Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports



Similar documents
Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

Installation Guide for. 10/100 to Triple-speed Port Aggregator. Model TPA-CU Doc. PUBTPACUU Rev. 1, 12/08. In-Line

Installation Guide for. 10/100BaseT Port Aggregator Tap with Active Response. Models PA-CU-AR, PAD-CU-AR. Doc. PUBPACUARU Rev.

Installation Guide for Gig Zero Delay Tap and 10/100/1000BaseT Tap

Ixia Net Optics 10G Regen Tap

Ixia Director TM. Powerful, All-in-One Smart Filtering with Ultra-High Port Density. Efficient Monitoring Access DATA SHEET

Installation Guide for GigaBit Fiber Media Converter

How To Use A Network Instrument Ntap

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

User Manual PT-E-HIP

Net Optics Learning Center Presents The Fundamentals of Passive Monitoring Access

Scalable. Reliable. Flexible. High Performance Architecture. Fault Tolerant System Design. Expansion Options for Unique Business Needs

Scalable. Reliable. Flexible. High Performance Architecture. Fault Tolerant System Design. Expansion Options for Unique Business Needs

G-TAP A Series // Data Sheet

PT100 Portable TAP. User Guide. Revision 1.0

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

FriendlyNET FX Slot Modular Switch. User s Manual

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

F2400 FOM II Series Fiber Optic Modem Technical Manual

Single Port T1/E1 Tap

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data

16-Port and 24-Port 10/100 Switches

Net Optics and Cisco NAM

16-Port Gigabit Green Switch (TEG-S16Dg) 24-Port Gigabit Green Switch (TEG-S24Dg)

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

DD670, DD860, and DD890 Hardware Overview

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

16-Port Gigabit Green Switch (TEG-S16Dg) 24-Port Gigabit Green Switch (TEG-S24Dg)

Data Monitoring Switch

SecureSphere Appliances

Full_IG.book Page 1 Monday, January 9, :11 PM. ProSafe 24 Port Gigabit Switch Installation Guide

Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

FriendlyNet PC Card for PowerBook computers

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

User Guide. DVI-D Fiber Optic Cable. DVI + Digital Audio to HDMI Converter. HDMI to DVI + Digital Audio Converter DVI-3510a.

Fail-Safe IPS Integration with Bypass Technology

User Guide. HDMI Active Cable Extender. DVI-7370c

GEU Port Gigabit Switch

MCR1900 Media Converter 19-Slot Chassis

Media Converters & Chassis

Perle Protocol Transparent Media Converter Modules

ALL8808POE. 8 Port Gigabit PoE+ Switch. Manual

Signal Manager Installation and Operation Manual

How To Use The Visifault Visual Fault Locator

Efficient Network Monitoring Access

TrueAlarm Fire Alarm Systems

Network Instruments white paper

Quick Installation Guide. EtherFast 10/100M Switch. Model No.: SP624R.

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

Gigabit Desktop. manual Models & Model shown: INT / UM

Table of Contents. Network Critical NA LLC Tel: Franklin Street, Suite

Network Performance Channel

HARTING mcon 1000 Introduction and features

Gigabit Switching Ethernet Media Converters - Product User Guide

Gigabit Ethernet Copper-to-Fiber Converters

Ixia xstream TM 10. Aggregation, Filtering, and Load Balancing for qgbe/10gbe Networks. Aggregation and Filtering DATA SHEET

QuickSpecs. Models. ProCurve Mini-GBICs Overview. ProCurve Gigabit-LX-LC Mini-GBIC. ProCurve Gigabit-LH-LC Mini-GBIC

HP V1410 Switch Series. Product overview. Key features. Data sheet

How To Install An At-S100 (Geo) On A Network Card (Geoswitch)

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

User Guide. MC100CM MC110CS Fast Ethernet Media Converter. MC111CS MC112CS WDM Fast Ethernet Media Converter

MIGRATING TO A 40 GBPS DATA CENTER

Media Converters & Chassis

FSW-0505TX/0805TX 5/8 Port SOHO 10/100Mbps NWay Switch FSW-0505TX FSW-0805TX. 5/8 Port SOHO 10/100Mbps NWay Switch. User s Manual. (Revision 1.

