Vickers. Servo Valves. Servo Electronics. Amplifiers, Power Supplies, Function Modules, and Controllers. Rev. 11/97



Similar documents
Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

SYSTEM 4C. C R H Electronics Design

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

Option field bus: without bus with profibus DP. Design-Index (Subject to change)

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Analog Servo Drive 25A8

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Ordering Part Numbers:

SYSTEM 45. C R H Electronics Design

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

DCS Series 1 kw, 1.2 kw, & 3 kw

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Series Six Plus Programmable Controller

Programmable Single-/Dual-/Triple- Tone Gong SAE 800

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

MODEL 2202IQ (1991-MSRP $549.00)

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

FREQUENCY RESPONSE ANALYZERS

1.44 kw Programmable DC Power Supplies XLN Series

F2400 FOM II Series Fiber Optic Modem Technical Manual

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

M68EVB908QL4 Development Board for Motorola MC68HC908QL4

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

650W Single Output Power Supply

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

SX460. Generator Automatic Voltage Regulator Operation Manual

Application Note TMA Series

Model: DC-A2IO Advanced HVAC Controller

Modular I/O System Analog and Digital Interface Modules

TEP 200WIR Series, Watt

TECHNICAL DATASHEET #TD1000AX DUAL SOLENOID MULTIFUNCTION VALVE DRIVER With Joystick, Potentiometer and Control System Interface P/N: DSDA-SMB Series

DPI 260 SERIES: Digital Pressure Indicators

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Uninterruptible Power Supply

LM1084 5A Low Dropout Positive Regulators

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

LM138 LM338 5-Amp Adjustable Regulators

MasterINTERFACE 39 Series - Relay interface modules

ZC-24DO CANopen I/O Module: 24 Digital Outputs

NC-12 Modbus Application

Current Loop Tuning Procedure. Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) General Procedure AN-015

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Series AMLDL-Z Up to 1000mA LED Driver

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

EFC Frequency converters

MCR1900 Media Converter 19-Slot Chassis

Power Supplies 3. SDN-P DIN Rail Series

DRM compatible RF Tuner Unit DRT1

O C M III. Open Channel Flow Monitor

TOA 900 SERIES II MIXER POWER AMPLIFIER

Advanced Monolithic Systems

Harris IRT Enterprises Digital Resistance Tester Model XR

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Programming Logic controllers

CA723, CA723C. Voltage Regulators Adjustable from 2V to 37V at Output Currents Up to 150mA without External Pass Transistors. Features.

FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3

SL Series AC and DC Electronic Loads

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Current Loop Application Note 1495

F(t) Forssell Technologies Inc

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Contents. Safety Warnings... 1


Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

LOXONE 12 Channel Amplifier

SKF Machine Condition Transmitters (MCT) Series

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

Contents. Document information

Digital Single Axis Controller

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

DMX512 TO 0-10 VOLT ANALOG CONVERTER OWNERS MANUAL

ABB Drives. User s Manual HTL Encoder Interface FEN-31

HITACHI INVERTER SJ/L100/300 SERIES PID CONTROL USERS GUIDE

MACHINEMATE. CNC SYSTEM Hardware SPECIFICATION

Supertex inc. HV Channel High Voltage Amplifier Array HV256. Features. General Description. Applications. Typical Application Circuit

X8 Option 2 - Technology

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

Multifunction devices

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

Electronics. Discrete assembly of an operational amplifier as a transistor circuit. LD Physics Leaflets P

Multi-Range Programmable DC Power Supplies 9115 Series

Section 3. Sensor to ADC Design Example

Multi-function Card. 1 Description. 2 Technical data ESSK General. 1.2 Application example

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

DATA SHEET. TDA8560Q 2 40 W/2 Ω stereo BTL car radio power amplifier with diagnostic facility INTEGRATED CIRCUITS Jan 08

Transcription:

Vickers Servo Valves Servo Electronics Amplifiers, Power Supplies, Function Modules, and Controllers Rev. 11/97 656

