"H Example 5 65"H TK330H 35"H TK335L 35"H Example above represents maximum 30"H variable height connection from 35"H to 65"H panels. OPTIONAL STIFFENER BRACKET can be used to increase the stiffness of the interior on a Terrace DNA panel when acoustical tiles are on both sides. It can also be used to mount a power or pass-thru harness at standing height or behind an overhead cabinet. PRICE SCALABILITY: HEIGHT OF FRAMES TOP TRIM PAINTED OR VENEER QUANTITY OF FRAMES - stacking - shared (back-to-back) - width (one vs. two) - use of permanent walls - storage replaces panels - open design WING PANELS - use of high-low trim - use Adept dividers - use full end panels - use of storage - open design CONNECTORS - one piece vs. segmented - painted vs. veneer - quantity required For complete specification rules, model numbers, dimensions, and pricing refer to the Terrace DNA price list at: www.allsteeloffice.com/pricers 35"H BUILDING A 6' X 6' WORKSTATION FROM A TO Z STEP 1 FRAMES & CONNECTORS S In variable height T connections as shown above you would use the connectors as indicated. Example 2 Connectors required: 1-15"H H 1-7"H L 1-7"H T 50"H 1-35"H X 65"H B 120 3-Way 42"H 35"H C 120 3-Way L, T, X, and S connector kits add 2-3 4" to the total length of the panel run for each intersection, whether located in the middle or at the end of the run. Example 3 Connectors required: 1-15"H B 1-50"H C 50"H 65"H 65"H NOTE: Base connectors must be specified at base regardless of full height or segmented connection. COMPONENT SPECIFICATION ORDER: A. FRAMES C. TRIM 4-65"H x 36"W Frames 1-65"H End Trim 1-65"H x 24"W Frame 1-50"H End Trim 1-50"H x 24"W Frame 1-15"H High/Low End Trim B. CONNECTORS 2-65"H L Connectors 1-50"H L Connector 7
TILES Radius painted or radius Cleargrain veneer top trim. Tiles are available in a range of widths to match frame widths: 20", 24", 30", 36", 42", 48", and 60"W. Tile segmentation is based on 15"H vertical increments. Fabric tackable acoustical tiles are available in hundreds of fabrics and colors. Landscape surface tiles allow you to choose from a range of innovative materials including metals, translucent, and patterned translucent. Marker board tiles are excellent for conference areas and offices where informal meetings are frequently held. All tiles are available in 15" and 30" heights, except tool tiles which are 15"H only. Glass tile kits provide access to natural light, and connect office workers visually. Available in single pane. Monolithic tiles are designed to fill the entire frame with one tile; available in 42"H veneer or fabric, and 50"H or 65"H fabric. Data/electrical port tiles permit receptacles to be readily available at worksurface height. Segment kit is required between tiles and provides a 3/8" reveal. Order separately for each side of frame. Tool tiles support modular accessories that free up worksurface space. 65"H monolithic tile is actually 60"H (5" deducted for base/top trim) and fills entire 65"H frame. Cleargrain veneer tiles provide the warmth of wood. TERRACE TILES come in a variety of styles. Select the aesthetic* and functional combination that meets your specific requirements. Choose between: monolithic or segmented, non-ported or ported (fabric only). TOOL TILE PERFORATED STEEL SINGLE-PANE GLASS MARKER BOARD (painted steel order tray separately) VENEER TILES and trim are offered in seven Cleargrain finishes. Cleargrain veneer features a repeatable straight-grain pattern to maintain a consistent appearance across all products. Veneer is available in 15"H, 30"H, and 42"H tiles. STEEL OTHER LANDSCAPE SURFACES With Terrace DNA you order frames and tiles separately for maximum specification flexibility. For example, use monolithic tiles on one side of the frame and segmented on the other. Tiles are for expression. Tool, tackable, marker board and ported make simple walls more functional. Glass, veneers, fabrics, steel, perforated steel, and Landscape surfaces bring color, texture, and light to your workspace and your brand. LANDSCAPE SURFACE tiles add style to space and are available in 15"H or 30"H, except tool tiles which are 15"H only. Options for Terrace DNA Landscape Surfaces include: - Pearlescent Strata - Foundation - Mulberry Paper - Infinite Spectrum (PANTONE) GLASS tiles offer clear or frosted single-pane glass mounted flush to one side. Painted shroud is available in any Terrace DNA trim color. FABRIC tiles are available in over 185 standard panel fabrics in heights up to 65" monolithic, either ported or non-ported. *Aesthetics of opposing tile surface and/or frame interior should be considered when selecting perforated or light-colored sheer materials. Tool tiles work with modular accessories that provide orderly storage within reach. Units can be arranged and rearranged to respond to changing workflow. Steel and perforated steel are available in eight Core and four Select paint colors. PANTONE A unique partnership with Pantone, Inc. means we can put any of the PANTONE for architecture and interiors color system colors or PANTONE MATCHING SYSTEM colors on Terrace tiles. Aesthetics of opposing tile surface and/or frame interior should be considered when selecting perforated or light colored sheer materials. Terrace DNA accepts almost any 1/4" thick material; insert your own 15"H or 30"H materials into custom tile bracket kits to give your space a personal vibe.
TILE HEIGHTS To calculate the total height of tile(s) required, deduct 5" (height of base/top trim) from the total nominal panel height. Example: 65"H frame takes two 30"H tiles. 65-5 = 2 X 30 PRICE SCALABILITY: QUANTITY OF TILES: - monolithic - segmented - width (one vs. two) - use of permanent walls - single-sided GRADE OF FABRIC TYPICAL TILE HEIGHT CONFIGURATIONS** Middle segment bars are required between any two tiles order separately based on tile configuration on each side of frame. Most CAD specification program s tools will calculate quantity of segment bars required. Tiles can be ordered in the size that matches the frame height plus the stacker height. Example: Order a 65" high monolithic tile if you re using a 35"H frame plus a 30"H stacker. TYPE OF TILE: - fabric - Landscape - veneer - custom TYPE OF GLASS: - clear - frosted PORTED OR NON-PORTED Terrace DNA tiles are universal and can be placed at any 15" increment on the frame. 42"H frames are monolithic only and tiles are not interchangeable with other frames. DOOR PANELS are 42"W and include 36"W door and hinges, plus two 7-1/2"H tiles for above the door on each side of frame. Select laminate or veneer door order knob or lever separately. For complete specification rules, model numbers, dimensions, and pricing refer to the Terrace DNA price list at: www.allsteeloffice.com/pricers BUILDING A 6' X 6' WORKSTATION FROM A TO Z STEP 2 ADDING TILES (reverse angle) * Monolithic tiles are actually 5" shorter to account for top trim and base raceway dimensions. ** Additional tile combinations to those shown above are possible; heights above 65" require stacking frames maximum height is 110". COMPONENT SPECIFICATION ORDER: D. TILES 3-65"H x 36"W Fabric 1-65"H x 24"W Fabric 1-65"H x 36"W Fabric ported 3-30"H x 24"W Fabric 4-30"H x 36"W Fabric 2-15"H x 24"W Fabric 8-15"H x 36"W Fabric 1-15"H x 24"W Glass E. SEGMENT KITS (required between all segmented tiles) 8-36"W Segment Bars 4-24"W Segment Bars 9
