User s Information Manual

Similar documents
SL280UHV SERIES GAS FURNACE WARNING

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Tankless Water Heater

USER S INFORMATION MANUAL

Your safety and the safety of others are very important.

Operator: Save these instructions for future use!

CARING FOR YOUR WATER HEATER

GALAXY. High performance gas boilers HOT WATER AND STEAM NATURAL AND L.P. PROPANE GASES

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Baxi Combi 80e & 105e

Boiler and Burner Cleaning and Servicing Specifications

WARNING: IMPROPER SERVICING AND START-UP OF THIS EQUIPMENT MAY CREATE A POTENTIAL HAZARD TO EQUIPMENT AND TO OPERATORS OR PERSONS IN THE BUILDING.

NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.

Preventing Overheated Boiler Incidents

Boiler Preparation, Start-Up and Shutdown

High efficiency, cast-iron gas boiler

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Energy Saving Fact Sheet Boilers

INSTALLATION INSTRUCTIONS

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

GAS-FIRED WATER HEATER

Safe Method: Gas Safety in Catering Establishments

Energy Efficient Operations and Maintenance Strategies for Boilers

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: Natural Gas

Gas-Fired, Residential Storage Type Water Heaters

Fuels Safety Program FS DIRECTOR S PUBLIC SAFETY ORDER

Routine and Emergency Boiler Operation

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

Operating Instructions & User s Information Manual VITODENS 100-W WARNING. IMPORTANT Read and save these instructions for future reference.

Instruction Manual for Residential Manufactured Home Gas Water Heaters

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Water Heaters. Residential 30, 40 and 50 Gallon

Factory owners must ensure the boiler is:

INSTALLATION INSTRUCTIONS

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

RESIDENTIAL GAS-FIRED WATER HEATERS OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS


Instruction Manual for Residential Gas Water Heaters

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

Bradlee Boilers Ltd. Instruction Manual for starting up Bradlee Hire Boiler from Cold

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

Installation and Service Instructions LoganoUS/CA GC 144 II

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

For installation guide see reverse of book

/2010 US/CA

COMMERCIAL GAS WATER HEATER Glass-Lined Tank-Type Water Heater

Operating instructions

OPERATING, INSTALLATION AND SERVICE MANUAL

PLP - TERMS AND CONDITIONS

Instantaneous gas water heater

User's Instructions. Alpha HE CB25/33 and HE SY25

Consortiwm Awdurdodau Lleol Cymru Consortium Local Authorities Wales

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

User Guide and Important Warranty Information. Heatmax Combi HE Range. Condensing Combination Boiler

orlando OWNER S MANUAL

Owner s Manual 58HDX UPFLOW / HORIZONTAL / DOWNFLOW HIGH EFFICIENCY GAS FURNACE. ama ! WARNING SAFETY CONSIDERATIONS

SERVICE MANUAL. Flammable Vapor Ignition Resistant Water Heaters. Gas Water Heaters. Troubleshooting Guide and Instructions for Service

37E73A-903 & 906 INTELLI-VENT

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series:

Maintaining Conventional Residential Oil-Fired Heating Systems

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

PURCHASED. IF YOU ARE UNSUCCESSFUL, PLEASE WRITE TO THE COMPANY LISTED ON THE RATING PLATE ON THE WATER HEATER.

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book


GAS-FIRED COMMERCIAL WATER HEATER

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

INSTALLATION INSTRUCTIONS

Operating Instructions & User s Information Manual VITODENS 100-W WARNING WARNING IMPORTANT. Read and save these instructions for future reference.

GAS SAFETY PRECAUTIONS

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

TOBY DVR5 OIL CONTROL & SAFETY VALVE

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

PC1131 Electric Air Compressor

RESIDENTIAL GAS WATER HEATERS

Product and Safety Information... 2,3 Service and Maintenance Munchkin Operation Primary Water

For the owner. Instructions for use. ecotec. Wall hung room sealed fan assisted condensing boilers

PURCHASED. IF YOU ARE UNSUCCESSFUL, PLEASE WRITE TO THE COMPANY LISTED ON THE RATING PLATE ON THE WATER HEATER.

