Electromagnetic radiation exposure: assessment against ACA mandated limits



Similar documents
Electromagnetic radiation exposure: assessment against ACA mandated limits

HUMAN EXPOSURE TO EMR: ASSESSMENT OF AMATEUR RADIO STATIONS FOR COMPLIANCE WITH ACA REQUIREMENTS

VK3UM Electro Magnetic Radiation Calculator. Table of Contents

Human Exposure to Radiofrequency Electromagnetic Radiation

VK3UM Electro-magnetic Radiation Calculator. Table of Contents

This Antenna Basics reference guide includes basic information about antenna types, how antennas work, gain, and some installation examples.

Antenna Basic Concepts

FREQUENCY ASSIGNMENT REQUIREMENTS FOR THE LAND MOBILE SERVICE

Antenna Glossary Before we talk about specific antennas, there are a few common terms that must be defined and explained:

How To Understand The Kv3Um Electro Magnetic Radiation

Guidelines on the assessment of installations against electromagnetic radiation (EMR) exposure limits

SERVICES BROCHURE info@t-r-s.com.au PO BOX 680, Claremont, 6910, Western Australia

Antenna Trainer EAN. Technical Teaching Equipment INTRODUCTION

EE302 Lesson 14: Antennas

is the power reference: Specifically, power in db is represented by the following equation, where P0 P db = 10 log 10

SITE RADIATION SURVEY

5. ANTENNA TYPES. Figure 5. The vertical dipole and its electromagnetic equivalent, the vertical monopole

Selecting Receiving Antennas for Radio Tracking

COMMUNICATIONS AND MULTIMEDIA ACT 1998 NOTIFICATION OF ISSUANCE OF CLASS ASSIGNMENTS

Exposure to Radio Waves near Mobile Phone Base Stations

Antenna Properties and their impact on Wireless System Performance. Dr. Steven R. Best. Cushcraft Corporation 48 Perimeter Road Manchester, NH 03013

Antenna Deployment Technical Brief

Human Exposure Limits

Avaya WLAN 9100 External Antennas for use with the WAO-9122 Access Point

Clean, Green and Safe Management System

You will need the following pieces of equipment to complete this experiment:

MANAGEMENT OF BI-DIRECTIONAL AMPLIFIERS IN THE LAND MOBILE SERVICE IN THE FREQUENCY RANGE 29.7 MHz TO 520 MHz

Antennas 101 The Basics. Ward Silver NØAX

Mobile Phones: Jargon Explained

RADIATION PATTERNS. The half-power (-3 db) beamwidth is a measure of the directivity of the antenna.

Isolation between antennas of IMT base stations in the land mobile service

Measurements of radiofrequency fields from a WEL Networks Smart Meter

The Salzburg Model: A Precautionary Strategy for Siting of Base Stations

Electronic Communications Committee (ECC) within the Conference of Postal and Telecommunications Administrations (CEPT)

Rec. ITU-R F RECOMMENDATION ITU-R F *

Pillbox Antenna for 5.6 GHz Band Dragoslav Dobričić, YU1AW

RICHARD T ELL ASSOCIATES,INC.

sources in our environment i.e. Natural and man-made. The sun, earth and ionosphere are the natural source.

EMR COMPLIANCE HOW TO ENSURE YOUR NATA ACCREDITED CONTRACTOR IS ABLE TO PROVIDE A NATA ENDORSED REPORT

Interference to Hearing Aids by Digital Mobile Telephones Operating in the 1800 MHz Band.

REPORT ITU-R BO Broadcasting-satellite service earth station antenna pattern measurements and related analyses

AN INTRODUCTION TO TELEMETRY PART 1: TELEMETRY BASICS

Understanding Range for RF Devices

Troubleshooting Problems Affecting Radio Frequency Communication

$1 SRD Antennas. Keywords. Introduction. Overview. By P. M. Evjen. PCB antenna design Body-worn and handheld antennas. Antenna theory Small antennas

Part I: Wireless System Characteristics

Radio Frequency Exposure Test Report

Introduction to RF Engineering. Andrew CLEGG

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

IJMIE Volume 2, Issue 5 ISSN:

Omni Antenna vs. Directional Antenna

Characteristics of terrestrial IMT-Advanced systems for frequency sharing/ interference analyses

RWANDA UTILITIES REGULATORY AGENCY P.O BOX 7289 KIGALI,

Product Safety and RF Exposure for Mobile Two-Way Radios Installed in Vehicles or as Fixed Site Control Stations

Application for Digital Radio Multiplex Transmitter apparatus licence(s) Form R058 (In accordance with section 99 of the Radiocommunications Act 1992)

