Computer-simulation study on fire behaviour in the ventilated cavity of ventilated façade systems



Similar documents
Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Introduction. Facade Fire Test on PUR External Thermal Insulation Composite System (ETICS)

Fire-Rated Glass and Glazing START

FIRE LOSS STATISTICAL CONSIDERATIONS IN RELATING FAILURE AND BUILDING DAMAGE TO THE BUILDING CODE OBJECTIVES

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

Loss Prevention Standard

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

Fire Performance Standard

EVALUATION OF PHOENICS CFD FIRE MODEL AGAINST ROOM CORNER FIRE EXPERIMENTS

Evaluating the Field Performance of Windows and Curtain Walls of Large Buildings

Excerpts from the Canadian National Building Code (NBC)

Available online at ScienceDirect. Procedia Engineering 62 (2013 ) Lei Peng*, Zhaopeng Ni, Xin Huang

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Influence of fire source locations on the actuation of wet-type sprinklers in an office fire

Composite Panel Firewall Systems

Fire safety in timber buildings

Tremco Fire Protection Systems Group Technical Bulletin

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Module 3.7. Thermal bridging

A new approach to the Danish guidelines for fire protection of combustible insulation

Condensing Boiler Efficiency

Decree of the Ministry of the Environment on fire safety of ventilation systems

RESSÒ: energy efficiency urban rehabilitation

Validation of Modeling Tools for Detection Design in High Airflow Environments

Piotr Tofiło a,*, Marek Konecki b, Jerzy Gałaj c, Waldemar Jaskółowski d, Norbert Tuśnio e, Marcin Cisek f

Building Code Clarifications - 7. Fire Resistance

research highlight Highly Energy Efficient Building Envelope Retrofits for Houses

Hoesch Matrix System individuell. ThyssenKrupp Steel Europe Thinking the future of steel

Reducing Injury and Damage Related to Electric Dryer Fires. Fire Containment Tests for the Second Edition of UL 2158

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

WHITE PAPER Fire & safety performance standards

Dubai Municipality Standard DMS 1: Part 5: 2004

Molds and mildew are fungi that grow

Adaptive strategies for office spaces in the UK climate

1..GENERAL DATA 2. CLIMATIC DATA. Location

Development of Seismic-induced Fire Risk Assessment Method for a Building

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

FIRE-RESISTANCE-RATED CONSTRUCTION

GENERAL FIRE SAFETY TERMS & DEFINITIONS

LPCB Red Book Listed Products and Passive Fire Protection Installer Schemes Answering the needs of the market

Improving fire safety through engineering (rational designs)

Appraisal of Passive and Active Fire Protection Systems in Student s Accommodation

FIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS

Integrated Solar Radiant Systems

Post-insulation of cellar ceiling and cellar walls

FIRE-RESISTANCE-RATED CONSTRUCTION

NEW SCIENCE FIRE SAFETY ARTICLE INNOVATING FIRE ATTACK TACTICS SUMMER 2013 UL.COM/NEWSCIENCE

eading Performance Solutions

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

- 5 - Table1. Maximum Compartment Volumes

Prefabricated building PVC vertical sliding window

Annex of the certificate (Page 1/6) Accreditation Scope

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

ON MOST schemes, the architectural design of. Flexible strategy. Case study. The Forum

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Fire Development and Fire Behavior Indicators

FIRE AND SMOKE PROTECTION FEATURES

Fire Safety Requirements for Child Care Centre

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

Pearl River Tower, Guangzhou: Fire Protection Strategies for an Energy Efficient High-Rise Building

IFE Level 4 Certificate in Fire Science and Fire Safety (HL)

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

Loss Prevention Standard

Passive house rehabilitation of post war residential building in Zug, Switzerland

Approval Standard for Plastic Suspended Ceiling Panels

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

HEALTHY LIVING WITH WOOD FIBRE INSULATING MATERIALS

Analysis II Façade Redesign: Architectural Precast Panels

ROOFS, SNOW AND ICE DAMS

Insulating Basements: Part 3 Basement Wall Systems

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

CONDENSATION IN REFRIDGERATED BUILDINGS

Decree of the Ministry of the Environment. on fire safety of garages

Preventing Ice Dams on Roofs

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Fiberglas, Exterior Wall Thermal Insulation