ELECTRICAL AND DATA Terrace DNA features capabilities for cable management, including electrical, voice, and data. The 8-wire electrical system rated at 20 amps per circuit, or 15 amps, Canadian can be integrated at base pathway and beltline. The open structure of the frame allows voice and data cables to be routed both vertically and horizontally. Capacity for lay-in cabling is provided underneath panel top trim. Base pathway accommodates power and lay-in capacity for data and communication. Jumper connects base pathway power to beltline. Cable openings in frame uprights permit cables to be run between frames. Electrical power harnesses have capacity for 2 receptacles (1 in a 24"W panel) per panel side when ported. Non-base pathway power harnesses require electrical mounting brackets. Ceiling in-feed connects to building electrical supply. Integrated power pole accommodates power in-feed and communication/data lines. Avoid glass or translucent tiles in upper position of frames with integrated power poles. Ceiling power in-feed must connect into an electrical harness located in an adjacent panel. Beltline area accommodates power and data or communication lines. Electrical power harnesses can be routed below worksurfaces using optional brackets and field porting fabric tiles. Power blocks snap into horizontal frame members in the base pathway and accept duplex receptacles. Electrical power harness accepts up to 2 duplex receptacles per panel side (24"W limited to 1) at base pathway. Electrical pass-thru harnesses have capacity for one duplex receptacle per panel side. Base pathway power in-feed mounts into any receptacle position in the base pathway area and is connected to the building electrical supply. Fiber optic cables can follow 90 turns at the intersection of panel runs. FLEXCONNECT ELECTRICAL lets you choose any of four different systems to address your specific needs, local codes, and electrician recommendations: Four-circuit (3+1) Four-circuit (2+2) Three-circuit (separate neutrals) Eight-circuit back-to-back (base pathway only) For base pathway mounting, power blocks snap directly onto brackets. At beltline, harnesses can be mounted on 42", 50", or 65"H frames using optional mounting brackets. DUPLEX RECEPTACLES (ordered separately) snap into power blocks of harnesses. They are labeled to indicate circuit number: 1, 2, 3, or 4 and are available in multiple colors. POWER HARNESS 3 Male / 1 Female / 4 Receptacles ELECTRICAL POWER HARNESSES distribute power in panels. Power harnesses accept two duplex receptacles per panel side; 24"W limited to one. Specify harness length to match panel width. All power harnesses and pass-thru harnesses will stretch 3-1/2", allowing them to span T, X, and S intersections at the base pathway. T intersections require a minimum of one power harness. X intersections requires a minimum of two power harnesses. Use of a ceiling in-feed or jumper requires one additional harness. PASS-THRU HARNESS 2 Male / 1 Female / 2 Receptacles ELECTRICAL PASS-THRU HARNESSES have capacity to handle one duplex receptacle on each side of the panel. A 60" pass-thru harness can be used for a single duplex receptacle per side at beltline and connect to power harness at base pathway. Commercially available modular data faceplates can be used in vacant receptacle openings. NOTE: POWER HARNESSES AND PASS-THRU HARNESSES CANNOT BE ROUTED 90 AT BELTLINE. USE JUMPER TO CONNECT TO BASE PATHWAY OR TO JUMP DOWN TO BASE PATHWAY AND BACK UP. PASS-THRU CABLE 1 Male / 1 Female / 0 Receptacles ELECTRICAL PASS-THRU CABLES distribute power through any panel where receptacles are not required. ELECTRICAL JUMPERS connect power from base pathway or beltline to a harness located on any vertical member, as needed. Jumper cables (2 Female) plug into power block ends of electrical power harnesses or electrical pass-thru harnesses. POWER IN-FEED cables deliver power from building to system. Select quantity of base or ceiling in-feed cables depending on individual power requirements.
TERRACE DNA CABLE CAPACITY Openings in frame sides permit electrical, data, and communication cables to run between frames. Using tackable acoustic tiles, frame openings accommodate up to 42 cables (.25" diameter at 40% fill ratio) and 64 cables (.25" diameter at 60% fill ratio). While you can achieve a 60% fill ratio; when electrical components are installed in the beltline area, cabling capacity through the beltline area is limited to approximately 45% fill ratio. The base pathway allows voice and data lines to run continuously through and between the panels. Lay-in is provided where systems furniture or cabling will be changed frequently. Terrace DNA base pathway accepts up to 74 voice/data cables with.25" dia. (6.03 sq. in.). When electrical system shares base pathway, the cable capacity in Terrace DNA is 27 cables (2.25 sq. in.). Cable quantities listed are at 60% fill ratio. Terrace DNA top pathway accepts up to 8 voice/data cables and variable height junctions accept up to 3 voice/data cables (.25" dia). HORIZONTAL CAPACITY 13/16" 3-1/8" 3-1/8" 8-1/4" See Side View Detail Above PRICE SCALABILITY: OVERALL SYSTEM - minimum requirement - future demand IN-FEED QUANTITY & TYPE - ceiling - base receptacle position - base underside RECEPTACLES - quantity per station - levels - base, beltline, etc. - location - spine vs. wing - harness vs. pass-thru - pass-thru vs. jumper Cable capacity of the Terrace DNA power pole, in addition to electrical infeed, is 69 cables of.25" diameter (5.7 sq. in.). Cables can also enter/exit panel through underside of base pathway at juncture between frames. BASE PATHWAY 65" 50" 42" TASK LIGHTS & DATA PORTS - quantity per station - length - type VERTICAL CAPACITY Top View Detail 3".830" Terrace DNA panels and electrical components are UL listed, and electrical components are also CSA certified. Please comply with all local and national electrical codes when installing and using the electrical system, specifying the number of receptacles on a given circuit, and connecting to the building power supply. CIRCUIT USAGE STRATEGIES CIRCUITS TO EQUIPMENT Assign specific uses for each of the circuits. For example, in a four-circuit system: Circuit 1 Calculators, fans, etc. Circuit 2 Task lights (could be wired to wall switch) Circuit 3 CRT or flat screen monitors Circuit 4 CPUs CIRCUITS TO WORKSTATIONS Assign specific workstations to each of the three available circuits. Use circuit 4 for power-sensitive electronic equipment. BASE PATHWAY AND PORTED TILE RECEPTACLE LOCATIONS 10-5/8" 10-5/8" 24" 10-5/8" 10-5/8" 30" HARDWIRE (CHICAGO CODE) Wiring harnesses and snap connectors are not allowed in Chicago; base pathways must be comprised of all metallic components. For the base pathway, junction box (model 874500, 872500) clips directly into receptacle locations. Customer must furnish conduit, wiring, standard duplex receptacles with metal covers for the beltline, and designer-type receptacles for the base pathway. Power entry can be routed from the ceiling, via a Terrace power pole, or from the floor into a junction box (model 874500). HARDWIRE (NEW YORK CODE) junction box (model 871400) is used at any duplex receptacle location when local electrical codes require hardwire entry. Power can be routed only in one direction in 24"W, 30"W, and 36"W panels; in 42"W, 48"W, and 60"W panels an electrical passthru cable or harness for that panel width can be used to route power in the opposite direction. Unit must connect to a power or pass-thru harness positioned in the base pathway area of an adjacent panel. Customer to furnish all cabling and wiring from power entry to power source. BUILDING A 6' X 6' WORKSTATION FROM A TO Z STEP 3 ELECTRICAL & DATA 10-5/8" 10-5/8" 36" 10-5/8" 10-5/8" 42" 10-5/8" 10-5/8" 48" 10-5/8" 10-5/8" 60" The placement of pedestals and other storage may make some base pathway duplex locations inaccessible and may affect compatibility with pull-up receptacles. DO NOT run electrical equipment or extension cords through cable openings in the frame sides. Use the beltline or base-mounted electrical system for all electrical supply. COMPONENT SPECIFICATION ORDER: F. IN-FEED 1 - Base electrical in-feed G. HARNESSES 2-36"W power harnesses 1-60"W pass-thru harness H. RECEPTACLES 2 - Circuit 1 receptacles 2 - Circuit 2 receptacles I. DATA 1-3-port data faceplate 11