Sip/Puff Switch User Guide

5-Port Gigabit GREENnet Switch TEG-S5g ŸGuía de instalación rápida (1) ŸTechnical Specifications (3) ŸTroubleshooting (4)

Terayon DOCSIS Modem Installation. Guide

10/100/1000 Base-T to Gigabit Fiber Media Converter

Perle 10/100 Ethernet Media Converters


Product Information D23m Digital I/O System

Fiber Optic Connectivity SECURITY SURVEILLANCE SOLUTIONS. ComNet Managed Ethernet Switches

Guía de instalación rápida. TEG-S16g TEG-S24g 1.01

Cisco 100 Series Unmanaged Switches Cisco Small Business

8-Port PoE Network Switch

EDR-G903 Series. Industrial Gigabit Firewall/VPN secure router. Introduction. Specifications. Industrial Ethernet Solutions

Cisco MFE and MGE SFP Transceivers Cisco Small Business Network Accessories

D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch. Manual

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

tap into your network

Optimux-34, Optimux-25

HP 1405 Small Office Switch Series

16/32 Channel 1U Rack Mount CCTV Power Supply

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

Cisco 100 Series Unmanaged Switches Cisco Small Business

8 Port Gigabit 10M/100M/1000M Fast Ethernet Switch. User Manual

CNC File Transfer Box. Connecting the CNC File Transfer. CNC Transfer Program

How To Get A High Performance Office Network With Cisco 100 Series Switches

2-Pair HDSL1 Adtran Fiber Optic Link System

MICROSENS Media Converter 10/100/1000T to Gigabit Fiber

FILTERING/FORWARDING RATES 100Mbps port - 148,800pps 10Mbps port - 14,880pps. TRANSMISSION MEDIA 10BaseT Cat. 3, 4, 5 UTP/STP 100BaseTX Cat.

Ethernet Link SGI-2424

tap into your network product brochure

Replacing a Copper or Fiber Transceiver on a NetScaler Appliance

Cisco TelePresence VCR MSE 8220

Cisco Unmanaged Rackmount Switches

ProCurve Switch 1400 Series

HP ProCurve High-Speed Transceivers Installation Guide

Transcription:

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports (800-0037) Doc. PUBTPASXSFPU Rev., 07/08

Contents Introduction.... Key Features... Unpacking and Inspection....3 Product Diagram...3 LED Indicators................................................... 3 Application Diagrams: Memory Operation............................. 4 Connecting to the Network...6 Connecting the Monitoring Device....7 Changing the SFP Monitor Port Connector............................. 8 Connecting Power....8 Specifications.................................................... 9 Accessories...9 Limitation on Warranty and Liability...0

PLEASE READ THESE LEGAL NOTICES CAREFULLY. By using a Net Optics Port Aggregator Tap you agree to the terms and conditions of usage set forth by Net Optics, Inc., the Tap manufacturer. No licenses, express or implied, are granted with respect to any of the technology described in this manual. Net Optics retains all intellectual property rights associated with the technology described in this manual. This manual is intended to assist with installing Net Optics products into your network. Trademarks and Copyrights 007 by Net Optics, Inc. Net Optics is a registered trademark of Net Optics, Inc. Additional company and product names may be trademarks or registered trademarks of the individual companies and are respectfully acknowledged. Additional Information Net Optics, Inc. reserves the right to make changes in specifications and other information contained in this document without prior notice. Every effort has been made to ensure that the information in this document is accurate.