Introduction Vickers amplifiers, power supplies, and function modules provide a convenient and economical package of electronics for closed loop servo control. These electronic components have been specially designed and assembled for high reliability and improved ease of use. They can be applied in systems utilizing Vickers servovalves and proportional valves and may also be used to control competitors valves. EM series power supplies and the SMC 20H controller are panel mounted. EM series amplifiers and function modules plug into fully compatible slots in the EMRS-A-11 and EMP-A-20 power supply units. The EEA series amplifiers are designed for use in a standard rack mount. For accurate and repeatable system performance with assured component compatibility, trust Vickers servo electronics. Contents EM-D-30 Servo Amplifier with PID................................................................................ 3 EM-K-10 Ramp Module......................................................................................... 6 EM-J-10 Programmer Module................................................................................... 10 EMRS-A-11 Power Supply Unit.................................................................................. 13 EMP-A-20 Power Supply Unit................................................................................... 16 EEA-PAM-591 Amplifiers....................................................................................... 18 EEA Accessory Products....................................................................................... 22 SMC 20H Two-Axis Hydraulic Position Controller.................................................................. 23 Eaton Hydraulics, Incorporated 2000 All Rights Reserved

EM-D-30 Servo Amplifier with PID Circuit and Connections INTEGRATOR RESET 11 3 4 RESET SATURATION LIMITER +12V COMMON 12V REGULATOR +20V 3 COMMON 20V COMMAND ERROR LIMIT ALARM VOLTAGE AMP SUMMING JUNCTION 10 5 6 + INPUT BIAS ADJ VOLTAGE AMP INPUT 1 8 ±10 100K VOLTAGE AMP 9 INPUT 2 EITHER RATIO CURRENT LOOP INPUT 1 1 OPTO- ISOLATED OUTPUT S12 A B A B S33 10K S36 100K ERROR ADJ S34 S35 100K + GAIN= 1 INPUT BUFFER IGAIN RANGE S21 HIGH S22 LOW S23 OFF INTEGRATOR POWER STAGE PRE-AMP POWER STAGE CURRENT FEEDBACK ±4.20 max. 250 S11 DGAIN LIMITER 2 CURRENT LOOP RANGE 2 INPUT 2 S24 HIGH DGAIN S25 100K LOW S26 OFF D PGAIN S13 S32 A 1:1 P 5:1.8:1 B IGAIN I PROPORTIONAL SATURATION +LIMITER ADJ LIMITER ADJ GAIN DITHER ADJ BIAS ADJ AC 1 2 VALVE COIL VOLTAGE AMP OUTPUT POWER STAGE PRE-AMP INPUT 1 POWER STAGE PRE-AMP INPUT 2 V 4 5 DIFFERENTIATOR S31 51K 51K POWER STAGE PRE-AMP OUTPUT 7 EM-D-30 CONTACTS TERMINAL CARD EMP-A-20, EMRS-A-11 TERMINALS Operating Data The EM-D-30 amplifier module is an extended version of the EM-D-20 amplifier. It is functionally and pin for pin downward compatible. Adjustment of current limiters and bias in the output stage allows the unit to drive single-polarity and bipolar servo valves as well as other current controlled valves. By selection of the appropriate switches, inputs can be inverted in a number of combinations, including the ratioing of two inputs and the introduction of a new current loop input. Excessive following error or in-position can be monitored by means of an adjustable onboard detection circuit which includes an opto-coupled output. Inversion: Each of the four stages of the EM-D-30 amplifier inverts the input polarity. Valve output current can be inverted by input inversion switches S1-1 and S1-2. Reset: When pin 11 is grounded, the integrator reset function is activated causing the integrator amplifier output to maintain zero. An open on pin 11 restores normal operation. With reset ON, the P and D amplifiers still function normally. 3

Specifications Power Stage Output (pins 1 and 2) Inputs 1 and 2: Range Bias range Gain range Dither range Absolute maximum Drift due to temperature Drift versus supply voltage Warm-up drift (after 30 minutes) Frequency response Power Pre-amp Stage Output (pin 7) Gain Limiting Voltage Amplifier Stage Output (pin 6) Inputs 1 and 2: Range Absolute maximum Gain ranges (ratio potentiometer centered): Linear, low range Linear, high range Integrating, low range Integrating, high range Differential, low range Differential, high range Current loop Drift due to temperature Drift versus supply voltage Warm-up drift (after 30 minutes) Drift versus time (after 24 hours) Error detection Mass (weight) ±600 ma into 20 ohm load ±10V DC ±36V DC ±400 ma 100 to 1600 ma/volt 0 to 60 ma 0,4 ma/ C (0.2 ma/ F) at maximum gain 0.001 ma/v at maximum gain at null 0.1 ma 3 db down at 6 khz, maximum gain ±6V DC at 5 ma 1 to 15 V/V ±0V DC to 6V DC ±10V DC at 2 ma ±10V DC ±36V DC 0.08 to 1.1 V/V 0.5 to 3.5 V/V 1.5 to 21.5 V/sec-V 9.6 to 133 V/sec-V 1.5 to 20 V-sec/V 10 to 150 V-sec/V 0 to 20 ma input 0.0002 V/V at maximum gain 0.0001 V/V at maximum gain 0.004V DC 0.005V DC Opto-coupled alarm output, error limit adjustable from ±0 to 10V DC 2,2 kg (1 lb) Vickers, Incorporated 1997 All Rights Reserved

