Svensk läkemedelsstandard

Similar documents
LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

Summer Holidays Questions

Public Assessment Report Scientific discussion. Medicinsk lustgas Yara Industrial, 100% medicinal gas, liquefied Nitrous oxide SE/H/659/01/DC

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

SUCRALOSE. White to off-white, practically odourless crystalline powder

Module 5: Combustion Technology. Lecture 33: Combustion air calculation

MINERAL OIL (MEDIUM VISCOSITY)

IB Chemistry. DP Chemistry Review

ß-CYCLODEXTRIN SYNONYMS

INTI COLLEGE MALAYSIA A? LEVEL PROGRAMME CHM 111: CHEMISTRY MOCK EXAMINATION: DECEMBER 2000 SESSION m/e

23 The Thermal Conductivity Detector

DRAFT MONOGRAPH FOR THE INTERNATIONAL PHARMACOPOEIA PARACETAMOL ORAL SUSPENSION (September 2010)

HEXANES. Insoluble in water, soluble in ether, alcohol, and acetone. Neutral to methyl orange (ph indicator) Not more than 0.

Halogen Free: What, Why and How. Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc.

ERDOSTEINE - MONOGRAPH.

SIX REASONS TO DRY BIOGAS To A LOW DEWPOINT BEFORE COMBUSTION IN A CHP ENGINE STEVEN SCOTT MARKET DEVELOPMENT MANAGER ALTERNATIVE ENERGIES

Process gases for analytical applications

CHEMISTRY II FINAL EXAM REVIEW

α-cyclodextrin SYNONYMS α-schardinger dextrin, α-dextrin, cyclohexaamylose, cyclomaltohexaose, α- cycloamylase

Fundamentals of Gas Chromatography

Chapter 2 Chemical and Physical Properties of Sulphur Dioxide and Sulphur Trioxide

ON BOARD EXHAUST EMISSION MONITORING OF ROAD VEHICLES - A HIGH TECH SOLUTION TO POLLUTION FROM TRAFFIC?

The photoionization detector (PID) utilizes ultraviolet

3 - Atomic Absorption Spectroscopy

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

POLYVINYL ALCOHOL. SYNONYMS Vinyl alcohol polymer, PVOH, INS No DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

Best Practice in Boiler Water Treatment

How To Choose A Total Organic Carbon Analyzer

Validation and Calibration of Analytical Instruments a D.Gowrisankar, b K.Abbulu, c O.Bala Souri, K.Sujana*

Chemistry Assessment Unit AS 1

Chapter 16: Tests for ions and gases

F321 MOLES. Example If 1 atom has a mass of x g 1 mole of atoms will have a mass of x g x 6.02 x = 7.

Technique of Monitoring Dioxins in Flue Gas from MSW Incinerators using Dioxin Precursor Analyzer

LACHAT METHOD NUMBER D Rev 1, 21 March 2011 SCOPE AND APPLICATION Approximately g CN/L g CN/L. 09e

Hydrogen as an alternative to Helium for gas chromatography.

Effects of Temperature, Pressure and Water Vapor on Gas Phase Infrared Absorption by CO 2

(a) Method 1 Sample and Velocity Traverses for Stationary Sources.

Fractional Distillation and Gas Chromatography

ATOMS. Multiple Choice Questions

Lecture 35: Atmosphere in Furnaces

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

POINT SOURCES OF POLLUTION: LOCAL EFFECTS AND IT S CONTROL Vol. I - Air Pollution Caused by Industries - Jiming HAO and Guowen LI

CERTIFICATE OF ANALYSIS Methyl 4-Hydroxybenzoate

AS1 MOLES. oxygen molecules have the formula O 2 the relative mass will be 2 x 16 = 32 so the molar mass will be 32g mol -1

CHEMICAL REACTIONS AND REACTING MASSES AND VOLUMES

Public Assessment Report Scientific discussion. Prednisolon mibe (prednisolone acetate) SE/H/1317/01/DC

Multiple Choice questions (one answer correct)

Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants

Protocol: HPLC (amino acids)

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

MATHESON STACK EMISSION CALIBRATION PROGRAM. Experience the MATHESON Commitment to Supply Chain Excellence

Chapter 1: Moles and equations. Learning outcomes. you should be able to:

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

TANNIC ACID. SYNONYMS Tannins (food grade), gallotannic acid, INS No. 181 DEFINITION DESCRIPTION

5. Which temperature is equal to +20 K? 1) 253ºC 2) 293ºC 3) 253 C 4) 293 C

PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative

Tamsulosin Hydrochloride Capsules

Experiment 8 - Double Displacement Reactions

Appendix 5 Overview of requirements in English

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Performance Assessment of EAGLE 5000 in Tobacco Smoke Environment. REPORT

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

BTU ANALYSIS USING A GAS CHROMATOGRAPH

Chemistry 51 Chapter 8 TYPES OF SOLUTIONS. A solution is a homogeneous mixture of two substances: a solute and a solvent.