Introduction Net Optics GigaBit Port Aggregator Taps with SFP Monitor Ports provide ultra-efficient access to critical GigaBit links. This pioneering technology enables any two devices to simultaneously monitor a full-duplex link using only one NIC per monitoring device. Small Form Factor Pluggable (SFP) connectors on the Monitor Ports allow these Port Aggregators to also perform media conversion from fiber to copper. Typically, full-duplex monitoring with a network tap requires two NICs (or a dual channel NIC) one interface for each side of the tapped full-duplex connection. The Gigabit Port Aggregator Tap combines and regenerates these streams, sending all aggregated data out one or two passive monitoring ports. The best part of this innovation is the onboard memory that ensures traffic isn't dropped during bursts. The GigaBit Port Aggregator Tap is designed to handle the combined traffic of a single full-duplex link. Normally, the traffic should be below the receiving capacity of the NIC, that is, less than Gbps. When the traffic queue exceeds the capacity of the NIC, the Tap buffers the overflow up to GB. The buffers clear automatically when the traffic volume falls below the receiving capacity of the NIC. For example, if there is a traffic burst and a Tap connected to a Gbps network port on a monitoring device is now receiving. Gbps of traffic, the Tap buffers data until the burst is over. The Tap then sends the buffered data to the monitoring device until the buffer is cleared. Key Features Technology Supports full-duplex monitoring with a single NIC, increasing monitoring efficiency Regeneration Tap technology enables two devices to simultaneously monitor all aggregated traffic using only one NIC per device GB of buffer memory prevents data loss during excessive traffic loads Provides complete full-duplex visibility at Gbps without data stream interference or introducing a point of failure

Passes all traffic (including errors) from all layers for comprehensive troubleshooting No IP address is needed for the Tap or monitoring device, enhancing monitoring security Redundant power ensures monitoring uptime Fully RoHS compliant Ease of Use LED indicators show redundant power, speed, link, and activity status Front-mounted connectors support easy installation and operation Silk-screened application diagram illustrates all connections for easy deployment Optional 9-inch rack frames hold up to two Taps Small form-factor pluggable (SFP) monitor port connectors increase monitoring options Available with -48 VDC power Tested and compatible with all major manufacturers monitoring devices, including protocol analyzers, probes, and intrusion detection/prevention systems Support Net Optics offers free technical support throughout the lifetime of your purchase (and has done so since our start in 996!). Our technical support team is available from 8 am to 5 pm Pacific Time, Monday through Friday at + (408) 737-7777 and via email at ts-support@netoptics.com. FAQs are also available on Net Optics website at www.netoptics.com. Unpacking and Inspection Carefully unpack the GigaBit Fiber Port Aggregator Tap and check for damaged or missing parts. The Port Aggregator Tap ships with the following: GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports Two SC to SC fiber cables Two power supplies (AC power models) Installation Guide In addition to the Port Aggregator, you should have ordered one or two Giga- Bit SFP modules. You may have also ordered an extended warranty. Carefully check the packing slip against parts received. If any part is missing or damaged, contact Net Optics' Customer Service immediately.

About this Guide This Guide provides you all the information you need to install and operate the GigaBit Fiber Port Aggregator Tap. Please read the entire Guide before attempting to install or operate the Tap. This Guide covers the following models: Part Number TPA-SX4-SFP TPA-SX5-SFP TPA-LX4-SFP TPA-LX5-SFP TPA-50SX5-SFP Description GigaBit Port Aggregator, multimode SX fiber, 60/40 split ratio, two SPF monitor ports GigaBit Port Aggregator, multimode SX fiber, 50/50 split ratio, two SPF monitor ports GigaBit Port Aggregator, singlemode LX fiber, 60/40 split ratio, two SPF monitor ports GigaBit Port Aggregator, singlemode SX fiber, 50/50 split ratio, two SPF monitor ports GigaBit Port Aggregator, multimode 50um SX fiber, 50/50 split ratio, two SPF monitor ports Network Ports Monitor Ports with plugs A B Network A B Monitor Port Aggregator LINK www.netoptics.com Power LEDs Link LEDs Product Diagram Figure 4: Front Panel LED Indicators PWR / PWR : Main and Redundant Power. If the Tap is deployed with both power supplies, both LEDs illuminate when the Tap is plugged in. If an LED is off, this indicates that the corresponding power supply is not functioning. Link/Activity Indicators: If a good link is established, the LED illuminates a steady green. If there is current activity on this link, the LED flashes. 3

