RWANDA UTILITIES REGULATORY AGENCY P.O BOX 7289 KIGALI,
|
|
|
- Calvin Austin
- 10 years ago
- Views:
Transcription
1 REPUBLIC OF RWANDA RWANDA UTILITIES REGULATORY AGENCY P.O BOX 7289 KIGALI, Tel: , Fax: Website: GUIDELINES FOR LIMITING HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS UP TO 300 GHz June 2009
2 1. INTRODUCTION Purposes and scope of the guidelines General principles Basic restrictions Reference levels MAXIMUM EXPOSURE LIMITS The basic limits which shall not be exceeded Safety Factor RF and Microwave Exposed Workers (Including Occupationally Exposed Persons) Field Strength Limits Simultaneous exposure Basic Restrictions - Specific Absorption Rate (SAR) Limits Induced and Contact Current Limits Peak Field Strength Limit for Pulsed Fields Exposure of Persons Not classified as RF and Microwave Exposed Workers (Including the General Public) Field Strength Limits Simultaneous exposure Basic Restrictions - Specific Absorption Rate (SAR) Limits Induced and Contact Current Limits Free standing individual Object contact Peak Field Strength Limit for Pulsed Fields Guidelines relating to power frequency exposures (50Hz) Reference levels SITING AND INSTALLATION OF RF DEVICES Basic Principles Field levels Exposure and induced current General Recommendations Warning signs Fences Site with multiple source exposure Unnecessary metal near an RF transmitter Medical Devices and Electromagnetic Interference Radar and Communications Systems Antenna beam Restriction to site area SAFETY PROCEDURES Safety for operators and maintenance personnel (RF Workers) Awareness Safety during maintenance Procedures and maintenance manuals
3 Components replacement Testing RF Load during testing Protection of the General Public Exposure level Warning signs Sites with leakage WARNING SIGNS Design of the Recommended Warning Signs Area Demarcation Warning sign Danger Sign Example of warning signs PROTECTIVE MEASURES Controls Engineering control Administrative control APPENDICES Appendix I. Theoretical Estimation of Exposure Fields A. Near-Field and Far-Field Zones B. Practical Examples Calculation of Minimum Distance Where Exposures Fall within the Limits Exposure at the ground level Safety at base station sites Appendix II. Terms and definitions References
4 Abbreviations and acronyms: EIRP Equivalent Isotropically Radiated Power EMC Electromagnetic Compatibility EMF Electromagnetic Field ICNIRP International Commission on Non-Ionizing Radiation Protection ITU International Telecommunication Union RF Radio Frequency RURA Rwanda Utilities Regulatory Agency SA Specific Absorption SAR Specific Absorption Rate WHO World Health Organization 4
5 1. I TRODUCTIO The development in the electronics industry have led to the wide use of radiofrequency (RF) devices in various areas, including telecommunications, radio and television broadcasting, radar, industry etc. Studies of possible hazards to human health from exposure to RF electromagnetic fields show that there is a need for control. Many nations as well as International organizations have formulated guidelines establishing limits for occupational and general public exposure to Electromagnetic Fields (EMF). Exposures above limits given in these guidelines may cause adverse health effects. The type and extent of effects depends on the strength of the field, exposure duration, frequency and other factors such as polarization and distance from the source. Rwanda Utilities Regulatory Agency (RURA) authorizes devices, transmitters and facilities that generate RF and microwave radiation. Human exposure to RF radiation emitted by these transmitters is one of several factors that must be considered. The approach of RURA in developing these guidelines is mainly based on ICNIRP Guidelines, The ITU-T Recommendation K.52, and some World Health Organization (WHO) publications. The ITU-T Recommendation K.52 aims to help with compliance of telecommunication installations with safety limits for human exposure to electromagnetic fields produced by telecommunications equipment in the frequency range 9 khz to 300 GHz. This Recommendation provides techniques and procedures for assessing the severity of field exposure and for limiting the exposure to occupationally exposed and the general public to these fields if the limits are exceeded. WHO publications give practical guidance for personnel working at base station and antenna sites on how to take exposure to radiofrequency electromagnetic fields into account in order to make sure applicable exposure guidelines are not exceeded. The publications are primarily directed at RF workers but some contents are relevant to other workers, such as, rooftop workers who may have reasons to come close to transmitting equipment. 1.1 Purposes and scope of the guidelines The main objective of this publication is to establish guidelines for limiting EMF exposure that will provide protection against known adverse health effects, that is: To specify maximum levels and durations of exposure to Electromagnetic fields of frequencies up to 300 GHz in order to prevent human health effects; 5
6 To specify maximum allowable RF contact and induced body currents to prevent the physical perception of electromagnetic fields to the general public and shock or burns to EMF exposed workers; To recommend general procedures for ensuring that exposure of the general public and of personnel working in the vicinity of RF and microwave devices is not greater than the levels specified in the guidelines; and To recommend working conditions that will lead to high standards of safety for all personnel engaged in the operation and maintenance of RF devices. 1.2 General principles Basic restrictions The basic restrictions address the fundamental quantities that determine the physiological response of the human body to electromagnetic fields. Basic restrictions apply to a situation with the body present in the field. The basic limits for human exposure are expressed as the Specific Absorption Rate (SAR), Specific Absorption (SA) and Current Density. Protection against adverse health effects requires that these basic restrictions are not exceeded. However, these mandatory basic restrictions are specified as quantities that are often impractical to measure Reference levels The reference level (magnetic field, induced limb currents and contact currents) which are quantities that are more practical to measure are provided as an alternative means showing the compliance with the basic restrictions which are impractical to measure. Compliance with all reference levels given in these guidelines will ensure compliance with basic restrictions. If measured values are higher than reference levels, it does not necessarily follow that the basic restrictions have been exceeded, but a more detailed analysis is necessary to assess compliance with the basic restrictions. It is important to emphasize that exposure limits are not emission limits; they apply to locations accessible to workers or members of the general public. Thus, it is possible to achieve compliance by limiting access to areas where the field limits are exceeded. 6
7 2. MAXIMUM EXPOSURE LIMITS 2.1 The basic limits which shall not be exceeded These limits are given in terms of the currents in the body, either by induction or contact with energized metallic objects, or in terms of the rate at which RF electromagnetic energy is absorbed in the body. The latter is expressed, more precisely, as the specific absorption rate (SAR), i.e., the rate of RF energy absorption per unit mass in the body. SAR has units of joules per second per kilogram or watts per kilogram (W/kg). In practice, direct measurements of SAR are feasible only under laboratory conditions. Recommended maximum exposure levels in terms of unperturbed electric and magnetic field strength as well as power density are therefore given in addition to the SAR limits. These maximum field intensities are at levels which would generate a SAR or induced body current no greater than the basic limit. 2.2 Safety Factor For exposure limits of RF and microwave exposed workers, a safety factor of approximately 10 was incorporated with reference to the scientific-consensus threshold for adverse health effects. For other persons including the general public, an additional safety factor (2 to 5) was included to arrive at lower limits. The incorporation of these safety factors is to provide for all possible conditions under which the exposure might occur. The rationale for lower general public limits is as follows: Exposure to the public is potentially 24 hours a day for 7 days a week, compared with 8 hours a day, 5 days a week for RF and microwave exposed workers. Certain members of the general public may be more susceptible to harm from RF and microwave exposure. To determine whether the maximum exposure levels and durations are exceeded, full consideration shall be given to such factors as: 1. Occupancy of areas; 2. Actual duration of exposure and time averaging (including ON/OFF times of the RF generators, direction of the beam, duty factors, sweep times, etc.); 3. Spatial characteristics of exposure, i.e., whole body or parts thereof; 4. Uniformity of the exposure field, i.e., spatial averaging. In certain instances and over a specific frequency range, higher exposure levels are permitted for short durations. If this is the case, the field strengths and power densities should be averaged over 6 minutes period. 7
