EX-A1 I/O Expansion Module Adapter

Similar documents
When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

UniStream CPU-for-Panel

OPLC Installation Guide

Screen 3.5" Color Touch 4.3" Color Touch Keypad or Function Keys Programming Com Port, Built-in

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Advantium 2 Plus Alarm

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

INSTALLATION INSTRUCTIONS

ZC-24DO CANopen I/O Module: 24 Digital Outputs

CQM1-SF200/CS1W-SF200

About this Manual. Support for Your Product

Provides one channel for Ethernet over existing

AXIS T81B22 DC 30W Midspan

MCR1900 Media Converter 19-Slot Chassis

Modular I/O System Analog and Digital Interface Modules

Sunny Boy Accessories SMA POWER BALANCER

CompactLogix Power Supplies Specifications

The power module is Feature Number 8800-F2-901.

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

12 Volt 30 Amp Digital Solar Charge Controller

Single Station Remote Alarm

Universal Serial Bus (USB) to DH-485 Interface Converter

Vision OPLC. V R34/V350-J-R34 Technical Specifications. Technical Specifications

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

StructureScan HD Module. Installation Guide ENGLISH

Provides one channel for Ethernet over existing

DLP-PU/E Instruction Manual

3M Wrist Strap and Footwear Tester 740. User s Guide

C13 User Manual Document ID: 2CMC486004M0201 Revision: A

Digital input modules

StorTrends 3400 Hardware Guide for Onsite Support

Model 201 Wiegand Touchpad Reader Installation Guide

T7560A,B,C Digital Wall Module

BroadBand PowerShield. User Manual

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

Wall-Mounting your HP computer. User Guide

=============================== WARNING

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

12-Volt 10-Amp Regulated Power Supply

Manual. Simrad StructureScan LSS-1 Sonar Module. English

HMI display Installation Guide

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

CompactRIO crio-9052

Square D Clipsal Two-Channel DIN-Rail DALI Gateway

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Manual. Solar Fountain Mobile Phone Charger

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

User Guide. HDMI Active Cable Extender. DVI-7370c

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

About the BitStorm 6051 POTS Splitter

16/32 Channel 1U Rack Mount CCTV Power Supply

DMX2PWM 9 Channel Dimmer Setup Manual

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

How To Install A Power Supply (Uplast) With A Battery Pack

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

LIEBERT VNSA Installation Sheet

PSACH v.1.0 PSACH 24VAC/6A/1x6A HERMETIC AC power supply for CCTV

ADM1TE 5/30A DIN rail single phase two wire energy meter

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Duct Humidity Transmitter

Square D Clipsal C-Bus Network Analyzer

Installation guide H A. HSI hardwired system interface

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Users manual. TCW181B-CM_R1 Page 1

Original instructions Tina 3A/Aps Adaptor unit

Part I - Installation

PCS0100en Persy Control Services B.V. Netherlands

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

ECM-30 30A AC Power Module Spike Suppressor

Wireless Indoor/ Outdoor Thermometer

SYSTEM DESCRIPTION Termination Boards

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

RAY-MAX Integrated Solar Power Strip

T-Extender E-Extender

Tina 2A/B Adaptor unit

Compaq Presario Desktop Products. Upgrading and Servicing Guide

User s Guide OSXL-100-PE. Thermal Imaging Camera Enclosure. Shop online at omega.com SM

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

User Manual Revision English

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera

YSmart Technology Co.,Ltd

alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

EXTERNAL DIMENSIONS AND PARTS

Old Company Name in Catalogs and Other Documents

Triple Expansion Chassis

Transcription:

EX-A1 I/O Expansion Module Adapter The EX-A1 interfaces between a variety of I/O expansion modules and specific Unitronics OPLCs. A single adapter can be connected to up to 8 expansion modules. The EX-A1 may either be snap-mounted on a DIN rail, or screw-mounted onto a mounting plate. 1 4 Component identification 1 Status indicators OPLC to EX-A1 connection port 3 Power supply connection points 4 EX-A1 to expansion module connection port POWER 3 Before using this product, it is the responsibility of the user to read and understand this document and any accompanying documentation. All examples and diagrams shown herein are intended to aid understanding, and do not guarantee operation. Unitronics accepts no responsibility for actual use of this product based on these examples. Please dispose of this product in accordance with local and national standards and regulations. Only qualified service personnel should open this device or carry out repairs. User safety and equipment protection guidelines This document is intended to aid trained and competent personnel in the installation of this equipment as defined by the European directives for machinery, low voltage, and EMC. Only a technician or engineer trained in the local and national electrical standards should perform tasks associated with the device s electrical wiring. Symbol Meaning Description Symbols are used to highlight information relating to the user s personal safety and equipment Danger protection throughout this document. When these symbols appear, the Warning associated information must be read carefully and understood fully. Caution Caution Use caution. The identified danger causes physical and property damage. The identified danger can cause physical and property damage. Failure to comply with appropriate safety guidelines can result in severe personal injury or property damage. Always exercise proper caution when working with electrical equipment. Unitronics Industrial Automation 1