WORKSURFACES & SUPPORTS Worksurfaces are offered in as many shapes as there are workstyles. Asymmetrical configurations allow people to move easily from tasking to meeting; corners and coves surround you with workspace; curves and countertops encourage teaming. All worksurfaces are made with a particleboard core and finished with high-pressure laminate or veneer surfaces to stand up to long hours of hard work. Wire management grommets, available in plastic or metal, are standard in most worksurfaces. Metal grommets are available in oval or square. GROMMETS LAMINATE OR VENEER Flat Edge Laminate Wave Edge* Laminate T-Mold Edge** Laminate * Wave edge detail limited to front leading edge see pricer for further details. **Limited shapes are available. Self Edge Veneer Primary Bow-Front Reef Wave Cove Corner Peninsula P-Shaped Boomerang Jetty Rectangle Dual-Surface SUPPORTS Corner Dual-Surface 120 Corner 60 Pie D-Shaped Quarter Round Countertops Corner Countertop Oval Square End Panels Support Legs Open End Panel Support Closed End Panel Support In-line Support Leg Column Modesty Panels Gussets Supports include end panels, legs, and columns. Brackets let you use the panel to support one or more ends of the worksurface, and keep other sides open and accessible. Cantilever Brackets Worksurface Bracket Kits Flat Brackets Countertop Kit Corner Desk Leg Bridge and Return Kits Pedestal-to-Panel Attachment Bracket Rear Support Bracket Left and Right Cantilevers End Panel Worksurface Bracket Kit Support Leg WORKSURFACE BRACKET KITS allow one end of a worksurface to be supported by a return panel. The return panel width must be the same as the worksurface depth. These brackets can be inserted into the panel reveals at 1" increments, so worksurfaces can be set at almost any height, even to create standing-height stations or meet ADA requirements. CANTILEVER BRACKETS, which are inserted into panel reveals at 1" increments, allow worksurfaces to be mounted and supported at any height. Cantilever brackets are left- or right-handed for use with 24" or 30" depth worksurfaces. Cantilevers should not be used at the end of worksurfaces where no return panels are positioned. Use a support leg in place of left and right cantilevers on single-sided runs over 7 feet long. END PANELS are used at the end of a worksurface run in place of a return panel or when a return panel extends beyond the depth of the worksurface. End panels are Cadence components and are handed. Open or closed end panel supports can be used in place of end panels for a lighter scale look or when using Adept dividers. SUPPORT LEGS support worksurfaces, in a shared or a non-shared position, at a fixed height. In station footprints 7 feet or less, support legs and cantilevers are usually interchangeable in this shared position. Support legs add additional rigidity to both the worksurface and panel run, an important consideration for longer runs or when using overhead storage. In-line support legs can be used in place of support legs for a lighter scale look or when using Adept dividers. REAR SUPPORT BRACKETS are included with corner and corner cove worksurfaces (bracket is left-handed). Rectangular and wave worksurfaces 66" and wider include a center support bracket.
SURFACE SOLUTIONS Primary Jetty & Cove Reef & Dual Corner PRICE SCALABILITY: VENEER VS. LAMINATE LAMINATE EDGE - t-mold - flat - wave Corner & Wave P-Shaped Peninsula 120 & D-Shaped SHAPE OF WORKSURFACES: - rectangular vs. curvilinear - width (one vs. two) GROMMET TYPE - plastic - metal (square/oval) END SUPPORTS - brackets - end panel - storage Cove & Quarter Round Boomerang & Cove Countertop MIDDLE SUPPORTS - cantilever brackets - support leg - storage HEIGHT ADJUSTABILITY - brackets - fixed height - height adjustable Ped-to-Panel Attachment Bracket Rear Support Bracket Left Cantilever Support Column SOMETHING SPECIAL Allsteel s 9120 Program can be used to order laminate flat edge rectangular worksurfaces in any nonstandard width and depth in 1 8" increments up to a maximum of 120"W x 36"D. For other specials Allsteel has a Tailored Products team to assist in providing answers, timing, and costs for any non-standard products your projects may require. They can be reached at 1-888-ALLSTEEL or email at ASICSSPCL@allsteeloffice.com For complete specification rules, model numbers, dimensions, and pricing refer to the Terrace DNA price list at: www.allsteeloffice.com/pricers BUILDING A 6' X 6' WORKSTATION FROM A TO Z STEP 3 ADDING WORKSURFACES AND SUPPORTS PEDESTAL-TO-PANEL ATTACHMENT BRACKETS are used to tie a support pedestal and worksurface into the panel behind the surface. The brackets provide structural support to the panel run by securing the panel directly to the pedestal and can be used in place of a full end panel or return panel. Persona /Essentials brackets are handed and Align bracket is non-handed. SUPPORT COLUMNS are used with Peninsula, P-shaped, Boomerang, Jetty, D-shaped, Quarter-Round, and Reef worksurfaces. Each column includes a worksurface bracket kit that attaches the back of the worksurface to the panel. Available in square or round profile. COMPONENT SPECIFICATION ORDER: J. WORKSURFACES K. SUPPORTS 2-36"W x 24"D Primary 2 - Right-handed Cantilevers 1-36"W x 24"D Corner 2 - Left-handed Cantilevers 2 - Worksurface Bracket Kits 13
STORAGE Storage performs many jobs, from organizing documents to offering a seat. Choices in shapes, sizes, tops, and doors mean overhead bins, shelves, pedestals, and files can be both functional and stylish. For storage on the move, choose pedestals with wheels. OVERHEADS, SHELVES, AND HUTCHES Sliding Door Flipper Door Flipper Door w/easy Assist Shelf Hutch w/flipper Doors Open Hutch PEDESTALS Support and Freestanding F/F or B/B/F Mobile F/F, B/B/F, or B/F Mobile Tops Cushion, Laminate, or Veneer Suspended B/F B Box Drawer F File Drawer L Lateral Drawer (L or R) Left or Right PERSONAL FILES AND TOWERS Personal Files 28"H (L or R) B/B/F/L or B/B/F/F/F Personal Files 40"H (L or R) B/B/F/F/F/L Personal Towers 40"H (L or R) B/B/F/F or F/F/F Personal Towers 50"H and 65"H (L or R and Door or Side Shelves) B/B/F, F/F LATERAL FILES 2-High 3-High 4-High 5-High Custom Hoteling Overfile COMBINATION FILES, STORAGE CABINETS, AND BOOKCASES 4-High Open 4-High w/doors 5-High Open 5-High w/doors Storage Cabinets Bookcases w/1-5 adj. Shelves OVERHEAD CABINETS AND SHELVES arrive fully assembled for easy installation. They are manufactured with all-steel construction and can be positioned vertically in 1" increments. Cabinets have concealed locks; sliding door models feature a center divider, allowing either half to be locked. Overheads and shelves should be limited to two units per panel. When units are suspended from stacking frames, stacking frames should be added to all the parent run panels, and to each return-panel run matching the parent run configuration. Overhead cabinets can be mounted on a panel equal to or up to 18" narrower than cabinet, or on panels wider than the overhead cabinet when using off-module kit. One side of overhead must be held on module. HUTCHES are easy to assemble and provide 20-1/4" of clearance for computers. Hutches attach with supplied brackets to freestanding worksurface(s) of the same width. Additional shelves and shelf dividers are available. Optional tackboard for back of the unit also supports optional tool rail. Overhead cabinets, shelves, and hutches all accommodate recessed task lights. PEDESTALS are 15"W and come in three nominal depths: 20"D, 23"D, and 29"D. Maximum pedestal depths for Cadence freestanding applications: 20"D peds with 24"D worksurfaces 23"D peds with 30"D worksurfaces. SUPPORT PEDESTALS are 28"H and can support one end of a worksurface, in lieu of other worksurface supports. Pedestal location may result in panel receptacle being inaccessible. MOBILE PEDESTALS are wheeled, giving you the flexibility to add or move filing space where it s needed most. They can be nested under worksurfaces mounted at 29-1 2"H. Mobile pedestals cannot be leveled; take this into consideration when planning offices which may have uneven floors. All mobile pedestals come standard with counterweight to ensure safety. You can choose a variety of pedestal tops, including seat cushions that provide convenient additional seating when used on box/file mobile pedestals. SUSPENDED PEDESTALS mount to the underside of the worksurface using keyhole slots in top of pedestals. Do not mount suspended pedestals on bridges or peninsulas. Always mount suspended pedestals at end of worksurfaces. Specification information continued on page 15.
