SITE RADIATION SURVEY

Size: px
Start display at page:

Download "SITE RADIATION SURVEY"

Transcription

1 SITE RADIATION SURVEY Site X, zzz Town XX XXXXXXX, XXXXXXX Site ID No: Dated:

2 CONTENTS 1.0 SCOPE EQUIPMENT TRANSMITTERS FM Antenna Details GENERAL A SUPPLEMENTARY WORK PRACTICES REFERENCES SURVEY DETAILS SITE/RADIATION DRAWINGS CAUTION SHEET

3 1.1 SITE Site Name, Owner Name Structure Height: 50m Latitude: Longitude: Type of site: FM Broadcast Microwave Link Data Link 2 Way Comms 400MHz 2 Way Comms 900MHz 1.0 SCOPE This radiation survey is limited to the structure of the mast and areas that are reasonably accessible. No attempt was made to measure the radiation IN-FRONT of radiating antennas. It is assumed that normal precautions for work on high power sites will be followed and NO work will be carried out in front of any antenna unless it has been confirmed that no significant power is being radiated from the antenna. 3

4 2.0 EQUIPMENT The radiation survey was conducted using a RAHAM model 40 meter, a RAHAM 94 E field probe S/N and a RAHAM H105 H field probe S/N H Field Probe Covers the Frequency Range 100 khz 1 GHz. The correction factors for the probe are within 2% for the frequencies involved in this survey. The E field probe covers the frequency range 200 khz 3GHz. The correction factors are less than 2% and no correction has been applied, as this is much smaller than the probes accuracy. All Equipment Calibrated by ARPANSA, 28 th August 2007 NOTE: in some cases this procedure will overestimate the measured field. 4

5 3.0 TRANSMITTERS FM Broadcast Equipment Other Services Rack 1 Comms Room RACK 2 5

6 Rack 3 Rack 4 1. Rack 6 Rack 8 6

7 Other The transmitters were confirmed as actively transmitting before and after the radiation survey. Serial Numbers are listed when clearly visible on equipment. At no time were live transmitter cabinets opened during the survey. 4.0 FM Antenna Details FM Array Model: 16U3311 RFS 904CP Panels 16 Panel Array Gain: 14dBi Feeder: 3/12 x 2 Height: 40m-50m For Other antenna Types and Locations See Tower Drawings. 7

8 5.0 MEASUREMENTS The attached drawings have the results of the radiation survey measurements on them. Sufficient readings were taken to establish the fields during the conditions when the tests were conducted. These are shown in two columns one an average or typical value and the maximum value recorded in the general area. Two tables are given, first on ladders and platforms. The second table for inside the tower/mast/mounting steelwork structure or inside the line of the legs. In some areas the readings are calculated from knowledge of the field and the measurements on similar parts of the antennas. These inferred values are enclosed in (parentheses). Anywhere where the peak reading of either the E or H field is between 1.0 mw/sq cm and 4.99 mw / sq cm, an easily identifiable area, hatched with and coloured yellow. NOTE: These areas may contain positions with areas below 2.0mW/sq cm but are intended to contain all areas which should be avoided. The maximum time allowed by ARPANSA standard in these areas is also shown on the drawings. Following exposure to these elevated levels the standard calls for a recovery period of not less than 40 minutes. This shall be spent in an area in which the field strength is substantially less than the maximum occupational levels. The standard suggests 0.5mW/sq cm would satisfy this requirement. Anywhere where the peak reading of either the E or H field is above 5.0 mw/sq cm an easily identifiable area is defined, hatched and coloured red. NOTE these areas may contain positions with levels below 1.0mw/sq cm but are intended to contain all areas, which must be avoided. In some cases no readings were taken. A large part of the structure clearly presents no possibility of radiation hazards. Other areas the levels can be determined by the radiation from different configurations of antennas and can be deduced from other attached drawings. These areas are not marked. Other areas clearly present a Radiation Hazard and readings were not taken to minimise the risks to the survey team. Typically these areas are adjacent to >5mW areas. These areas are hatched and coloured but no readings are given. 8

9 6.0 GENERAL As well as the tower the transmitter room was also surveyed. Within the transmitter area with the transmitter running at full power into the antenna all areas were less than the minimum discernible reading on the meter. ALL LEVELS WERE BELOW <0.001 mw/cm2 6.1 A SUPPLEMENTARY Evaluation of RF site utilising the ACMA s supplements 1, 2, 3, 4, 5 and 6. This evaluation utilises the charts and calculations of signal strengths from the data given by the ACMA. These figures over estimate the signal strength and if you require a more accurate survey a full-metered survey will be required. Not required as full survey conducted. 9

10 7.0 WORK PRACTICES 1) No work is to be carried out in front of radiating antennas. 2) General Public should not Enter Site under any Circumstances. 3) All GridPaks and Microwave Dishes should be assumed to be actively transmitting NO work should be carried out in front unless connected equipment has been confirmed to be DISSCONECTED. 4) All Areas 3-6m below FM Antennas are Time Limited 5) Areas 0-3m below and directly behind FM Antennas are NO GO zones 6) Before work is performed on site the EMR Folder should be read and signed. 10