EX-A1 I/O Expansion Module Adapter 7/03 Check the user program before running it. Do not attempt to use this device with parameters that exceed permissible levels. Install an external circuit breaker and take appropriate safety measures against short-circuiting in external wiring. To avoid damaging the system, do not connect / disconnect the device when the power is on. Environmental Considerations Do not install in areas with: excessive or conductive dust, corrosive or flammable gas, moisture or rain, excessive heat, regular impact shocks or excessive vibration. Mounting the Module Leave a minimum of 10mm space for ventilation between the top and bottom edges of the device and the enclosure walls. Do not place in water or let water leak onto the unit. Do not allow debris to fall inside the unit during installation. DIN-rail mounting Snap the device onto the DIN rail as shown below; the module will be squarely situated on the DIN rail. 93mm (3.66") POWER 3.5mm (0.137") 44.5mm (1.75") 14mm (0.55") 60mm (.36") 80mm (3.15") Screw-Mounting The figure on the next page is drawn to scale. It may be used as a guide for screw-mounting the module. Mounting screw type: either M3 or NC6-3. Unitronics Industrial Automation

7/03 EX-A1 I/O Expansion Module 5.8mm (0.8") 4mm (0.16") 80mm (3.15") 68.4mm (.693") 93mm (3.66") 85mm (3.346") 4mm (x) (0.16") Unitronics Industrial Automation 3

EX-A1 I/O Expansion Module Adapter 7/03 Connecting the OPLC to the EX-A1 An OPLC, such as the M90 micro-oplc, is connected to the EX-A1 adapter as shown below, via a category 5 shielded twisted pair cable (CAT 5, STP), terminated by RJ45 connectors. The cable provided with the EX-A1 is one meter long; cables of other lengths are available by separate order. Note that the cable must be earthed on the M90 side, via the yellow-green wire. To avoid damaging the system, do not connect or disconnect the device when the power is on. M90 EX-A1 Earth POWER I/O expansion port Shielded RJ45 connector pin-out Cable description Pin #1 RJ-45 pin # 1 8 4 3 6 signal RJ-45 RJ-45 D - D + CK- CK+ 0V 0V 1 8 4 Connect to earth near the M90 1 8 4 4 Unitronics Industrial Automation

7/03 EX-A1 I/O Expansion Module Connecting Expansion Modules An adapter provides the interface between the OPLC and an expansion module. To connect the I/O module to the adapter or to another module: 1. Push the module-to-module connector into the port located on the right side of the device. Note that there is a protective cap provided with the adapter. This cap covers the port of the final I/O module in the system. To avoid damaging the system, do not connect or disconnect the device when the power is on. Component identification 1 Module-to-module connector Protective cap 1 Wiring Do not touch live wires. Wiring Procedures Unused pins should not be connected. Ignoring this directive may damage the device. Double-check all wiring before turning on the power supply. Do not connect the Neutral or Line signal of the 110/0VAC to the device s 0V pin. In the event of voltage fluctuations or non-conformity to voltage power supply specifications, connect the device to a regulated power supply. Double-check all the wiring before turning on the power supply. Use crimp terminals for wiring; use 6-1 AWG wire (0.13 mm 3.31 mm ) for all wiring purposes. 1. Strip the wire to a length of 7±0.5mm (0.50 0.300 inches).. Unscrew the terminal to its widest position before inserting a wire. 3. Insert the wire completely into the terminal to ensure that a proper connection can be made. 4. Tighten enough to keep the wire from pulling free. To avoid damaging the wire, do not exceed a maximum torque of 0.5 N m (5 kgf m). Do not use tin, solder, or any other substance on stripped wire that might cause the wire strand to break. Install at maximum distance from high-voltage cables and power equipment. Unitronics Industrial Automation 5

EX-A1 I/O Expansion Module Adapter 7/03 Wiring Power Supply 1. Connect the "positive" cable to the "+V" terminal, and the negative to the "0V" terminal. A non-isolated power supply can be used provided that a 0V signal is connected to the chassis. Note that both the OPLC and the EX-A1 must be connected to the same power supply. POWER 1VDC or 4VDC power supply 0V +V Circuit protection device EX-A1 Technical Specifications I/O module capacity Up to 8 I/O modules can be connected to a single adapter. Power supply 1VDC or 4VDC (see Notes 1 and ) Permissible range 10. to 8.8VDC Max. current consumption 650mA @ 1VDC; 350mA @ 4VDC Typical power consumption 4W Current supply for I/O modules 1A max. from 5V (see Note 3) Galvanic isolation None Status indicators (PWR) Green LED Lit when power is supplied. (COMM.) Green LED Lit when communication is established. Environmental IP0/NEMA1 Operating temperature 0 to 50 C (3 to 1 F) Storage temperature -0 to 60 C (-4 to 140 F) Relative Humidity (RH) 5% to 95% (non-condensing) Dimensions (WxHxD) 80mm x 93mm x 60mm (3.15 x 3.66 x.36 ) Weight 15g (4.3oz.) Mounting Either onto a 35mm DIN-rail or screw- mounted. Notes: 1. Both the OPLC and the EX-A1 must be connected to the same power supply. The EX-A1 and the OPLC must be turned on and off simultaneously.. The 1VDC power supply is supported by versions V.00 and later. 3. Example: I/O-DI8-TO8 units consume a maximum of 140mA of the 5VDC supplied by the EX-A1. 6 Unitronics Industrial Automation