(a) graph Y versus X (b) graph Y versus 1/X

Transfer of a USP method for prednisolone from normal phase HPLC to SFC using the Agilent 1260 Infinity Hybrid SFC/UHPLC System Saving time and costs

Ferda ORHUN Mineral Research and Exploration Institute of Turkey

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

Transformer Oil Gas Analysis

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

Short introduction into. Analytical Chemistry. by Prof. Dr. Manfred Sietz and Dr. Andreas Sonnenberg (PowerPoint slides)

NITRIC OXIDE and NITROGEN DIOXIDE 6014

ESSAY. Write your answer in the space provided or on a separate sheet of paper.

Specimen Paper. Time allowed! 60 minutes

[ Care and Use Manual ]

GOED VOLUNTARY MONOGRAPH (v. 4)

Absorption by atmospheric gases in the IR, visible and UV spectral regions.

Medical Gas Data Sheet (MGDS) 9% helium/35% oxygen/nitrogen medical gas mixture

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Laboratory procedures in polymer chemistry

@ Oxford Fajar Sdn. Bhd. ( T) Matter. 1.1 Atoms and Molecules 1.2 Mole Concept 1.3 Stoichiometry

Primary Level of Microscience Experiments for Grade 4 to 8 of Sudanese Schools

Unit 3 Notepack Chapter 7 Chemical Quantities Qualifier for Test

Natural Resources. Air and Water Resources

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Ces deux analyseurs permettent le contrôle de la qualité de l eau et des effluents.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Analytical Test Report

Public Assessment Report Scientific discussion. Amitriptylin Abcur (amitriptyline hydrochloride) Asp no :

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

VCE CHEMISTRY UNIT 2 Environmental Chemistry SAMPLE COURSE OUTLINE

MEMORANDUM GRADE 11. PHYSICAL SCIENCES: CHEMISTRY Paper 2

GC Troubleshooting 10. How to use this Troubleshooting Help system GC Troubleshooting - Top Level Generic problem descriptions...

ZINC ACETATE Draft proposal for The International Pharmacopoeia (August 2012)

Molecular Spectroscopy

Santa Monica College Chemistry 11

Flow Injection Analysis

Transcription:

Svensk läkemedelsstandard 2016.0 Carbon dioxide Postadress/Postal address: P.O. Box 26, SE-751 03 Uppsala, SWEDEN Besöksadress/Visiting address: Dag Hammarskjölds väg 42, Uppsala Telefon/Phone: +46 (0)18 17 46 00 Fax: +46 (0)18 54 85 66 Internet: www.lakemedelsverket.se E-mail: registrator@mpa.se

Ansvarig utgivare: Svenska farmakopékommittén Läkemedelsverket Box 26 S-751 03 Uppsala, Sweden Tel. 018/17 46 00 2(6)

CARBON DIOXIDE 1 Carbonei dioxidum CO 2 M r 44.01 [124-38-9] DEFINITION Content: minimum 99.5 per cent V/V of CO 2 in the gaseous phase. This monograph applies to carbon dioxide for medicinal use. CHARACTERS Appearance: colourless gas. Solubility: at 20 C and at a pressure of 101 kpa, 1 volume dissolves in about 1 volume of water. PRODUCTION Examine the gaseous phase. If the test is performed on a cylinder of gas, keep the cylinder of the substance to be examined at room temperature for not less than 6 h before carrying out the tests. Keep the cylinder in the vertical position with the outlet valve uppermost. Carbon monoxide. Gas chromatography (2.2.28). Gas to be examined. The substance to be examined. Reference gas. A mixture containing 5 ppm V/V of carbon monoxide R in nitrogen R1. Column: - material: stainless steel, - size: l = 2 m, Ø = 4 mm, - stationary phase: an appropriate molecular sieve for chromatography (0.5 nm). Carrier gas: helium for chromatography R. Flow rate: 60 ml/min. Temperature: - column: 50 C, - injection port and detector: 130 C. 1 Kapitlet är hämtat från Ph Eur 8th Ed för information. I händelse av tvist gäller alltid det vid tillfället giltiga kapitlet i Ph Eur. 3(6)