Installation Dimensions millimeters (inches) 89,0 (3.50) OUTPUT BIAS DITHER +LIMIT GAIN LIMIT INPUT BIAS PGAIN IGAIN DGAIN RATIO ERROR A S1 B S2 S3 1 C1 2 C3 3 C2 1 2 3 4 5 6 OPEN 1 2 3 4 5 6 OPEN 3,0 (0.12) Minimum clearance 9,7 (0.38) 32,5 (1.28) 62,0 (2.44) 127,0 (5.00) 32,5 (1.28) 30,0 (1.18) 1,57 (0.06) Polarizing slot 5

EM-K-10 Ramp Module Circuit and Connections First stage output Ramp no. 1 input Ramp no. 2 input Extended ramp input EM-K-10 External capacitor Limiter Ramp no. 1 Ramp no. 2 Output Input 51K Output trim Ramp module contacts EMRS-A-11 or EMP-A-20 power supply unit terminals Operating Data Usage The EM-K-10 ramp module converts step changes in input signals to ramped signals for smooth transition from one operating level to another. Ramping time can be adjusted from virtually instantaneous response to 5 seconds for full range. Extended ramp times can be obtained with additional external capacitors. See specifications and curves for details. When used with an EM-D-30 servo amplifier, the ramp module provides a means of controlling speed in positioning systems, acceleration and deceleration in speed control systems, and the rate of pressure change in pressure control systems. Design The EM-K-10 consists of a linear circuit capable of accepting 0 to ±10V DC step input voltage levels. Two ramp rate potentiometers allow adjusted ramp rates between 0.03 and 0.5 seconds per volt output change. Extended ramp rates up to 25 sec/v output change can be obtained by the addition of external mylar or similar quality capacitors with a 50 volt or higher rating. The ramp rate potentiometers are selected externally by the use of a simple diode steering circuit or contact closures. In addition to the module mounted ramp rate potentiometers, provision has been made for the addition on an infinite number of externally located ramp rate potentiometers. Vickers, Incorporated 1997 All Rights Reserved

Specifications Input voltage Input impedance Output voltage Output load impedance Output current 10V to +10V DC 51k Ohms 10V to +10V DC 5k Ohm minimum 2 ma maximum Ramp rate adjustment 0.03 to 0.5 sec/v output change (with external capacitors) Independent ramp rate adjustments Two potentiometers on module Input/output relationship ±1% maximum input voltage Extended ramp rates Up to 25 sec/v output change (with external capacitors) Multiple ramp rates Terminal available for external connection of additional potentiometers and relays Ambient temperature range 0 to 50 C (32 to 122 F) Mass (weight) 0,45 kg (1 lb) Extended Ramp Ranges Ramp rates can be extended beyond 2 MFD by adding external capacitors between terminals 1 and 2. The chart shows recommended total capacitance values. Subtract 2MFD from reading to obtain external capacitor value. Capacitors should be mylar or similar quality with 50V or higher rating. 100 Recommended range TOTAL CAPACITANCE VALUE MFD 10 Maximum potentiometer setting (fastest time) Internal capacitor only (2 MFD) 5% potentiometer setting (slowest time) 1 0,01 0,1 1 10 100 RAMP RATE sec/v 7