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

TWO BURNER PROPANE CAMPING STOVE

2010 Residential Water Heater Replacement Check List

San josé OWNER S MANUAL

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

Duo-tec Combi HE A Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

ASK THE EXPERT: Burner Troubleshooting Information & Maintenance

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Some Criteria for Choosing a Steam Boiler for a Microbrewery

THREE. Heating and Cooling

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

Electric & Gas Water Heaters

K6C Summit Multi Oil Warm Air Furnace SAVE THESE AND BURNER INSTRUCTIONS FOR REFERENCE

Transcription:

User s Information Manual Galaxy GG, GX, GXH & GXHA Series, Sentry S/SX Series and Sentinel SE Series Gas Boilers with Continuous Pilot FOR YOUR SAFETY: Before operating this boiler, READ this manual. DO NOT attempt to install, service or repair this boiler yourself. There are no user serviceable parts. Contact a qualified service agency if your boiler needs repair or maintenance. Ask your gas supplier for a list of qualified service agencies. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS DO NOT try to light any appliance. DO NOT touch any electrical switch; DO NOT use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. DO NOT use this boiler if any part has been underwater. Immediately call a qualified service technician to inspect the boiler and to replace any part of the control system and any gas control which has been underwater. WARNING Should overheating occur or the gas supply fail to shut off, DO NOT turn off or disconnect the electric supply to the circulator pump. Instead, shut off the gas supply at a location EXTERNAL to the appliance. If your boiler is purchased with or will be equipped with an automatic vent damper, make certain that the damper is installed and wired by a qualified installer who has been certified by your local gas utility. See Vent Dampers page 7. Keep the boiler area clean and free of all materials that can burn. Never close or reduce openings that supply air for the boiler combustion and for ventilation. Printed in U.S.A. 1111 PUBLICATION NO. GS-UIM-CBP Part No. 41-1824

SENTRY S SERIES HOT WATER BOILER WITH INTEGRAL DRAFT DIVERTER Figure 1. Location and identification of parts Figure 2. Burners Pilot Burner Access Door Front and Right End View Models S-60 thru S-150 Base Assembly Gas Valve * Vent damper may be installed horizontally on all models with use of a common vent elbow. See lighting instructions on pages 7-8. 2

SENTINEL SE SERIES and SENTRY SX SERIES HOT WATER BOILER WITH EXTERNAL DRAFT HOOD Location and identification of parts Figure 9. Figure 10. Burners Pilot Burner Access Door Base Assembly Gas Valve Front and Right End View MODELS SX-150 to SX-210 and SE-70 to SE-245 * Vent damper may be installed horizontally on all models with use of a common vent elbow. See lighting instructions on pages 7-8. 3

GALAXY GG/GX GXHA SERIES HOT WATER AND STEAM BOILER Figure 14. Location and identification of parts Name and Rating Plate Lighting Instructions (inside front panel) Jacket Top Relief Valve Temperature and Pressure Gauge Gas Valve Burner Access Door Burners Gas Manifold Figure 15. Pop Safety Valve Pressure Gauge Jacket Top Figure 17. Front Panel Figure 16 GXHA Series Steam Boiler Pop Safety Valve Pressure Gauge Jacket Top Easy access front panel on standard extended jacket, is removed by simply pressing hand against panel and pushing up. See lighting instructions on page 8. 4

