UL330 ULTRASONIC FLOWMETER CLAMP-ON TYPE OUTLINE FEATURES MEASUREMENT PRINCIPLE

Similar documents
WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

How To Use A Flowmeter

How To Read A Pipe From A Sensor

Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Detection of Pipe Leaks Connection of Pulse Monitoring System in Thermal Utilities

Digital inductive conductivity transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Series DFMT Digital Paddlewheel Flowmeter

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Open Channel & Partially Filled Pipe Ultrasonic Flow Meters

For Multi-Parameter Meters see mvx

COMBIMASS. Technical Data COMBIMASS eco-bio +

O C M III. Open Channel Flow Monitor

RY2 miniature industrial relays

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

ENAiKOON ultrasonic fuel-level sensor

T0118 T2118 T3118. Instruction Manual

Duct Humidity Transmitter

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

HYDRUS ULTRASONIC METER

Radiant Temperature Sensor TY7321

Instruction Manual. T3111 T3111L T3111P T3111Ex

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Cross-beam scanning system to detect slim objects. 100 mm in

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

LCD Readout Digital Pressure Switch

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Open channel & partially filled pipe Ultrasonic flow meters

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.

2.24. Pump Controller 704. Data Sheet

TMS TANK MANAGEMENT SYSTEM

HERZ-Thermal Actuators

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Adjustment functions for both span and shift have been incorporated

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Electromagnetic Flow Meter

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Contents. Document information

Differential Charge Amplifier

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Operation Manual For NDJ-8S Digital Rotary Viscometer

SELECTION, APPLICATION AND MAINTENANCE

NC-12 Modbus Application

Product Discontinuation Notices

Control Devices Catalogue. Control Devices. Preferred and Standard Products

PORTAFLOW 300. Ultrasonic Flowmeter Manual

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Plastic tube flowmeters Series PT/PS

Electronic Control Devices The European Product Catalogue 2007

Centro-Matic Automatic Lubrication Systems System Controls

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

T U R B I N E G A S M E T E R

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

EBDSPIR-PRM, EBDSPIR-PRM-IP

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Solid-State Timer H3G

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

PIEZOMETER AIRFLOW MEASURING RING

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

W150: Miniature photoelectric switch series with completely integrated electronics

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

FLOW SYSTEM flow measurement system in open channels and non-pressurized pipes

SITRANS F M MAGFLO. Electromagnetic flowmeters Signal converter types MAG 5000, MAG Manual *083R9141* Order no.

TC-9102 Series Surface Mount Temperature Controllers

Series 510 Submersible Level Transmitters

Introduction to Fiber Optic Cables. Photoelectric Sensors. 2Photoelectric Sensors, Standard Sensors, Fiber optic cables. Please Note!

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

3 Port Solenoid Valve

4 Posiflow Proportional Solenoid Valves

DigitalFlow GF868 Panametrics Ultrasonic Flare Gas Mass Flowmeter. GE Sensing. Features. Applications

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

How To Use A Ds340 (Dsp)

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

Chapter2. Installation

Transcription:

CLAMP-ON TYPE UL330 ULTRASONIC FLOWMETER OUTLINE Our clamp-on type Ultrasonic Flowmeter UL330 is Time-Flight type flowmeter and capable of measuring a flow rate of metallic and plastic piping ranging from to 400 mm in nominal diameter. A detector (an ultrasonic sensor) is mounted outside an existing piping by clamping method, so that it does not get into contact with the measuring fluid at all, and there are no concerns about the mixture of solid material and metallic ion into the fluid, the corrosion of sensor by chemical, and the pressure loss by installing the flowmeter. FEATURES The sensor of ultrasonic flowmeter UL330 is clamped on just outside of an existing pipe without any piping modification and time consuming installation work. By adopting a DSP and an AD converters, the flow measurement has been speeded up, and the resistance to bubbles has been improved. Because of the noncontact measurement method, the formation of bubbles and the mixture of metallic ion have been completely prevented. Installing the flowmeter does not cause the pressure loss because of no obstacles in the measuring pipe. The ultrasonic flowmeter is not affected by the pressure or conductivity of fluids. Excellent in long-term stability because of no moving part. Providing the following functions: Forward/backward flow rate display, totalizing display, analog output, pulse output, status output. MEASUREMENT PRINCIPLE As shown in Fig., when the ultrasonic wave is propagated in the fluid in ψ angle, there is the difference in propagation time between A to B and the reverse direction. The propagation time for each direction is calculated by the following formula. t AB = L /VAB = L / (Co +Vm cos ψ ) t BA = L /VBA = L / (Co Vm cos ψ ) L :Distance between A and B Vm Co t AB, t BA :Average fluid velocity : Ultrasonic propagation velocity in resting state of fluid : Ultrasonic propagation time between A to B and B to A VAB, VBA : Ultrasonic propagation velocity A to B and B to A. ψ : Propagation angle of the ultrasonic wave The average fluid velocity (Vm) can be calculated by measuring the difference in the propagation time as follows: Vm cos ψ = L / t AB L / t BA = L ( t BA t AB ) / ( t BA t AB ) Vm = L ( t BA t AB ) / ( cos ψ t BA t AB ) Since the distance (L) between A to B and the angle ψ are known, the average fluid velocity (Vm) can be calculated. The flow rate can be calculated from the above Vm and the cross-sectional area of pipe, displayed and outputted. A B VBA L ψ VAB Vm Fig. Measurement Principle