Application Circuit Examples Output Single Ramp Rate Circuit Positive and negative input signals are ramped up and down at one rate. Rate is adjustable by ramp rate no. 1 potentiometer. Input EM-K-10 External capacitor (optional) Common Ramp module contacts EMRS-A-11 or EMP-A-20 power supply unit terminals Dual Ramp Rate Circuit with Diode Steering Logic A positive-going input signal is ramped up at a rate adjusted by ramp rate no. 1 potentiometer. D-1 D-2 Input EM-K-10 Output External capacitor (optional) A negative-going input signal is ramped down at a rate adjusted by ramp rate no. 2 potentiometer. Common Ramp module contacts (For D-1 or D-2 diodes, use Motorola or General Instrument IN 4003 or similar) EMRS-A-11 or EMP-A-20 power supply unit terminals Internal and External Ramp Adjustments with Relay Logic 1CR energized: A positive- or negative-going input signal is ramped up or down at a rate adjusted by ramp rate no. 1 potentiometer. 2CR energized: A positive- or negative-going input signal is ramped up or down at a rate adjusted by ramp rate no. 2 potentiometer. 4CR 3CR R2 R1 P2 P1 2CR 1CR Input 4CR 3CR EM-K-10 Output External capacitor (optional) 3CR energized: A positive- or negative-going input signal is ramped up or down at a rate adjusted by P1 potentiometer. 4CR energized: A positive- or negative-going input signal is ramped up or down at a rate adjusted by P2 potentiometer. P1 and P2 potentiometers: 10,000 ohm, 1 / 2 watt (each) R1 and R2 resistors: 470 ohm, 1 / 2 watt (each) Common Ramp module contacts EMRS-A-11 or EMP-A-20 power supply unit terminals Any number of ramp rates may be obtained by adding additional resistor or potentiometer combinations. Vickers, Incorporated 1997 All Rights Reserved

Performance Example The following example charts performance of the EM-K-10 with ramp rate potentiometers no. 1 and no. 2 connected with diodes as shown on page 8. Ramp rate potentiometer no. 1 is set at 5% (0.5 sec/v). Potentiometer no. 2 is set at 55% (0.1 sec/v). Ramp time = Ramp rate x Volts change First ramp time = 0.5 sec/v x 10 volts = 5 seconds Second ramp time = 0.1 sec/v x 15 volts = 1.5 seconds Third ramp time = 0.5 sec/v x 5 volts = 2.5 seconds INPUT volts OUTPUT volts 10 5 0 5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 10 5 0 TIME seconds 5 sec 1.5 sec 2.5 sec Ramp 1 Ramp 2 Ramp 1 5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 TIME seconds Installation Dimensions millimeters (inches) RAMP 1 RAMP 2 3,0 (0.12) Minimum clearance 1C AMP 88,9 (3.5) 1C AMP 2 MFD CAP. 9,5 (0.37) A S 9,6 (0.38) 3,0 (0.12) 62,7 (2.47) 76,2 (3.00) 10,0 (0.39) 9

EM-J-10 Programmer Module Circuit and Connections EM-J-10 500 K1 500 K2 500 K3 500 K4 500 K5 K1 K2 K3 K4 K5 R1 10K R2 10K R3 10K R4 10K R5 10K +14V DC Programmer module contacts EMRS-A-11 or EMP-A-20 power supply unit terminals Operating Data Usage The EM-J-10 programmer module provides up to five preset command signals. When used with an EM-D-30 servo amplifier, the module provides a means of presetting and selecting a variety of positions, speeds, or forces in closed loop servo systems. This module must be installed in either a single-card EMRS-A-11 or four-card EMP-A-20 power supply unit. Design The programmer module contains five potentiometers, five DC reed relays in dual inline packages, pilot lights for each relay, and an internal power source for the relays. A relay is energized when one side of its coil is connected to ground externally by means of a switch or contact closure. The potentiometer associated with the relay is then connected to the output terminal and sets the output signal level. Only one command signal at a time can be delivered by the module, even if two or more relays are energized simultaneously. Vickers, Incorporated 1997 All Rights Reserved

Specifications Relays 12V, dual inline, reed type Relay coil current 28 ma Supply voltage +20V DC nominal Relay contact maximum rating 500 ma, 100V Potentiometer type 10k Ohms, 22 turns Potentiometer resistance element Connected in parallel Potentiometers wipers Connected in series Ambient temperature range 0 to 50 C (32 to 122 F) Mass (weight) 0,45 kg (1 lb) Application Circuit Example Servo Control with Five Preset Positions This circuit controls an SM4 servovalve and uses an EM-J-10 programmer module along with an EM-D-30 servo amplifier, EMP-A-20 power supply unit, and a feedback transducer. Customer-furnished contacts EM-J-10 EMP-A-20 Feedback transducer 12V +12V Feedback signal SM4 Command output signal EM-D-30 Closed Open 1 2 3 4 5 6 11

Installation Dimensions millimeters (inches) 9,5 (0.375) 21,6 (0.85) D11 D10 D5 127,0 (5.0) D9 D4 D8 D3 D7 D2 D6 D1 31,8 (1.25) 88,9 (3.5) 3,0 (0.12) Minimum clearance Vickers, Incorporated 1997 All Rights Reserved