Technician Licensing Class

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules

COMMUNICATIONS AND MULTIMEDIA ACT 1998 CLASS ASSIGNMENTS NO. 1 OF 2015

SHARING BETWEEN TERRESTRIAL FLIGHT TELEPHONE SYSTEM (TFTS) AND RADIO ASTRONOMY IN THE 1.6 GHz BAND. Paris, May 1992

RECOMMENDATION ITU-R M (Question ITU-R 88/8)

Flexible PCB Antenna with Cable Integration Application Note Version 2

An Introduction to Microwave Radio Link Design

GSM Base Station Radiation Level: A Case Study of University of Nigeria Environment

Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands)

RF EXPOSURE LIMITS AND TESTING REQUIREMENTS

Printed Dipole Array Fed with Parallel Stripline for Ku-band Applications

The W5JCK Guide to the Mathematic Equations Required for the Amateur Extra Class Exam

Antenna Patterns and Their Meaning

Minimum requirements for DVB-T receiving antennas for portable indoor and portable outdoor reception

Correlation between OATS, Fully Anechoic Room and GTEM Radiated Emissions

MEASUREMENT AND ANALYSIS OF RF EME LEVELS FROM MOBILE TELEPHONE BASE STATIONS LOCATED AT LEICHHARDT, NSW

Selected Radio Frequency Exposure Limits

Radio Physics for Wireless Devices and Networking. The Radio Physics of WiFi. By Ron Vigneri

Technical limits of Human Exposure to RF from Cellular Base Stations and Handsets

MICROWAVE ANTENNA PATTERN WITH DIFFERENT PARAMETER EVALUATION IN MOBILE ENVIRONMENT

Cellular Wireless Antennas

Measurement of Antenna Radiation Patterns Laboratory Manual

SmartDiagnostics Application Note Wireless Interference

VARIATION TO LICENCE AREA PLAN

DVB-T and Wireless Microphone Exclusion Area Computation Through Interference Analysis

Design Note DN004. Folded Dipole Antenna for CC25xx By Audun Andersen. Keywords. 1 Introduction CC2500 CC2550 CC2510 CC2511

Communications COMMUNICATIONS (TELEPORT FACILITY LICENCE) REGULATIONS 2006

Users Manual FA106 / FA306 version 1.0. Field Analyzer. FA106 and FA306. Users Manual

CHAPTER 4. Electromagnetic Spectrum

Cisco Aironet Antennas and Accessories

OpenWay Radio Frequency FAQ

Coaxial Cable Feeder Influence on Yagi Antenna Dragoslav Dobričić, YU1AW

Mobile use, radio signals and health

RF safety at base station sites

Applications in EMC testing. Outline. Antennas for EMC Testing. Terminology

Antennas & Transmission Lines

Cisco Aironet Antennas and Accessories

GSM frequency planning

Wireless Power for Remote Monitoring Applications

TRAPEZE NETWORKS EXTERNAL ANTENNA OPTIONS

Drones Jammer. A simple drone Jammer designed to hack unwelcomed civilian drones within your backyard range.

CABLES CABLES. Application note. Link Budget

ELECTROMAGNETIC ENERGY Evaluation and Management for Antenna Sites

PCB Antenna with Cable Integration Application Note Version 2

Transcription:

Electromagnetic radiation exposure: assessment against ACA mandated limits General radio services (operating above 0 MHz) (Edition May 0) Disclaimer Unless otherwise specified, the information contained in these guidelines is intended as a guide only and should not be relied upon as legal or technical advice or regarded as a substitute for legal or technical advice in individual cases. Opinions contained in these guidelines do not necessarily reflect the opinions of ACMA. It is recommended that independent specialist advice be sought before relying upon the information contained in these guidelines.

Introduction This information booklet has been prepared to enable licensees and/or operators of radiocommunications services not covered by a service specific booklet to make a simple assessment of their facilities against electromagnetic radiation (EMR) exposure limits mandated by the Australian Communications Authority (ACA). The charts contained within allow a determination of the distance from the antenna at which the exposure limit is met. There is no obligation on licensees to use this booklet and other theoretical assessment methods are acceptable to the ACA provided they can be traced back to the equations given in Appendix B of AS 77. Radiofrequency radiation: principles and methods of measurement 00 khz to 0 GHz. This booklet covers transmitters operating above 0 MHz. Applicable Conditions These charts assume a single antenna (fed by any number of transmitters) no interference from adjacent transmitting antennas no reflections from significant metal structures in front of the antenna. If these conditions do not apply detailed analysis (beyond the scope of this booklet) or physical measurement is required. Near-field correction Close to an antenna, in what is known as the near-field, the gain of the antenna may be less than the farfield gain specified by the antenna manufacturer. This effect is frequency and antenna dependent. Due to the broad frequency range that radiocommunications services operate over and the large variety of antenna types available this booklet does not provide near field correction charts. Making the assessment Three steps are required to assess a particular installation:. Ascertain antenna type. Determine EIRP. Determine the distance from the antenna at which EMR exposure limits are met. Step : Ascertain antenna type Radiocommunications installations may use use omni-directional antennas such as dipoles or directional antennas such as yagis and panels. Parabolic (dish) antennas are sometimes used as part of a service for communication between sites. This booklet does not cover this type of antenna. Instead, refer to the companion booklet on fixed links. Omni-directional antennas Monopole or stacked dipole: Energy is transmitted equally in a horizontal direction but not above or below the antenna. Directional antennas Yagi: Side view Top view Majority of energy transmitted in front of the antenna. Very small amount transmitted in other directions. Page of 9