8 2.3. RF and Microwave Exposed Workers (Including Occupationally Exposed Persons) Field Strength Limits An RF and microwave exposed worker shall not be exposed to electromagnetic radiation in a frequency band listed in Column 1 of Table 1 if the field strength exceeds the value given in Column 2 or 3 of Table 1, when averaged spatially and over time, or if the power density exceeds the value given in Column 4 of Table 1, when averaged spatially and over time. The spatial averaging is carried out over an area equivalent to the vertical cross-section of the human body (projected area). A time-averaging period of 6 minutes should be employed for frequencies up to 10 GHz. For frequencies exceeding 10 GHz, the averaging time is 68/f 1.05 minutes (f in GHz). Table1. Reference levels for occupational exposure to time-varying electric and magnetic fields (unperturbed rms values) Frequency range Electric field strength (V/m) Magnetic field strength (A/m) Up to 1 Hz Hz /f Hz /f khz 500/f 20/f khz MHz /f 1-10 MHz 610/f 1.6/f MHz MHz 3f 1/ f 1/2 f/ GHz Equivalent plane wave power density S (W/m 2 ) Seq NOTE 1 f is as indicated in the frequency range column. NOTE 2 For frequencies between 100 khz and 10 GHz, the averaging time is 6 minutes. NOTE 3 For frequencies up to 100 khz, the peak values can be obtained by multiplying the rms value by 2( 1.414). For pulses of duration tp, the equivalent frequency to apply should be calculated as f = 1/(2tp). 8
9 NOTE 4 For frequencies exceeding 10 MHz, it is suggested that the peak equivalent planewave power density, as averaged over the pulse width, does not exceed 1000 times the Seq limit, or that the field strength does not exceed the field strength exposure levels given in the table. NOTE 5 For frequencies exceeding 10 GHz, the averaging time is 68/f 1.05 minutes (f in GHz). NOTE 6 - A power density of 10 W/m 2 is equivalent to 1 mw/cm 2. NOTE 7 - A magnetic field strength of 1 A/m corresponds to microtesla (µt) or milligauss (mg) Simultaneous exposure For simultaneous exposure to fields at different frequencies, the compliance with the exposure limits is evaluated using the equations below. All conditions for the appropriate frequency ranges are to be satisfied. 1 MHz E E i + 10 MHz i= 1 khz l, i i> 1 MHz Ei a 1 where: 1 MHz H H j + 10 MHz j= 1 khz l, j j> 1 MHz H b j 1 Ei is the electric field strength at frequency i El, i is the reference limit at frequency i Hj is the magnetic field strength at frequency j Hl, j is the reference limit at frequency j a = 610 V/m for occupational exposure and 87 V/m for general public exposure b = 24.4 A/m for occupational exposure and 5 A/m for general public exposure 1 MHz Ei c GHz E E i= 100 khz i> 1 MHz l, i + i 2 1 where: 1 MHz H d j GHz H H j= 100 khz j> 1 MHz l, j + j 2 1 9
10 Ei is the electric field strength at frequency i El, i is the reference limit at frequency i Hj is the magnetic field strength at frequency j Hl, j is the reference limit at frequency j c = 610/f V/m (f in MHz) for occupational exposure and 87/f 1/2 V/m for general public exposure d = 1.6/f A/m (f in MHz) for occupational exposure and 0.73/f for general public exposure Basic Restrictions - Specific Absorption Rate (SAR) Limits SAR is a measure of the rate at which electromagnetic energy is absorbed in the body. At frequencies between 100 khz and 10 GHz, SAR limits take precedence over field strength and power density limits and shall not be exceeded. The SAR should be determined for cases where exposures take place at 0.2 m or less from the source. For conditions where SAR determination is impractical, field strength or power density measurements shall be carried out. In cases where SAR determination is appropriate, the values in Table 2 shall not be exceeded: Table2. SAR Limits for RF and Microwave Exposed Workers Frequency range Whole-body average SAR (W/kg) Localized SAR (head and trunk) (W/kg) 100 khz-10 GHz NOTE 1 All SAR values are to be averaged over any 6-minute period. Localized SAR (limbs) (W/kg) NOTE 2 The localized SAR averaging mass is any 10 g of contiguous tissue; the maximum SAR so obtained should be the value used for the estimation of exposure. 10
11 2.3.4 Induced and Contact Current Limits Free standing exposed workers For free standing RF and microwave exposed workers (no contact with metallic objects), current induced in the human body by electromagnetic radiation shall not exceed the value given in Table 3. Table3. Induced and Contact Current Limits for RF and Microwave Exposed Workers Reference ence levels for time varying contact currents from conductive objects Frequency range Up to 2.5 khz khz 0.4f 100 KHz 110 MHz 40 Maximum contact current (ma) Reference levels for current induced in any limb at frequencies between10 and 110MHz. (ma) 100 f is the frequency in khz Contact current at 110 MHz and below Up to 110 MHz, which includes the FM radio transmission frequency band, reference levels for contact current are given above which caution must be exercised to avoid shock and burn hazards. The point contact reference levels are presented in Table 3. For the frequency range MHz, reference levels are provided for limb currents that are below the basic restrictions on localized SAR Object Contact No object with which an RF and microwave exposed worker may come into contact by hand grip shall be energized by electromagnetic radiation to such an extent that the current flow through an electrical circuit, having an impedance equivalent to that of the human body, exceeds the value given in Table Simultaneous exposure In situations of simultaneous exposure to fields of different frequencies, these exposures are additive in their effects. Additivity should be examined separately for the effects of thermal and electrical stimulation, and the basic restrictions should be met. The equation given in section applies. 11
12 2.3.5 Peak Field Strength Limit for Pulsed Fields For exposures to pulsed electromagnetic fields in the frequency range of 0.1 to MHz, the peak value of the instantaneous field (temporal peak), in terms of electric field strength, shall not exceed 100 kv/m Exposure of Persons Not classified as RF and Microwave Exposed Workers (Including the General Public) Field Strength Limits A person other than an RF and microwave exposed worker shall not be exposed to electromagnetic radiation in a frequency band listed in Column 1 of Table 4, if the field strength exceeds the value given in Column 2 or 3 of Table 4, when averaged spatially and over time, or if the power density exceeds the value given in Column 4 of Table 4, when averaged spatially and over time. The spatial averaging is carried out over an area equivalent to the vertical cross-section of the human body (projected area). Table 4. Exposure Limits for Persons Not classified As RF and Microwave Exposed Workers (Including the General Public) Frequency range Electric field strength (V/m) Magnetic field strength (A/m) Up to 1 Hz Hz /f Hz /f khz 250/f 4/f khz 250/f khz MHz /f 1-10 MHz 87/f 1/2 0.73/f MHz MHz 1.375f 1/ f 1/2 f/ GHz NOTE 1 f is as indicated in the frequency range column. Equivalent plane wave power density S (W/m 2 ) NOTE 2 For frequencies between 100 khz and 10 GHz, the averaging time is 6 Seq 12
13 minutes. NOTE 3 For frequencies up to 100 khz, the peak values can be obtained by multiplying the rms value by 2( 1.414). For pulses of duration tp, the equivalent frequency to apply should be calculated as f = 1/(2tp). NOTE 4 For frequencies exceeding 10 MHz, it is suggested that the peak equivalent plane-wave power density, as averaged over the pulse width, does not exceed 1000 times the Seq limit, or that the field strength does not exceed the field strength exposure levels given in the table. NOTE 5 For frequencies exceeding 10 GHz, the averaging time is 68/f 1.05 minutes (f in GHz). NOTE 6 - A power density of 10 W/m 2 is equivalent to 1 mw/cm 2. NOTE 7 - A magnetic field strength of 1 A/m corresponds to micro tesla (µt) or milli gauss (mg) Simultaneous exposure In situations of simultaneous exposure to fields of different frequencies, these exposures are additive in their effects. Additivity should be examined separately for the effects of thermal and electrical stimulation, and the basic restrictions should be met. The equation given in section applies Basic Restrictions - Specific Absorption Rate (SAR) Limits SAR is a measure of the rate at which electromagnetic energy is absorbed in the body. At frequencies between 100 khz and 10 GHz, SAR limits take precedence over field strength and power density limits and shall not be exceeded. The SAR should be determined for cases where exposures take place at 0.2 m or less from the source. For conditions where SAR determination is impractical, field strength or power density measurements shall be carried out. In cases where SAR determination is appropriate, the values in Table 5 shall not be exceeded: Table 5. SAR Limits for the General Public Localized Whole-body Localized SAR (head Frequency range average SAR SAR (limbs) and trunk) (W/kg) (W/kg) (W/kg) 100 khz-10 GHz
14 NOTE 1 All SAR values are to be averaged over any 6-minute period. NOTE 2 The localized SAR averaging mass is any 10 g of contiguous tissue; the maximum SAR so obtained should be the value used for the estimation of exposure Induced and Contact Current Limits Free standing individual For free standing individuals (no contact with metallic objects), current induced in the human body by electromagnetic radiation shall not exceed the value given in Table Object contact No object, with which a person may come into contact by hand grip, shall be energized by electromagnetic radiation to such an extent that the current flow through an electrical circuit, having an impedance equivalent to that of the human body, exceeds the value given in Table 6. Table 6. Induced and Contact Current Limits for Persons Not classified as RF and Microwave Exposed E Workers (Including the General Public) Reference levels for time varying contact currents from conductive objects Frequency range Up to 2.5 khz khz 0.2f 100 KHz 110 MHz 20 f is the frequency in khz Maximum contact current (ma) Reference levels for current induced in any limb at frequencies between10 and 110MHz. (ma) Peak Field Strength Limit for Pulsed Fields For exposures to pulsed electromagnetic fields in the frequency range of 0.1 to MHz, the peak value of the instantaneous field (temporal peak), in terms of electric field strength, shall not exceed 100 kv/m. 14