EMRS-A-11 Power Supply Unit Circuit and Connections EMRS-A-11 JA module receptacle Dither TB2 115V AC 60 Hz input TB1 Ø N G MDL fuse 26.8V AC 1A current transformer T1 AC D1 (1 amp) + Common AC C1 C2 C1 and C2 3600µF. 40V U1 U2 C4 C3 C6 C5 TB3 +19V 19V Common 12V +12V Operating Data Usage The EMRS-A-11 power supply unit is designed for use with Vickers electronic control modules in single axis electrohydraulic control systems. Design The power supply unit provides the means for mounting one module, supplying it with the proper excitation voltages, and connecting it to external circuit components through a terminal strip. In addition, a highly regulated ±12V DC power supply circuit is included for excitation of command and feedback circuit components. A separate terminal strip is provided for connections to this circuit. 13

Specifications Input TB1 Input voltage (no load) Input frequency Circuit protection Main Supply TB2 Output voltage (no load) Output current per leg Maximum ripple 115V AC 60 Hz 3AG 1 / 4 amp slow blow fuse on input power line ±19V DC 0.6A DC Line regulation (10% line change) 10% 0.5V peak to peak Load regulation (0 to 0.06A output current change) 18% Required Supply TB3 Output voltage ±12V DC, ±0.12V DC Output current per leg 150 ma Short circuit current leg 1.3 amps Balance 0.24V Line regulation (±10% line change) 0.03V Load regulation (0 to 0.15A output current change) 0.05V Temperature regulation 0.25V change over full range Temperature coefficient 2mV/ C Warm-up drift (after 30 minutes) 0.12V General Ambient temperature range 0 to 65 C (32 to 149 F) Mass (weight) 1,14 kg (2.5 lbs) Vickers, Incorporated 1997 All Rights Reserved

Installation Dimensions millimeters (inches) 6,3 (0.25) 5,56 thru (0.219) 100,1 (3.94) 177,8 (7.00) 165,1 (6.50) 139,7 (5.50) 152,4 (6.00) 6,3 (0.25) 9,5 (0.37) Minimum clearance 15

EMP-A-20 Power Supply Unit Circuit and Connections EMP-A-20 TB1-B TB1-A EC-B EC-A 115V AC 50 or 60 Hz input Jumpers For use with 230V AC source, remove jumper from TB3 terminals 32 and 35. Disconnect jumper from terminal 34 and connect to terminal 35. TB3 MDL 1 fuse 26.8V AC 1A current transformer Filter and rectifier Voltage regulator TB2 +20V 20V Common +12V 12V +20V 20V EC-D EC-C Typical 4 places TB1-D TB1-C Customer connections to be made with AWG No. 14 to No. 22 wire. Bare wire ends or spade lugs may be used. Terminal screw size: No. 632 x 6,3mm (0.25 in) long. Operating Data Usage The EMP-A-20 power supply unit is designed for use with Vickers electronic control modules in single and multiple axis electrohydraulic control systems. Specifications Design The power supply unit provides the means for mounting up to four modules (two EM-D-30 amplifiers, one EM-K-10 ramp module and one EM-J-10 programmer module). The unit supplies each with the proper excitation voltages, Input Input voltages (no load) 115/230V AC ±10% Input frequencies 50 or 60 Hz Circuit protection 1A time-delay fuse on input power line Main Output to Amplifier Output voltage (no load) ±20V DC Output current total 2.5A DC Maximum ripple 0.6V RMS Line regulation (10% line change) 12% Load regulation (0 to 2.5A output current change) 12% and connects it to external circuit components through a terminal strip. In addition, a highly regulated ±12V DC power supply circuit is included for excitation of command and feedback circuit components. Vickers, Incorporated 1997 All Rights Reserved

Specifications (continued) Regulated Output to Command/Feedback Circuits (includes current limiting and thermal shutdown protection) Output voltage ±12V DC,±0.6V DC Output current per leg 200 ma Line regulation ( ±10% line change) 0.05V Load regulation (0 to 40mA output current change) 0.03V Temperature coefficient 2mV/ C Warm-up drift (after 30 minutes) 0.03V General Ambient temperature range 0 to 65 C (32 to 149 F) Mass (weight) 4,1 kg (9 lbs) Installation Dimensions millimeters (inches) 8,0 (0.31) 5,9 thru (0.234) 99,7 (8.25) 225,6 (8.88) 209,6 (8.25) 260,3 (10.25) 273,0 (10.75) 6,3 (0.25) 9,6 (0.38) Minimum clearance 17