7/03 EX-A1 I/O Expansion Module Accessories EX1-CA050 0.5 meter communication cable EX1-CA100* 1 meter communication cable EX1-CA00 meter communication cable EX1-CA400 4 meter communication cable IO-CAP Protective cap, used to cover the connection port of the final I/O module in the system *EX1-CA100 is provided with the EX-A1 adapter; other cables are available by separate order. Addressing I/Os on Expansion Modules Inputs and outputs located on I/O expansion modules that are connected to an OPLC are assigned addresses that comprise a letter and a number. The letter indicates whether the I/O is an input (I) or an output (O). The number indicates the I/O s location in the system. This number relates to both the position of the expansion module in the system, and to the position of the I/O on that module. Expansion modules are numbered from 0-7 as shown in the figure below. Adapter 0 1 3 4 5 6 7 Expansion module identification number The formula below is used to assign addresses for I/O modules used in conjunction with the OPLC. X is the number representing a specific module s location (0-7). Y is the number of the input or output on that specific module (0-15). The number that represents the I/O s location is equal to: 3 + x 16 + y Examples Input #3, located on expansion module # in the system, will be addressed as I 67, 67 = 3 + 16 + 3 Output #4, located on expansion module #3 in the system, will be addressed as O 84, 84 = 3 + 3 16 + 4. EX90-DI8-RO8 is a stand-alone I/O module. Even if it is the only module in the configuration, the EX90-DI8- RO8 is always assigned the number 7. Its I/Os are addressed accordingly. Example Input #5, located on an EX90-DI8-RO8 connected to an OPLC will be addressed as I 149, 149 = 3 + 7 16 + 5 Unitronics Industrial Automation 7

EX-A1 I/O Expansion Module Adapter 7/03 About Unitronics Unitronics Industrial Automation Systems has been producing PLCs, automation software and accessory devices since 1989. Unitronics OPLC controllers combine full-function PLCs and HMI operating panels into single, compact units. These HMI + PLC devices are programmed in a single, user-friendly environment. Our clients save I/O points, wiring, space, and programming time; elements that translate directly into cost-efficiency. Unitronics supports a global network of distributors and sales representatives, as well as a U.S. subsidiary. For more information regarding Unitronics products, contact your distributor, Unitronics headquarters via email: export@unitronics.com, or visit the Unitronics website at http://www.unitronics.com/. Under no circumstances will Unitronics be liable or responsible for any consequential damage that may arise as a result of installation or use of this equipment, and is not responsible for problems resulting from improper or irresponsible use of this device. No part of this document may be used for any purpose other than for the purposes specifically indicated herein nor may it be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and/or recording, for any purpose without written permission from Unitronics. The information appearing in this document is for general purposes only. Unitronics makes no warranty of any kind with regard to the information appearing in this document, including, but not limited to, 0implied warranties of merchantability and/or fitness for a particular use or purpose. Unitronics assumes no responsibility for the results, direct and/or indirect, of any misuse of the information appearing in this document nor for any use of the Unitronics products referred to herein in any manner deviating from the recommendations made in this document. Unitronics assumes no responsibility for the use of any parts, components, or other ancillary appliances including circuitry other than as recommended hereunder or other than that embodied in the Unitronics product. Unitronics retains all rights to its proprietary assets including, but not limited to its software products which are copyrighted and shall remain the property of Unitronics. Copyright protection claimed includes all Forms and matters of copyrightable materials and information legally allowed including but not limited to material generated from the software programs which are displayed on the screen of the Unitronics products such as styles, templates, icons, screen displays, looks, etc. Duplication and/or any unauthorized use thereof are strictly prohibited without prior written permission from Unitronics. All brand or product names are used for identification purpose only and may be trademarks or registered trademarks of their respective holders. Unitronics reserves the right to revise this publication from time to time and to amend its contents and related hardware and software at any time. Technical updates (if any) may be included in subsequent editions (if any). Unitronics product sold hereunder can be used with certain products of other manufacturers at the user s sole responsibility. 5408-000-1 8 Unitronics Industrial Automation