PULL CHOICES FOR ARCH SQUARE J INTEGRAL BEVELED TERRACE DNA STORAGE ARCH SQUARE "J" INTEGRAL BEVELED 15"H METAL OVERHEADS & HUTCHES Sliding Doors (Overheads only) NO PULLS Flipper Doors A S ALIGN STORAGE Metal Fronts A S I Landscape Surface Fronts A S Veneer Fronts A S J PERSONA STORAGE Metal Fronts A S I ESSENTIALS STORAGE Metal Fronts A I B NOTE: Storage unit heights may vary between families. For best aesthetics review actual panel height to height of storage unit being specified. STORAGE FAMILIES ALIGN storage coordinates with Terrace DNA, letting you extend the interior design statement on panels across storage. Dress up Align storage fronts with Landscape surfaces or veneer. Behind the beauty you ll find our strength in storage. Counterweight kits are ordered separately. PERSONA brings distinction to the most durable filing systems you can find. Lateral files are available in a wide variety of customizable configurations with personalized details on everything from pull styles to drawer configurations and more. Counterweight kits are ordered separately. ESSENTIALS is practical, reliable, and reasonably-priced with a full offering of filing solutions that meets most needs, integrates seamlessly with panel systems, complements a range of interior designs, and is easy on the bottom line. Counterweights are included and factory installed. PRICE SCALABILITY: FAMILY - Align storage - Persona - Essentials FRONT MATERIAL - metal - landscape surfaces - veneer FINISH OPTIONS - core paint - select paint SIZE OF UNIT - pedestal depth: 20", 23", 29" - lateral width: 30", 36", 42" - height of unit CONFIGURATION - drawers - doors - shelves - open - accessories SPECIFICATION INFORMATION (continued from page 14) All file drawers feature steel ballbearing slides and drawers with high sides to accept hanging files. PERSONAL FILES AND TOWERS offer a combination of file drawers, box drawers, wardrobes, and shelves for personalization and flexibility. They are available in left- and righthand configurations. Towers are 24"D x 24"W with a 9"W wardrobe cabinet and offer open side shelf or front storage door. Side access tower models include a worksurface bracket. LATERAL FILES are the storage workhorse and come in 30", 36", and 42" widths and multiple heights. Full-front or inset drawer options available with five pull choices. Lateral files allow filing side-to-side or front-to-back (Essentials models require optional rails for front-toback filing). Specify 30"W or 36"W units for two rows of letter size frontto-back filing per drawer; or specify 42"W units for three rows. Units with two 12"H drawers will fit under standard height worksurfaces; threedrawer units with optional laminate or veneer tops provide excellent standing-height worksurfaces. CUSTOM LATERAL FILES allow a specifier to fill a case with a unique combination of 3", 6", 9", 12", and 15"H drawers or 12" and 15"H roll-out shelves. HOTELING LATERAL FILES have individually keyed locks on each drawer, perfect when several workers need to share storage. COMBINATION FILES, CABINETS, AND BOOKCASES all offer additional shelves as an option to allow user to maximize storage capacity. COMBINATION FILES offer a combination of shelf storage and filing in a single cabinet. You can choose between hinged doors or open shelves. Create a similar solution by stacking overfiles onto lateral files. STORAGE CABINETS are available in four heights. Equipped with locking hinged doors and adjustable shelves to conceal and secure supplies. BOOKCASES provide quick access to information, in depths to match laterals or narrower profiles to stand on their own. SOMETHING SPECIAL For specials, Allsteel has a Tailored Products team to assist in providing answers, timing, and costs for any non-standard products your projects may require. They can be reached at 1-888-ALLSTEEL or email at ASICSSPCL@allsteeloffice.com KEYING OPTIONS RANDOM KEYING The factory will assign key(s) numbered 101E-225E arbitrarily. OMIT LOCK CORE The factory will omit lock cores. Removable lock core kits with specific key number must be ordered to facilitate keying alike in the field. (Not available with Reach.) EASY LOCK PROGRAM The Allsteel Easy Lock Program simplifies the lock-core ordering process when multiple cores are being specified. The Easy Lock cores can be specified in three different ways Random, Specified, or Sequential. The program can be used with Allsteel storage that currently uses LKF23C cores (all storage except Receding Door Overheads). Refer to your Allsteel price list for complete Easy Lock specification information. BUILDING A 6' X 6' WORKSTATION FROM A TO Z STEP 4 ADDING STORAGE For complete specification rules, model numbers, dimensions, and pricing refer to the Terrace DNA price list at: www.allsteeloffice.com/pricers COMPONENT SPECIFICATION ORDER: L. OVERHEADS W/ARCH PULLS M. PEDESTALS W/ARCH PULLS 1-36"W Flipper Door 1-24"D Supporting F/F 1-36"W Open Shelf 1-24"D Mobile B/B/F 2 - Dividers 15
REACH Where storage is the wall and the wall is storage. Reach gives you more ergonomic and organized workstations and lets people function more comfortably and efficiently. REACH BRINGS IT ALL TOGETHER 6' X 6' TRADITIONAL WORKSTATIONS 6' X 6' REACH WORKSTATIONS Imagine having everything at arm s length, with nothing under your desk or over your head to knock into. Your office contains an entire wall of storage, with shelves, drawers, files, and compartments for everything from computer peripherals to active projects. In traditional panel systems (see illustration), storage sits on the floor or hangs off the wall. Reach uses storage to create the wall. A spine or wing wall is built with layers of customized storage components, including files and drawers, shelves and compartments. Storage fronts are available in metal and Landscape surface materials; and require Stride tiles for the back of all 50"H or 65"H Reach storage units. Reach integrates with Terrace DNA or Stride panel systems; or Adept dividers, resulting in a uniquely functional, durable, and spacious office environment. Because you do not need panels to support or conceal storage, panels can be lower, letting in more natural light and air. Or, you can do away with panels altogether, and create a completely open design-driven environment by using Reach with freestanding tables and screens. Reach has exceptional power and data capabilities. With power at base pathway and beltline, and at multiple locations inside storage units, equipment and electronics can be taken off the worksurface. Specify storage with tambour door and create the perfect place to power or recharge technology gadgets behind closed doors and out of eyesight. A variety of unique Reach worksurface shapes surround the end user with expanses of active desking. Without pedestals to take under-desk space and overheads to hang from above, worksurfaces can be set at whatever height is most comfortable and productive. With functional storage so close at hand, worksurfaces can be cleared for work. All worksurfaces are available in Allsteel s standard laminate and veneer finishes which makes integration of Reach with Terrace DNA a snap. BUILDING UP REACH START WITH 35"H BOTTOM LEVEL for 50"H or 65"H applications; choose open shelves, drawers, drawers/door, or integrated wardrobe. 