11 8.0 REFERENCES WHO, 1993, Electromagnetic Fields (300Hz to 300GHz) Environmental health Criteria 137. World Health Organisation, Geneva. Standards Association of Australia, Principle exposure levelsradiofrequency radiation-300 khz to 300 GHz, Publication AS (int), Standards Association of Australia, North Sydney. Standards Association of Australia, Principles and methods of measurement-radiofrequency radiation- 300kHz to 100 GHz, publication AS , Standards Association of Australia, North Sydney. ARPANSA Radiation Protection Standard Maximum Exposure Levels to Radiofrequency Fields- 3 khz to 300 GHz (2002) 9.0 SURVEY DETAILS Survey Performed On XX_/_XX_/XXXX Report Compiled By Sample Signed XXXXXXXXX Field Service Technician Date: 25/11/2007 Report Endorsed By Sample Signed XXXXXXXXX Technical Services Manager Date: 29/11/

12 10.0 SITE/RADIATION DRAWINGS Site layout and radiation drawing. Note: If more than the structure assessed the site radiation drawings will include rooftop and building layouts. 12

13 Intentionally left Blank 13

14 SRF LOG BOOK TO BE SIGNED BY ANY PERSONS ENTERING RF HAZARD AREAS. Sheet Number:.. Transmitter Site:. I certify that I have read this Site Radiation Folder and understand the RF Hazard Areas and Safety procedures at this site. Date Name Company and /or Section Telephone No. Reason for visit signature 14

15 SRF LOG BOOK TO BE SIGNED BY ANY PERSONS ENTERING RF HAZARD AREAS. Sheet Number:.. Transmitter Site:. I certify that I have read this Site Radiation Folder and understand the RF Hazard Areas and Safety procedures at this site. Date Name Company and /or Section Telephone No. Reason for visit signature 15

16 SRF LOG BOOK TO BE SIGNED BY ANY PERSONS ENTERING RF HAZARD AREAS. Sheet Number:.. Transmitter Site:. I certify that I have read this Site Radiation Folder and understand the RF Hazard Areas and Safety procedures at this site. Date Name Company and /or Section Telephone No. Reason for visit signature 16

17 CAUTION SHEET CAUTION! This Site Radiation Folder may not accurately describe the extent of Hazardous RF Radiation at this site for the reasons indicated below. A person accredited to perform RF measurements must record the RF radiation hazard of the proposed work area or an approved calibrated personal RF monitor must be used at all times in conjunction with the RF Safe Working Procedures. (Tick) THIS SITE WAS MEASURED ON / /. And a new SRF is being prepared. And/or (Tick) Errors have been detected. An Amendment return form has been submitted and noted in the site amendment registrar. And/or (Tick) Short term rearrangements are in place as follows: They have noted in the site amendment index registrar, which is to be signed off when restored to the original state. This sheet must then be removed and discarded. And/or (Tick) Other: Please give details:.... Inserted by (Name)..Date:././.. Signature:.Contact Tel:. 17

OpenWay Radio Frequency FAQ

OpenWay Radio Frequency FAQ OpenWay Radio Frequency FAQ March 10, 2010 2010, Itron Inc. All rights reserved. 1 Overview This document provides general information about radiofrequency (RF) electromagnetic fields from OpenWay wireless

More information

Clean, Green and Safe Management System

Clean, Green and Safe Management System Clean, Green and Safe Management System SP 24-38: Working with Radio Frequency Radiation - Minimum Requirements Author : Communications Network Operations Centre Manager A. Reece Checked by: Manager Communications/

More information

EMR COMPLIANCE HOW TO ENSURE YOUR NATA ACCREDITED CONTRACTOR IS ABLE TO PROVIDE A NATA ENDORSED REPORT

EMR COMPLIANCE HOW TO ENSURE YOUR NATA ACCREDITED CONTRACTOR IS ABLE TO PROVIDE A NATA ENDORSED REPORT EMR COMPLIANCE HOW TO ENSURE YOUR NATA ACCREDITED CONTRACTOR IS ABLE TO PROVIDE A NATA ENDORSED REPORT Chris Zombolas Technical Director, EMC Technologies Pty Ltd 57 Assembly Drive Tullamarine Vic. 3043,

More information

Electromagnetic radiation exposure: assessment against ACA mandated limits

Electromagnetic radiation exposure: assessment against ACA mandated limits Electromagnetic radiation exposure: assessment against ACA mandated limits General radio services (operating above 0 MHz) (Edition May 0) Disclaimer Unless otherwise specified, the information contained

More information

NZQA registered unit standard 25268 version 3 Page 1 of 5

NZQA registered unit standard 25268 version 3 Page 1 of 5 Page 1 of 5 Title Guard against the dangers of electromagnetic radiation while working on telecommunications network structures or sites Level 4 Credits 3 Purpose This unit standard covers the fundamental

More information

Electromagnetic radiation exposure: assessment against ACA mandated limits

Electromagnetic radiation exposure: assessment against ACA mandated limits Electromagnetic radiation exposure: assessment against ACA mandated limits Paging services (Edition May 2002) Disclaimer Unless otherwise specified, the information contained in these guidelines is intended

More information

SERVICES BROCHURE +61 8 9381 7199 +61 8 9381 7166. email: info@t-r-s.com.au www.t-r-s.com.au. PO BOX 680, Claremont, 6910, Western Australia

SERVICES BROCHURE +61 8 9381 7199 +61 8 9381 7166. email: info@t-r-s.com.au www.t-r-s.com.au. PO BOX 680, Claremont, 6910, Western Australia SERVICES BROCHURE +61 8 9381 7199 +61 8 9381 7166 email: info@t-r-s.com.au www.t-r-s.com.au PO BOX 680, Claremont, 6910, Western Australia COMPANY INFORMATION Total Radiation Solutions Pty Ltd (TRS) is