Inspection, cleaning, repair Chimney, flue pipe and boiler Your boiler and heating system will last an indefinitely long time at full efficiency, if it is inspected regularly and is kept in good repair and adjustment. You, the user, should make regular inspections, and report any problems to your service agency. At regular intervals, you should have that agency inspect the system, and clean the boiler and make repairs and adjustments as necessary. What you and the service agency should do are listed below. Contact your gas supplier for a list of qualified service and repair agencies. User inspection At least once each month during the heating season and once just before cold weather starts: (1) Look closely at the smokepipe and draft hood (see Figure 18, 19 & 20). Make sure pipe joints are snug and are fastened with screws. Cement at the chimney joint should fill the joint and should not leak air. There should be no visible signs of rust (corrosion) or salts from water evaporation. (2) Look at all water (or steam) piping. There should be no leaks or signs of leaks at any pipe joints or around the boiler. Drain valves, other valves, and the relief valve (or steam safety valve) should not drip or leak. (3A) On water boilers: The temperature and pressure gauge indicates the pressure in the boiler at each water temperature. For most installations, it should indicate about 12 to 15 psi pressure when temperature is about 70 to 100 degrees F, and from 15 psi to 25 psi when temperature is up to 240 degrees F. FOR YOUR SYS- TEM, there is one correct pressure for each temperature. ASK YOUR INSTALLER OR SERVICEPER- SON TO EXPLAIN AND SHOW YOU. Learn what normal pressures to look for. If pressure decreases from normal, your system is losing water. If pressure rises from normal, the relief valve will open to relieve the pressure. Call your service organization if pressures are higher or lower than normal, and if the relief valve spills water. Repair or adjustment is needed. (3B) On steam boilers: (a) The water level in the gauge glass must be kept constant. You must have your installer or service organization explain to you how water is added to maintain water level. (b) Most boiler models are equipped with float type low water cutoff. You must be familiar with this LOW WATER CUT- OFF, how it works and HOW TO BLOW IT DOWN. Instructions are supplied with it. Ask your service organization to explain and show you blowdown. The cutoff should be blown down three times the first week and should be blown down weekly thereafter. Maintenance of the low water cutoff is vital in protecting your steam boiler against breakage due to loss of water. If your boiler is equipped with an electronic probe type low water cutoff, it requires periodic testing. Ask your service agency to test this low water cutoff twice a year. (4) Study the labels attached to your boiler, especially the LIGHTING AND SHUTDOWN instructions. Have your installer or service organization show you how to start and shut down the boiler following those instructions. The lighting instructions on your boiler are also reproduced, with pictures, in this manual. (5) Stand near the boiler, look and listen. As the burners start and shut off, there should be no unusual noise. No fire should be visible coming out of the front when the burners start or run. (6) Ample air is required for your boiler to burn fuel cleanly and safely. Check to make sure the openings provided in your house are not closed and are not obstructed. This is most important in colder weather, when most air is needed. Figure 18. (Galaxy GG, GX, GXH, Sentinel SE, Sentry SX boilers) Figure 19. Figure 20. 5

Figure 21. (7) If equipped with vent damper, which can ONLY be installed on boilers equipped with 24 volt gas valve: (a) Your vent damper must be OPEN when the boiler is operating (BURNERS ARE ON). Ask your installer or serviceperson to show you the vent damper position indicator, indicating the open and closed damper positions. Inspect for proper operation monthly. If damper position indicator indicates that the damper is closed when the boiler is operating, SHUTDOWN the boiler immediately and call your service agency. (b) This device must be installed and inspected annually by a qualified installer in accordance with the Slant/Fin vent damper installation instructions. If improperly installed, a hazardous condition such as explosion or carbon monoxide poisoning could result. If installed improperly, all vent damper and boiler warranties shall be voided. If you find during your inspection any unusual noise, water leak, corroded smokepipe, abnormal water pressure or flame rollout, call for service immediately. SERVICE INSPECTION The selected service organization should make these inspections, preferably once each year, before the cold weather begins: (1) Make the checks for leaks, corrosion, noise, flame, heat and outside air supply described under User s Inspection. (2) Check safety operation of the HIGH LIMIT CON- TROL (and, for steam boilers, the LOW WATER CUTOFF) and GAS VALVE. If the boiler is equipped with an automatic vent damper, check this device for safe and automatic operation. (3) Check gas input rate, by clocking the gas meter. Inspect burner flame. Clean and adjust burners and adjust gas rate as required. (4) Disconnect flue pipe from draft hood. Remove draft hood and inspect boiler heating surface below. If any soot, scale or rust is visible, clean the boiler as described in the next section. (5) Replace any corroded smokepipe. Repair or replace other devices as found necessary. Check and adjust for normal operation. Explain to the user what was done and what to look for to prevent future problems. CLEANING BOILER, SMOKEPIPE, CHIMNEY (See Figure 21). If necessary as indicated in (4) of Service Inspection section, the selected service organization should clean the boiler as follows: (1) Shut off electric power and gas supply. (2) Disconnect smokepipe and remove draft hood. (3) Remove jacket top panel. Remove flue cover from boiler. (4) Remove access door and remove burners, or place cover over burners for dirt protection. (5) Brush down boiler flues to bare metal. Clean all debris from bottom of boiler after brushing. Clean burner slots, if necessary. (6) Replace flue cover and seal with furnace cement. Replace burners if removed. Replace access door. (7) Inspect draft hood and smokepipe. If corroded, replace. If soot or deposits from condensation are found, clean out, and inspect inside of chimney for soot or other deposits. Clean if necessary. (8) Reconnect hood and flue pipe and fasten and seal all joints. Turn on gas and electric power. (9) Check boiler performance after cleaning, and adjust as necessary. NOTE: Condensate (water), rust, scale and soot are not found in the boiler or smokepipe of normally operating system. If any of these is found, eliminate the cause. The most likely cause of condensate and corrosion or soot is (a) restricted air supply, or (b) a faulty chimney. 6

