Fan Assisted Hydronic Radiators by Runtal QUICK GUIDE

Similar documents
Select Radiators Installation Guide

ELECTRIC CENTRAL HEATING FLOW BOILER

KONRAD. Hybrid Fancoil Series

Brochure EX

Radiant Comfort Warmth by Design

Condensing Boiler Efficiency

Solar Hot Water Heaters

ECOCIAT. Domestic hot water heat recovery unit

Installation and maintenance instructions. Danfoss Vent

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Making heating systems efficient and cost-effective: boilers, heating controls & more

Electric Flow Boiler

CHAPTER CONTENT PAGE. Hybrid: The perfect solution for all systems. Explanation of the - Heat Exchanger 4. Finishes 12

ASME Packaged Indirect Fired Water Heater

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

Laddomat Charging unit

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Light Duty Commercial Electric Water Heater

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Commercial Gas Furnace Upflow

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

HYDRONIC DESIGNER / INSTALLER MODULE DESCRIPTIONS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

VSO MAX HP High Flow Proportional Valve

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Cooling system components, removing and installing

COOLING SYSTEM Section Page

ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Float and Thermostatic Traps Series H, C and X

Operating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2

FOXAIR 60/50 ALL MODELS

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

Portable Air Conditioner

LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

Powers Controls TH 192 S Single Temperature Room Thermostat

CEILING CASSETTE FAN COIL UNIT

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Description of functions

User's Instructions. Alpha HE CB25/33 and HE SY25

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

ALL IN ONE. Heat Pump Water Heater

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL WH483 WH602. Contents. General Notes. Important. Description

INSTRUCTION FOR ASSEMBLY. 150x180 v Traditional sauna cabin

SURGICAL SCRUB SINKS INSTALATION-OPERATION-MAINTENANCE USER MANUAL

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Zenith Solar thermal 4.5m pump station Installation manual

Drayton Digistat +2RF/+3RF

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Installation, operation and maintenance manual TX 35A

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

RPV - RP - RA air handling units

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

Theta Dual service BFC, SGE, SGS for 20/30/40 kw heating capacity

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

HL Series - Commercial Heaters Tankless Water Heating Solutions

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

HERZ-Thermal Actuators

Ceramic Glass Electric Galley Ranges

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Versati Air to Water Heat Pump

Spare Parts List M96A.24SM/B M96A.28SM/B

Thermostatic bar showers. Troubleshooting and maintenance

Models: WA182, WA242. Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel.

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

SWIMMING POOL HEAT PUMP Owners Manual

Models: Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel. Blower Housing

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

Floor Heating Warehouse.co.uk

HVAC Processes. Lecture 7

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Builder Specifications for Solar Ready Homes

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

SERVICE SERVICE MANUAL FOR ALDE ELECTRICAL HEATER

SunMaxx Solar Filling Station Operating Instructions

Stainless Steel Single and Dual Circulation Kits

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Transcription:

Fan Assisted Hydronic Radiators by Runtal QUICK GUIDE

The radiator for today, tomorrow and beyond. NEO stands for New Energies Optimized TODAY The Runtal NEO combines the slim proportions and elegant lines of a Runtal panel with a low voltage fan assisted heat exchanger to provide a large heating capacity in a small compact unit. This unique design, coupling a radiant panel with small yet powerful 24 Volt fans and a heat exchanger, will quickly and efficiently heat a room with surprisingly quiet operation. TOMORROW The Runtal NEO is an elegant, efficient, and clean solution for providing comfort and style when using low temperature heating solutions of the future, such as heat pumps, solar-thermal systems, or condensing boilers. The Runtal NEO incorporates a washable filter into the design. This not only helps to maintain the operating efficiency over time, but also provides a level of cleanliness to the gently flowing air circulating within the room. The Runtal NEO is currently available in two heights (NEO 6 and NEO 8) each in four different lengths. NEO 6 The Runtal NEO comes standard in the Runtal 9010R White color, or may be available in a variety of Runtal optional colors at an additional cost. NEO 8 2 Runtal Radiators

OPERATION NEO OPERATION Adding a small coil and 24 Volt fans to the panel radiator yields a large heating capacity in a compact size, even when matched with a lower supply water temperature as found with water-to-water heat pumps, waste heat applications, solar heating, and condensing boilers. In mild conditions, the radiator can be operated without fans to create a soft radiant comfort. As conditions grow colder, three stages of fans boost the radiator s output to keep the space warm and comfortable, with nearly silent fan operation. A thermostatic radiator control valve is typically used to modulate the water flow into the radiator. Radiation + Convection = More Comfort in a Smaller Size Convection Radiation Room Air CONTROL PANEL The easy-to-use control panel on the top of the radiator controls the three speeds of the fans and will alert the user for filter cleaning and sensor defects. ON/OFF Button Fans Speed Selection Filter Alert (solid light) Defect Sensor (flashing) Operation Indicator Light NEO FILTER The Runtal NEO incorporates a 5 mm thick woven washable reticulated polyurethane filter which may be removed and cleaned as desired. Runtal Radiators 3