Improving thermal insulation of concrete sandwich panel buildings

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

Water Vapor Permeance of Wood Structural Panels and Wood Wall Construction

FIRE RATED WIRING. What the FT4! Paul Latreille, C.E.T. Ottawa Branch Manager

Fire Testing of Recycled Materials for Building Applications

Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces

Windows are one of the most important components of a

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Safety Storage Cabinets

A study of the nature of fire risks in tall buildings

GYPSUM AREA SEPARATION FIREWALLS GA

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

Flow in data racks. 1 Aim/Motivation. 3 Data rack modification. 2 Current state. EPJ Web of Conferences 67, (2014)

Rockwool Flexi Insulation Application Guide

Watermist fire suppression systems for commercial low hazard occupancies

Approval Standard for Fume Exhaust Ducts or Fume and Smoke Exhaust Ducts

Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports.

Fire Resistance of Brick Masonry

The Case for Cross Laminated Timber: Part 2

Transcription:

MATEC Web of Conferences 9, 03002 (2013) DOI: 10.1051ßmatecconfß20130903002 C Owned by the authors, published by EDP Sciences, 2013 Computer-simulation study on fire behaviour in the ventilated cavity of ventilated façade systems María P. Giraldo 1, Ana Lacasta 2, Jaume Avellaneda 3 and Camila Burgos 1 1 INCAFUST Catalan Institute of Wood, Barcelona, Spain 2 Architectural Buildings Department, Technical University of Catalonia (UPC), Barcelona, Spain 2 Applied Physics Department (EPSEB), Technical University of Catalonia (UPC), Barcelona, Spain Abstract. Fire spread through the façades is widely recognized as one of the fastest pathways of fire spreading in the buildings. Fire may spread through the façade in different ways depending on the type of façade system and on the elements and materials from which it is constructed. Ventilated façades are multilayer systems whose main feature is the creation of an air chamber of circulating air between the original building wall and the external cladding. The chimney effect in the air cavity is a mechanism that improves the façade s thermal behaviour and avoids the appearance of moisture from rain or condensation. However, in a event of fire, it may contribute to the quickest spreading of fire, representing a significant risk to the upper floors of a building. This study deals with some aspects of fire propagation through the ventilated cavity in ventilated façade systems. Also we review the provisions stipulated by the Spanish building code (Código Técnico de la Edificación, CTE) [1] to avoid fire spread outside the building. The results highlight the importance of the use of proper fire barriers to ensure the compartmentalization of the ventilated cavity, as well as the use of non-combustible thermal insulation materials, among others. In addition, based on the results, it might be considered that the measures stipulated by the CTE are insufficient to limit the risks associated with this kind of façades systems. The study has been performed using field models of computational fluid-dynamics. In particular, the Fire Dynamics Simulator (FDS) software has been used to numerically solve the mathematical integration models. BACKGROUND The ventilated façade system belongs to a group called cladding systems and is an updated version of that known as cavity wall. This method of construction was introduced in the Northwest of Europe during the 19th century and gained widespread use from 1920. Both systems base their performance on the air chamber of the cavity, and while the cavity wall system has been used only in brick walls, the ventilated façade has a vast variety of finishes. Nowadays the trend in architecture is towards a growing usage of lightweight construction systems that are quick to install (drywall construction), versatile and have a high technical and aesthetic value. The ventilated façade has all these characteristics as well as providing a good performance from an acoustic and hygrothermal point of view. In Spain and other Mediterranean countries, the use of ventilated façades over the last ten years has significantly increased as a result of the good performance of this kind of façade system. They are used in new buildings as well as in the refurbishment of façades. This is an Open Access article distributed under the terms of the Creative Commons Attribution License 2.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Article available at http://www.matec-conferences.org or http://dx.doi.org/10.1051/matecconf/20130903002