More information

Working safely around Radiofrequency (RF) Transmitters

Working safely around Radiofrequency (RF) Transmitters Working safely around Radiofrequency (RF) Transmitters Exposure to excessive levels of radiofrequency (RF) emissions may affect your health This Mobile Carriers Forum (MCF) Fact sheet series is designed

More information

Human Exposure to Radiofrequency Electromagnetic Radiation

Human Exposure to Radiofrequency Electromagnetic Radiation Australia s regulator for broadcasting, the internet, radiocommunications and telecommunications www.acma.gov.au Human Exposure to Radiofrequency Electromagnetic Radiation Information for licensees of

More information

How To Understand The Kv3Um Electro Magnetic Radiation

How To Understand The Kv3Um Electro Magnetic Radiation Acknowledgements WIA Spectrum Committee Michael Owen.. SK VK3KI.. founder of the modern WIA. Phil Wait VK2ASD [President WIA]. Roger Harrison VK2ZRH [WIA Director]. Peter Young VK3MV [ex Director and ACMA].

More information

Human Exposure Limits

Human Exposure Limits Human Exposure Limits Session 3 0 Version December 2014 Learning objectives In this session we will: Learn about the international exposure limits for workers and the public Learn about methods for assessing

More information

Safe Work Practices on Radio Frequency Transmitting Apparatus

Safe Work Practices on Radio Frequency Transmitting Apparatus Frequency Transmitting Apparatus Summary: This document supports the Power System Safety Rules and its requirements assembled under Radio Frequency Transmitting Apparatus Category 8. It covers safe work

More information

VK3UM Electro Magnetic Radiation Calculator. Table of Contents

VK3UM Electro Magnetic Radiation Calculator. Table of Contents Table of Contents VK3UM EMR Calculator 2 Disclaimer 2 Background 3 Program Objectives 4 Calculations Provided 5 Screen Options 7 Circular Apertures 14 Calculation Methods 16 Examples 17 Author 19 References

More information

sources in our environment i.e. Natural and man-made. The sun, earth and ionosphere are the natural source.

sources in our environment i.e. Natural and man-made. The sun, earth and ionosphere are the natural source. Electromagnetic Radiation (EMR) consist of waves of electric and magnetic energy moving together at the speed of light and sometimes is referred as electromagnetic field (EMF) They are basically two forms

More information

Selected Radio Frequency Exposure Limits

Selected Radio Frequency Exposure Limits ENVIRONMENT, SAFETY & HEALTH DIVISION Chapter 50: Non-ionizing Radiation Selected Radio Frequency Exposure Limits Product ID: 94 Revision ID: 1736 Date published: 30 June 2015 Date effective: 30 June 2015

More information

Measurements of radiofrequency fields from a WEL Networks Smart Meter

Measurements of radiofrequency fields from a WEL Networks Smart Meter Measurements of radiofrequency fields from a WEL Networks Smart Meter Report 2012/36 This report was prepared for: WEL Networks Ltd P O Box 925 Hamilton Report prepared by: Martin Gledhill Finalised: 7

More information

Fixed Wireless Fact Sheet

Fixed Wireless Fact Sheet National Broadband Network Fixed Wireless Fact Sheet What is the National Broadband Network? The National Broadband Network (NBN) is designed to provide high speed broadband access to 100 per cent of Australian

More information

RF EXPOSURE LIMITS AND TESTING REQUIREMENTS

RF EXPOSURE LIMITS AND TESTING REQUIREMENTS RF EXPOSURE LIMITS AND TESTING REQUIREMENTS Jay Moulton Vice President March 12, 2013 1 OVERVIEW Specific Absorption Rate (SAR) and Maximum Permissible Exposure (MPE) Standards and Limits Evaluation Methods

More information

Millennium Product Inc. Model: Cell Shield / Zorb

Millennium Product Inc. Model: Cell Shield / Zorb Millennium Product Inc. Cell Shield / Zorb Prepared by PCTEST LAB Issued on: 10/22/2015 Report Version 2.6 NOTE: SAR results only apply to the device tested. Although the device may have had different

More information

MEASUREMENT AND ANALYSIS OF RF EME LEVELS FROM MOBILE TELEPHONE BASE STATIONS LOCATED AT LEICHHARDT, NSW

MEASUREMENT AND ANALYSIS OF RF EME LEVELS FROM MOBILE TELEPHONE BASE STATIONS LOCATED AT LEICHHARDT, NSW AUSTRALIAN RADIATION PROTECTION AND NUCLEAR SAFETY AGENCY A R P N S A Lower Plenty Road YALLAMBIE VIC 3085 Phone 61 3 9433 2211 Fax 61 3 9432 1835 E-mail: arpansa@health.gov.au Web: www.arpansa.gov.au

More information

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 EN 301 489-17 v1.2.1 TEST REPORT FOR 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 ISSUE DATE: JANUARY 29, 2008 Prepared for BROADCOM CORPORATION 190 MATHILDA

More information

ELECTROMAGNETIC ENERGY Evaluation and Management for Antenna Sites

ELECTROMAGNETIC ENERGY Evaluation and Management for Antenna Sites ELECTROMAGNETIC ENERGY Evaluation and Management for Antenna Sites 10/9/97 Revised 12/27/2001 The purpose of this document is to provide information to assist the reader in understanding the concepts required