VENT DAMPERS A Slant/Fin vent damper is available only as part of a Slant/Fin gas boiler package equipped with a 24 volt gas valve. This vent damper is design certified by A.G.A. for use only on specific Slant/Fin Corporation gas boiler models. These boilers will be equipped with a plate which states that the boiler may be used with a Slant/Fin Corp. automatic vent damper device and indicates the proper vent damper model number. OTHER VENT DAMPER OR DEVICES WITH SIMILAR PURPOSE ARE NOT PERMITTED. WITH ANY VENT DAMPER OR PILOT SYSTEM (a) DO NOT attempt to install or adjust or service it yourself. (b) Make certain that the installation is approved by your local gas utility. SAFETY AND LIGHTING INSTRUCTIONS FOR IGNITION SYSTEMS EQUIPPED WITH GAS VALVES VR8200 AND VR8300 SAFETY INFORMATION For Your Safety Read Before Lighting WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. Figure 22. Continuous (Standing) Pilot Ignition System IGNITION SYSTEM CONTINUOUS BURNING (STANDING) PILOT Your gas boiler is equipped with the Honeywell VR8200 or VR8300 gas valves. See Safety and Lighting Instructions on pages 7 and 8 and Figure 22. WARNING Should overheating occur or the gas supply fail to shut off, DO NOT turn off or disconnect the electric supply to the circulator pump. Instead, shut off the gas supply at a location EXTERNAL to the appliance. 7

B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS DO NOT try to light any appliance. DO NOT touch any electric switch; DO NOT use any phone in your building. Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. NEVER use tools. If the knob will not push in or turn by hand, DON T try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. DO NOT use this appliance if any part has been underwater. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been underwater. LIGHTING INSTRUCTIONS 1. STOP! Read the safety information on page 7 and above. 2. Set the thermostat to lowest setting. 3. Turn off all electrical power to the appliance. 4. Remove control access panel. (Galaxy models only.) 5. Turn gas control knob clockwise to OFF. 6. Wait five (5) minutes (longer for propane) to clear out any gas, then smell for gas, including near the floor. If you then smell gas STOP! Follow B in the safety information above on this page, if you don t smell gas, go to next step. 7. Remove the pilot access panel located below and behind the gas control unit. 8. Find pilot, follow metal tube from gas control. The pilot is between two burner tubes behind the pilot access panel. 9. Turn knob on gas control counterclockwise to PILOT. 10. Push in red button all the way and hold in. Immediately light the pilot with a match. Continue to hold the red button in for about one (1) minute after the pilot is lit. Release button and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 10. If button does not pop up when released, stop and immediately call your service technician or gas supplier. If the pilot will not stay lit after several tries, turn the gas control knob to OFF and call your service technician or gas supplier. 11. Replace pilot access panel. 12. Turn gas control knob counterclockwise to ON. 13. Replace control access panel. (Galaxy models only.) 14. Turn on all electric power to the appliance. 15. Set thermostat to desired setting. TO TURN OFF GAS TO APPLIANCE 1. Set the thermostat to lowest setting. 2. Turn off all electric power to the appliance, if service is to be performed. 3. Remove control access panel. (Galaxy models only.) 4. Turn gas control knob clockwise to OFF. DO NOT force. 5. Replace control access panel. (Galaxy models only.) These boilers are equipped with both a blocked vent safety switch and a rollout safety switch. The blocked vent safety switch is located on the draft hood flue stack. This is a manual reset control used to prevent excessive spillage of flue gases from the draft hood. The rollout safety switch is a single use (one time) thermal fuse to prevent the boiler from operation if flue passages are blocked. If either of these devices operate to shut down the burners, follow instructions in the section To Turn Off Gas To Appliance and call your service technician or gas supplier. Slant/Fin Corp. 2011. SLANT/FIN CORPORATION, Greenvale, N.Y. 11548 Phone: (516) 484-2600 FAX: (516) 484-5921 Canada: Slant/Fin LTD/LTEE, Mississauga, Ontario www.slantfin.com