STANDARD SPECIFICATIONS Measuring method : Ultrasonic time-flight type (Ultrasonic path: Reflex mode / V path or Diagonal mode / Z path) Construction : Sensor, Converter, Exclusive coaxial cable with BNC connector, sensor fixing rail Sensor mounting : Piping clamp-on type Measuring fluid : Whole fluids, but excluding liquids containing high viscosity fluid, a lot of bubbles, and slurry Measurable fluid sonic velocity range :,000 to,0 m/s Measurable fluid kinematic viscosity range : 0.30 to 40.00 mm /s Fluid temperature : Up to 90 C (Surface temperature of piping) Measurable pipe (Nominal diameter) : mm (min) to 400mm (max) Refer to Table for Sensor Selection and Mounting Method. Note : The flowmeter is not applicable for lined piping. Measurable flow velocity range :0 to 0m/s Settable full scale flow velocity range : Minimum 0.3m/s to maximum 0m/s Accuracy : % of the reading at the condition that flow velocity is m/s or more and Reynolds number is 00 or more. : Flow velocity error is cm/s at the condition that flow velocity is less than m/s. Display : 6-digit, -line alphanumeric LCD (with backlight) and status display LEDs (3 pieces) Display data : Flow rate, totalizing flow rate, various status Power supply : to 40VAC /60Hz ( 85 to 64VAC /60Hz is acceptable) Power consumption Cable entry : VA or less : For power/output (M0 x.5, 3 pieces); With waterproof cable gland (Applicable cable diameter: ø8.0 to ø3.0) For sensor; Waterproof BNC connector ( pieces) Outputs ) Analog output : 4 to 0 ma DC, Load resistance: 0Ω or less ) Pulse output : Open collector output Load rating 30 V DC, ma, Low level V or less Pulse width: 0.5 ms (max.0pps), ms (max.0pps), ms (max.5pps), 0ms (max.pps), s (0.5pps or less): It is selected by the number of the maximum setting pulses. 3) Status output : Open collector output Load rating 30VDC, ma, Low level V or less Status : Hold output Status : Empty pipe detection Status 3 : Forward or backward flow detection Damping setting : 0 to s (Settable in increments of s step) * Valid for display, analog output and pulse output. There is a response delay of 0.5 s, even if damping is set to 0 s. Low cutoff setting : 0 to 30% of the maximum flow rate (Settable in increments of %) * Valid for display, analog output and pulse output. Parameter setting : Set with the key switches on the front panel of converter. Other additional functions ) Analog and pulse simulation output function (For loop check) ) Forward/backward direction measuring function Converter mounting method : Mounted onto the wall or inch pipe Enclosure : Converter / IP65 Jet-proof, Sensor / IP65 Jet-proof (guaranteed with BNC connectors coupled) Material : Sensor housing / Heat-resisting ABS Sensor mounting rail / Aluminum Converter housing / Heat-resisting ABS Painting of converter : Housing cover = Blue : Housing body = Light gray Sensor ambient temperaure : -0 to 70 C Converter ambient temperature and humidity : -0 to C, 0 to 90% RH (No dew condensation) Sensor signal cable : Standard 0 m (Up to 60 m) Table. Sensor selection table Pipe material Nominal pipe size (D) Sensor installation Sensor rail length Sensor rail fpr support Code of sensor combination Note : The UL330 flowmeter is applicable to pipes made of stainless steel or similar metals. For pipes with a schedule number of 80 or more, consult TOKYO KEISO. Note : "V" in the sensor installation column means reflex mode (V path), and "Z" means diagonal mode (Z path). Note 3 : Reinforcement rails are used for resin pipes with a nominal size of up to 40 mm. Note 4 : The V-path method may not be applicable to pipes with a nominal size of up to 400 mm depending on the specifications (material and surface of piping, or fluid condition). In this case, use the Z-path method. To avoid this, it is recommended to specify a model with two sensor rails. Note 5 : Flowmeters with a single short sensor rail may not be mounted on pipes with a nominal size of more than mm, or those which are scheduled to be replaced in the near future. In this case, specify a model with two long sensor rails. Note 6 : See the sensor combination in MODEL CODE. TOKYO KEISO CO., LTD. TG-F037-3E