15 2.5 Guidelines relating to power frequency exposures (50Hz) Reference levels The levels of exposure corresponding to the reference levels to determine if the basic restrictions are likely to be exceeded, in the frequency range (f) going from 25 Hz to 800 Hz (or khz) are the following ones: For the intensity of Electric Field (E): 250/f or 5 kv/m for the general public for the frequency 50 Hz, 500/f or 10 kv/m for the workers for the frequency 50 Hz, For the intensity of Magnetic Field (H): 4/f or 80 A/m for the general public for the frequency 50 Hz, 20/f or 400 A/m for the workers for the frequency 50 Hz, For Magnetic Induction (B): 5/f or 100 µt for the general public for the frequency 50Hz, 25/f or 500 µt for the workers for the frequency 50 Hz, These values are expressed in root mean square values. 3. SITI G A D I STALLATIO OF RF DEVICES 3.1 Basic Principles In order to establish protective measures in areas where RF devices are used, it is necessary to take into account the time workers may spend in these areas. The following must be taken into consideration when surveying around RF devices: Field levels The field levels must be known in controlled areas where restricted occupancy is allowed. These areas shall be designated accordingly, and the maximum worker occupancy time shall be posted where applicable, Exposure and induced current The exposure as well as induced and contact currents in uncontrolled areas shall not exceed the limits specified in Section
16 3.2 General Recommendations Warning signs Warning signs specified in Section 5.1, or suitable substitutes, indicating the presence of RF fields, shall be posted according to recommendations of Section Fences The areas surrounding unmanned, high-power sources of RF radiation shall be fenced off to prevent unauthorized access to places where an overexposure could occur. If a metallic fence is used, the contact current limits specified in Tables 3 and 6 shall be met Site with multiple source exposure The siting of an RF device shall take into account the practical possibility of multiple source exposures from fields and leakage from other devices in the vicinity Unnecessary metal near an RF transmitter Metallic objects that are not necessary shall not be present near any radiating RF device, as they may cause high intensity fields in some locations. 3.3 Medical Devices and Electromagnetic Interference Electromagnetic interference from devices such as shortwave diathermy and electrosurgical units may cause malfunctions, with potentially adverse consequences, to various medical devices, such as electrocardiographs, electromyographs, electroencephalographs, cardiac pacemakers, etc. Other sources of interference are radio, television and radar transmissions as well as mobile communications devices (e.g., cellular telephones, walkie-talkies and vehicle mounted transceivers). Electromagnetic interference can generally be eliminated by means of shielding, filtering or grounding of the spurious signals, or relocating the devices being affected. 3.4 Radar and Communications Systems Antenna beam Wherever possible, the antenna beam shall be directed away from occupied areas. However, if the beam does irradiate occupied areas, the applicable maximum exposure limits given in Section 2 shall be observed. If needed, antenna sweep restrictions or RF power reduction may be employed to prevent the exposure limits from being exceeded in occupied locations. 16
17 3.4.2 Restriction to site area For any installation that is to be operated, all signs and barriers demarcating areas of restricted or denied occupancy and all interlock systems shall be permanently installed to prevent accidental access to the zone of denied occupancy. 4. SAFETY PROCEDURES 4.1 Safety for operators and maintenance personnel (RF Workers) Awareness Maintenance personnel and operators of RF devices shall be aware of the potential hazards of RF fields Safety during maintenance Switching On and Off of the RF Device Particular care shall be taken to ensure that all people are clear of any direct beam of an RF device before it is switched on for test or maintenance purposes Procedures and maintenance manuals Instructions and procedures for repair, maintenance and operation of a device, as specified by the manufacturer or a competent person, shall be readily available to, and be followed by, operators and maintenance personnel Components replacement Replacement components shall be equivalent to original components. Transmission lines, waveguides, gaskets, flanges and similar components shall have the same operating characteristics as the original components or be approved by the manufacturer of the original equipment, or a person trained in the safe use of this equipment Testing Testing of a device (waveguides and other components that have been replaced in their designated locations) either before or after completion of any repair work shall be carried out after protective shields. 17
18 RF Load during testing An RF generating component shall be tested with an appropriate load connected to its output or with the radiated energy absorbed by anechoic material. The energy generated shall not be allowed to radiate freely into occupied areas. 4.2 Protection of the General Public Exposure level Except under special circumstances, members of the general public shall not be allowed access to areas where levels exceed those specified in Section Warning signs Where access is possible, warning signs shall be posted at the entrance to any location containing RF devices capable of producing, under normal working conditions, levels that exceed those specified in Section Sites with leakage Any device capable of producing leakage that would result in levels close to those specified in Section 2.4 and to which unrestricted public access is allowed, shall be checked for conformity with existing applicable regulations after installation; when malfunction is suspected; and after any modification or repair that might cause leakage. 5. WAR I G SIG S 5.1 Design of the Recommended Warning Signs Three warning signs described here are suggested for use. These signs or reasonable alternatives shall be used. The suggested signs are designed to indicate the nature and degree of hazard associated with a given device or location. The nature of the hazard is indicated by the symbol, and degree of hazard is indicated by the shape and colour of the sign. The warning signs and their meaning are given below. The size of the sign shall be appropriate to the conditions of use, such that it is clearly distinguishable, being either illuminated or employing reflective materials as necessary. The CAUTION sign is BLACK text and symbol on a YELLOW background. The WARNING sign is BLACK text and symbol on an ORANGE background. The DANGER sign is RED text and symbol on a WHITE background. 18
19 The CAUTION sign is not generally used for area demarcation, but it may be placed on devices to indicate that they produce RF fields. 5.2 Area Demarcation Warning sign A WARNING sign shall be placed at the entrance of any zone within which a survey has shown that RF levels exceed those specified in Section 2.4 but are less than those specified in Section 2.3. The WARNING sign indicates that restricted occupancy is allowed for RF and microwave exposed workers within its boundaries. It shall be located wherever it is necessary to indicate a recommended occupancy time. In such cases, the WARNING sign shall be accompanied by words such as "Warning Radiofrequency Radiation - Maximum Occupancy Time (t) Minutes" Danger Sign A DANGER sign shall be placed at the entrance of any zone where the field levels are in excess of those specified in Section 2.3. The DANGER sign thus indicates a DENIED ACCESS zone. When used for area demarcation, the DANGER sign shall be accompanied by words such as "Danger Radiofrequency Radiation - Do Not Enter" and the French equivalent Example of warning signs The signs shall be clearly visible and identifiable at all viewing distances where either significant exposure can occur or at the entrances to restricted area zones. CAUTION RADIOFREQUENCY RADIATION - Area of Unrestricted Occupancy - Minor Injury Possible from Misuse WARNING RADIOFREQUENCY RADIATION - Area of Restricted Occupancy (RF Workers Only) - Serious Injury Possible from Misuse DANGER RADIOFREQUENCY RADIATION - Area of Denied Occupancy - Critical Injury or Death Possible 19
20 6. PROTECTIVE MEASURES RURA notes that the industries causing exposure to electric and magnetic fields are responsible for ensuring compliance with all aspects of the guidelines. 6.1 Controls Measures for the protection of workers include engineering and administrative controls, personal protection programs, and medical surveillance Engineering control Appropriate protective measures must be implemented when exposure in the workplace results in the basic restrictions being exceeded. As a first step, engineering controls should be undertaken wherever possible to reduce device emissions of fields to acceptable levels. Such controls include good safety design and, where necessary, the use of interlocks or similar health protection mechanisms Administrative control Administrative controls, such as limitations on access and the use of audible and visible warnings, should be used in conjunction with engineering controls. Personal protection measures, such as protective clothing, though useful in certain circumstances, should be regarded as a last resort to ensure the safety of the worker; priority should be given to engineering and administrative controls wherever possible. Furthermore, when such items as insulated gloves are used to protect individuals from high-frequency shock and burns, the basic restrictions must not be exceeded, since the insulation protects only against indirect effects of the fields. With the exception of protective clothing and other personal protection, the same measures can be applied to the general public whenever there is a possibility that the general public reference levels might be exceeded. It is also essential to establish and implement rules that will prevent: - Interference with medical electronic equipment and devices (including cardiac pacemakers); - Detonation of electro-explosive devices (detonators); and - Fires and explosions resulting from ignition of flammable materials by sparks caused by induced fields, contact currents, or spark discharges. 20