MATEC Web of Conferences 5 2 3 1 4 (A) (B) (C) Figure 1. Façade cavity systems (A) Cavity wall (B) ventilated façade (C) elements of ventilated façade. The use of ventilated façades offers advantages such as: Contributes to thermal comfort and energy saving: the fitting of insulation on the outside of walls and slabs eliminates thermal bridges in any part of the façade, thereby preventing the loss of heat to the exterior in winter and absorbing heat in summer. Elimination of condensation on the inside of the façade wall: the pressure difference between the air in the cavity and outside leads to the creation of an airflow known as the chimney effect, which eliminates humidity in wet conditions and prevents condensation. However, in terms of fire safety, the chimney effect poses a risk, because the ventilated cavity may provide a pathway for the fire to spread quickly. In general, the provisions of the Spanish building code (CTE) on external fire spread are perceived as insufficient to address risks associated to the fire spreading through the façades, taking into account the different types and design of the façade. This study focuses on the CTE provisions regarding ventilated façades with the purpose of analyzing the risks which are not sufficiently covered. Fire spread through the ventilated cavity When there is a fire in a building, the façade may be one of the quickest spreading pathways. Some types of façades, as in the case of ventilated façade systems, pose a greater risk because of the characteristics of the elements that comprise them. The ventilated façade is a multilayer system consisting of the following elements (Fig. 1C): 1. Support: (wall, column, slab, etc) a resistant structural element which is part of the building and is responsible for transmitting forces to the structure of the building. 2. Substructure/ fixing system: a set of resistant elements responsible for transmitting forces received by the cladding to the support. Metal railing systems, usually aluminium uprights and cross members. 3. Insulation: Located on the exterior side of the supporting wall. 4. Air chamber: The cavity formed by the separation between the cladding and insulation (fixed to the building wall). 5. Cladding: The outer face of the façade, which be composed of different materials. Several authors have highlighted the influence of the geometric factor of the façade in the development of a fire and its spread through the façade surface [2, 3]. In particular, it has an impact on the speed of propagation of fire, and the shape and trajectory of the fire plume. 03002-p.2

1 st International Seminar for Fire Safety of Facades, Paris (France), 2013 The arrangement of the components of a multilayer façade, such as the ventilated façade, may be understood as part of its geometric development. Therefore, the ventilated cavity is an element that significantly influences the behaviour of fire. In a ventilated façade, fire may spread along the following routes: 1. Through the window openings by the so-called leap frog" effect. 2. Through the surface of the cladding, when the reaction of the material to fire contributes to the rate of fire spread, and 3. through the ventilated cavity, if adequate fire barriers are not employed; due to the chimney effect, this latter factor is considered the fastest propagation pathway [4]. In this study we focus only on this last case. Once the fire is within the ventilated cavity, the hazards associated with the fire spreading through the cavity are as follows: Thermal properties of insulation. If a combustible material is used (which is often the case), fire intensity increases. The substructure of the façade. In this type of fire incident, the temperature within the fire envelope may achieve a local temperature in excess of 600 C. Regardless of the external panel construction, if fire enters the cavity and comes into contact with the aluminium substructure, it may begin to lose its local strength and integrity as it is heated. Under prolonged fire exposure conditions, the railing system could melt, which may lead to localised system collapse. Cavity shape and chimney effect. As mentioned above, fire spread in ventilated façades occurs through the windows and the ventilated cavity. This may occur simultaneously. When flames are confined by the cavity, they will become elongated as they seek oxygen and fuel to support the combustion process. This process, together with the chimney effect, may lead to a flame extension five to ten times greater than of the fire plume spreading through the windows [4], regardless of the materials used as insulation. This may enable fire to spread quickly and unseen through the external cladding system, if appropriate fire barriers have not been provided. Vulnerable areas. Window and door frames may provide a direct entry route to the cavity. These are usually made of aluminium or PVC and lack fire barriers or seals. Provisions of the CTE on ventilated façades The Spanish building code CTE (DB SI) Fire Safety (Sects. 1 and 2) addresses the spread of fire in a very general way. It makes only a succinct reference to façade ventilated systems. In particular, it relates to two aspects: Fire barriers, under the following conditions: Barriers in cavities are required every 3 storeys or 10 m, in buildings higher than 18 m. Barriers in cavities are required every 3 storeys or 10 m, in buildings less than 18 m, except in cases in which insulation materials meet the classification of fire reaction B-s3,d2, i.e. it has a low level of combustibility. Otherwise, no fire barrier is required. Combustibility of thermal insulation material, under the following conditions: The insulation should meet the classification of fire reaction B-s3,d2 throughout the height of the entire building, in buildings higher than 18 m. The insulation should meet the classification of fire reaction B-s3,d2 until 3.50 m in public access areas. The rest of building does not have this requirement. The regulation does not provide details about these requirements. 03002-p.3