4"H project drawer includes pencil tray and adjustable space dividers. Pull options include arch or square. A hinged door is optional for 42"W units and is standard on 48"W units. Front-toback and side-to-side filing is standard in all file drawers. Open shelf bottom modules are 17" deep. Base pathway on the front and back side accepts voice, data, and fiber optic cables as well as the electrical system. Base pathway below drawers is non-ported. Leveling glides provide 2-5/8" of adjustment. ADD 15"H OR 30"H TOP LEVEL unit with shelves. Leave them open or specify tambour door, flipper door, or hinged Landscape surface doors. 30"H tambour door opening is 25-3/8" which will accommodate 2 levels of binders; the 15"H Tambour top level opening is more limiting at 10-3/8"H. PORTED TOP MODULES may be ordered to provide power and data in the back of the module. Nonported top modules can be reversed (rotated 180 ) from bottom unit when produced, allowing it to open toward the facing station. Scoops for routing of cables are standard on all top modules. 30"H TOP LEVEL tambour or open module units ship with one 12" deep, height-adjustable shelf. Additional shelves can be ordered separately. Optional side shelves that mount in 1" increments to the slotted side-wall can be ordered to provide additional organization. REACH FOR TERRACE DNA TOTAL HEIGHT 50"H OR 65"H; ALL UNITS ARE 20"D TOP LEVEL (Integrated wardrobe top level width is 12" narrower than bottom to accommodate wardrobe.) 15"H PORTED OR NON-PORTED TAMBOUR OPEN TAMBOUR OPEN BOTTOM LEVEL (Order metal or Landscape surface doors separately for 24"W split wardrobe.) 35"H 30"H PORTED OR NON-PORTED 50"H Add 15"H Tambour or Open REACH UNITS come fully assembled for easy installation. All-metal construction ensures lasting durability. 50"H and 65"H Reach cabinets require Stride tiles which are ordered separately. One Reach segment kit (ordered separately) is required between each segmented tile on a Reach storage unit. FLIPPER/OPEN LANDSCAPE/OPEN 65"H 50" OR 65"H Add 30"H 9"D Each Side Tambour or Open Optional accessories further enhance the functionality of Reach. DRAWERS 36"W, 42"W OPEN SHELF 36"W, 42"W, 48"W DRAWERS/DOOR 42"W, 48"W (L or R) INTEGRATED WARDROBE 42"W, 48"W (L or R) INTEGRATED WARDROBE 42"W, 48"W (L or R) SPLIT WARDROBE 24"W
LOCKING FOR REACH UNITS is standard on all drawers, non-ported top module tambour doors, top module flipper doors, and integrated wardrobe doors. Bottom level doors, 24"W wardrobe doors, and Landscape surface doors for top module are non-locking. All locks within a single unit are keyed alike, and are core removable. Reach core removable locks are interchangeable with other Allsteel storage products and can be keyed alike with traditional storage. THE WALL With Reach, the office begins with a pair of opposite-facing storage units. REACH Middle or M frames are used between different height Reach units, or to attach wing panels. They are required when using side power and data ports in place of standard side scoops. 20"W End or E frames are attached to the end of a Reach storage unit to connect wing panels and route power and data. Make a smooth transition to lower wing panel heights with standard Terrace DNA high-low end trim kit. E frames use 20"W monolithic or segmented tiles to align with Terrace DNA wing panels. Metal finished ends which add 7/8" to the panel run can be used in places without an E panel or with an In-Line connector. Reach storage units can be ganged directly up against one another in places without wing panels and where power is not routed to the side scoops. In-line connectors allow standard Terrace DNA frames, connectors, and tiles to run in-line with the storage wall and can be used to surround columns or expand the workstation. The backside of Reach units require standard 36"W, 42"W, and 48"W Stride tiles (requires special tool tiles). Data and power can be extended to the base pathway of Terrace DNA wing panels. Worksurfaces can be adjusted to any height; there s no need to adjust clearance for pedestals or overhead cabinets. Ported tiles make data/electrical cables that are routed from the base pathway available at the worksurface. Every Reach storage unit has two faces. The front is where you'll find the storage for one office; the backside provides a canvas of color, texture, tackable, marker board, or shared split-depth storage like a wardrobe closet. Multiple units come together to form a Reach storage wall. Rotate the next unit 180º, and add two more units in-line to create the wall for a four-office cluster. FREESTANDING Reach storage units without panels in an open design environment require at least two 36"-48"W units to be ganged side-by-side. BUILDING OUT REACH Add Terrace DNA frames and tiles, or Adept dividers to define space. Because panels no longer need to support or conceal storage, they can be lower to let in more natural light and open offices up to a more modern way to work. Or, use full-height panels along with the storage wall to create private offices within the open plan. Integrate the storage wall with panel tiles to create a design statement of high contrast, tones and textures, or anything in between. REACH E AND M panel frames are 20"W and are system specific. They connect to Reach storage units and allow integration of Terrace DNA panels. E (End) panel frames ship with top cap, base pathway cover, and attachment hardware. They use 20"W Terrace DNA tiles. M (Mid) panel frames ship with top cap and attachment hardware. E 90 E 3-Way M 4-Way Top View E 90 M 4-Way E 3-Way Each 90, 3-way, or 4-way connection adds 2-3 4" to the total length of the storage run. 90 CONFIGURATIONS consist of an E panel frame, adjacent panel or frame, the appropriate height end trim, and tiles to finish approach side. (Order separately.) 3-WAY CONFIGURATIONS consist of an E panel frame, adjacent panels (both sides), appropriate height end trim, and tiles to finish approach side. (Order separately.) 4-WAY CONFIGURATIONS consist of an M panel frame, adjacent frames, and appropriate height end trim. (Order separately.) IN-LINE CONNECTIONS between Reach E and M panel frames and Terrace DNA frames are accomplished with provided hardware. There is no incremental increase in dimension along the straight-line run. MULTIPLE-HEIGHT CONNECTIONS In variable-height connections (as shown below) you would use the connection parts as indicated. Example 1 50"H TERRACE DNA 1 Reach 65"H M Panel Frame 1 15"H High-low End Trim Example 2 50"H TERRACE DNA 1 Reach 65"H M Panel Frame 1 15"H High-low End Trim 1 22"H High-low End Trim 1 15"H x 20"W Tile Example 3 65"H 65"H 42"H 42"H 65"H TERRACE DNA 1 Reach 65"H E Panel Frame 1 22"H High-low End Trim 1 65"H Panel End Cover 17