21 APPE DICES Appendix I. Theoretical Estimation of Exposure Fields A. Near-Field and Far-Field Zones The space around RF source antenna is often divided into two zones: the near-field zone and the far-field zone: Small Antennas: An antenna whose greatest dimension is no greater than the wavelength of its recommended operating frequency is often referred to as a small antenna. Examples of small antennas are resonant dipoles, Yagi and log-periodic antennas. The reactive near-field region of these antennas extends up to a distance given below: Rx = λ/2π.. (I.1) Where Rx = extent of the reactive near-field region, in meters (m) λ = wavelength in meters (m) For this type of antenna, there is no general formula for estimation of the field strength in the near-field zone. However, reasonable calculations can be made for some antennas (e.g., dipoles or monopoles). In general, for most small antennas, theoretical estimation of exposure in the near-field zone is difficult, and only measurements can provide a simple means of field evaluation. Large antennas a ntennas: An antenna with its greatest dimension greater than the wavelength of its recommended operating frequency may be considered as a large antenna. Examples of large antennas are parabolic reflectors, arrays and horn antennas. The near-field zone of these antennas consists of the reactive region extending to the distance given by equation (I.1), followed by a radiating region. The distance from the antenna to the far-field zone is taken to be 2D 2 /λ, where D is the greatest dimension of the antenna and λ is the wavelength. A realistic practical distance from a large antenna, e.g., a parabolic reflector, where the far-field zone begins is: Rf = 0.5 D 2 / λ.. (I.2) Where Rf = distance which marks the beginning of the far-field region, in meters (m) D = The greatest dimension of the antenna, in meters (m) λ = Wavelength in meters (m) 21
22 For commonly used horn and reflector antennas, the maximum power density (within the antenna beam) for distances less than Rf (in the near-field zone) can be conservatively estimated as: Wm = 4PT/A (I.3) Where Wm = maximum power density, in watts per square meter (W/m 2 ) PT = net power delivered to the antenna, in Watts (W) A =m physical aperture area, in square meters (m 2 ) It should be noted that towards the end of the radiating near-field region and in the far-field zone, the electric and the magnetic fields are interrelated with each other and with the power density as follows: E/H = η. (I.4) and W= E 2 /η = H 2 /η (I.5) Where E = Electric field strength, in Volts per meter (V/m) H = Magnetic field strength, in amperes per meter (A/m) W = power density, in Watts per square meter (W/m 2 ) η = characteristic impedance (for free space η = 377 ohms) In the far-field region, the power density (W) on the main beam axis can be calculated from the expression W = EIRP/(4πr 2 ) (I.6) = PTG/(4πr 2 ) Where EIRP = Effective Isotropically Radiated Power, in Watts (W) r = distance from the antenna, in meters (m) PT = net power delivered to the antenna, in Watts (W) G = antenna gain (power ratio) with respect to an isotropic antenna. Equation (I.6) can be used to estimate power (W) at distances greater than Rf (equation I.2). The antenna gain is related to the antenna dimensions by the following equation G = 4πAe/λ 2. (I.7) 22
23 Where Ae = Effective area of the antenna, Ae = εa A = physical aperture area of the antenna, in square meters (m 2 ) ε = antenna efficiency (typically 0.5 ε 0.75) λ = wavelength, in meters (m) An electromagnetic wave can also be characterized by the electric field strength and magnetic field strength. The rms electric field strength at a distance r from a source with the EIRP on the main beam axis, as derived from (I.5) and (I.6), is equal to E = [30EIRP] 0.5 /r. (1.8) and is expressed in volts per meter (V/m) Equations (I.6) and (I.8) are used to determine the power density and field strength in the far-field region in a worst case condition where maximum power gain (Equation I.7) is applied. It should be noted that it is not always possible to predict the levels of maximum fields in and around sites of concern. This is due to the fact that RF fields may be absorbed, reflected and refracted by objects in a random and unpredictable manner. As such, the only way to determine actual levels of RF fields is by measurement. B. Practical Examples 1. Calculation of Minimum Distance Where Exposures Fall within the Limits A 0.5-m diameter parabolic antenna, operating at 1.20 GHz (1200 MHz) with an EIRP of 50 W is to be installed in an area accessible to the general public. What is the minimum distance from the antenna where the exposure does not exceed the limits for the general public? 1. Calculate the maximum power density exposure limit for the general public (Table 4): Wlimit = f/200 = 1200/200 = 6 W/m 2 2. Calculate the minimum distance by rearranging equation (I.6) to solve for the distance from the antenna r: Rmin = [EIRP/(4π.Wlimit)] 0.5 = [50/(4x x6)] 0.5 = m 23
24 3. Check to make sure that the minimum distance calculated above is in the far-field zone (where equation I.6 is valid): First calculate the wavelength: λ = 300/f = 300/1200 = 0.25m As this antenna diameter is larger than the wavelength λ, it may be considered as a large antenna. Thus, the beginning of the far-field region is calculated using equation (I.2) where in this case the parameter D is taken to be the diameter of the dish: Rf = 0.5 D 2 /λ = 0.5x(0.5) 2 /0.25 = 0.5 m Since the minimum distance, as calculated above, is in the far-field zone of the antenna, the basis for the calculation is valid. Therefore, members of the general public should not stand closer than m directly in front of the antenna. 2. Exposure at the ground level The geometry for calculating exposure at the ground level due to an elevated antenna is shown in Figure1 below: 2 m Figure1 Sample configuration for calculating exposure at ground level 24
25 An antenna is installed so that the centre of radiation is at the height h above the ground. The goal of the calculation is to evaluate the power density at a point 2 m above the ground (approximate head level) at a distance x from the tower. In this example the main beam is parallel to the ground and the antenna gain is axially symmetrical (omnidirectional). After calculations, the power density becomes: 2.56 EIRP S = F( θ) 4π 2 x + h 2 For example, if the antenna is a half-wave dipole, the relative numeric gain is of the form of: 2 π cos sin θ 2 F ( θ, φ) = cosθ Then, for a source with EIRP of 1000 W, the exposure power as a function of x is shown in Figure2 for three different heights. Figure2 Power density at the ground level vs distance from the tower calculated for the example in Figure8. 25
26 3. Safety at base station sites Close to some base station antennas, the power density can exceed guideline levels. Operators calculate compliance distances in various directions from their antennas in order to define a boundary outside which the guidelines can never be exceeded. Preventative measures such as administrative procedures or physical barriers are implemented to ensure that people do not accidentally enter regions defined as exclusion zones. The design of sites would normally be such that the general public would not be able to stray into regions designed as exclusion zones. For large macro cellular base stations radiating up to 100 watts or more, exclusion zones in the range m may be required in front of the antennas to ensure exposures remain within the ICNIRP guidelines for public exposure. In other directions such as below and behind the antennas, the exclusion zones would extend for lesser distances. Low power microcellular base stations radiating around 1-2 W would require much smaller exclusion zones than macrocells and it may be possible to fully encompass all regions where exposure could exceed guidelines within the plastic cover of the antenna. 26