75 75 75 75 75 75 UL330 ULTRASONIC FLOWMETER DIMENSIONS CONVERTER Wall mount type " pipe mount 94 -Slotted hole 9 (64) 60 40 47 UL330 STATUS 3 UL330 STATUS 3 60 40 0 MENU ENT. ZERO MEAS. BACK SET MENU ENT. ZERO MEAS. BACK SET SENSOR Reflex mode (V path) Diagonal mode (Z path) Support rail* 30/60 *Support rail is to be used for the resin pipe from to 40mm. *Refer to Table Sensor selection table. 30/60 38 38 (68) (68) 30 38 (68) 0 (68) (68) With support rail (68) Without support rail TG-F037-3E TOKYO KEISO CO., LTD. 3

FLOW RATE RANGE/SIZE Nominal diameter Possible scale range (m 3 /h) (mm) Minimum Maximum 3 40 65 80 00 0 300 3 400 0.684.67.568.556 4.9 5.857 9.948 5.00.8 36.80 57.07 8. 0.3 33..80 38.9 5.7 85. 39.7 95. 33.6 0. 709.4 6 90 708 3377 444 [Note] The above-mentioned flow rates have been calculated for the SUS Sch. 0s pipes, at the minimum range flow velocity of 0.3 m/s and maximum range flow velocity of 0 m/s. (The flow rate range may differ slightly, depending on the piping standard.) WIRING DIAGRAM CN Power supply (AC) Analog output 4 to 0mADC Totalized pulse output CN External totalization reset Status output ST com (3P) (P) (P) (P) (4P) L L FG + + + + + com + Note : ST (Status ) : Hold output ST (Status ) : Empty pipe detection ST3 (Status 3) : Forward or backward flow detection Note : The detachable connectors are used. ST ST3 MODEL CODE Sensor Sensor Model code UFS330 A Sensor combination 4 5 3 Cable length 4 5 6 Additional functions : Refer to table. Sensor selection table. (Blank) /Z Description Short sensor rail pcs, Sensor rail for support pc ( ) Long sensor rail pcs ( ) Short sensor rail pcs ( ) 0m (Standard) 0m 30m 40m m 60m NA Provided Converter Converter Model code UFC330 A A Power supply - Mounting Serial output Additional functions - (Blank) /Z to 40 V AC /60Hz Wall mount type pipe mount type Standard NA Provided Description 4 TOKYO KEISO CO., LTD. TG-F037-3E

POINTS TO BE CHECKED BEFORE USING It may be unable to make measurement when falling into the following conditions. Contact us in advance. When it cannot be judged whether it is suitable, we are prepared to make preliminary test by the actual equipment. ) Liquid The liquid containing a lot of bubbles (over % only as a guide). The liquid containing slurry and solid material (over 5wt% only as a guide). The liquid of low Reynolds number (less than Re.00 only as a guide). Liquids other than water such as lean chemical solutions, oils, waste waters and hot spring water. ) Piping The inside wall of carbon steel pipe is rusty. Adhesion and sediment are in a pipe. The outside surface of cast iron pipe is coarse. Pipe made of PVDF with thickness more than 9mm. Pipe made of PP with thickness more than 5mm. SGPW pipe [The galvanized steel pipe for water service (white gas pipe)] Lined pipe 3) Straight runs The accurate flow measurement requires straight runs both upstream and downstream of the flow sensor as shown at the next page. PRECAUTION FOR USE ) Pipe shall be always filled with fluid. ) In the case of horizontal piping, please do not mount a sensor on the upper and the lower part of piping. 3) When you wrap a sensor in an insulating material, be careful not to exceed the ambient temperature limits of a sensor. 4) In order to prevent the sensor grease from degrading when installed outside, we recommend you to mount the waterproof cover which covers a sensor assembly. TG-F037-3E TOKYO KEISO CO., LTD. 5

REQUIRED STRAIGHT RUNS D : Nominal diameter Reference : JEMIMA standard JEMIS-3 Classification Required upstream straight length Required downstream straight length 90 bend 0D L 0D L 5D Tee 0D L D L 0D 0D L 30D L 5D Expansion pipe 0.5D.5D D L 0D L 5D Reducer L 30D L 0D Valve Valve throttling at upstream pipe Valve throttling at downstream pipe Check valve Slice valve Pump L D P * Specification is subject to change without notice. Head Office : Shiba Toho Building, 7 4 Shibakoen, Minato-ku, Tokyo 05 8558 Tel : +8-3 343 6 (KEY) ; Fax : +8-3 3433 49 e-mail : overseas.sales@tokyokeiso.co.jp ; URL : http://www.tokyokeiso.co.jp 6 TG-F037-3E