Application of ANSYS in the Simulation of IEC Type Tests Applied to Low and Medium Voltage Switchboards



Similar documents
Overview. also give you an idea of ANSYS capabilities. In this chapter, we will define Finite Element Analysis and. Topics covered: B.

Changing industry standards: friend or foe?

21 st Century Facilities

Simulation Technology to Support the Design of Electric Distribution and Control Devices

Unified requirements for systems with voltages above 1 kv up to 15 kv

The Intelligent AX1 Switchgear for Medium Voltage

INTERACTION OF LIQUID MOTION ON MOBILE TANK STRUCTURE

ABB Fuses Competitive Advantages

Carbon Cable. Sergio Rubio Carles Paul Albert Monte

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

Secondary Unit Substations

A Comparison of Contemporary Electrical Distribution Equipment Standards. San Francisco IEEE Industry Applications Society May 26, 2009

New Arc Resistant, Compact Metal Clad Switchgear: Meeting ANSI / UL Design Challenges By Ashok Kulkarni and Predrag Milovac

Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow

C I R E D 21 st International Conference on Electricity Distribution Frankfurt, 6-9 June 2011

FAQs-Main switchboard design criteria

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

MV vacuum circuit breaker Evolis. When trust guides your steps

Comparative study for cables and busbars

Thermal Analysis, Heat Sink Design and Performance Verification for GE Fanuc Intelligent Platform s WANic 3860 Packet Processor PCI Card

THREE-DIMENSIONAL INSERT MOLDING SIMULATION IN INJECTION MOLDING

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

The easy way to build switchgear and controlgear assemblies in compliance with the regulations

Power Monitoring for Modern Data Centers

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

SOLIDWORKS SIMULATION GET DESIGN INSIGHTS TO DRIVE MARKET WINNING INNOVATION

Simulation Techniques for Tablet and Mobile Phone Design Bill McGinn; Ansys Senior Application Engineer

Contents. Description. Product Selection Guide

Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

How To Choose A Transformer

Intertek Cleeve Road, Leatherhead, Surrey KT22 7SB UK

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Dynamic Process Modeling. Process Dynamics and Control

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

MEM23131A Evaluate rapid prototyping applications

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

Low Voltage Switchgear MNS is with MSpeed

Reliability requires consulting engineers and end users to grasp design, maintenance basics. By Reza Tajali, P.E. Square D Power Systems Engineering

Part 1 System Modeling & Studies for Existing Systems

Session Four: Internal Arc Safety in New and Existing Switchgear

SAFETY ALERT SWITCHBOARD INTERNAL SEGREGATION AND IP RATING. May 2014 BACKGROUND

Which switchboards equip your building facilities for the future?

Customer Training Material. Lecture 4. Meshing in Mechanical. Mechanical. ANSYS, Inc. Proprietary 2010 ANSYS, Inc. All rights reserved.

MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV

How To Select A Solid State Relay For A Three Phase Resistive Load

Fraunhofer Project Group

TWENTIES WORKSHOP, EWEA 2012 Unveiling the future energy system: full scale demonstrations to reach 2020 targets. 17th April 2012

Modeling and Analysis of DC Link Bus Capacitor and Inductor Heating Effect on AC Drives (Part I)

ABB Inc. April 19, 2011 Slide 1

Training Systems for Technical Education Product Overview. Education

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Lightning current simulation in the laboratory - parameters, procedures and test equipment -

Teknia Group. Corporate Video. Teknia is a Spanish family owned company. The group consists of two business units: Automotive and Technologies

Graduate Courses in Mechanical Engineering

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

Materials. Testing Software Data Infrastructure

Module 1 : Conduction. Lecture 5 : 1D conduction example problems. 2D conduction

Defining the Needs of Modern Data Center Power Systems, Low Voltage Circuit Breaker Application

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Following are definitions for major parameters to consider when selecting a power line polarity protection diode for an automotive application.

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

Simulation Analysis Optimisation. Computer Aided Engineering

Perspective on R&D Needs for Gas Turbine Power Generation

Release: 1. UEE62111 Advanced Diploma of Engineering Technology - Electrical

However, industrial applications may utilize a relay, which short-circuits the ICL path after the inrush sequence.

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

TEC 327 Electronic Devices Lab (1) Corequisite: TEC 326. Three hours lab per week. Experiments involving basic electronic devices.

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

AS/NZS 3000:2007 Amendment 2

Electric Process Heaters & Engineered Systems

Motor-CAD Software for Thermal Analysis of Electrical Motors - Links to Electromagnetic and Drive Simulation Models

CFD Analysis of a butterfly valve in a compressible fluid

Faster Parts. Your Way. Xcentric Mold & Engineering. All rights reserved

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

UNL71 Physics Neil Lister; BSc, Dip, Ed.