Panel or corner reflector: Energy transmitted in front of the antenna. No significant energy transmitted to the back or sides or directly above or below the antenna. Side view Top view Step : Calculate EIRP from power and gain Before determining the safety distance from the antenna, the maximum equivalent isotropically radiated power (EIRP) must be determined. Some radiocommunications licenses may specify the EIRP. If this is the case, use that value and skip this step. Chart provides a method for determining the EIRP for an antenna from the power fed to the antenna and the antenna gain. Gain: the gain of the antenna will be provided by the antenna manufacturer. It may be expressed in either dbd or dbi. If the antenna gain is expressed in dbi, it will need to be converted to dbd for use with Chart. This is done by subtracting.5 from the dbi figure. For example, 8.5 dbi is equivalent to 6 dbd. Power: The power figure is Chart is the power, in watts (W) input to the antenna. The power can be the known transmitter output power or that specified on the radiocommunications licence. When more than one transmitter feeds the antenna, the power of all transmitters should be added together and the sum used for Chart. A range of equipment, for example combiners and filters, can cause signal loss between the transmitter and the antenna. The manufacturer of the equipment may provide a db figure for these losses. If this is the case, subtract this figure from the antenna gain. If the value of the losses is unknown the safety distance determined in step three will simply be overestimated. Use of Chart Using a straight edge, for example a ruler, draw a line between the appropriate power figure on the left and the appropriate gain figure on the right. The EIRP can be estimated from the point where the line intersects the EIRP column. For example, if power is 0 W and antenna gain dbd, the EIRP column is intersected at approximately 650 W (the actual value is 656 W). If in doubt as to the precise value, use the next highest division. Page of 9

Example use of Chart : 00 00 0 0 50 0 0 5 0.5 656 0000 0000 000 000 000 000 00 00 00 00 0 0 0 0 0.8 9 8 7 6 5 9 8 7 6 5 0 Power (W) EIRP (W) Gain (dbd) Alternatively, the gain may be calculated using the following equation: EIRP = P G where P is the power fed into the antenna and G is the linear gain of the antenna determined by the following equation: dbd+.5 G =. Page of 9

00 00 0 0 50 0 0 5 0.5 656 0000 0000 000 000 000 000 00 00 00 00 0 0 0 0 0.8 9 8 7 6 5 9 8 7 6 5 0 Power (W) EIRP (W) Gain (dbd) Chart Page 5 of 9

Step : Determining the distance from the antenna at which EMR exposure limits are met Once the EIRP of the antenna is known, the distance at which exposure limits are met can be determined. Charts and provide a method for determining this distance. The charts are broken up into two categories:. (): the area directly in front of the antenna is known as the boresight. For the purpose of the charts in this booklet, the boresight has been defined as the area ±5 both horizontally and vertically in the intended directon of radiated energy. Refer to figures.. Off axis (): the area between 5 and 90 from directly in front of the antenna both horizontally is as off-axis. Refer to figures. Panel/corner reflector side view Figure Panel/corner reflector top view Yagi side/top view Figure Page 6 of 9

Omnidirectional side view Figure Omnidirectional top view The appropriate chart(s) for determining the distance at which EMR exposure limits are met must next be selected. Figures indicate which charts may be used for various areas around the antenna. Once the appropriate chart(s) have been selected draw a horizontal line across the chart from the appropriate EIRP value until it meets the curve. From this point draw a vertical line down to the bottom of the chart to intersect the distance axis. The value at this point is the distance from the antenna at which EMR exposure limits are met. For example, if an antenna has an EIRP of 500 W, indicates the safety distance is approximately. metres in front of the antenna. is used to find the appropriate distance off-axis. For an EIRP of 500 W the EMR exposure limit is met approximately. metres above, below and to the sides of the antenna. Once the distance at which EMR exposure limits are met is determined, ensure that adequate access restrictions are put in place to ensure that members of the public cannot enter areas around the antenna where exposure limits are exceeded. Example use of : - no near-field correction 000 00 EIRP (W) 0 0 6 8 6 8 Distance (m) Page 7 of 9

- no near-field correction 000 00 EIRP (W) 0 0 6 8 6 8 Distance from antenna (m) Page 8 of 9

Off-axis - no near-field correction 000 00 EIRP (W) 0 0 5 6 7 Distance from antenna (m) Page 9 of 9