More information

HUMAN EXPOSURE TO EMR: ASSESSMENT OF AMATEUR RADIO STATIONS FOR COMPLIANCE WITH ACA REQUIREMENTS

HUMAN EXPOSURE TO EMR: ASSESSMENT OF AMATEUR RADIO STATIONS FOR COMPLIANCE WITH ACA REQUIREMENTS HUMAN EXPOSURE TO EMR: ASSESSMENT OF AMATEUR RADIO STATIONS FOR COMPLIANCE WITH ACA REQUIREMENTS May 2005 Version 2.0 PO Box 78 BELCONNEN ACT 2616 Telephone (02) 6219 5555 Facsimile (02) 6219 5353 www.aca.gov.au

More information

ACRS 2.0 User Manual 1

ACRS 2.0 User Manual 1 ACRS 2.0 User Manual 1 FCC Regulatory Information This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,

More information

Electromagnetic Radiation Compatibility Survey and Safety Analysis around Mobile Base Transceiver Stations: Case Studies around Kathmandu Valley

Electromagnetic Radiation Compatibility Survey and Safety Analysis around Mobile Base Transceiver Stations: Case Studies around Kathmandu Valley Research Journal of Engineering Sciences ISSN 2278 9472 Electromagnetic Radiation Compatibility Survey and Safety Analysis around Mobile Base Transceiver Stations: Case Studies around Kathmandu Valley

More information

Radio Frequency Exposure Test Report

Radio Frequency Exposure Test Report Radio Frequency Exposure EN 62311 January 2008 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0Hz 300GHz) (IEC 62311:2007, modified)

More information

Smart meters: Compliance with radio frequency exposure standards

Smart meters: Compliance with radio frequency exposure standards Smart meters: Compliance with radio frequency exposure standards Summary Smart meters use low power radio frequency signals to collect and transmit information about use of services such as electricity,

More information

Report Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015

Report Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015 Report Of Shielding Effectiveness Test For SafeSleeve Radiation Shielding Technology Test Date(s): June 07 June 09, 2015 Issue Date: June 10, 2015 UST Project No: 15-0137 Total Number of Pages Contained

More information

RF safety at base station sites

RF safety at base station sites RF safety at base station sites CONTENTS 1 Purpose and scope................................................. 2 2 Introduction........................................................ 2 3 Basic information...................................................

More information

The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz

The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz J. Klima, R. Ščehovič Department of Physics, Faculty of Natural Sciences, University of Mathias Bel, Tajovského

More information

Release: 1. ICTTCR3192A Protect against electromagnetic radiation and system hazards when working on telecommunications radio sites

Release: 1. ICTTCR3192A Protect against electromagnetic radiation and system hazards when working on telecommunications radio sites Release: 1 ICTTCR3192A Protect against electromagnetic radiation and system hazards when working on telecommunications radio sites ICTTCR3192A Protect against electromagnetic radiation and system hazards

More information

Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands)

Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) Issue 3 June 2009 Spectrum Management and Telecommunications Radio Standards Specification Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) Aussi disponible

More information

EMR-300 Broadband RF Survey Meter

EMR-300 Broadband RF Survey Meter Electric d Magnetic Field Measurement EMR-300 Broadbd RF Survey Meter Available with Isotropic Probes to cover 3 khz to 60 GHz Easy-to-Use Design Lightweight d Rugged Cost Effective Fully Automatic Zeroing

More information

COMMUNICATIONS ALLIANCE LTD INDUSTRY CODE C564:2011 MOBILE PHONE BASE STATION DEPLOYMENT

COMMUNICATIONS ALLIANCE LTD INDUSTRY CODE C564:2011 MOBILE PHONE BASE STATION DEPLOYMENT COMMUNICATIONS ALLIANCE LTD INDUSTRY CODE C564:2011 MOBILE PHONE BASE STATION DEPLOYMENT Industry Code - Mobile Phone Base Station Deployment This Code was issued in draft form for public comment as DR

More information

Fibre Optic Solutions for your Test and Instrumentation needs

Fibre Optic Solutions for your Test and Instrumentation needs Fibre Optic Solutions for your Test and Instrumentation needs Aerospace Test EMC/EMP Military Industrial Control High Energy Physics Automotive Test Custom www.point2point.co.uk Fibre Optic Solutions for

More information

ELECTROMAGNETIC FIELDS AND PUBLIC HEALTH HEALTH AND SAFETY GUIDELINES #1

ELECTROMAGNETIC FIELDS AND PUBLIC HEALTH HEALTH AND SAFETY GUIDELINES #1 SINGAPORE, 16 AUGUST 2001 HEALTH SCIENCES AUTHORITY PRESS RELEASE ELECTROMAGNETIC FIELDS AND PUBLIC HEALTH HEALTH AND SAFETY GUIDELINES #1 THE EMF HEALTH ISSUE 1 Over the past years a large number of scientific

More information

Mobile Phones: Jargon Explained

Mobile Phones: Jargon Explained Mobile Phones: Jargon Explained 2G 3G Aerial Second Generation Mobile Phone System. See GSM See Third Generation Mobile Phone System. Device designed to radiate and receive electromagnetic energy. Antenna

More information

Radio Frequency Electromagnetic Energy (RF-EME) Compliance Report (Predictive Modeling)

Radio Frequency Electromagnetic Energy (RF-EME) Compliance Report (Predictive Modeling) Radio Frequency Electromagnetic Energy (RF-EME) Compliance Report (Predictive Modeling) Prepared for: AT&T Mobility, LLC 7655-7665 Redwood Blvd. Novato,CA 94945 USID# 118154 Site No. CNU2701 DUCKHORN DR.