MATEC Web of Conferences Table 1. Computational domain. Scenarios Mesh size (m) Number of cells Cell size Basic scenario 4.90 6.50 8.25 241,920 10 10 1 Double size scenario 4.90 6.70 18 599,760 10 10 10 OBJECTIVES This study aims to assess fire behaviour and its propagation through the cavities of ventilated façades systems. In particular, we seek to assess the level of protection provided by the measures stipulated by the CTE. We focus our study on the following aspects: A. Fire barriers in the ventilated cavity. Two different methods for partitioning the cavity are considered. B. The influence of the use of combustible and non-combustible thermal insulation. C. The influence of the size of the cavity and level of ventilation. Three variables are considered: low, medium and high ventilation. METHODOLOGY This research is conducted using field models of computational fluid-dynamics to evaluate some aspects of fire dynamics in the different cases studied, the conditions of which are explained below. In particular, the following software is used: The Fire Dynamics Simulator (FDS) to solve the models PyroSim for the graphical interface, and Smokeview to visualize the results. Computer-simulation is a useful tool that provides an approach to the problem of fires, taking into account different variables and scenarios. One of the great advantages of simulation is the possibility to study some aspects of the phenomenon of fire without incurring the high costs of laboratory tests. This does not mean that computer-simulation can replace the laboratory tests; however, it is a powerful tool for carrying out complementary studies, mainly as regards the physical behaviour of fire. In this research a scenario representing a fire in a living room is considered. The fire starts on a couch in the ground floor of the scenario. To achieve this, an ignition source of 400 cm 2 is placed on the surface of the couch. This source is characterized by a burner with a heat release rate of 1000 kwßm 2. Once the fire reaches the stage of flashover, it spreads to the outside through the windows. The windows are disabled when a device (heat detector) reaches 300 C. Moreover, the window frames are disabled when a device (heat detector) reaches 500 C (Considering a failure in the aluminium window frames due to fire exposure) as a result fire enters to the cavity. Fire growth occurs according to the calculation performed by the software. The FDS solves the equations governing the simulated system and provides graphical and numerical data for each scenario. The models show a simplified representation of the analyzed cases. Eight cases are evaluated based on a common computational domain and a fire scenario. Table 2 describes the variables considered in each case under study. The characteristics of the computational domain and the scenarios are described below. Computational domain Two computational domains are performed; one is the basic scenario and the other is double the size scenario. The basic scenario size is 6.50 m 4.90 m 8.25 m. Each cell has a uniform size (0.10 m 0.10 m 0.10 m). Table 1 shows the information about the two domains. Previously, two different computational domains are also performed for the same scenario to compare the evolution of fire: with cell size (0.20 m 0.20 m 0.20 m) and (0.10 m 0.10 m 0.10 m). The results were similar for both domains. The smaller mesh was chosen to all simulations. 03002-p.4

1 st International Seminar for Fire Safety of Facades, Paris (France), 2013 B A Open door Figure 2. Computational domain three-storey scenario. Figure 3. Geometric description of the scenarios and location of the thermocouples. Table 2. Case studies. (C) Cavity size and ventilation level (A) Fire barriers (B) Thermal insulation FB WB CI NCI Floor Window Combustible Non combustible barriers barriers insulation insulation LV o o o o Low ventilation MV o o Medium ventilation HV o High ventilation Double size o scenario The simulations parameters are follows: Temperature: 10 C, Moisture: 60%, ventilation conditions 1.0 m/s (3.6 km/h), Simulation time: 900 seconds. There are two different areas to be considered in the domain (Fig. 2): (A) Enclosure (Living room) and (B) Open (external conditions). 03002-p.5

MATEC Web of Conferences (A) Fire barriers (FB) Floor barriers (WB) Window barriers (B) Thermal insulation (CI) Combustible Insulation similar in type to polyurethane foam (NCI) Non combustible insulation similar in type to rock wool (C) Cavity size and ventilation level 1.0 m/s 2.5 m/s (LV) Low ventilation 7 cm cavity width (MV) Medium ventilation 17 cm cavity width (HV) High ventilation 7 cm cavity + forced air flow Figure 4. Details of the ventilated cavity elements. Geometric configuration and contents of the scenarios The fire scenario consists of a three-storey living space of 4.00 m 4.90 m. Each floor is 2.50 m high and is separated by concrete floors (non-combustible material). The façade cladding material is non-combustible. The scenario is representative of a typical living space with a fire load density 03002-p.6