REACH ELECTRICAL Reach offers maximum capacity for electrical, voice, and data cable management. The open structure of the frame allows voice and data cables to be routed vertically and horizontally. Standard Terrace DNA 8-wire electrical system can be integrated at two levels in the Reach system except for: Extended power harnesses should be ordered when zig-zagging electrical between the front and back of a Reach unit AND to jump from base to beltline. (See matrix and illustrations below.) Side power/data port can be ordered to replace the scoop in left or right side of top level. When using the side power/data port, an E or M panel frame must be adjacent to the storage unit to provide adequate depth. Top level of integrated wardrobe unit only has one side scoop. Extended power harnesses are used to zig-zag power in the base of a storage unit, jump power up from the base of each individual storage unit to the top level. Cable routing scoops are standard on Reach storage units. Integrated Wardrobe models have one; all other models have two. Optional side power/data ports can replace scoops when adjacent to a 20"W Reach panel. Data faceplates can be mounted in vacant receptacle openings. Base pathway accommodates power and lay-in capacity for data and communication. POWER MAX. # UNIT HARNESS LEVEL LOCATION OUTLETS WIDTH MODEL COMMENTS BOTTOM Zig-Zag 1 Duplex 36" 871160 24" modular dim. 42" 871172 30" modular dim. (see 48" 871172 24" modular dim. illustration 2 Duplex 36" 871236E at right) 42" 871242E 48" 871248E Same Side 1 Duplex 36" 871136 (unit-to-unit) 42" 871142 48" 871148 2 Duplex 36" 871236 42" 871242 48" 871248 TOP Back Panel 1 Duplex Inside or 36" 871136 + 871024 1 Duplex Backside* 42" 871142 + 871024 (facing stations) 48" 871148 + 871024 2 Duplex Inside or 36" 871236E 2 Duplex Backside* or 42" 871242E Except Integrated 1 Inside 1 Outside 48" 871248E Wardrobe or Door units 2 Duplex Inside and 42" 871230E Integrated Wardrobe or Door 0 Duplex Backside** 48" 871236E units top module 12" narrower Side Panel 2 Simplex 36" 879901E Except Integrated 42" or Wardrobe units 48" 879904E Side Panel 2 Simplex 36" (Power and data (Reversed 42" grommet is circuit top) 48" dependent.) Side Panel 1 Simplex 42" 879901E or Integrated Wardrobe (Integrated) 48" 879904E no port on wardrobe side * Backside (facing station) receptacles require Stride ported tiles. Integrated wardrobe port limited to non-wardrobe side of unit. ** Backside receptacles (exterior tiled side of cabinet) would require field cutting of off-module ports in standard tile to align with 12" narrower power harness. Integrated power pole accommodates power in-feed and communication data lines. Duplex receptacles snap into power harnesses or pass-thru harnesses. Use Terrace DNA duplex receptacles. Top level offers optional ports on the back of interior to power components inside non-locking storage modules. Ported tile allows you to use power harnesses to provide power and data for the facing station. Power in-feeds mount into any receptacle position in the base pathway area and are connected to the building s electrical supply. NOTE: UL requires Reach modules with internal ported electrical receptacles to be specified as non-locking units. EXTENDED POWER HARNESSES provide additional length to allow zig-zag between front and back of Reach unit. Additional length of extended power harness can be used to jump from base to beltline (see matrix at left). Top View WING PANELS can be powered from extended harnesses using standard harnesses or pass-thru harnesses. BUILDING TWO 6' X 6' REACH WORKSTATIONS STEP 1 CREATE REACH STORAGE WALL BUILDING TWO 6' X 6' REACH WORKSTATIONS STEP 2 ADDING WING WALLS TO REACH COMPONENT SPECIFICATION ORDER: A. REACH STORAGE W/SQUARE PULLS 2-36"W x 65"H Drawer Bottom with Tambour Door Top B. STORAGE ACCESSORIES 1 - Set of 3 Side Shelves 1-36"W Roll-out Shelf COMPONENT SPECIFICATION ORDER: C. TERRACE DNA FRAMES F. TERRACE DNA TILES 2-20"W x 65"H E End Frames 2-20"W x 30"H Fabric A 4-60"W x 50"H Frames 2-20"W x 30"H Fabric B 2-36"W x 50"H Frames 4-60"W x 15"H Fabric A 4-60"W x 30"H Fabric B D. TERRACE DNA CONNECTORS 4-60"W x 50"H Mono Fabric C 2-50"H L Connectors 2-36"W x 15"H Fabric A 2-36"W x 30"H Fabric B E. TERRACE DNA SEGMENT BARS 2-36"W x 50"H Mono Fabric C 2-20"W Bars 2-36"W Bars G. STRIDE TILES 4-60"W Bars 2-36"W x 30"H Ported Fabric C 2-36"W x 30"H Marker Board
REACH WORKSURFACES Reach offers many unique worksurface shapes that have been designed to make the most of the space you have available. Specify Reach worksurface depth to match Reach cabinet width and it can be configured at standard 29-1 2" height, or at various heights on 1" increments. 66" and 72" wide worksurfaces include a rear center support bracket. 78" and 84" wide worksurfaces require a 24"D cantilever bracket at center (ordered separately). A rear support bracket is also shipped with rudder cove surfaces for use in the corner. All other support hardware must be ordered separately. (Refer to specification information below.) Wire management grommets are standard and are specified in plastic oval, metal oval, or metal square. Worksurfaces can be specified with no grommets. Most Reach laminate worksurfaces can be specified with scalloped rear edge, eliminating the need for grommets. EDGE PROFILES 1-1/4"overall Laminate Flat or Veneer 1-1/4"overall Laminate Wave-Shape Grommet Scalloped Edge PRICE SCALABILITY: SIZE OF REACH UNIT - height: 50", 65" - width: 36", 42", 48" REACH CONFIGURATION - drawers - doors - open - reversed level - shelves - accessories SPACE DIVISION - panels - Adept - screens - modesty panels FRONT MATERIAL - metal - Landscape surfaces SADDLE is a rectangular worksurface with a cockpit cutout, allowing the user to position the computer left, center, or right. 66"W and 72"W saddles come with a center support bracket; 78"W and 84"W saddles require a 24"D cantilever bracket for center support (ordered separately). RUDDER worksurfaces transition from the width of the storage unit at one end (36"D, 42"D, or 48"D); to the width of a return panel or a joining worksurface at the other end. 66"W and 72"W Rudders come with a center support bracket; 78"W and 84"W Rudders require a 24"D cantilever bracket for center support (ordered separately). COMBINATION worksurfaces are a rudder and a corner worksurface in a single surface. 72"W models come with a center support bracket. The 20"D end requires an 18"D handed cantilever (ordered separately). 78"W and 84"W models require a 24"D cantilever bracket for both center and end support (ordered separately). FINISH OPTIONS - core paint - select paint ELECTRICAL & DATA - levels - spine vs. wing walls - harness vs. pass-thru - quantity of in-feeds - quantity of receptacles - data components OFF-MODULE WORKSURFACES Off-module worksurface attachment rails are available which allow standard depth worksurfaces to be utilized with Reach cabinets use is limited to 29-1/2"H. JETTY worksurfaces are designed to work in combination with short rudder worksurfaces to provide a conferencing application. Jetty worksurfaces require the use of a column for support. RUDDER COVE worksurfaces are handed and designed to work in combination with short rudder worksurfaces to provide an L configuration. Worksurface comes with corner support bracket. Each end of the rudder cove worksurface requires the use of the appropriate depth cantilever for support (ordered separately). SECONDARY is a stand-alone handed worksurface that matches the panel width. The depth varies from 24"D or 30"D at one end to 20"D at the other. Worksurface comes with a secondary corner bracket. Additional supports required include a worksurface support bracket and an 18"D cantilever for support (both ordered separately). For complete specification rules, model numbers, dimensions, and pricing refer to the Terrace DNA price list at: www.allsteeloffice.com/pricers BUILDING TWO 6' X 6' REACH WORKSTATIONS STEP 3 ADDING ELECTRICAL AND DATA TO REACH BUILDING TWO 6' X 6' REACH WORKSTATIONS STEP 4 ADDING WORKSURFACES TO REACH COMPONENT SPECIFICATION ORDER: H. ELECTRICAL IN-FEED J. RECEPTACLES 1 - Integrated Power Pole 2 - Circuit 1 receptacles 1-20"W Terrace DNA Power Pole Trim Kit 2 - Circuit 3 receptacles 1-18' Ceiling In-Feed 2 - Circuit 4 receptacles COMPONENT SPECIFICATION ORDER: L. WORKSURFACES M. WORKSURFACE SUPPORTS 2-60"W x 36"D Saddle w/scallops 4 - Worksurface Bracket Kits I. ELECTRICAL HARNESSES K. DATA PORT 4-36"W Extended Harnesses 2 - Simplex/Data (Circuit 4) 4 - Electrical Mounting Brackets 2 - Data Faceplates 2 - USB Jack and Cable 19