EEA-PAM-591 Amplifiers Circuit and Connections EEA-PAM-591-A-10 +15V 50 ma 15V 50 ma Gnd DC/DC Green PWR LED + +24V Gnd Integrator Reset Yellow ERR LED Alarm output Input command ±10V A Ratio B S1-2 ±10V Feedback input Auxiliary input 420 ma ±10V S1-1 249 Auxiliary input 420 ma B A Input bias + Tracking error TP1 + + Input amp S2-1 S2-2 S2-3 S2-4 S2-5 S2-6 S1-3 A B Gain + + + I Gain P Gain D P.I.D. Compensation + *Jumper removed in EEA-PAM-591-T-10 J2-2 J2-1* Gain + Pre-amp + + Pre-Amp/Current Limit Dither Freq. Current + limit JP1 Current + limit C Amplitude Current driver Current output + Output bias Current return B A 50 ma B 100 ma C 200 ma P.I.D. output monitor point Pre-amp output monitor point 1 A TP2 GND Control Input Current Output EEA-PAM-591-T-10 Inner Valve Loop Daughterboard B14 Valve feedback B16 J2-2 TP3 From motherboard B A Bias + TP4 + Ratio D D gain P P gain B A J2-1 To motherboard Vickers, Incorporated 1997 All Rights Reserved

Operating Data Usage The EEA-PAM-591-*-10 universal servovalve amplifier cards are designed to drive Vickers SM4, SX4, and SP4 servovalves as well as other industry standard servovalves, such as Moog, Atchley, Pegasus, and Rexroth in open and closed loop servo systems. This package offers flexible circuitry in a standard rack mount format requiring a single +24V DC power supply. The EEA-PAM-591-A-10 is for use with 2-stage servovalves, while the EEA-PAM-591-T-10 can control 3-stage servovalves accepting DC inner loop feedback. By selecting the appropriate onboard switches, the circuitry can be easily configured for use in position, force, and velocity applications. Design These amplifier cards can accept both voltage and current control signals, independently invert them, and generate drive currents up to ±200 ma. Improved servo system performance can be achieved by utilizing the independently adjustable proportional, derivative, and integral gain networks. In addition, a jumper-selectable output current range has been included for multiple output resolution settings. Features and Benefits Single +24V DC power supply. Standard DIN 41612 F48 interface. Accepts voltage or current control signals. Adjustable command and feedback signal ratio. Switch-selectable control signal inversion. Independently adjustable P.I.D. networks. Independent P.D. compensation for inner loop feedback (591-T only). External integrator reset input. Switch-selectable gain ranges for derivative and integral. Adjustable frequency and amplitude dither signal. Adjustable tracking alarm with opto-coupled output. Jumper-selectable output current ranges (±50, 100, or 200 ma). Front panel LEDs, test points, and adjustments for quick, easy setup and diagnostics. Specifications Power requirements: Nominal +24V DC 500 ma (at 200 ma load) +20 to +32V DC Range (amplifier shuts down below +20V DC) Maximum ripple ±5% peak, reverse polarity protected ±15V DC 50 ma Output voltages Ripple 50 mv peak to peak (pins B2 and Z2) 15V DC not short circuit protected Command signal inputs: Voltage input Range ±10V DC (pin B6, B8, or Z6) Impedance 100k ohms Current input Range 0 to 20 ma (pins Z6 and Z8) Impedance 249 ohms Output current drive (jumper selectable): Jumper JP1 in position A ±50 ma Jumper JP1 in position B ±100 ma Jumper JP1 in position C ±200 ma 19

Specifications (continued) Front panel test points: Tracking error monitor (TP1) Output current monitor Edge connector monitor points: P.I.D. output monitor (pin B18) Pre-amp output monitor (pin Z26) Input bias Output bias Current limiters Dither: Amplitude Frequency Proportional gain Integral gain: Low range High range Derivative gain: Low range High range Pre-amp driver gain Drift over operating temperature range Operating temperature range Storage temperature range EEA-PAM-591-T-10 Additional Data Valve loop P gain Valve loop D gain ±10V DC full scale, short circuit protected 1 mv/ma, short circuit protected ±10V DC at 5 ma ±6V DC at 2 ma 0 to ±10V DC 0 to 12% of full scale output 0 to ±full scale output current 0 to 20% of full scale output current 50 to 400 Hz 0.1 to 20 V/V 0 to 40 V/V-sec 2 to 300 V/V-sec 0.05 to 0.2 V-sec/V 0.3 to 2 V-sec/V 1 to 15 V/V ±0.03% of full scale output at maximum gain 0 to 50 C (32 to 120 F) 25 to 85 C (15 to 185 F) 0.1 to 5.5 V/V 0.05 to 0.2 V-sec/V Valve loop bias 0 to ±10V Valve loop feedback 0 to ±10V or 4 to 20 ma Vickers, Incorporated 1997 All Rights Reserved