27 Appendix II. Terms and definitions General public: comprises individuals of all ages and of varying health status, and may include particularly susceptible groups or individuals. In many cases, members of the public are unaware of their exposure to EMF. Moreover, individual members of the public cannot reasonably be expected to take precautions to minimize or avoid exposure. It is these considerations that underlie the adoption of more stringent exposure restrictions for the public than for the occupationally exposed population Controlled/occupational exposure: Controlled/occupational exposure applies to situations where persons are exposed as a consequence of their employment and in which those persons who are exposed have been made fully aware of the potential for exposure and can exercise control over their exposure. Occupational/controlled exposure also applies where the exposure is of transient nature as a result of incidental passage through a location where the exposure limits may be above the general population/uncontrolled limits, as long as the exposed person has been made fully aware of the potential for exposure and can exercise control over his or her exposure by leaving the area or by some other appropriate means. Equivalent t Isotropically Radiated Power (EIRP): The EIRP is the product of the power supplied to the antenna and the maximum antenna gain relative to an isotropic antenna. Exposure xposure: Exposure occurs wherever a person is subjected to electric, magnetic or electromagnetic fields, or to contact currents other than those originating from physiological processes in the body or other natural phenomena. Exposure level: Exposure level is the value of the quantity used when a person is exposed to electromagnetic fields or contact currents. Far-field region: That region of the field of an antenna where the angular field distribution is essentially independent of the distance from the antenna. In the far-field region, the field has a predominantly plane-wave character, i.e., locally uniform distribution of electric field strength and magnetic field strength in planes transverse to the direction of propagation. Induced current: Induced current is the current induced inside the body as a result of direct exposure to electric, magnetic or electromagnetic fields. Near ear-field region: The near-field region exists in proximity to an antenna or other radiating structure in which the electric and magnetic fields do not have a substantially plane-wave character but vary considerably from point-to-point. The near-field region is further subdivided into the reactive near-field region, which is closest to the radiating structure and that contains most or nearly all of the stored energy, and the radiating near-field region 27
28 where the radiation field predominates over the reactive field, but lacks substantial planewave character and is complicated in structure. NOTE For many antennas, the outer boundary of the reactive near-field is taken to exist at a distance of one-half wavelength from the antenna surface. Power density (W):( Power flux-density is the power per unit area normal to the direction of electromagnetic wave propagation, usually expressed in units of Watts per square meter (W/m 2 ). Power density, peak: The peak power density is the maximum instantaneous power density occurring when power is transmitted. Power density, plane-wave equivalent (Seq( eq): The equivalent plane-wave power density is a commonly used term associated with any electromagnetic wave, equal in magnitude to the power flux-density of a plane wave having the same electric (E) or magnetic (H) field strength. Specific absorption ( SA): (SA Specific absorption is the quotient of the incremental energy (dw) absorbed by (dissipated in) an incremental mass (dm) contained in a volume element (dv) of a given density (ρm). SA= dw dm = 1 ρ m dw dv The specific absorption is expressed in units of joules per kilogram (J/kg). Contact current: Contact current is the current flowing into the body by touching a conductive object in an electromagnetic field. Specific absorption rate ( SAR): (SAR The time derivative of the incremental energy (dw) absorbed by (dissipated in) an incremental mass (dm) contained in a volume element (dv) of a given mass density (ρm). SAR= d dw dt dm SAR is expressed in units of watts per kilogram (W/kg). Wavelength (λ): ( The wavelength of an electromagnetic wave is related to frequency (f) and velocity (v) of an electromagnetic wave by the following expression: λ = In free space, the velocity is equal to the speed of light (c) which is approximately m/s. = ν f d dt 1 ρ m dw dv 28
29 References 1. International Commission on Non-Ionizing Radiation Protection. ICNIRP Guidelines: Guidelines for Limiting Exposure to Time-Varying Electric, Magnetic, and Electromagnetic Fields (up to 300 GHz). Health Physics, Vol. 74, pp , ITU-T K.52. Telecommunication standardization sector of ITU, Series K: protection against interference. Guidance on complying with limits for human exposure to electromagnetic fields, 12/ World Health Organization. Environmental Health Criteria 137: Electromagnetic Fields (300 Hz 300 GHz), World Health Organisation. The international EMF Project 5. Health Canada, Safety Code6, Limits of Human Exposure to Radiofrequency Electromagnetic Fields in the Frequency Range from 3 khz to 300 GHz 6. Telecommunication Engineering Centre Khurshid Lal Bhavan, Janpath New Delhi India. Draft Guidelines for Complying with Limits for Human Exposure to Electromagnetic Fields( Base Station Antennas and Mobile Telephones/Terminals) 7. National Institute of Environmental Health Sciences, National Institutes of Health. Electric and Magnetic Fields Associated with the Use of Electric Power, June Environment & Society Working Group. EMF Exposure Standards Applicable in Europe and Elsewhere, May, Radiation and Environmental Health Department of Protection of the Human Environment, World Health Organization. Establishing a Dialogue on Risks from Electromagnetic Fields, Geneva, Switzerland Federal Communications Commission, Office of Engineering & Technology. Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields. OET Bulletin 65, Edition 97-01, August Telecommunications Authority of Trinidad and Tobago. Proposed Maximum Permissible Exposure Limits for Radiofrequency Radiation in Trinidad and Tobago, October 6, 2006 Done at Kigali, on Kigali, on 11/11/2009 Signed MUKASI E Marie Claire Chairperson Regulatory Board. 29
30 30
Limits of Human Exposure to Radiofrequency Electromagnetic Fields in the Frequency Range from 3 khz to 300 GHz
Health Canada Santé Canada Limits of Human Exposure to Radiofrequency Electromagnetic Fields in the Frequency Range from 3 khz to 300 GHz Safety Code 6 Limits of Human Exposure to Radiofrequency Electromagnetic
Selected Radio Frequency Exposure Limits
ENVIRONMENT, SAFETY & HEALTH DIVISION Chapter 50: Non-ionizing Radiation Selected Radio Frequency Exposure Limits Product ID: 94 Revision ID: 1736 Date published: 30 June 2015 Date effective: 30 June 2015
RF safety at base station sites
RF safety at base station sites CONTENTS 1 Purpose and scope................................................. 2 2 Introduction........................................................ 2 3 Basic information...................................................
Technical limits of Human Exposure to RF from Cellular Base Stations and Handsets
Ministry of Environmental Protection Ministry of Communications Technical limits of Human Exposure to RF from Cellular Base Stations and Handsets Based on author s PhD thesis/book- An analysis of regulatory
Human Exposure Limits
Human Exposure Limits Session 3 0 Version December 2014 Learning objectives In this session we will: Learn about the international exposure limits for workers and the public Learn about methods for assessing
COUNCIL RECOMMENDATION of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) (1999/519/EC)
COUNCIL RECOMMENDATION of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) (1999/519/EC) THE COUNCIL OF THE EUROPEAN UNION, Having regard to
ARIB TR-T12-34.925 V3.0.0. Specific Absorption Rate (SAR) requirements and regulations in different regions
ARIB TR-T12-34.925 V3.0.0 Specific Absorption Rate (SAR) requirements and regulations in different regions Refer to "Notice" in the preface of ARIB TR-T12 for Copyrights. Technical Report 3rd Generation
Official Journal of the European Communities. (Acts whose publication is not obligatory) COUNCIL
30. 7. 1999 EN Official Journal of the European Communities L 199/59 II (Acts whose publication is not obligatory) COUNCIL COUNCIL RECOMMENDATION of 12 July 1999 on the limitation of exposure of the general
Technical Guide for Interpretation and Compliance Assessment of Health Canada s Radiofrequency Exposure Guidelines
Technical Guide for Interpretation and Compliance Assessment of Health Canada s Radiofrequency Exposure Guidelines Technical Guide for Interpretation and Compliance Assessment of Health Canada s Radiofrequency
The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz
The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz J. Klima, R. Ščehovič Department of Physics, Faculty of Natural Sciences, University of Mathias Bel, Tajovského
ETSI TR 101 870 V1.1.1 (2001-11)
TR 101 870 V1.1.1 (2001-11) Technical Report Fixed radio transmitter sites; Exposure to non-ionising electromagnetic fields; Guidelines for working conditions 2 TR 101 870 V1.1.1 (2001-11) Reference DTR/SAFETY-00004
RF EXPOSURE LIMITS AND TESTING REQUIREMENTS
RF EXPOSURE LIMITS AND TESTING REQUIREMENTS Jay Moulton Vice President March 12, 2013 1 OVERVIEW Specific Absorption Rate (SAR) and Maximum Permissible Exposure (MPE) Standards and Limits Evaluation Methods
The Existing Public Exposure Standards Cindy Sage, MA Sage Associates, USA
SECTION 3 _ The Existing Public Exposure Standards Cindy Sage, MA Sage Associates, USA Prepared for the BioInitiative Working Group August 2007 The US Federal Communications Commission (FCC) Exposure Standard
Millennium Product Inc. Model: Cell Shield / Zorb
Millennium Product Inc. Cell Shield / Zorb Prepared by PCTEST LAB Issued on: 10/22/2015 Report Version 2.6 NOTE: SAR results only apply to the device tested. Although the device may have had different
Electromagnetic radiation exposure: assessment against ACA mandated limits
Electromagnetic radiation exposure: assessment against ACA mandated limits Paging services (Edition May 2002) Disclaimer Unless otherwise specified, the information contained in these guidelines is intended
Electromagnetic Field Safety
SAR A Basic Restriction for Electromagnetic Field Safety David Baron, PE Consulting Engineer Electromagnetic Field Safety [email protected] NOTE. CENAM is not responsible for the content of this document.
