Question Shall the Tender include installation of the central server application on a redundant server?



Similar documents
Domonial, le Sucre. Easy to Use Intruder Detection Systems

Vesta Visual Verification Alarm System - MJ Series. Keeping Home in Sight on Your Smartphone

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

LEARNING SOLUTIONS website milner.com/learning phone

EDL-Portal. Energiedienstleistung

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Associate in Science Degree in Computer Network Systems Engineering

Reducing operating costs of telecom base stations with remote management

AutoLog ControlMan. Remote Monitoring & Controlling Service

White Paper. Wireless FF HSE connection successfully setup at Shell Test Lab. Summary. Overview

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

Product Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors

Storage Guardian Remote Backup Restore and Archive Services

Crow Limited Warranty. Print Version 017

Sensor Monitoring and Remote Technologies 9 Voyager St, Linbro Park, Johannesburg Tel: ;

Smart. Scalable. Simple.

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Network Setup Instructions

Reliable Security Solutions

Tk20 Network Infrastructure

Computer Network & ICT Support Technician

Administering a Microsoft SQL Server 2000 Database

Immotec Systems, Inc. SQL Server 2005 Installation Document

Managing and Maintaining Windows Server 2008 Servers

Application Note: Upgrading Interceptor software with FTP server on local PC

Semaphore T BOX Applications in Data Center Facilities

GE Security. FHSD Monitor / Web Server user manual

USB Edition TM-STD30 User Guide

Continuous, remote monitoring and logging of electromagnetic fields

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Training Program: Network Admin. Program Structure: Hardware and Appliances. Networking

User s Manual Network Management Card

Course 2788A: Designing High Availability Database Solutions Using Microsoft SQL Server 2005

TECHNICAL DESCRIPTION OF THE DISTRIBUTION SUBSTATION REMOTE MONITORING SYSTEM

Configuring and Deploying a Private Cloud with System Center 2012 MOC 10751

IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited

VST-1815Z IP V-Alarm System VST-1852Z IP/GPRS V-Alarm System

USB Ethernet Connectivity Kit

Administering a Microsoft SQL Server 2000 Database

Home Passport Gateway Series Simplify your Life with Smart Solutions

Xactimate v.27 Network Installation

White Paper ClearSCADA Architecture

SCADA and Monitoring for Solar Energy Plant

Kokii BatteryDAQ. BMS Software Manual. Battery Analyzer Battery DAS

Radiological Assessment Display and Control System

R3: Windows Server 2008 Administration. Course Overview. Course Outline. Course Length: 4 Day

Cellular Edition TM- CELL400 User Guide. 1 TM- CELL400 Rev Temperature@lert

Ultra Thin Client TC-401 TC-402. Users s Guide

Ultimate Server Client Software

securityprobe 5E Standard

How To Install And Set Up The Database For Quicdoc And Office Therapy (The Applications)

Installation and Connection Guide to the simulation environment GLOBAL VISION

OSM 2007 MONITORING SOFTWARE

Acquiring i data from the field level l to a SQL database

Security Alarm Systems

Bidirectional wireless communication using EmbedRF

StruxureWare TM Data Center Expert

Common Questions & Answers

Print Audit 6 - SQL Server 2005 Express Edition

Network Client. Troubleshooting Guide FREQUENTLY ASKED QUESTIONS

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

MCAPS 3000 DISASTER RECOVERY GUIDE

How To Set Up Safetica Insight 9 (Safetica) For A Safetrica Management Service (Sms) For An Ipad Or Ipad (Smb) (Sbc) (For A Safetaica) (

Virtual Server in SP883

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

RAS Associates, Inc. Systems Development Proposal. Scott Klarman. March 15, 2009

HMS Industrial Networks. Putting industrial applications on the cloud

Environmental data Temperature: -20 C to +55 C (Operating) -55 C to +85 C (Storage) Humidity: 0 95%

Managing Mobile Devices Over Cellular Data Networks

- Monitoring Array: a seismic or infrasound array, including from 1(4) to 20 Remote Elements (RE) and one Central Recording Facility (CRF).

CONSTRUCTION / SERVICE BILLING SYSTEM SPECIFICATIONS

PowerCommand iwatch 100 Remote Network Monitoring

World Food Programme. Grasp Manual. An Overview

Data Logger & Net Client Software (Windows, ipad, Android) Instant On. Touch. Drop & Drag Opera on. No more proprietary display equipment!