A B A B GigaBit Fiber Port Aggregator Tap Application Diagrams: Memory Operation All traffic that passes through the Tap is sent to the monitoring device NIC on a first-in, first-out basis, including traffic that is temporarily stored in memory. (If two packets enter at the same time then one packet is processed while the other is stored briefly in memory, preventing collisions.) When there is a burst of data, traffic in excess of the NIC's capacity is sent to the Tap's memory. Up to 5 megabytes of data per side of the full-duplex stream can be stored in memory. Memory continues to fill until its capacity is reached, or the burst ends whichever comes first. In both cases, the Tap applies a first-in, first out procedure, processing stored data before new data from the link. If memory fills before the burst ends, the memory stays filled as the stored data is processed data that leaves the buffer is immediately replaced. If the burst ends before the memory fills, memory clears until the full megabyte of capacity is available, or another until another burst in excess of the NIC's capacity requires additional memory. The following three diagrams illustrate a simple example of a 000 Mbps NIC moving from 80% utilization, to 40% utilization, then back to 80% utilization. State : Side A + Side B is less than or equal to 00% of the NIC's receive capacity. Example: On a 000 Mbps link, Side A is at 300 Mbps and Side B is at 500 Mbps. The NIC receives 800 Mbps of traffic (80% utilization), so no memory is required for the monitoring device NIC to process all full-duplex traffic. Side A GigaBit SX SFP Port Aggregator Tap Router Firewall Side B Side A + Side B Using a single NIC, the monitoring device receives all combined traffic from Side A and Side B, including physical layer errors. Monitoring Device Figure : Aggregated traffic is less than NIC's capacity 4

State : Side A + Side B becomes greater than 00% of the NIC's receive capacity. Example: There is a burst of traffic, so Side A is now at 900 Mbps while Side B remains at 500 Mbps. The NIC's utilization is at 40%, requiring the use of memory to help prevent data loss. Side A GigaBit SX SFP Port Aggregator Tap The extra 400 Mbps of traffic is stored in the 8 megabyte buffer for Port A. Memory continues to fill until the 8 megabyte capacity is reached, or the burst ends. (A separate 8 megabyte buffer is also available to handle a burst on Port B.) Memory Router Side B Monitoring Device Side A + Side B Firewall Using a single NIC, the monitoring device receives 000 Mbps of combined traffic from Side A and Side B, including physical layer errors. Figure : Aggregated traffic is greater than NIC's capacity State 3: Side A + Side B is once again less than 00% of the NIC's receive capacity. Example: On a 000 Mbps link, Side A is again at 300 Mbps and Side B remains at 500 Mbps. The NIC's utilization is again at 80%. Side A GigaBit SX SFP Port Aggregator Tap The Tap applies a first-in, first-out process to all packets. Once the burst has ended and the NIC's utilization is again below 00 percent, the Tap first processes the packets that were stored in memory. As long as the NICʼs utilization remains below 00 percent, this process continues uninterrupted until the memory clears. Memory Router Side B Monitoring Device Side A + Side B Firewall Once the memory has cleared, the monitoring device begins receiving new data directly from the link. Using a single NIC, the monitoring device receives all traffic from Side A and Side B, including physical layer errors. Figure 3: Traffic burst has passed 5

Connecting to the Network Optical connections are extremely sensitive to contaminants. Make sure all optical surfaces are clean before connecting. To connect to the Network Ports:. Remove protective plugs.. Connect Network Port A to the appropriate network device using a Duplex LC cable. 3. Connect Network Port B to the appropriate network device using a Duplex LC cable. 4. Verify that the Tap Network Ports are cabled in-line between two devices. A B Network A B Monitor Port Aggregator LINK www.netoptics.com To network switch or router To network switch or router Figure 4: Connecting to the Network 6

Connecting the Monitoring Device To protect the Port Aggregator Tap, the SFP slots are filled with temporary plugs. If you are installing only one SFP, leave the plug in Monitor Port to protect the Port Aggregator Tap. You must install the SFP before connecting to the monitoring device. To connect the Monitor Ports:. Remove the SFP from its protective packaging.. Remove the temporary plug from Monitor Port. 3. Insert the SFP in the Monitor Port until you hear it click into place. 4. Connect Monitoring Port to the appropriate port on the monitoring device using an RJ45 CAT5e cable to monitor the A and B links. 5. If you are installing two SFPs, repeat Steps through 4 for Monitor Port. A B Network A B Monitor Port Aggregator LINK www.netoptics.com To Monitoring Device Figure 5: Connecting the Monitoring Device 7