DEVICES OF PROTECTION AND COMMAND

EVERGREEN (C.P.) USA INC. TEL: (650) FAX: (650) SPECIFICATIONS Lithium Battery CR123A- 1700mAh

Choosing for tranquility

18 Q0 a speed of 45.0 m/s away from a moving car. If the car is 8 Q0 moving towards the ambulance with a speed of 15.0 m/s, what Q0 frequency does a

Arc Terminator Active Arc-Resistant Switchgear

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

UFES Active protection for switchgear

Unit 2 Lesson 1 Introduction to Energy. Copyright Houghton Mifflin Harcourt Publishing Company

13. Electrical network design methodology and application example

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

Fusible Disconnect Switch

>> System CRD14-System JTD1 /

Titelmasterformat durch Klicken bearbeiten

Current Limiting Power Resistors for High-Power LED Module Lighting Applications

STRATO LED Drivers 70W, Single output

Transcription:

Application of ANSYS in the Simulation of IEC Type Tests Applied to Low and Medium Voltage Switchboards

MSO INDUSTRIAL Soluciones Avanzadas de Ingeniería MSO Industrial offers Specialized technical advice for the optimization of industrial processes and manufactured products with the use of Computer Assisted Engineering (CAE) Our capabilities are based in four core competences: Thermal and Structural optimization. Multyphisics analysis. Rational use of energy. Applied research and development

SERVICES: CONSULTANCY SERVICES PRODUCT DEVELOPMENT -Structural -Thermal -Fluid dynamics -Electrodynamics -Optimization -Concurrent engineering -Functional analysis -Design for assembly / manufacturability -Quality analysis -AMFE / QFD RATIONAL USE OF ENERGY INTEGRAL SIMULATION TOOLS SUPPLY ISO 50001: 2010 -Energy managment -Continuous improvement -Thermal optimization -Transversal or particular evaluation. -Software supply -Support -Training -Project development

PROBLEM DESCRIPTION The IEC requieres type test for temperature rise, short circuit and arc flash for low and medium voltage switchgears and controlgears. In Colombia there are no labs with the required capacity to execute this kind of test. This restriction adds limitations to certifications process, increasing time and costs for the development of new products. Common costs of type tests 2 Prototypes: U$ ~12.000 Logistics: U$ ~3.000 Labs tests: U$ ~40.000 TOTAL AVE: U$ ~ 55.000 Time for Results: 3 Months (In best case)

OBJECTIVES Verify by means of simulation the accordancy of switchgears and controlgears, during IEC type test for temperature rise, short circuit and arc flash. Increase the likelihood of success of the switchboards during the execution of type tests in the labs. Speed up the development and certification process of colombian manufacturers of switchboards. Decrease the cost of development of new products.

METHODOLOGY - General Based on the requirements of the IEC standards, a comparative analysis is made between the expected results and the simulated results.

METHODOLOGY Short Circuit type test IEC-60865 Reference standars IEC-60439 1 and 2 Num 7.5 / NTC 3475 IEC 62271 Num 6.6 / NTC-3309 Applied physics (ANSYS Modules) Electromagnetic (steady or transient): Joule effect. Thermal (steady or transient): Heat transfer coefficient, Temperature field. Structural (static or transient): Non Linear materials, thermal deformations.

AFTER TEST BEFORE METHODOLOGY Short Circuit type test NORMATIVE REQUIREMENTS SIMULATION VERIFICATION Normal operating conditions Normal operating conditions TEST Representative prototype3d CAD Controlled conditions No variation in conditions (Ideal conditions) Structural No plastic deformations Electrical Thermal No way to evaluate this now No metal melting or softening temperature

METHODOLOGY- Temperature rise Reference standars IEC-60439 1 & 2 Num 7.5 IEC 62271 Num 6.5 Applied physics (ANSYS Modules) Electromagnetic (steady): Joule effect. Thermal (steady): Temperature field in busbars and panels. CFD (steady): Heat transfer coefficient calculation.

AFTER TEST BEFORE METHODOLOGY- Temperature rise NORMATIVE REQUIREMENTS SIMULATION VERIFICATION Normal operating conditions Normal operating conditions Controlled conditions TEST Representative prototype3d CAD Structural Thermal No variation in conditions (Ideal conditions) N/A No temperature limit violation Electric Efficiency and power loss

METHODOLOGY- Arc Flash (Over-presure and gas evacuation) Reference standars. IEC-60439 1 and 2 Num 7.5 / NTC 3475 IEC 62271 Num 6.5 / NTC 3309 Applied physics (ANSYS Modules) Electromagnetic (transient): Joule effect. Thermal (transient): Temperature field in busbars and panels. Structural (Steady or transient): Deformations due to pressure wave. CFD (transient): Heat transfer coefficient calculation, gas evacuation simulation.

AFTER TEST BEFORE METHODOLOGY- Arc Flash (Over-presure) NORMATIVE REQUIREMENTS SIMULATION VERIFICATION Normal operating conditions Normal operating conditions TEST Representative prototype3d CAD Controlled conditions No variation in conditions (Ideal conditions) Structural No debris after detonation Thermal Electric Fluids No temperature limit violation Efficiency and power loss Gas evacuation and pressure wave values

ACHIEVEMENTS Improvement of the development process of new products for the electrical sector industries, faster and confident. Open discussion between the manufacturers and regulators about the opportunities, risks and benefits of simulation in the development of new products. Collaborative work with certification entities and local manufacturers of electrical products.

CONCLUSIONS It is possible to simulate the three type test shown here getting deeper results before real lab tests. It is necessary to standardize this process in order to facilitate the evaluation of results. It is necessary to involve the regulation bodies in the definition of the scope of the simulation of IEC type tests.

NEXT STEPS Implementation CFD models for the evacuation of gas during arc flash events. Validation of the results with primary source data for the three types of tests (currently we use secondary source). Implementation of the procedure as a design by analysis tool (i.e. ASME Section VIII div 3). Project for Colombian the electric cluster.