AN OVERVIEW OF STANDARDS AND REGULATION CONCERNING EXPOSURE TO RADIOFREQUENCY FIELDS
AN OVERVIEW OF STANDARDS AND REGULATION CONCERNING EXPOSURE TO RADIOFREQUENCY FIELDS Annamaria PALJANOS, [email protected] Călin MUNTEANU [email protected] TECHNICAL UNIVERSITY CLUJ NAPOCA,
Human Exposure to Outdoor PLC System
1602 PIERS Proceedings, Marrakesh, MOROCCO, March 20 23, 2011 Human Exposure to Outdoor PLC System Vicko Doric 1, Dragan Poljak 1, and Khalil El Khamlichi Drissi 2 1 University of Split, Croatia 2 Blaise
Electromagnetic radiation exposure: assessment against ACA mandated limits
Electromagnetic radiation exposure: assessment against ACA mandated limits General radio services (operating above 0 MHz) (Edition May 0) Disclaimer Unless otherwise specified, the information contained
Wireless Broadband: Health & Safety Information
Wireless Broadband: Health & Safety Information Introduction The increasing use of mobile phones and other wireless technology has been accompanied by public debate about possible adverse effects on health.
THE ANSI/IEEE RF SAFETY STANDARD AND ITS RATIONALE. Om P. Gandhi and Gianluca Lazzi Department of Electrical Engineering Salt Lake City, Utah 84112
Introduction THE ANSI/IEEE RF SAFETY STANDARD AND ITS RATIONALE Om P. Gandhi and Gianluca Lazzi Department of Electrical Engineering Salt Lake City, Utah 84112 In 1960, the American Standards Association
EMR COMPLIANCE HOW TO ENSURE YOUR NATA ACCREDITED CONTRACTOR IS ABLE TO PROVIDE A NATA ENDORSED REPORT
EMR COMPLIANCE HOW TO ENSURE YOUR NATA ACCREDITED CONTRACTOR IS ABLE TO PROVIDE A NATA ENDORSED REPORT Chris Zombolas Technical Director, EMC Technologies Pty Ltd 57 Assembly Drive Tullamarine Vic. 3043,
Working safely around Radiofrequency (RF) Transmitters
Working safely around Radiofrequency (RF) Transmitters Exposure to excessive levels of radiofrequency (RF) emissions may affect your health This Mobile Carriers Forum (MCF) Fact sheet series is designed
Annex to the joint statement: Exposure of the general public to radiofrequency fields
16 November 2009 Annex to the joint statement: Exposure of the general public to radiofrequency fields 1. Introduction This document presents typical exposure of the general public to radiofrequency (RF)
National Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields
November 2009 Contents 1 PRELIMINARY AND GENERAL... 5 1.1 CITATION... 5 1.2 ORIGIN AND STATUS OF THE NATIONAL GUIDELINES... 5 1.3 PURPOSE... 5 1.4 SCOPE AND APPLICATION... 6 1.5 TERMS AND DEFINITIONS...
Electromagnetic Radiation Compatibility Survey and Safety Analysis around Mobile Base Transceiver Stations: Case Studies around Kathmandu Valley
Research Journal of Engineering Sciences ISSN 2278 9472 Electromagnetic Radiation Compatibility Survey and Safety Analysis around Mobile Base Transceiver Stations: Case Studies around Kathmandu Valley
IEC TC106. Standards for the Assessment of Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 to 300 GHz
International Electrotechnical Commission IEC TC106 Standards for the Assessment of Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 to 300 GHz R. C. Petersen Chairman Secretariat and
Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands)
Issue 3 June 2009 Spectrum Management and Telecommunications Radio Standards Specification Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) Aussi disponible
Radiation Protection Series
Radiation The Radiation is published by the Australian Radiation and Nuclear Safety Agency (ARPANSA) to promote practices which protect human health and the environment from the possible harmful effects
Keywords Mobile Tower Radiations, Electromagnetic Radiations, Signal Strength, Mobile Phone
Volume 5, Issue 1, January 2015 ISSN: 2277 128X International Journal of Advanced Research in Computer Science and Software Engineering Research Paper Available online at: www.ijarcsse.com Analysis of
ELECTROMAGNETIC FIELDS AND PUBLIC HEALTH HEALTH AND SAFETY GUIDELINES #1
SINGAPORE, 16 AUGUST 2001 HEALTH SCIENCES AUTHORITY PRESS RELEASE ELECTROMAGNETIC FIELDS AND PUBLIC HEALTH HEALTH AND SAFETY GUIDELINES #1 THE EMF HEALTH ISSUE 1 Over the past years a large number of scientific
Clean, Green and Safe Management System
Clean, Green and Safe Management System SP 24-38: Working with Radio Frequency Radiation - Minimum Requirements Author : Communications Network Operations Centre Manager A. Reece Checked by: Manager Communications/
Guidelines on the assessment of installations against electromagnetic radiation (EMR) exposure limits
Guidelines on the assessment of installations against electromagnetic radiation (EMR) exposure limits (Edition eptember 000) Disclaimer Unless otherwise specified, the information contained in these guidelines
Automated Meter Reading Frequently Asked Questions. What is AMR?
Automated Meter Reading Frequently Asked Questions What is AMR? AMR stands for Automated Meter Reading. It is a method of using advanced communications technology to read meters remotely. It reduces human
Radio waves and health. Mobile communications
Radio waves and health Mobile communications Mobile communications and health Mobile telephony Radio communications have been used for more than a hundred years in various sorts of applications. Already
Amplification of the Radiation from Two Collocated Cellular System Antennas by the Ground Wave of an AM Broadcast Station
Amplification of the Radiation from Two Collocated Cellular System Antennas by the Ground Wave of an AM Broadcast Station Dr. Bill P. Curry EMSciTek Consulting Co., W101 McCarron Road Glen Ellyn, IL 60137,
HUMAN EXPOSURE TO EMR: ASSESSMENT OF AMATEUR RADIO STATIONS FOR COMPLIANCE WITH ACA REQUIREMENTS
HUMAN EXPOSURE TO EMR: ASSESSMENT OF AMATEUR RADIO STATIONS FOR COMPLIANCE WITH ACA REQUIREMENTS May 2005 Version 2.0 PO Box 78 BELCONNEN ACT 2616 Telephone (02) 6219 5555 Facsimile (02) 6219 5353 www.aca.gov.au
Real-life Applications of ICNIRP Guidelines to Various Human EMF Exposure Issues
Technical Forum Overview and Latest Development of Standards in Human Exposure to Electromagnetic Fields (EMF) Real-life Applications of ICNIRP Guidelines to Various Human EMF Exposure Issues Dr. Brian
Questions and Answers about Biological Effects and Potential Hazards of Radiofrequency Electromagnetic Fields
Federal Communications Commission Office of Engineering & Technology Questions and Answers about Biological Effects and Potential Hazards of Radiofrequency Electromagnetic Fields OET BULLETIN 56 Fourth
Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules
Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules Craig W. Fanning Elite Electronic Engineering, Inc. 1516 Centre Circle Downers
Human Exposure to Radiofrequency Electromagnetic Radiation
Australia s regulator for broadcasting, the internet, radiocommunications and telecommunications www.acma.gov.au Human Exposure to Radiofrequency Electromagnetic Radiation Information for licensees of
Product Safety and RF Exposure for Mobile Two-Way Radios Installed in Vehicles or as Fixed Site Control Stations
Product Safety and RF Exposure for Mobile Two-Way Radios Installed in Vehicles or as Fixed Site Control Stations! C a u t i o n BEFORE USING THIS RADIO, READ THIS BOOKLET WHICH CONTAINS IMPORTANT OPERATING
EMR Exposure Limits & Assessment Methods for Mobile Phone Communications. Lindsay Martin Manager, Non-Ionising Radiation Section
EMR Exposure Limits & Assessment Methods for Mobile Phone Communications Lindsay Martin Manager, Non-Ionising Radiation Section Introduction How can we use Wireless Communication Safely? Wireless communication
Effects of Mobile Phone Radiation onto Human Head with Variation of Holding Cheek and Tilt Positions
Effects of Mobile Phone Radiation onto Human Head with Variation of Holding Cheek and Tilt Positions M. R. Iqbal-Faruque* 1, N. Aisyah-Husni 2, Md. Ikbal-Hossain 1, M. Tariqul-Islam 2 and N. Misran 2 1
Specific Absorption Rate (SAR) Induced in Human Heads of Various Sizes When Using a Mobile Phone
, June 30 - July 2, 2010, London, U.K. Specific Absorption Rate (SAR) Induced in Human Heads of Various Sizes When Using a Mobile Phone Adel Z. El Dein Alaeddin Amr Abstract - This paper analyzes the specific
RICHARD T ELL ASSOCIATES,INC.