More information

EMR Exposure Limits & Assessment Methods for Mobile Phone Communications. Lindsay Martin Manager, Non-Ionising Radiation Section

EMR Exposure Limits & Assessment Methods for Mobile Phone Communications. Lindsay Martin Manager, Non-Ionising Radiation Section EMR Exposure Limits & Assessment Methods for Mobile Phone Communications Lindsay Martin Manager, Non-Ionising Radiation Section Introduction How can we use Wireless Communication Safely? Wireless communication

More information

Continuous, remote monitoring and logging of electromagnetic fields

Continuous, remote monitoring and logging of electromagnetic fields MULTI-BAND EMF AREA MONITOR AMB-8057-03/G Continuous, remote monitoring and logging of electromagnetic fields Discrimination of GSM and UMTS contributions to total EMF values Electric field monitoring

More information

Appendix 1. The Existing Regulatory Scheme Comprises:

Appendix 1. The Existing Regulatory Scheme Comprises: The Existing Regulatory Scheme Comprises: A. An Act about management of the radiofrequency spectrum and other matters. The short title is Radiocommunications Act (Cth) No. 174 1992 as amended; B. An Act

More information

ETSI TR 101 870 V1.1.1 (2001-11)

ETSI TR 101 870 V1.1.1 (2001-11) TR 101 870 V1.1.1 (2001-11) Technical Report Fixed radio transmitter sites; Exposure to non-ionising electromagnetic fields; Guidelines for working conditions 2 TR 101 870 V1.1.1 (2001-11) Reference DTR/SAFETY-00004

More information

Application for Digital Radio Multiplex Transmitter apparatus licence(s) Form R058 (In accordance with section 99 of the Radiocommunications Act 1992)

Application for Digital Radio Multiplex Transmitter apparatus licence(s) Form R058 (In accordance with section 99 of the Radiocommunications Act 1992) Application for Digital Radio Multiplex Transmitter apparatus licence(s) Form R058 (In accordance with section 99 of the Radiocommunications Act 1992) Use of form and instructions This form is to be used

More information

FOR EXISTING 254-FOOT COMMUNICATIONS TOWER 16700 Skyline Drive La Habra Heights California

FOR EXISTING 254-FOOT COMMUNICATIONS TOWER 16700 Skyline Drive La Habra Heights California MASTER PLAN FOR EXISTING 254-FOOT COMMUNICATIONS TOWER 16700 Skyline Drive La Habra Heights California PROPERTY OWNER: Coast Community College District 1370 Adams Avenue Costa Mesa, CA 92626 Attn: Richard

More information

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec This value-packed VuSpec CD-ROM represents the most complete resource available for professional engineers looking for

More information

COLLATED QUESTIONS: ELECTROMAGNETIC RADIATION

COLLATED QUESTIONS: ELECTROMAGNETIC RADIATION COLLATED QUESTIONS: ELECTROMAGNETIC RADIATION 2011(2): WAVES Doppler radar can determine the speed and direction of a moving car. Pulses of extremely high frequency radio waves are sent out in a narrow

More information

Mobile use, radio signals and health

Mobile use, radio signals and health Mobile use, radio signals and health Mobile use, radio signals and health How does the mobile network work? Since the 1970s, the use of various types of radio transmitters has risen dramatically, to the

More information

SAR Test Report: Type Number FAD-3022012-BV; FCC ID PY7FD022012; IC 4170B-FD022012

SAR Test Report: Type Number FAD-3022012-BV; FCC ID PY7FD022012; IC 4170B-FD022012 1 (34) Report issued by an Accredited Laboratory Rapport utfärdad av ett ackrediterat laboratorium This laboratory is accredited to SS-EN ISO/IEC 17025 (SWEDAC accreditation no. 1761). SAR Test Report:

More information

VARIATION TO LICENCE AREA PLAN

VARIATION TO LICENCE AREA PLAN Attachment A VARIATION TO LICENCE AREA PLAN BRIDGETOWN (RADIO) May 2001 LICENCE AREA PLAN BRIDGETOWN VARIATION The Australian Broadcasting Authority hereby varies the licence area plan (LAP) for radio

More information

CELL PHONE TOWERS TOWN OF INNISFIL

CELL PHONE TOWERS TOWN OF INNISFIL CELL PHONE TOWERS TOWN OF INNISFIL Dr. Jim Pfaff, MD, BSc, MHSc, DAvMed, Associate Medical Officer of Health Marina Whelan, CPHI (C), BSc., Manager, Health Hazards Lori Holmes, CPHI (C), BASc, Coordinator,

More information

Exposures to radiofrequency fields from WiFi in New Zealand schools

Exposures to radiofrequency fields from WiFi in New Zealand schools Exposures to radiofrequency fields from WiFi in New Zealand schools Report 2014/02 This report was prepared for: Ministry of Health P O Box 5013 Wellington Report prepared by: Martin Gledhill Finalised:

More information

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise

More information

Microwave Exposure from Mobile Phones and Base Stations in Sweden

Microwave Exposure from Mobile Phones and Base Stations in Sweden Microwave Exposure from Mobile Phones and Base Stations in Sweden Prof. Dr. Yngve Hamnerius and Thomas Uddmar Chalmers University of Technology, Department of Electromagnetics, SE 41 96 Goteborg, Sweden,

More information

How To Know If You Are Safe To Use An Antenna (Wired) Or Wireless (Wireless)

How To Know If You Are Safe To Use An Antenna (Wired) Or Wireless (Wireless) 1 2 The range of RF spans 3 KHz (3000 Hz) to 300 GHz (300 million Hz) Frequencies of RF devices range from the low frequency AM broadcasts (80 MHz) to higher frequency mobile phones (1900 MHz) smart meters

More information

RF Exposure Evaluation Report

RF Exposure Evaluation Report RF Exposure Evaluation Report APPLICANT EQUIPMENT BRAND NAME MODEL NAME FCC ID FILING TYPE : TomTom International BV : GPS Navigation System : TomTom : 4CR51 : S4L4CR51 : Certification STANDARD : OET Bulletin

More information

This document is available at HTTP://WWW.FALCOM.DE/. FAL-ANT-1. GSM/DCS/GPS antenna (with Fakra-SMB connectors) Description. Version 1.