CADENCE Cadence freestanding desks can be created by combining Terrace DNA worksurfaces with Cadence supports, modesty panels, and brackets. Cadence provides design flexibility and makes it possible to support virtually any office function, while maintaining Terrace DNA aesthetics. Commonality of components facilitates reconfiguration and simplifies inventory management between systems and freestanding applications. Cadence components that attach to panels are system specific simply select Terrace DNA models. END PANELS AND SUPPORT LEGS Each are available in two options: freestanding or panel-mount. The only difference between the two options is the panel-mount models come with a left- or right-handed bracket to attach the support to a panel in a Cadenceto-systems application. If the freestanding version is purchased and later needs to be converted to panel-mount, the proper handed panel-mount bracket may be purchased separately. DESK-TO-PANEL ATTACHMENT KITS Desk-to-panel attachment kits are used to connect a worksurface and modesty panel perpendicular to a Terrace DNA panel of corresponding width. Opposing end of worksurface must be attached with an end panel, support leg or corner leg mounted directly under this worksurface. When using a corner or corner cove worksurface with the rear corner attached to a panel, and opposing end of worksurface is attached to a freestanding desk use corner w/desk attachment kit. Hand of unit is determined from the user s side of the desk (right-hand unit attaches to right side of modesty). An 11"D end panel is used to freestand peninsulas and curvilinear shapes. BRIDGE KITS Bridge kits include two flat brackets, two modesty panel-to-end panel attachment brackets, and two tie straps. This kit is used when attaching a bridge unit between two rectangular worksurfaces. Desk-to-Panel Attachment Kit (Right-Handed) CORNER WORKSURFACES AND DESK LEGS Corner worksurfaces accommodate 90 corner desk legs. Corner desk legs have strong welded construction that allows gussets and half-height modesty panels to be used with corner legs. CORNER W/DESK PANEL ATTACHMENT KIT Corner w/desk panel attachment kit connects the rear corner of a corner or corner cove worksurface and modesty panel to a Terrace DNA panel when the opposing end of the worksurface shares a support leg with an adjacent freestanding desk and the support leg is mounted under the freestanding desk. Hand of unit is determined from the user s side of the desk (left-hand unit attaches to left side of modesty). Bridge Kit There are some bridge instances where only half of a bridge kit is needed (e.g. using a bridge between a rectangular worksurface and a corner or peninsula). A return kit may be ordered for these instances. RETURN KITS Return kits include one flat bracket, one modesty panel-to-end panel attachment bracket, and one tie strap. These are used when attaching a return to a primary desk. Return kits can also be used in some bridge applications. One example is shown below when using a peninsula. Return Kit Corner w/desk Panel Attachment Kit
STAND-ALONE CORNER MODESTY PANELS Stand-alone corner modesty panels are used only when one or both sides of a corner or corner cove worksurface are freestanding and NOT attached to another worksurface. Specify the width the same as the width of the worksurface. Modesty Panels Stand-alone Corner PEDESTALS PEDESTALS MUST BE ORDERED ONE SIZE SMALLER THAN THE DEPTH OF THE WORKSURFACE. For example, 20"D pedestals should be used with 24"D worksurfaces. 20"D or 23"D pedestals can be used with 30"D worksurfaces. The one exception to the above rule is when a ped-to-ped modesty panel is used between two support pedestals to create a double ped desk. Example: two 29"D pedestals with 30"D bow-front worksurface. PRICE SCALABILITY: SIZE OF WORKSURFACES - depth: 24", 30" - width: 24" - 72" - quantity - shape WORKSURFACE MATERIAL - veneer w/flat edge - laminate w/flat edge - laminate w/wave edge - laminate w/t-mold edge GROMMETS - metal - plastic MODESTY PANELS - full-height - half-height - gussets MODESTY PANELS Following are some general guidelines for Cadence modesty panels: Desk: Modesty panel is the same width as the worksurface except when using a ped-to-ped modesty. Return: Modesty panel width is 6" greater than the width of the worksurface. Bridge connecting two rectangular worksurfaces: Modesty panel width is 12" greater than the width of the bridge worksurface. Bridge connecting a rectangular worksurface and corner or peninsula: Modesty panel width is 6" greater than the width of the worksurface. Corner connecting to an adjacent worksurface: Modesty panel width is the same width as the worksurface. Ped-to-ped: 27"H modesty panel mounts between two support pedestals, eliminating the need for end panels. GUSSETS Gussets can be used in place of a modesty panel with desks 36"W to 60"W. Gussets can also be used with corner desk legs. Ped-to-Ped Modesty STORAGE Using 18"D laterals or personal files provides additional storage options under 24"D worksurfaces. FINISH OPTIONS - core paint - select paint STORAGE TYPE/SIZE - pedestal - lateral - personal file - personal tower - hutch ACCESSORIES - task light - tool rail and work tools - keyboard tray COMPONENTS FOR A 6' X 6' CADENCE WORKSTATION IN-LINE CONNECTIONS OF DESKS Freestanding full end panels must be used to support adjacent rectangular desks, corner desks, and corner desks with returns. Freestanding support legs should NOT be used at the in-line junction. 24"D full end panels may be used at the in-line junction on 30"D rectangular desks if two worksurface tie straps are used to secure the desks together. Four End Panels Four End Panels COMPONENT SPECIFICATION ORDER: A. WORKSURFACES C. STORAGE 2-24"D x 36"W Primary w/o grommets 1-20"D Pedestal - B/B/F 1-24"D x 36"W Corner w/o grommets 1-20"D Pedestal - F/F 1-72"W Stack-On Hutch B. SUPPORTS 2-24"D End Panels D. ACCESSORIES 2-24"D Support Legs 1 - Keyboard Tray 1 - Corner Desk Leg 1-60"W Task Light 4-36"W x 29-1/2"H Modesty Panels 1-72"W x 20"H Tackboard 1-72"W Tool Rail 3 - Work Tools for Tool Rail 21