1 st International Seminar for Fire Safety of Facades, Paris (France), 2013 1000 1000 Temperature ( C) 800 600 400 200 Temperature ( C) 800 600 400 200 0 0 200 400 600 800 Time (s) 0 0 200 400 600 800 Time (s) Without barrier (FB) (WB) Without barrier (FB) (WB) (A) (B) Figure 5. (Top) comparative of temperatures between a scenario without barrier and the two types of barriers studied, for thermocouples 1 (left) and 2 (right). (Bottom) graphics of fire spreading through the façade. (A) With barriers, at time of 300 s. (B) Without barriers, at 250 s and 300 s. approximately of 600 MJßm 2. The characterization of the materials that constitute the furniture is based on some parameters extracted from the database of Ref. [6]. Measurements devices Data on the evolution of the temperatures are recorded through thermocouples located at the height of the parapet of the first floor, both inside and outside. Furthermore, thermocouples are placed inside the chamber to check the temperatures reached (Fig. 3). In order to observe the distribution of temperatures in certain areas of the scenario, chromatic planes of two dimensions are used, as seen in Figures 6 and 7. Ventilated cavity details As indicated in the research objectives, in this study three aspects related to the ventilated cavity are explored. Table 2 and Figure 4 shows the information on each of them. Two sizes of ventilated cavity are studied LV and MV (low and medium ventilation) according to the provisions of CTE DB HE Energy Savings (Appendix E). The third type of ventilation HV (high ventilation) incorporates a forced air flow. 03002-p.7

MATEC Web of Conferences 800 Temperature (ºC) 600 400 200 0 0 200 400 600 800 Time (s) T1 (10 m) T2 (16.50) T3 (16.50) ºC (A) (B) Figure 6. (Top) temperatures recorded by thermocouples located inside the cavity. (Bottom) (A) graphics of flames and smoke through the façade without fire barriers, at 450 s. (B) Temperature distribution for the same situation. RESULTS The results show the great influence of the ventilated cavity in fire spread through the façade, should adequate fire barriers not be employed. Fire barriers In all the cases studied, we observe that is very important to consider the use of fire barriers to prevent the entry and spread of flames into the cavity. It is also observed that fire spread through the cavity is much faster than through the windows. In addition, the probability of fire spread to the upper floors is greater. The comparative of temperature evolution (Fig. 5 top) show peaks at slightly lower temperature on the surface of the façade when using barriers; indicating that the fire plume projected on the façade has a similar behavior in both cases. However, temperatures inside the enclosure are significantly lower when 03002-p.8

1 st International Seminar for Fire Safety of Facades, Paris (France), 2013 HRR (KW) 30000 25000 20000 15000 10000 5000 0 0 200 400 600 800 Time (s) CI NCI Temperature (ºC) 1000 800 600 400 200 0 0 200 400 600 800 Time (s) CI NCI (A) (B) Figure 7. (Top) comparative of HRR and temperatures (thermocouples 4) between scenarios with combustible and non-combustible insulation. (Bottom) graphics of flame spread and temperature distribution, at 350 s. (A) Combustible insulation CI. (B) Non-combustible insulation NCI. using barriers (FB) (WB). This shows that, preventing the passage of fire through the ventilated cavity decreases significantly the possibility of fire spreading to upper floors. In general, it is observed that both partitioning methods are effective in preventing the passage of fire to the ventilated cavity. However, it should be considered that the barriers FB have the additional ability to limit the passage of flame through the camera, while the barriers WB only limit the input or output of fire through the window frames (or doors). This is an important aspect because the interior of the cavity may reach high temperatures. In the non-combustible insulation scenarios, temperature peaks near 800 C were recorded, being of about 1000 C in the scenarios with combustible insulation. The double size scenario (18 meters) (height reference used by the CTE) which are performed without barriers, shows the ability that may have the fire and smoke to spread through the cavity, even if the insulation is non-combustible, as seen in Figure 6. This result highlights the importance of compartmentalize the ventilated cavity to prevent this type of spread. Because the study is conducted using computational techniques, it is not possible to obtain data on the fire resistance of the elements or on the degradation of materials exposed to flames, but rather their influence on fire dynamics. The potential effectiveness of a fire barrier design can only be fully assessed as a part of a series of large-scale tests. Thermal insulation It is observed that the combustibility characteristics of the thermal insulation material has a significant influence on the intensity and velocity of fire propagation through the cavity as seen in the comparative of HRR and temperatures in the curves of Figure 7 (top). 03002-p.9