Changing the SFP Monitor Port Connector You have the option to change the interface on the Monitor Port by changing the small form-factor plug (SFP) on the Monitor Port. You can order conversion kits which include the singlemode fiber, multimode fiber, GigaBit copper SFP and appropriate cable from Net Optics. For ordering information, see Specifications on page 9. To change the SFP:. Remove the cable from the SFP on the Port Aggregator Tap.. Lower the wire clip to release the SFP connector. 3. With the clip on the lowered position, pull gently on the clip to free the SFP. 4. Insert the new SFP until you hear it click into place. 5. Connect the cable supplied with the kit. Connecting Power The second power supply is available to support the flow of traffic to the monitoring device, in the event that the first power supply becomes unavailable. If the first power supply is unavailable, the second power supply will supply all power for the Tap. Even if no power is available to the passive Tap, network traffic flows uninterrupted.. Supply power to the Tap via the two power connectors on the rear of the unit. Two power supplies are included with the AC power models. The use of the second redundant power supply is optional.. Verify that the Power LEDs illuminate. PWR illuminates when the first power supply is in use, and PWR illuminates when the second power supply is in use. Both power supplies can be plugged into the Tap at the same time. 8

Specifications Optical SX Fiber Type: Corning Multimode 50/5µm or 6.5/5µm, wavelength 850nm LX Fiber Type: Corning Multimode 8.5/5µm, wavelength 30nm Environment Operating Temperature: 0 C to 55 C Storage Temperature: -0 C to 70 C Relative Humidity: 0% min, 95% max, non-condensing Power AC Power Input: 00-40 VAC, 0.5A, 47-63Hz Output: V, 3A DC Power Input: -48 VDC typical, -36 VDC min, -75 VDC max Mechanical Dimensions:.5 high x deep x 8.75 wide Connectors () Duplex LC connectors (network ports) () SFP ports for SFP modular connectors Certifications Fully RoHS compliant Accessories SFP Conversion Kits SFPKT-SX Multimode fiber SFP with cable SFPKT-LX Singlemode fiber SFP with cable SFPKT-GCU GigaBit copper SFP with cable 9

Limitation on Warranty and Liability Net Optics offers a limited warranty for all its products. IN NO EVENT SHALL NET OPTICS, INC. BE LIABLE FOR ANY DAMAGES INCURRED BY THE USE OF THE PRODUCTS (INCLUDING BOTH HARDWARE AND SOFTWARE) DESCRIBED IN THIS MANUAL, OR BY ANY DEFECT OR INACCURACY IN THIS MANUAL ITSELF. THIS INCLUDES BUT IS NOT LIMITED TO LOST PROFITS, LOST SAVINGS, AND ANY INCIDENTAL OR CONSE- QUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PROD- UCT, even if Net Optics has been advised of the possibility of such damages. Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. Net Optics, Inc. warrants this Tap to be in good working order for a period of ONE YEAR from the date of purchase from Net Optics or an authorized Net Optics reseller. Should the unit fail anytime during the said ONE YEAR period, Net Optics will, at its discretion, repair or replace the product. This warranty is limited to defects in workmanship and materials and does not cover damage from accident, disaster, misuse, abuse or unauthorized modifications. If you have a problem and require service, please call the number at the end of this section to speak with our technical service personnel. They may provide you with an RMA number, which must accompany any returned product. Return the product in its original shipping container (or equivalent) insured and with proof of purchase. THE WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHERS, EXPRESS OR IMPLIED. No Net Optics reseller, agent, or employee is authorized to make any modification, extension, or addition to this warranty. Net Optics is always open to any comments or suggestions you may have about its products and/or this manual. Send correspondence to Net Optics, Inc. 5303 Betsy Ross Drive Santa Clara, CA 95054 USA Telephone: + (408) 737-7777 Fax: + (408) 745-779 Email: info@netoptics.com/internet: www.netoptics.com All Rights Reserved. Printed in the U.S.A. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form, by any means, without prior written consent of Net Optics, Inc., with the following exceptions: Any person is authorized to store documentation on a single computer for personal use only and that the documentation contains Net Optics' copyright notice. 0

www.neoptics.com 008 by Net Optics, Inc. All Rights Reserved.