ACCESSORIES EXTENSIONS ACCESSORIES ARE DESIGNED TO HELP YOU CREATE YOUR OWN SPACE. ORGANIZATION Organization starts with a tool tile or rail, then add paper management and other accessories listed below that let you free up the worksurface for work. Tool tiles are made of durable aluminum extrusion with a powder-coated finish. Match or contrast colors as tastes and style dictate. Tool tiles are 15" high; rails are 5" high and can provide additional flexibility by mounting at 1" increments on panels, hutches, wall track, or over tiles on the back side of Reach cabinets. Mail Box Sidebar Personal Shelf Folder Holder* Paper Wave * Phone Caddy Gripper Clip* Binder Bin* Bookends Tool Box Pencil and CD Holder Multi-Media Hangar* Clip Caddy Freestanding Mail Box TABLES USE FREESTANDING TABLES INSTEAD OF OR WITH INTEGRATED WORKSURFACES. TO GAIN ADDITIONAL FLEXIBILITY ALTITUDE, MERGE, AND GET SET ALL OFFER ADJUSTABLE-HEIGHT MODELS TO LET PEOPLE CHANGE THEIR POSITION WITHOUT CHANGING OFFICES. ALTITUDE Altitude adjustable-height tables provide choices in posture, accommodating individuals of differing body types. The units are easy to operate and improve productivity by encouraging variety in working positions. Base features an electrical drive system that allows worksurfaces to be quickly repositioned with one-touch control. Single-worksurface model travels from 26"H for keyboarding to 40"H for standing working position. Dual-surface worksurface keyboard platform allows an additional 12" of vertical travel for a total range of motion from 20"H to 46"H. Dual-surface keyboard platform articulates from +9 to 15 tilt. Load capacity is 225 lbs. including weight of top. *Consideration needs to be given to height of tools and location of worksurfaces. Tools and contents may extend above or below the tile or rail. ERGONOMIC Ergonomic tools help prevent strain and injuries and allow people to work more comfortably and productively. Keyboard trays are easily adjustable so users can keep their wrists and arms in the correct position for typing and mousing. Trays function with corner worksurfaces with some functional restrictions. ILLUMINATION Recessed task lighting is compact, lightweight, and invisible, making it effective in many different work situations, including small areas. They can be installed under overhead cabinets, shelves, or hutches. Units are black and come in four widths from 24" to 60" wide. Shorter width models can be used on wider overheads, shelves, and hutches. Recessed lights come standard with an electronic ballast, making them 60% more efficient than a standard light and provide longer bulb life and a cooler operating temperature. Optional fused plug models satisfy Chicago electrical codes. MERGE MERGE ADAPTIVE TABLES convert any space (private office, workstation, etc.) into a meeting space. Adaptive tables lift, lower, and dock to provide optimal versatility. Merge adaptive tables are available with round or square tabletops. MERGE HEIGHT-ADJUSTABLE TABLES feature a gas cylinder, similar to the adaptive tables, to provide smooth, quiet height adjustment. Merge heightadjustable tables are available with round, conference end, conference corner, and square tops. Tables adjust from 27"H to 34"H. MERGE STANDARD TABLES offer a wide selection of tabletops and bases in a variety of materials and finishes for use in multiple applications. Standard tabletops and bases are specified separately. BOOM LIGHTS have an adjustable arm that lets employees put illumination on tasks where it s most needed. Boom lights are especially useful in compact areas, for close-up work, and to keep light on the desk instead of creating glare on computer screens. Available in black, as panel-hung or freestanding. DOWN LIGHTS can be mounted on- or off-module, letting you bring brightness to any part of the workstation. Since no overhead cabinets or shelves are required, you can create different effects by mounting the fixture close to the worksurface for concentrated light or higher up for an ambient glow. Down lights come in sizes from 24" to 60" wide, in styles that satisfy both standard and Chicago electrical codes. UP LIGHTS offer soft, ambient light in a sleek, lowprofile design that creates a soothing work environment. Up lights and down lights do not require an overhead or shelf for mounting, but can be installed onto any panel of equal or smaller width. They are available in sizes from 24" to 48" wide, and in styles that satisfy both standard and Chicago electrical codes. GET SET Get Set is a highly efficient, go-anywhere table solution. The unique, timeless design supports multiple functions from the training room to the conference room to the private office. Get Set tables are available in nesting, folding, dual-motion (nest or fold), height-adjustable, and standard models. 27"H Get Set task tables can fit inside workstations and nest under panel-mounted worksurfaces.
TYPICALS Below are some typical examples of Terrace DNA, Reach, and Cadence. They represent only a small portion of the hundreds of additional typicals available on the Allsteel Typical Gallery at: WWW.ALLSTEELOFFICE.COM UNDER KNOWLEDGE CENTER TYPICALS GALLERY. They can be filtered by product, application, size, and cost. Each typical features a 2D CAD drawing, a 3D hidden line perspective, and a complete listing of all the components (including electrical requirements). Use them to better understand the layout and specifying of Terrace DNA, Reach, and Cadence. Typicals are coded with abbreviation of product name, month/year created or updated, and typical letter code. Example: TDNA 1.09AA. Downloadable AutoCAD and Giza files are ready for placement or modification and are easily referenced using the typical code. TOUCHDOWN STATION: TDNA 1.09AA RECEPTION STATION: TDNA 1.09AB L STATION: TDNA 1.09AD L STATION: TDNA 1.09AE L STATION: TDNA 1.09AH PRIVATE OFFICE STATION: TDNA 1.09AF SHARED STATION: TDNA 1.09AI IRREGULAR SHAPE STATION: TDNA 1.09AM U STATION: CAD 1.09AP SHARED WARDROBE STATION: REA 1.09AJ 23
TERRACE DNA Terrace DNA takes everything we know about frame-and-tile, adds in a few updates designers and facilities managers have requested, and delivers the best price-to-performance systems furniture for today s office environment. On its own or with other Allsteel products, Terrace offers design and planning versatility. Aesthetic refinements and options create a more modern point of view. Innumerable choices for fabrics, finishes, worksurfaces, storage, and more mean you can build all sorts of offices across any kind of floor plan. Consistent lead times give you the confidence that your order will be where you need it, when you need it. You can count on Terrace. For more information please visit allsteeloffice.com. Our commitment. We ensure that all materials balance performance and environmental responsibility. Relevant, durable, high-quality products, backed by Allsteel s Lifetime Warranty guarantee years of use and re-use. Allsteel Inc. Muscatine, Iowa 52761-5257 allsteeloffice.com Form # A7916 (01/09) Printed in USA 2009 Allsteel Inc. Allsteel, Altitude, Get Set, Merge and Reach are registered trademarks and Adept, Cadence, Cleargrain, Clip Caddy, Essentials, Extensions, Foundation, Infinite Spectrum, Landscape, Lift & Release, Paper Wave, Pearlescent Strata, Persona, Power Bay, Sidebar and Terrace DNA are trademarks. PANTONE and other Pantone Inc. trademarks are the property of Pantone Inc. Allsteel supports green initiatives in the contract furniture industry as a member of the U.S. Green Building Council. Terrace DNA is an SCS Indoor Advantage Gold certified product.