MATEC Web of Conferences Table 3. Summary of temperature peaks. LV MV HV CI NCI CI NCI NCI 3 4 3 4 3 4 3 4 3 4 900 C 600 C 550 C 250 C 700 C 750 C 450 C 500 C 900 C 400 C 1 2 1 2 1 2 1 2 1 2 750 C 600 C 750 C 400 C 830 C 570 C 550 C 500 C 950 C 500 C Once the fire is within the cavity the propagation through the ventilated cavity occurs quickly, regardless of used insulation material. However when this is a combustible material the spread of fire is much more intense and the probability of fire spread to the upper floors is increased (Fig. 7 thermocouple 4). Cavity Fire is a phenomenon sensitive to external factors. Ventilation is one of the factors that more affect fire behavior. The results obtained from the different temperature curves shown that the size of the cavity and the flow of ventilation affect the spread of fire through the ventilated cavity. It is observed that the larger the camera is, the higher possibility of the fire spreading to the upper floors. According to the results on the scenario HV it may be considered that the ventilation contributes to the spread of fire through the cavity. The impact of ventilation may be more decisive than the size of the camera. Table 3 shows a summary of the temperature peaks reached in each case. CONCLUSIONS The ventilated cavity is a potential pathway for fire spreading in fire situations. For this reason the compartmentalization of the cavity on each floor of the building, by using appropriate barriers, is considered essential in order to prevent this type of propagation. The establishment of barriers every 3 floors or 10 meters, as is required by the Spanish building code (DB-SI Sect. 1.3), is not sufficient: it would be equivalent to protect a part of the building while the other part remains without protection. The spread of fire through the ventilated cavity is due to the system configuration and the façade chimney effect that occurs within the cavity, regardless of the used thermal insulation material (whenever non-combustible). The provision of CTE (DB SI Sect. 2.4), in the sense that partitioning barriers are not required in buildings lower than 18 meters (in the conditions already explained), leaves a significant risk without covering. Therefore it deserves to be revised by legislation. It s worth to mention that a high percentage of residential buildings in Spain are lower than 18 meters. It is important to use appropriate fire barriers which, at same time, allow the ventilated cavity to properly work in normal circumstances, without affecting the hygrothermal performance of the façade. The products market has evolved a lot in this area and offers interesting options based on intumescent materials. Fire barriers arranged on the window frames are considered appropriate to prevent the passage of fire from one fire compartment to the ventilated cavity and vice versa. However, as they do not contain the passage of fire through the cavity, they are not effective in preventing the damage of the ventilated cavity substructure by the fire. Barriers crossing the entire façade are more effective for this purpose. The use of combustible insulation materials significantly increases the spreading and the fire intensity and raises, therefore, the level of risk. We recommend the use of non-combustible insulation materials (reaction class A or B) along the whole façade. 03002-p.10

1 st International Seminar for Fire Safety of Facades, Paris (France), 2013 It is important, in our opinion, to inform the professionals involved in building about the risks that remain unfilled by the regulations. The appropriate protective measures should be incorporated even if they are not required by the current regulations, because its fulfillment does not guarantee, in all the cases, an acceptable safety level. References [1] Spanish Building Code CTE (Código Técnico de la Edificación) DB SI, Section 1 concealed spaces and Section 2 external propagation of fire, 2006. [2] S. Yokoi, Study on the Prevention of fire spread caused by hot upward current, Building Research Institute, Report N 34, Tokyo, Japan, 1960. [3] Oleszkiewicz, Vertical separation of windows using spandrel walls and horizontal projections, Fire Technology, 27, pp.334 340, 1991. [4] S. Collwell, B. Martin, Fire performance of external thermal insulation for walls of multi-storey buildings, Building Research Establishment BRE, London, 2003. [5] Avellaneda, Jaume, Façanes lleugeres ventilades: Criteris per al disseny constructiu, Departament de Construccions Arquitectòniques I. Papers de Construcció, Barcelona, 1997. [6] Giraldo, M., Evaluación del comportamiento del fuego y protección contra incendios en diversas tipologías de fachadas, doctoral thesis, Technical University of Catalonia UPC, Architectural Buildings Department, 2012. [7] Fire Dynamics Simulator (version 5), NIST. http://www.nist.gov. 03002-p.11