Ethernet Adapter Owner's Manual

Patriot Hardware and Systems Software Requirements


PCMCIA Wireless LAN Card User s Manual

Safexpert Installation instructions MS SQL Server 2008 R2

Ranch Networks for Hosted Data Centers

Your Technical Point of Contact s Role

RFQ IT Services. Questions and Answers

MCSE: Private Cloud Training Course (System Center 2012)

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

Microsoft Technologies

Technical Overview CM-2 Climate Monitor. Get yours direct at:

Premium Server Client Software

VS-100. PoE. H.264 PoE Video Server. H.264 Compression H.264 DI/DO. Compression Rate Comparison MJPEG MPEG4 H.264.

PLC GPRS NET Data Logger

How To Use Netbiter

Technical Overview CM-16 Climate Monitor. Get yours direct at:

Transcription:

s and answers regarding the Invitation for Tender for a national gamma monitoring system in Sweden s and answers published 2008-07-07 Will alternative tenders from the same Tenderer be considered? No, only the Tender that fulfils all financial, economical and technical requirements and has the lowest price will be selected for further comparison with Tenders from other Tenderers. Can a Tenderer offer different types of sensors and thereby provide an opportunity for the Swedish Radiation Safety Authority to select the one that is best suited? No, only the Tender that fulfils all financial, economical and technical requirements and has the lowest price will be selected for further comparison with Tenders from other Tenderers. Will a more advanced system than specified in the technical requirements be beneficial in the evaluation? No, in the evaluation process, Tenders will only be checked to verify if they fulfil all financial, economical and technical requirements or not. A more advanced solution than required will not give any additional points in the evaluation process. Will different options from the same Tenderer be considered? No, only the Tender that fulfils all financial, economical and technical requirements and has the lowest price will be selected for further comparison with Tenders from other Tenderers. Shall the necessary hardware for the central server application be included in the Tender? No, but any necessary additional hardware or software required to receive and transmit data between the central server application and the measurement stations shall be specified in the Tender. It states in the technical requirement specification that the central server application shall be able to work on a redundant server. How shall this requirement be interpreted?

It shall be possible to install the central server application on a redundant server at a later time at the request of the Swedish Radiation Safety Authority. Shall the Tender include installation of the central server application on a redundant server? No, the Tender shall only include installation of the central server application on one server at the Swedish Radiation Safety Authority. Shall the Tender include installation of the client software on workstations at the Swedish Radiation Safety Authority? Yes, the Tender shall include installation of the client software on five workstations placed at the Swedish Radiation Safety Authority. It states in the technical requirement specification that the central server application shall be able to store data in a Microsoft SQL database. Is this correct? The requirement shall be interpreted as the ability to store data in a Microsoft SQL server database. It states in the technical requirement specification that the measurement station shall be able to measure the operating temperature. Does this refer to the outdoor temperature or the temperature inside the measurement station? The measurement station shall be able to measure the temperature inside the measurement station. If a solution with separate units for control, detector and backup battery is offered, the measurement station shall be able to measure the temperature inside the detector unit. It states in the technical requirement specification that the quality information of the measurement station shall include, among other parameters, internal humidity status and internal temperature status. What do the terms internal and status refer to and shall the measurement station be able to measure humidity? The measurement station shall be able to measure and register the temperature and humidity inside the measurement station. If a solution with separate units for control, detector and backup battery is offered, the measurement station shall be able to measure and register the temperature and humidity inside the detector unit. The term status refers to the actual value of the temperature or humidity measurement, not the status of the temperature or humidity sensor.

Shall the measurement station be able to measure precipitation type? No. Shall the measurement station be able to measure wind speed and wind direction? No. Shall the Tender include all software upgrades for three years following the delivery or only corrections of identified faults in the software caused by the Tenderer? The Tender shall include all upgrades of the software for three years following the delivery. s and answers published 2008-07-10 The specified measurement range for the precipitation measurement is down to 10 C. Shall the precipitation sensor be able to correctly measure the amount of precipitation in form of snow? : Yes. Regarding the requirement for Power Supply External Interface; What is the length of the mains power cable to be offered? : The mains power cable shall be at least five (5) meters. The mains power cable shall have type approval H07RN-F, H07BQ-F or better. Regarding the requirement for Power Supply External Interface; What is the required type of mains power connector to be offered? : The mains power connector shall be of CEE form with 3 pins and designed for 220-240V and 16A. Regarding the requirement for Power Supply External Interface; What is the required protection class of the mains power connector? : The protection class of the mains power connector shall be IP 44 or better.