This document is available at HTTP://WWW.FALCOM.DE/. FAL-ANT-1. GSM/DCS/GPS antenna (with Fakra-SMB connectors) Description. Version 1. This document is available at HTTP://WWW.FALCOM.DE/. FAL-ANT-1 GSM/DCS/GPS antenna (with Fakra-SMB connectors) Description Version 1.00 Contents 0 INTRODUCTION...3 0.1 GENERAL... 3 1 SECURITY...4 1.1 GENERAL...

More information

What are radio signals?

What are radio signals? Mobile phones and other wireless technologies have become an integral part of everyday life. But does using a mobile phone regularly, or living near a base station, have any implications for our health?

More information

5.8GHz Audio/Video Sender

5.8GHz Audio/Video Sender 5.8GHz Audio/Video Sender RF-Link / Araneus USA Inc. 44845 Industrial Dr. Fremont, CA. 94538 U.S.A. Tel: +1-510-4135885~5886 Fax: +1-510-6515995 URL: http://www.rflinkusa.com Design and specification subject

More information

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module Engineering Test Report No. 37802-02 Rev. A Measurement of RF Emissions from a Final Coat Electronics Corrosion Module For : Canadian Auto Preservation, Inc. 390 Bradwick Drive Concord, Ontario CANADA

More information

Advanced Measurements of Microwave Oven Leakage

Advanced Measurements of Microwave Oven Leakage Conference paper Advanced Measurements of Microwave Oven Leakage M. Bangay [1] C. Zombolas [2] 1. Australian Radiation Protection and Nuclear Safety Agency 2. EMC Technologies Pty Ltd Abstract Reports

More information

LRS - Application Form PRESIDENT OF THE OFFICE OF ELECTRONIC COMMUNICATIONS

LRS - Application Form PRESIDENT OF THE OFFICE OF ELECTRONIC COMMUNICATIONS Date...... LRS (company's stamp) ref. sign:... PRESIDENT OF THE OFFICE OF ELECTRONIC COMMUNICATIONS Issue No.: The application concerns the station: APPLICATION for a license on usage of radio devices

More information

VK3UM Electro-magnetic Radiation Calculator. Table of Contents

VK3UM Electro-magnetic Radiation Calculator. Table of Contents Table of Contents Disclaimer 2 Background 3 Glossary of terms 4 Program Objectives 5 Calculations provided 6 Screen Options 8 Safe Elevation Angle 18 Australian Level 1 and Level 2 requirements 21 Screen

More information

QUALITY MANUAL. DOCUMENT PURPOSE This Quality Manual is to provide reference material to staff and to assist with NATA AS/NZS ISO/IEC 17020 2012

QUALITY MANUAL. DOCUMENT PURPOSE This Quality Manual is to provide reference material to staff and to assist with NATA AS/NZS ISO/IEC 17020 2012 DOCUMENT PURPOSE This Quality Manual is to provide reference material to staff and to assist with NATA AS/NZS ISO/IEC 17020 2012 QUALITY MANUAL WF-EME-QM-001 Document Control Issue Number Description of

More information

Spectrum and Power Measurements Using the E6474A Wireless Network Optimization Platform

Spectrum and Power Measurements Using the E6474A Wireless Network Optimization Platform Application Note Spectrum and Power Measurements Using the E6474A Wireless Network Optimization Platform By: Richard Komar Introduction With the rapid development of wireless technologies, it has become

More information

SAR ASSOCIATED WITH THE USE OF HANDS-FREE MOBILE TELEPHONES

SAR ASSOCIATED WITH THE USE OF HANDS-FREE MOBILE TELEPHONES SAR ASSOCIATED WITH THE USE OF HANDS-FREE MOBILE TELEPHONES S.J. Porter, M.H. Capstick, F. Faraci, I.D. Flintoft and A.C. Marvin Department of Electronics, University of York Heslington, York, YO10 5DD,

More information

This Antenna Basics reference guide includes basic information about antenna types, how antennas work, gain, and some installation examples.

This Antenna Basics reference guide includes basic information about antenna types, how antennas work, gain, and some installation examples. Antenna Basics This Antenna Basics reference guide includes basic information about antenna types, how antennas work, gain, and some installation examples. What Do Antennas Do? Antennas transmit radio

More information

What the experts say: The consensus of scientific opinion

What the experts say: The consensus of scientific opinion What the experts say: The consensus of scientific opinion AMTA relies on the expert judgment of independent public health authorities, such as the World Health Organization, for assessments of safety and

More information

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT For SAMBO HI TECH CO., LTD. 616-15, GANSUK4-DONG, NAMDONG-GU, INCHUN 405-810, KOREA Model: LSR700, SCI545HV1EF, SCI545HVEF This Report Concerns: Original