HEATING CAPACITIES 17.5 444 mm NEO 6 Transformer Plug Optional CAPACITY (BTUH/WATTS) NEO 6-800 104/40 529/155 1303/382 1614/473 1993/584 122/50 891/261 2013/590 2477/726 3020/885 Weight = 44.3 LBS. 140/60 1300/381 2743/804 3354/983 4057/1189 158/70 1740/510 3491/1023 4241/1243 5101/1495 NEO 6-1000 104/40 631/185 1945/570 2518/738 3207/940 122/50 1071/314 2955/866 3787/1110 4774/1399 Weight = 55.6 LBS. 140/60 1553/455 3979/1166 5060/1483 6330/1855 158/70 2075/608 5012/1469 6330/1855 7882/2310 NEO 6-1200 104/40 761/223 2334/684 3023/886 3849/1128 122/50 1283/376 3549/1040 4545/1332 5729/1679 Weight = 66.6 LBS. 140/60 1866/547 4777/1400 6070/1779 7599/2227 158/70 2491/730 6016/1763 7599/2227 9458/2772 NEO 6-1500 104/40 914/268 3030/888 4078/1195 5446/1596 122/50 1563/458 4559/1336 6053/1774 7971/2336 Weight = 80.7 LBS. 140/60 2283/669 6091/1785 8015/2349 10441/3060 158/70 3061/897 7974/2337 9960/2919 12874/3773 Output capacity based on a 68 F (20 C) Room Temperature 4 Runtal Radiators

HEATING CAPACITIES NEO 8 Transformer Plug Optional CAPACITY (BTUH/WATTS) NEO 8-800 104/40 788/231 1413/414 1709/501 2095/614 122/50 1334/391 2218/650 2655/778 3207/940 Weight = 52.3 LBS. 140/60 1948/571 3054/895 3631/1064 4344/1273 158/70 2610/765 3921/1149 4617/1353 5487/1608 NEO 8-1000 104/40 945/277 2109/618 2669/782 3375/989 122/50 1600/469 3255/954 4060/1190 5074/1487 Weight = 65.3 LBS. 140/60 2330/683 4429/1298 5473/1604 6776/1986 158/70 3115/913 5630/1650 6892/2020 8479/2485 NEO 8-1200 104/40 1133/332 2532/742 3201/938 4050/1187 122/50 1921/563 3907/1145 4876/1429 6087/1784 Weight = 78.5 LBS. 140/60 2980/820 5316/1558 6568/1925 8031/2383 158/70 3740/1096 6756/1980 8271/2424 10175/2982 NEO 8-1500 104/40 1361/399 3289/964 4320/1266 5732/1680 122/50 2337/685 5023/1472 6493/1903 8469/2482 Weight = 94.5 LBS. 140/60 3426/1004 6780/1987 8670/2541 11175/3275 158/70 4596/1347 8571/2512 10844/3178 13850/4059 Output capacity based on a 68 F (20 C) Room Temperature Runtal Radiators 5

PIPING OPTIONS Runtal NEO radiators can be ordered with either left hand or right hand piping configurations. The inlet and outlet sizes are ½ NPT female connections. Vent Vent 223 Piping Option 443 Piping Option P P 243 Piping Option 423 Piping Option OPTIONAL VALVE PACKAGE Many times thermostatic control valves are used to control the hot water flow into the NEO radiator. Runtal offers chrome valve sets, which include the thermostatic control valve and matching shutoff valve, to complete the sleek elegant look of the installation. Angle Pattern Chrome Valve Set Straight Pattern Chrome Valve Set ELECTRICAL CONNECTION The Runtal NEO radiator comes with a 24 Volt transformer plug to power the NEO fans, which is plugged into a standard 110 Volt outlet located adjacent to the NEO radiator. As an option for large projects, the Runtal NEO radiator can also be direct wired to a central 24 Volt electrical circuit system. 6 Runtal Radiators

1 MOUNTING 2 Step 1: Unscrew the wall mount plate from the back of the unit. Step 2: Rotate the lockdown clips at the bottom of the unit (as shown). 3 4 5 L / 2 L / 2 A Step 3: Mark the location for the unit on the wall, note that the wall mount plate should be fixed to wall studs or other solid backing. Step 4: Attach an appropriate wall mount fastener at the center of the wall mount plate to hold the plate to the wall. Step 5: Level the wall mount plate and then secure it with additional wall fasteners. Step 6: Hang the NEO unit to the wall mount bracket, then secure the unit with screws into the hold down clips. The unit is now ready for piping and electrical. 6 Runtal Radiators 7

TECHNICAL SAMPLE SPECIFICATION The hydronic fan assisted radiators shall be the Runtal NEO model as supplied by Runtal North America, Inc. The radiators shall consist of a panel radiator coupled with a fan powered heat exchanger, all in a complete one-piece unit. The radiator shall be capable of operating with the front radiant panel only (fans off), or with one of the three available fan speeds activated for greater output. The units shall be supplied with the models, lengths, and piping connection option as shown in the radiator schedule. The units shall include a wall mount plate for wall mounting and lock down clips for mounting security. Necessary wall support blocking for proper radiator mounting shall be by others. The units shall also include ½ female NPT pipe connections in one of four available configurations, a 24 Volt transformer plug for powering the unit fans, and a 5 mm thick woven washable reticulated polyurethane filter for incoming air filtration. The radiator finish shall be standard Runtal White powder coat finish for a total paint thickness of 2-3 mils. Other Runtal optional colors may be available at an additional cost. The radiator shall have a working pressure of 58.8 PSI, with a test pressure of 76.4 PSI. (OPTIONAL) Each radiator shall include a chrome plated valve set consisting of a ½ NPT non-electric thermostatic control valve and a companion ½ NPT shutoff valve, as supplied by the radiator manufacturer. Runtal North America, Inc. www.runtalnorthamerica.com PO Box 8278 187 Neck Road Ward Hill, MA 01835 TEL: 800-526-2621 FAX: 978-372-7140 In Canada: 888-829-4901