RICHARD T ELL ASSOCIATES,INC. An Evaluation of Test Measurement Data Obtained on the KW-Gard RF Protective Suit March 30, 1998 Prepared for Euclid Garment Manufacturing Company 333 Martinel Drive Kent,
VK3UM Electro Magnetic Radiation Calculator. Table of Contents
Table of Contents VK3UM EMR Calculator 2 Disclaimer 2 Background 3 Program Objectives 4 Calculations Provided 5 Screen Options 7 Circular Apertures 14 Calculation Methods 16 Examples 17 Author 19 References
Radio Frequency Exposure Test Report
Radio Frequency Exposure EN 62311 January 2008 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0Hz 300GHz) (IEC 62311:2007, modified)
Advanced Measurements of Microwave Oven Leakage
Conference paper Advanced Measurements of Microwave Oven Leakage M. Bangay [1] C. Zombolas [2] 1. Australian Radiation Protection and Nuclear Safety Agency 2. EMC Technologies Pty Ltd Abstract Reports
How To Know If You Are Safe To Use An Antenna (Wired) Or Wireless (Wireless)
1 2 The range of RF spans 3 KHz (3000 Hz) to 300 GHz (300 million Hz) Frequencies of RF devices range from the low frequency AM broadcasts (80 MHz) to higher frequency mobile phones (1900 MHz) smart meters
EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec.
EMC STANDARDS The EMC standards that a particular electronic product must meet depend on the product application (commercial or military) and the country in which the product is to be used. These EMC regulatory
Exposure to Radio Waves near Mobile Phone Base Stations
NRPB-R Exposure to Radio Waves near Mobile Phone Base Stations S M Mann, T G Cooper, S G Allen, R P Blackwell and A J Lowe Abstract Measurements of power density have been made at 7 sites where people
RADIOFREQUENCY RADIATION, (RFR): (RFR Information - Technology Newsletter, Full Version)
RADIOFREQUENCY RADIATION, (RFR): (RFR Information - Technology Newsletter, Full Version) George M. Harris, P.E. (Revised February, 2011) Questions: -What is Radiofrequency Radiation, (RFR)? -With SO MANY
Operating Frequency Selection for Loosely Coupled Wireless Power Transfer Systems with Respect to RF Emissions and RF Exposure Requirements
Operating Frequency Selection for Loosely Coupled Wireless Power Transfer Systems with Respect to RF Emissions and RF Exposure Requirements Jagadish Nadakuduti, Lin Lu, Paul Guckian Qualcomm Technologies,
ELECTROMAGNETIC ENERGY Evaluation and Management for Antenna Sites
ELECTROMAGNETIC ENERGY Evaluation and Management for Antenna Sites 10/9/97 Revised 12/27/2001 The purpose of this document is to provide information to assist the reader in understanding the concepts required
SITE RADIATION SURVEY
SITE RADIATION SURVEY Site X, zzz Town XX XXXXXXX, XXXXXXX Site ID No: 12345 Dated: 29.09.2007 1 CONTENTS 1.0 SCOPE... 3 2.0 EQUIPMENT... 4 3.0 TRANSMITTERS... 5 4.0 FM Antenna Details... 7 6.0 GENERAL...
Users Manual FA106 / FA306 version 1.0. Field Analyzer. FA106 and FA306. Users Manual
Field Analyzer FA106 and FA306 Users Manual 1 Contents Contents...2 Preface...3 Chapter 1 Basic Functions...4 1.1 Turning on/off...4 1.2 Choosing the required measuring mode...4 1.3 Picture of front panel...5
Environmental Health and Safety
Environmental Health and Safety Standard Operating Guideline RF & Microwave Safety Program 1.0 Purpose and Requirements This guide will present a summary of the basics of radiofrequency (RF) and microwave
Antenna Properties and their impact on Wireless System Performance. Dr. Steven R. Best. Cushcraft Corporation 48 Perimeter Road Manchester, NH 03013
Antenna Properties and their impact on Wireless System Performance Dr. Steven R. Best Cushcraft Corporation 48 Perimeter Road Manchester, NH 03013 Phone (603) 627-7877 FAX: (603) 627-1764 Email: [email protected]
IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec
IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec This value-packed VuSpec CD-ROM represents the most complete resource available for professional engineers looking for
MSAN-001 X-Band Microwave Motion Sensor Module Application Note
1. Introduction HB Series of microwave motion sensor module are X-Band Mono-static DRO Doppler transceiver front-end module. These modules are designed for movement detection, like intruder alarms, occupancy
Human exposure to RF
INTERNATIONAL ELECTROTECHNICAL COMMISSION Human exposure to RF Don Heirman ACEC/TC106 Liaison Representative APEMC symposium May 2015 Copyright IEC, Geneva, Switzerland TC106 Scope To prepare international
REVIEW OF EXPOSURE LIMITS AND HEALTH CONCERNS SANTA ANA. Base Station Telecommunication Transmitters UNIFIED SCHOOL DISTRICT
SANTA ANA UNIFIED SCHOOL DISTRICT REVIEW OF EXPOSURE LIMITS AND HEALTH CONCERNS Base Station Telecommunication Transmitters Dr. Karl Rodenbaugh, Senior Scientist SCOPE OF SERVICES Review, Describe, Discuss,
SR Communications Tower Task Force Dr. Jeff Liva, Allen Cohen, Rebecca Rogers
SR Communications Tower Task Force Dr. Jeff Liva, Allen Cohen, Rebecca Rogers 1 Table of Contents 2 Chemical hazards. These develop from excessive exposure to concentrations of chemicals in environment.