More information

CMP30. User Manual. www.audac.eu

CMP30. User Manual. www.audac.eu CMP30 User Manual www.audac.eu 2 Index Introduction 4 Precautions 5 Safety requirements 5 Caution servicing 5 EC Declaration of Conformity 5 Waste of Electrical and Electronic Equipment (WEEE) 6 Caution

More information

Agilent 8753ET/8753ES Network Analyzers

Agilent 8753ET/8753ES Network Analyzers Agilent 8753ET/8753ES Network Analyzers 8753ET, 300 khz to 3 or 6 GHz 8753ES, 30 khz to 3 or 6 GHz Configuration Guide System configuration summary The following summary lists the main components required

More information

Radio waves and health. Mobile communications

Radio waves and health. Mobile communications Radio waves and health Mobile communications Mobile communications and health Mobile telephony Radio communications have been used for more than a hundred years in various sorts of applications. Already

More information

Antenna Trainer EAN. www.edibon.com. Technical Teaching Equipment INTRODUCTION

Antenna Trainer EAN. www.edibon.com. Technical Teaching Equipment INTRODUCTION Antenna Trainer EAN Technical Teaching Equipment Products Products range Units 3.-Communications INTRODUCTION Antennas are the main element of aerial communications. They are the transition between a transmission

More information

P/N 135A-970-022 FAA Approved: 12/6/2007 Section 9 Initial Release Page 1 of 8

P/N 135A-970-022 FAA Approved: 12/6/2007 Section 9 Initial Release Page 1 of 8 FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT FOR GARMIN SL40 NAV/COMM Serial No: Registration No: When the GARMIN SL40 COM radio is installed in the Liberty Aerospace XL-2, this supplement is applicable

More information

Dual Chamber Temporary External Pacemaker

Dual Chamber Temporary External Pacemaker 5392 Dual Chamber Temporary External Pacemaker Electromagnetic Compatibility Declaration Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. The following list includes

More information

CHAPTER 6. Precision Approach Systems

CHAPTER 6. Precision Approach Systems ELEC4504 Avionics Systems 77 CHAPTER 6. Precision Approach Systems 6.1. Introduction The word approach is used to describe the phase of flight which immediately precedes the landing. While the approach

More information

Annex to the joint statement: Exposure of the general public to radiofrequency fields

Annex to the joint statement: Exposure of the general public to radiofrequency fields 16 November 2009 Annex to the joint statement: Exposure of the general public to radiofrequency fields 1. Introduction This document presents typical exposure of the general public to radiofrequency (RF)

More information

DSA800 Series Spectrum Analyzer

DSA800 Series Spectrum Analyzer DSA800 Series Spectrum Analyzer Configuration Guide This guide is used to help users to configure DSA800 series spectrum analyzer according to their requirements. You can get an overall understanding of

More information

GSM Base Station Radiation Level: A Case Study of University of Nigeria Environment

GSM Base Station Radiation Level: A Case Study of University of Nigeria Environment INTERNATIONAL JOURNAL OF SCIENTIFIC & TECHNOLOGY RESEARCH VOLUME 1, ISSUE 8, SEPTEMBER 212 ISSN 2277-8616 GSM Base Station Radiation Level: A Case Study of University of Nigeria Environment Mamilus. A.

More information

Automated Meter Reading Frequently Asked Questions. What is AMR?

Automated Meter Reading Frequently Asked Questions. What is AMR? Automated Meter Reading Frequently Asked Questions What is AMR? AMR stands for Automated Meter Reading. It is a method of using advanced communications technology to read meters remotely. It reduces human

More information

Cellular Antenna Proposal Form

Cellular Antenna Proposal Form Cellular Antenna Proposal Form Islands Trust, Northern Office 700 North Road, Gabriola Island, BC V0R 1X3 Phone: 250-247-2063 Fax: 250-247-7514 www.islandstrust.bc.ca northinfo@islandstrust.bc.ca Be sure

More information

EMR IN THE COMMUNITY - MANAGING THE INVISIBLE

EMR IN THE COMMUNITY - MANAGING THE INVISIBLE EMR IN THE COMMUNITY - MANAGING THE INVISIBLE Barbara Phi, FuturePace Solutions, Australia futurepace@bigpond.com Chris Zombolas, EMC Technologies Pty Ltd, Melbourne Australia, chris@emctech.com.au Abstract

More information

LTE: Technology and Health. 4G and Mobile Broadband

LTE: Technology and Health. 4G and Mobile Broadband LTE: Technology and Health 4G and Mobile Broadband LTE Technology and Health Mobile Broadband typically refers to providing customers with high speed data while on the move. There are several technologies

More information

RF Exposure and Modular Equipment. Considerations

RF Exposure and Modular Equipment. Considerations RF Exposure and Modular Equipment Considerations RF Exposure Rules SAR and MPE Estimation Summary Based on current interpretations of US radio law by FCC Based upon the TCB Exclusion List and various interpretations

More information

Keywords Mobile Tower Radiations, Electromagnetic Radiations, Signal Strength, Mobile Phone

Keywords Mobile Tower Radiations, Electromagnetic Radiations, Signal Strength, Mobile Phone Volume 5, Issue 1, January 2015 ISSN: 2277 128X International Journal of Advanced Research in Computer Science and Software Engineering Research Paper Available online at: www.ijarcsse.com Analysis of

More information

Model Rules for License-Exempt White Space Devices

Model Rules for License-Exempt White Space Devices Model Rules for License-Exempt White Space Devices 1 Permissible Frequencies of Operation. (a) White space devices ( WSDs ) are permitted to operate on a license-exempt basis subject to the interference