Installation Dimensions millimeters (inches) EEA-PAM-591-A-10 40,3 (1.59) PWR ERR S3 1 2 3 4 5 6 S2 1 2 3 4 5 6 S1 1 C1 2 C3 3 1 OPEN OPEN C2 P12 JP1 TRACKING ERR GAIN CURRENT +LIMIT CURRENT LIMIT P GAIN 128,4 (5.06) 122,4 (4.82) I GAIN D GAIN RATIO DITHER 100,0 (3.94) INPUT BIAS OUTPUT BIAS TP1 TP2 TEST POINTS 160,0 (6.30) 13,97 (0.55) 2,5 (0.10) EEA-PAM-591-T-10 40,3 (1.59) PWR ERR S3 1 2 3 4 5 6 S2 1 2 3 4 5 6 S1 1 C1 2 C3 3 1 OPEN OPEN C2 P12 JP1 TRACKING ERR GAIN CURR +LIM CURR LIM P GAIN VALVE LOOP P GAIN 128,4 (5.06) 122,4 (4.82) I GAIN D GAIN D GAIN BIAS RATIO RATIO DITHER INPUT BIAS OUTPUT BIAS B S4 A 1 2 3 100,0 (3.94) TP1 TP2 TP3 TP4 TEST POINTS 160,0 (6.30) 13,97 (0.55) 2,5 (0.10) 21

EEA Accessory Products Cardholder Complying with DIN 41612 This cardholder (part number 02-104808) has a female connector type D32 and is designed for EEA cards with a standard DIN 41612 F48 interface. It can be permanently mounted and has screw terminals to ensure quick and secure wiring connections. When a card is inserted in the cardholder, a clip locks it in place. Female Connector Complying with DIN 41612 This female connector (part number 508178) is a type 32 and mates with certain EEA cards. It is used when electronic cards are housed in a 19-inch rack and is fitted with connection pins for soldering. Installation Dimensions millimeters (inches) Cardholder 144,5 (5.7) 15,0 (0.6) 15,0 (0.6) 130,0 (5.1) 120,0 (4.7) 5,5 thru (0.2) 45,5 (1.8) Female Connector 96 (3.74) 85 (3.35) 7 (0.28) 56,0 (2.2) 29 (1.15) 3 (0.12) 7,5 (0.29) 10,5 (0.41) 10 (0.39) 90 (3.54) 3,0 thru (0.12) 15 (0.59) 5,5 (0.22) 5,5 (0.22) Vickers, Incorporated 1997 All Rights Reserved

SMC 20H Two-Axis Hydraulic Position Controller Operating Data The SMC 20H is capable of controlling two simultaneous axes of motion using any combination of magnetostrictive or encoder position feedback devices. Data is entered using a hand-held terminal with a four-line liquid crystal display. The terminal cord has a standard 9-pin connector that plugs into the controller s front panel. Motion programs can be executed directly or from a memory that holds up to 1050 profiles. Features and Benefits Simple menus (similar to bank ATMs) allow easy programming in English. Self contained power supply eliminates customer expense and extra wiring. Plug-in boards permit use with a variety of position sensors and eliminate the need for extra conditioning boards. The SMC 20H is capable of driving ±10V DC and ±50 ma devices simultaneously without modification. Front panel layout Power Supply Module (115V AC, 230V AC, and 24V DC models available) Power Input Connections Axis 1 Analog Connections Isolated DC Supply Connections 115VAC POWER SUPPLY Processor Module AXIS DO+ 01 DO 02 AGND 03 SO 04 AGND 05 IN1+ 06 IN1 IPX AGND ENX IN2+ SEL1 IN2 SEL2 AGND SEL4 N/C SEL8 N/C XRUN IOUT+ I1 IOUT I2 AGND I3 AXIS COM COM ENBL CPU ISOL V+ V+ COM AXIS COM A X I S X [1] A X I S Y [2] MAGNETO STRICTIVE Position Sensor Module (Three models available) Axis 1 Position Sensor Connections Input/Output LED Indicators Axis 2 Position Sensor Connections Input/Output Connections Common Systems Connections The unit s dual processor design permits high speed position tracking at speeds up to 100 IPS at resolutions of 0.0001. Permanent storage for up to 1050 programs eliminates the need for additional storage. The SMC 20H s PID control algorithm, with programmable dither, dual gain breaks, and direction sensitive gains for cylinders, makes it ideal for electric and hydraulic motion control applications, including rotary and linear positioning. Power ON Indicator LED s Incoming Power Fuse Axis 2 Connections ISOL PWR +5V +15V 15V DO+ DO AGND SO AGND IN1+ IN1 AGND IN2+ IN2 AGND N/C N/C IOUT+ IOUT AGND AXIS 07 08 09 010 011 012 IPY ENY SEL1 SEL2 SEL4 SEL8 YRUN I4 I5 I6 COMM R S2 3 2 R S4 2 2 / 4 8 5 RS232 Communications Port RS422/485 Communications Port (for control pad) Communications Module 23