Detection: flame ionisation with methaniser. Injection: loop injector. Adjust the injected volumes and the operating conditions so that the height of the peak due to carbon monoxide in the chromatogram obtained with the reference gas is at least 35 per cent of the full scale of the recorder. Limit: - carbon monoxide: not more than the area of the corresponding peak in the chromatogram obtained with the reference gas (5 ppm V/V). Nitrogen monoxide and nitrogen dioxide: maximum 2 ppm V/V in total, determined using a chemiluminescence analyser (2.5.26). Gas to be examined. The substance to be examined. Reference gas (a). Carbon dioxide R1. Reference gas (b). A mixture containing 2 ppm V/V of nitrogen monoxide R in carbon dioxide R1 or in nitrogen R1. Calibrate the apparatus and set the sensitivity using reference gases (a) and (b). Measure the content of nitrogen monoxide and nitrogen dioxide in the gas to be examined. If nitrogen is used instead of carbon dioxide in reference gas (b), multiply the result obtained by the quenching correction factor in order to correct the quenching effect on the analyser response caused by the carbon dioxide matrix effect. The quenching correction factor is determined by applying a known reference mixture of nitrogen monoxide in carbon dioxide and comparing the actual content with the content indicated by the analyser which has been calibrated with a NO/N 2 reference mixture. Quenching correction factor = actual nitrogen monooxide content indicated nitrogen monooxide content Total sulphur: maximum 1 ppm V/V, determined using an ultraviolet fluorescence analyser after oxidation of the sulphur compounds by heating at 1000 C (Figure 0375.-1). The apparatus consists of the following: - a system generating ultraviolet radiation with a wavelength of 210 nm, made up of an ultraviolet lamp, a collimator, and a selective filter; the beam is blocked periodically by a chopper rotating at high speed, - a reaction chamber through which flows the previously filtered gas to be examined, - a system that detects radiation emitted at a wavelength of 350 nm, made up of a selective filter, a photomultiplier tube and an amplifier. 4(6)

Figure 0375.-1. UV Fluorescence Analyser Gas to be examined. The substance to be examined. Reference gas (a). Carbon dioxide R1. Reference gas (b). A mixture containing between 0.5 ppm V/V and 2 ppm V/V of hydrogen sulphide R1 in carbon dioxide R1. Calibrate the apparatus and set the sensitivity using reference gases (a) and (b). Pass the gas to be examined through a quartz oven heated to 1000 C. Oxygen R is circulated in the oven at a tenth of the flow rate of the gas to be examined. Measure the sulphur dioxide content in the gaseous mixture leaving the oven. Water: maximum 67 ppm V/V, determined using an electrolytic hygrometer (2.5.28). Assay. Infrared analyser (2.5.24). Gas to be examined. The substance to be examined. It must be filtered to avoid stray light phenomena. Reference gas (a). Carbon dioxide R1. Reference gas (b). A mixture containing 95.0 per cent V/V of carbon dioxide R1 and 5.0 per cent V/V of nitrogen R1. Calibrate the apparatus and set the sensitivity using reference gases (a) and (b). Measure the content of carbon dioxide in the gas to be examined. 5(6)

IDENTIFICATION First identification: A. Second identification: B, C. A. Infrared absorption spectrophotometry (2.2.24). Comparison: Ph. Eur. reference spectrum of carbon dioxide. B. Place a glowing splinter of wood in an atmosphere of the substance to be examined. It is extinguished. C. Pass a stream of the substance to be examined through barium hydroxide solution R. A white precipitate is formed which dissolves with effervescence in dilute acetic acid R. TESTS Examine the gaseous phase. If the test is performed on a cylinder of gas, keep the cylinder of the substance to be examined at room temperature for not less than 6 h before carrying out the tests. Keep the cylinder in the vertical position with the outlet valve uppermost. Carbon monoxide: maximum 5 ppm V/V, determined using a carbon monoxide detector tube (2.1.6). Hydrogen sulphide: maximum 1 ppm V/V, determined using a hydrogen sulphide detector tube (2.1.6). Nitrogen monoxide and nitrogen dioxide: maximum 2 ppm V/V in total, determined using a nitrogen monoxide and nitrogen dioxide detector tube (2.1.6). Sulphur dioxide: maximum 2 ppm V/V, determined using a sulphur dioxide detector tube (2.1.6). Water vapour: maximum 67 ppm V/V, determined using a water vapour detector tube (2.1.6). STORAGE Store liquefied under pressure in suitable containers complying with the legal regulations. IMPURITIES A. nitrogen monoxide, B. nitrogen dioxide, C. carbon monoxide, D. total sulphur, E. water. 6(6)