OpenWay Radio Frequency FAQ
OpenWay Radio Frequency FAQ March 10, 2010 2010, Itron Inc. All rights reserved. 1 Overview This document provides general information about radiofrequency (RF) electromagnetic fields from OpenWay wireless
3 Radio Waves and Human Body 8 Specific Absorption Rate (SAR)... 8 SAR value of a mobile handset... 8 Radiation level by a mobile tower...
i Mobile Communication- Radio Waves & Safety Content 1 Overview 3 2 Radio Waves in Cellular Communication System 4 Radio waves... 4 Electric field, Magnetic field... 4 Electromagnetic field (EMF)... 4
5. ANTENNA TYPES. Figure 5. The vertical dipole and its electromagnetic equivalent, the vertical monopole
Antennas can be classified in several ways. One way is the frequency band of operation. Others include physical structure and electrical/electromagnetic design. The antennas commonly used for LMR both
Occupational Exposure Assessment on an FM Mast: Electric Field and SAR Values
International Journal of Occupational Safety and Ergonomics (JOSE) 2012, Vol. 18, No. 2, 149 159 Occupational Exposure Assessment on an FM Mast: Electric Field and SAR Values Blaž Valič Institute of Non-Ionizing
Measurements of radiofrequency fields from a WEL Networks Smart Meter
Measurements of radiofrequency fields from a WEL Networks Smart Meter Report 2012/36 This report was prepared for: WEL Networks Ltd P O Box 925 Hamilton Report prepared by: Martin Gledhill Finalised: 7
MEMORANDUM. Amy Kahler, Director of Customer Service and Marketing Mike McCurnin, P.E., Director of Water Production
DES MOINES WATER WORKS Board of Water Works Trustees 2201 George Flagg Parkway Des Moines, Iowa 50321-1190 (515) 283-8700 www.dmww.com MEMORANDUM DATE: February 4, 2015 TO: FROM: SUBJECT: William Stowe,
Antenna Glossary Before we talk about specific antennas, there are a few common terms that must be defined and explained:
Antenna Basics Introduction Antennas are a very important component of communication systems. By definition, an antenna is a device used to transform an RF signal, traveling on a conductor, into an electromagnetic
Understanding Range for RF Devices
Understanding Range for RF Devices October 2012 White Paper Understanding how environmental factors can affect range is one of the key aspects to deploying a radio frequency (RF) solution. This paper will
Radio Frequency Electromagnetic Energy (RF-EME) Compliance Report (Predictive Modeling)
Radio Frequency Electromagnetic Energy (RF-EME) Compliance Report (Predictive Modeling) Prepared for: AT&T Mobility, LLC 7655-7665 Redwood Blvd. Novato,CA 94945 USID# 118154 Site No. CNU2701 DUCKHORN DR.
Non-Ionizing Electromagnetic Radiation
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike License. Your use of this material constitutes acceptance of that license and the conditions of use of materials on this
Selecting Receiving Antennas for Radio Tracking
Selecting Receiving Antennas for Radio Tracking Larry B Kuechle, Advanced Telemetry Systems, Inc. Isanti, Minnesota 55040 [email protected] The receiving antenna is an integral part of any radio location
What are radio signals?
Mobile phones and other wireless technologies have become an integral part of everyday life. But does using a mobile phone regularly, or living near a base station, have any implications for our health?
Current Probes. User Manual
Current Probes User Manual ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall
LTE: Technology and Health. 4G and Mobile Broadband
LTE: Technology and Health 4G and Mobile Broadband LTE Technology and Health Mobile Broadband typically refers to providing customers with high speed data while on the move. There are several technologies
The Salzburg Model: A Precautionary Strategy for Siting of Base Stations
The Salzburg Model: A Precautionary Strategy for Siting of Base Stations Dr. Gerd Oberfeld, Dr. Christoph König Federal State of Salzburg, Public Health Department, Environmental Health P.O. Box 527, A-5010
Scaling Public Concerns of Electromagnetic Fields Produced by Solar Photovoltaic Arrays
Scaling Public Concerns of Electromagnetic Fields Produced by Solar Photovoltaic Arrays Introduction In our modern society electricity is vital to our health, safety, comfort and well-being. While our
Antenna Basic Concepts
ANTENNA An antenna is a device to transmit and/or receive electromagnetic waves. Electromagnetic waves are often referred to as radio waves. Most antennas are resonant devices, which operate efficiently
Antennas & Propagation. CS 6710 Spring 2010 Rajmohan Rajaraman
Antennas & Propagation CS 6710 Spring 2010 Rajmohan Rajaraman Introduction An antenna is an electrical conductor or system of conductors o Transmission - radiates electromagnetic energy into space o Reception
Regulation for wireless telecommunication equipment
Wireless devices Regulation for wireless telecommunication equipment * Wireless home telephones * Baby monitors * Wireless on the Internet * Bluetooth * Comparison of SAR values Introduction Do you wonder
Radiofrequency Fields from Mobile Phone Technology
4 Radiofrequency Fields from Mobile Phone Technology Radiofrequency Radiation Usage 4.1 Mobile phones and their base stations transmit and receive signals using electromagnetic waves (also referred to
COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT
COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT 1. SCOPE This Common Regulatory Objective, CRO, is applicable to Wireless Local Area
Mobile Phones: Jargon Explained
Mobile Phones: Jargon Explained 2G 3G Aerial Second Generation Mobile Phone System. See GSM See Third Generation Mobile Phone System. Device designed to radiate and receive electromagnetic energy. Antenna
Mobile Phone Base-Station Audit
Mobile Phone Base-Station Audit Audit site: Aylesbury Road Wing Leighton Buzzard Beds LU7 0NY The Office of Communications (Ofcom) is responsible for management of the civil radio spectrum in the UK. Following
Thermal Effects of Mobile Phones
Thermal Effects of Mobile Phones S. Kassimi 1, A. ELfadl, S. Bri 3, A. Nakheli 4, M. Habibi 5, M. Ben Ahmed 6 Systems and Telecommunications Engineering Decision Laboratory,Ibn Tofail University, Faculty
ELECTRIC POWER FREQUENCY (60 Hz) ELECTRIC AND MAGNETIC FIELDS (EMFs)
ELECTRIC POWER FREQUENCY (60 Hz) ELECTRIC AND MAGNETIC FIELDS (EMFs) WHAT ARE EMFs? Electrical power lines, wiring, transformers and appliances (computers, coffeemakers, shavers, telephones, hair dryers,
EMC Standards: Standards of good EMC engineering
Electromagnetic Compatibility (EMC) IEEE Definition Origin, control, and measurement of electromagnetic effects on electronic and biologic systems. IEEE EMC Society Areas of Interest EMC Standards: Standards
Exposure to EMFs from Lightweight Aviation Transponders
HPA-RPD-31 Exposure to EMFs from Lightweight Aviation Transponders M Khalid and S M Mann ABSTRACT An investigation has been carried out to determine exposure to electromagnetic fields from proposed lightweight
Physics 6C, Summer 2006 Homework 2 Solutions
Physics 6C, Summer 006 Homework Solutions All problems are from the nd edition of Walker. Numerical values are different for each student. Chapter 3 Problems. Figure 3-30 below shows a circuit containing
VK3UM Electro-magnetic Radiation Calculator. Table of Contents
Table of Contents Disclaimer 2 Background 3 Glossary of terms 4 Program Objectives 5 Calculations provided 6 Screen Options 8 Safe Elevation Angle 18 Australian Level 1 and Level 2 requirements 21 Screen
Prudent Avoidance Policy on Siting Telecommunication Towers and Antennas
STAFF REPORT ACTION REQUIRED Prudent Avoidance Policy on Siting Telecommunication Towers and Antennas Date: November 20, 2007 To: From: Wards: Board of Health Medical Officer of Health All Reference Number:
MEASUREMENT AND ANALYSIS OF RF EME LEVELS FROM MOBILE TELEPHONE BASE STATIONS LOCATED AT LEICHHARDT, NSW
AUSTRALIAN RADIATION PROTECTION AND NUCLEAR SAFETY AGENCY A R P N S A Lower Plenty Road YALLAMBIE VIC 3085 Phone 61 3 9433 2211 Fax 61 3 9432 1835 E-mail: [email protected] Web: www.arpansa.gov.au
GSM Base Station Radiation Level: A Case Study of University of Nigeria Environment
INTERNATIONAL JOURNAL OF SCIENTIFIC & TECHNOLOGY RESEARCH VOLUME 1, ISSUE 8, SEPTEMBER 212 ISSN 2277-8616 GSM Base Station Radiation Level: A Case Study of University of Nigeria Environment Mamilus. A.
Mobile use, radio signals and health
Mobile use, radio signals and health Mobile use, radio signals and health How does the mobile network work? Since the 1970s, the use of various types of radio transmitters has risen dramatically, to the
TCB RF Exposure Training
TCB RF Exposure Training RF Exposure (RFx( RFx) ) Coming Attractions Goals for Exclusion List Handoff Exposure Categories and Considerations Collocated Devices Tim Harrington, FCC/OET/EAB February 13-15,
How To Understand The Kv3Um Electro Magnetic Radiation
Acknowledgements WIA Spectrum Committee Michael Owen.. SK VK3KI.. founder of the modern WIA. Phil Wait VK2ASD [President WIA]. Roger Harrison VK2ZRH [WIA Director]. Peter Young VK3MV [ex Director and ACMA].