Regarding the requirement for Set and Modify Parameters Locally; What is the difference between process parameters and configuration parameters? : There is no clear difference between process and configuration parameters. In the invitation for Tender, process parameters are e.g. parameters for the statistical analysis of the data and configuration parameters are e.g. parameters for setting up the detector(s) and sensor(s). The requirement shall be interpreted in such a way that it shall be possible to set and modify relevant parameters for the operation of the measurement station locally using an external PC that has established a local connection to the measurement station. Regarding the requirement for Protection Class; Is IP67 also valid for the precipitation sensor or is IP65 sufficient? : The precipitation sensor shall have a protection class of IP 67 or better. Regarding the requirement for Redundant Server; Looking at the software components at least three (3) main components can be identified in the central system: - FTP server for GPRS / TCP/IP communication - Server application software - SQL database Please specify which of these components should be installed on a redundant hardware? : The requirement shall be interpreted in such a way that it shall be possible to install the central server application on a redundant server at a later time at the request of the Swedish Radiation Safety Authority. The installation of the above mentioned components on a redundant server shall therefore not be included in the Tender. Regarding the requirement for Redundant Server; Please specify the PC hardware system on which it shall be possible to install the software? : The central server application shall be able to run on a redundant server with Intel x86 architecture and Microsoft Windows Server 2003. Regarding the requirement for Database; Shall the database also fulfil the redundancy requirement, thus be installed on different (redundant) server with automatic database replication between each other and, if f yes, does the Tenderer has to provide the setup of the database replication or is this provided by SSI IT department? : No, the database shall not fulfil the redundancy requirement. The setup of the database replication shall not be included in the Tender. This is provided by the Swedish Radiation Safety Authority using a separate system not included in the Invitation for Tender.

Regarding the requirement Receive and Transmit Data; Is a FTP server available on the SSM hosted website and can this be used for the data transmission if a FTP server is necessary for the data transmission by GPRS? : The Swedish Radiation Safety Authority will provide the necessary hardware to receive and transmit data between the central server application and the measurement stations. Standard communication protocols, such as an FTP server or a Web server will be available. It shall be clearly stated in the Tender if a non-standard communication protocol is needed to receive and transmit data between the central server application and the measurement stations. Is the Tenderer responsible for provision/setup of the public FTP-server or is this provided by SSM? : See previous answer. Is SSI providing the necessary security for the GPRS/internet communication (Firewall ) or is this in the responsibility of the Tenderer? : The Swedish Radiation Safety Authority will provide the necessary security for the GPRS/internet communication. Regarding the requirement Report Generation; Shall the described report function be an automatic process which creates time scheduled reports automatically (i.e. automatic daily report) or is the report to be created automatically upon users request? : The central server application shall be able to create time scheduled reports automatically. Regarding the requirement Alarm Notification; Is it acceptable to use an internet service provider, who provides a conversion from email to SMS for the generation of SMS? : Yes. s and answers published 2008-08-06 Regarding the requirement Endurance Temperature; Shall the monitoring station be able to withstand ambient air temperatures between -50 ºC and +50 ºC without being damaged even in the event of a mains power supply failure in combination with a backup battery failure? : The requirement regarding Endurance Temperature must only be fulfilled given that the measurement station get power from either the external power supply or the backup battery.

Is it required to measure the temperature in the housing for the electronics if the detector(s) is placed separate from the housing or is it sufficient to measure the temperature only in the detector unit? : See answer to previous question concerning the temperature measurement published on the website of the Swedish Radiation Safety Authority on the 7 th of July 2008. The measurement station shall be able to measure the temperature inside the measurement station. If a solution with separate units for control, detector and backup battery is offered, the measurement station shall be able to measure the temperature inside the detector unit. Regarding the requirement on Receive and Transmit Data and the answer concerning this requirement published on the website of the Swedish Radiation Safety Authority on the 10 th of July 2008; Shall the hardware at the measurement stations necessary to receive and transmit data between the central server application and the measurement stations be included in the Tender? : The hardware at the measurement stations necessary to receive and transmit data between the central server application and the measurement stations shall be included in the Tender. The Swedish Radiation Safety Authority will provide the necessary hardware for the central server application to receive and transmit data between the central server application and the measurement stations. If a technical solution where a certified dose rate detector is placed inside a housing is chosen; Must the dose rate measurement for the housing with the detector inside be certified in itself? All requirements in the technical requirement specification shall be fulfilled regardless of chosen technical solution for the measurement station. Regarding the tender procedure and the related terms of delivery; Has the Swedish Radiation Safety Authority already a fixed or final date for the contract award decision, as the offer should be valid at least 90 days and the date of delivery must be before December 31, 2008. The Swedish Radiation Safety Authority will make the contract award decision as soon as possible and not later than the 4th of September 2008. The deadline for delivery of the proposal is indicated as "before August 13th"; Please clarify if the proposal package has to be delivered before 17.00 of August 12th or August 13th. The deadline for delivery of a Tender to the Swedish Radiation Safety Authority is at 17.00 on the 13 th of August 2008.