More information

Cisco Aironet 5-dBi Omnidirectional Antenna (AIR-ANT2450V-N)

Cisco Aironet 5-dBi Omnidirectional Antenna (AIR-ANT2450V-N) Cisco Aironet 5-dBi Omnidirectional Antenna (AIR-ANT2450V-N) This document describes the Cisco Aironet AIR-ANT2450V-N 5-dBi Omnidirectional Antenna and provides instructions for mounting it. The antenna

More information

Wireless Test Licence

Wireless Test Licence RESPONSE TO CONSULTATION REPORT ONCONSULTATION Application Form Wireless Test Licence Document No: 05/35a Date: 23 June 2005 An Coimisiún um Rialáil Cumarsáide Commission for Communications Regulation

More information

Design and Certification of ASH Radio Systems for Japan

Design and Certification of ASH Radio Systems for Japan Design and Certification of ASH Radio Systems for Japan RFM s second-generation ASH radio hybrids are being used in a wide variety of applications in Japan, operating under the Japanese BIJAKU radio regulations.

More information

MPC STAFF REPORT WIRELESS TELECOMMUNCATIONS FACILITY February 19, 2013 MPC FILE NO. 12-002102-PLAN

MPC STAFF REPORT WIRELESS TELECOMMUNCATIONS FACILITY February 19, 2013 MPC FILE NO. 12-002102-PLAN MPC STAFF REPORT WIRELESS TELECOMMUNCATIONS FACILITY MPC FILE NO. 12-002102-PLAN WTF SUMMARY Report Status MPC Project Planner Petitioner, Property Owner, Agent Information Initial Report Jack Butler,

More information

Users Manual FA106 / FA306 version 1.0. Field Analyzer. FA106 and FA306. Users Manual

Users Manual FA106 / FA306 version 1.0. Field Analyzer. FA106 and FA306. Users Manual Field Analyzer FA106 and FA306 Users Manual 1 Contents Contents...2 Preface...3 Chapter 1 Basic Functions...4 1.1 Turning on/off...4 1.2 Choosing the required measuring mode...4 1.3 Picture of front panel...5

More information

Critical Product Information: VodeOX EMR Protection

Critical Product Information: VodeOX EMR Protection Critical Product Information: VodeOX EMR Protection New Improved EMR Protection for Cellphones, Tablets, ipads, Laptops, and any Electronic Screen/Monitor. Protect yourself from potentially harmful ElectroMagnetic

More information

GPS Fleet Setup Manual. Created by the team at FollowUs. A short documentation to get you started and setup with regards to the GPS Fleet

GPS Fleet Setup Manual. Created by the team at FollowUs. A short documentation to get you started and setup with regards to the GPS Fleet GPS Fleet Setup Manual Created by the team at FollowUs A short documentation to get you started and setup with regards to the GPS Fleet 8/2/2010 CE RoHS compliant A UK product 2 Important please read:-

More information

1 Multi-channel frequency division multiplex frequency modulation (FDM-FM) emissions

1 Multi-channel frequency division multiplex frequency modulation (FDM-FM) emissions Rec. ITU-R SM.853-1 1 RECOMMENDATION ITU-R SM.853-1 NECESSARY BANDWIDTH (Question ITU-R 77/1) Rec. ITU-R SM.853-1 (1992-1997) The ITU Radiocommunication Assembly, considering a) that the concept of necessary

More information

Remarkable achievements

Remarkable achievements Remarkable achievements 149.2 km link over water providing 8E1 throughput with 99,99% annual availability Radio link transmitting data from 25km height in Stratosphere to 149km ground station Largest MW

More information

FOR MORE INFORMATION. 125 8880 or from a non-telstra phone 13 2200 and say pre-paid telstra.com/ppmbb visit a telstra store or partner

FOR MORE INFORMATION. 125 8880 or from a non-telstra phone 13 2200 and say pre-paid telstra.com/ppmbb visit a telstra store or partner FOR MORE INFORMATION 125 8880 or from a non-telstra phone 13 2200 and say pre-paid telstra.com/ppmbb visit a telstra store or partner getting to know your telstra pre-paid 4G WI-FI (760S) LET S GET THIS

More information

Hear The Future...Now! SIEM-2T/SIEM-2R

Hear The Future...Now! SIEM-2T/SIEM-2R Hear The Future...Now! SIEM-2T/SIEM-2R UHF PLL Mono In Ear Monitoring System 856 59508-03 ATTENTION Please pay high attention to the following information. The guideline published by Occupational Safety

More information

DVB-T Television Repeater Jim Andrews, KH6HTV

DVB-T Television Repeater Jim Andrews, KH6HTV AN-23 DTV Rptr.doc (6/1/2015) p. 1 of 5 Application Note AN-23 June, 2015 DVB-T Television Repeater Jim Andrews, KH6HTV Fig. 1 A 70cm, Digital TV Repeater, block diagram. The FCC allows licensed amateur

More information

FREQUENCY ASSIGNMENT REQUIREMENTS FOR THE LAND MOBILE SERVICE

FREQUENCY ASSIGNMENT REQUIREMENTS FOR THE LAND MOBILE SERVICE RALI : LM 8 DATE OF EFFECT : 23/09/2015 Radiocommunications Assignment and Licensing Instruction FREQUENCY ASSIGNMENT REQUIREMENTS FOR THE LAND MOBILE SERVICE AUSTRALIAN COMMUNICATIONS AND MEDIA AUTHORITY

More information