Specifications Processor Type Input/Output Analog voltage outputs Analog current output Digital input/output Type Current sourcing capability Current sinking capability Electrical sensors Serial Interface Protocols and connections Ports Speed: RS232C Hand-held terminal Settings Environmental Conditions Temperature (operating and storage) Relative humidity Electrical noise immunity Vibration Shock Mass (weight) Interface motion 80C188 with 64K RAM and 64K FLASH memory, TMS320C26 with 32K PROM and 2.0K RAM ±10V DC single ended each axis ±10V DC differential each axis ±50 ma each axis standard ±10V DC differential each axis Logic TRUE high or low 5 ma (max.) at 5V DC 24 ma with external supply 2 ma Power supply voltages 115/230V AC, 47 to 63 Hz, 2A (Optional +24V DC, 2A) Standard ASCII RS232C and RS422/485 300 to 38.4K Baud 9600 Baud 8 data bits, 2 stop bits, no parity 0 to 50 C (32 to 122 F) 10 to 90%, non-condensing NEMA 1cs 2.23 Surge per ANSI C-37.90A and IEEE472 5W transmitter at 1 ft, 27 to 450 MHz Electrostatic discharge 15,000 volts to ground 5 to 10 Hz, 0.2, peak to peak displacement, 10 to 200 Hz at 1G peak, MIL STD 810C 15G peak, 10 milliseconds 3,18 kg (7 lbs) Vickers, Incorporated 1997 All Rights Reserved

Typical Two-Axis Connector Wiring Axis 1 (X) 01 User V+ Lamp IPX ENX SEL1 SEL2 SEL4 SEL8 Thumbwheel PLC To Axis 1 Position Sensor Connection Servovalve OUT + OUT RUNX I4 I5 Limit + Limit User V+ V+ Cylinder Load Position Sensor Axis 2 (Y) DO+ DO AGND 07 User V+ Lamp Amplifier IPX ENX SEL1 SEL2 SEL4 SEL8 Thumbwheel PLC To Axis 2 Position Sensor Connection Proportional Valve RUNY I4 I5 Limit + Limit User V+ V+ Position Sensor Cylinder ÇÇÇÇÇ Load 25

Model Code 1 2 3 4 5 6 1 2 Model series SMC20H Two-axis hydraulic position controller Terminal P Hand-held terminal N None 3 I/O (input/output) L08 Low TRUE, DC, 8 in and 8 out per axis H08 High TRUE, DC, 8 in and 8 out per axis 4 5 Analog current 24 ±24 milliamps 50 ±50 milliamps 100 ±100 milliamps Feedback sensors E2 Two incremental encoder sensor channels M2 Two magnetostrictive sensor channels EM One incremental encoder sensor channel and one magnetostrictive sensor channel 6 Power input 115 90V to 125V AC, 50 or 60 Hz 230 200V to 240V AC, 50 or 60 Hz 24 24V DC, ±5% Vickers, Incorporated 1997 All Rights Reserved

Installation Dimensions millimeters (inches) 21,8 (0.85) 87,6 (3.45) 44,4 (1.75) 7,7 (0.30) 203,2 (8.00) Mount vertically with keyhole slot at top only. Use four No. 10 screws. 323,8 (12.75) 339,2 (13.35) 7,7 (0.30) 21,8 (0.85) 44,4 (1.75) 27

Eaton Hydraulics 15151 Highway 5 Eden Prairie, MN 55344 Telephone: 612 937-7254 Fax: 612 937-7130 www.eatonhydraulics.com 46 New Lane, Havant Hampshire PO9 2NB England Telephone: (44) 170-548-6451 Fax: (44) 170-548-7110 Form No. 00-000 Copyright Eaton Corporation, 0000 All rights reserved. Printed in U.S.A Eaton Hydraulics, Incorporated 2000 All Rights Reserved