F61 Series Standard Flow Switches

Similar documents
T25 Two-Stage Room Thermostat

OLS-2100 Occupancy Light Switch

! WARNING. Before using product, read and understand instructions.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

P70, P72, and P170 Series Controls for Dual Pressure Applications

TE-6300P Series Temperature Sensors

VG2000 Series Cast Iron Flanged Globe Valves

A99B Series Temperature Sensors

CST29A Adapter Block for Carlyle Compressors

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

System 350 A350A/B Electronic Temperature Control

Part I - Installation

V46 Pressure-Actuated Water-Regulating Valve

VG7000 Series Bronze Control Valves

P66 Series Electronic Fan Speed Controls

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

Dual Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

V47 Series Temperature Actuated Modulating Water Valves

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Toroidal Conductivity Sensor

Your safety and the safety of others are very important.

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Series 510 Submersible Level Transmitters

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Digital inductive conductivity transmitter

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Cooktop Low-Profile Ventilation Hoods

OPL BASIC. Dosing System for Professional Laundry machines. Contents

MP8000 Series Pneumatic Valve Actuators

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Submersion/Insertion Toroidal Sensor

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

INSTALLATION GUIDE AND OWNER S MANUAL

G670 Intermittent Pilot Ignition Controls

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

Series Hose Reels

Leak Detection System

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Technical Instructions Document No P25 ET September 28, ET 141 High Limit Control Thermostat. Description.

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

4077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE FAX

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

758 Heavy-duty Ratchet Guy Wire Cutter

DC400 Dispensing Cutoff System

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Warrick Series DMS-470/570 Montoring Panels Installation and Operation Bulletin

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

SENSOR FAUCETS. OPTIMA ETF-80 Faucet. P a r t s G u i d e 24 VAC HARDWIRE FAUCETS SLOAN VALVE COMPANY SEYMOUR AVENUE FRANKLIN PARK, IL 60131

Water Leak Detection System

Installation Manual DIAPHRAGM WELL TANK

08.08 Vic-Check Valves

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

Instructions For SF 6 Refill Kit

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Flat Bottom Long Ram Hydraulic Jack

Allen-Bradley HP AC Line Filter Kit

P499 Series Electronic Pressure Transducers

USER MANUAL. 10 GPM Small Single Line Cryogenic Coupling

PBX Series Quick Fit Connector Bimetallic Steam Traps

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

Operator: Save these instructions for future use!

INSTRUCTION MANUAL A REVISION A. Series E1 and E3 Instant Hot Water Recirculating Systems

Read this document before using this product.

Technical Data. Installation

A-4000 Oil Indicator

Cable Plug acc. to DIN EN , Form A

1805 Series Relief Valves

Wafer Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Power Cube Open Source Ecology Page 1. Power Cube. Version 4

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

INSTANT HOT WATER RECIRCULATING SYSTEM

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

System 350 A350E Electronic Cooling Control

Float and Thermostatic Traps Series H, C and X

Powers Controls TH 192 S Single Temperature Room Thermostat

T7079A,B Solid State Remote Temperature Controllers

Manual motor starter MS116

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

AMERBRITE UNDERWATER WHITE LED POOL LAMP

Explosion proof enclosures

Installation Instructions DTS-HAZ DTS-HAZ-DC. for Use with Self-Regulating & Constant Wattage Heating Cables

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Submersion/Insertion Toroidal Sensor

Transcription:

Installation Instructions F61 Issue Date May 30, 2014 F61 Series Standard Switches Installation IMPORTNT: Use this F61 Series Standard Switch only to control equipment under normal operating conditions. Where failure or malfunction of the flow switch could lead to personal injury or property damage to the controlled equipment or other property, additional precautions must be designed into the control system. Incorporate and maintain other devices, such as supervisory or alarm systems or safety or limit controls, intended to warn of or protect against failure or malfunction of the flow switch. IMPORTNT: Utiliser ce F61 Series Standard Switch uniquement pour commander des équipements dans des conditions normales de fonctionnement. Lorsqu'une défaillance ou un dysfonctionnement du flow switch risque de provoquer des blessures ou d'endommager l'équipement contrôlé ou un autre équipement, la conception du système de contrôle doit intégrer des dispositifs de protection supplémentaires. Veiller dans ce cas à intégrer de façon permanente d'autres dispositifs, tels que des systèmes de supervision ou d'alarme, ou des dispositifs de sécurité ou de limitation, ayant une fonction d'avertissement ou de protection en cas de défaillance ou de dysfonctionnement du flow switch. Some models of the F61 Series Standard Switches require installation or adjustment of paddles prior to mounting. See Installing the Paddles. Parts Included Standard models of the F61 flow switch include an installed three-piece flow paddle. Some models also include a large flow paddle for large pipe sizes. Table 1: Replacement Parts Kit Number Description KIT21-600 Stainless Steel Three-piece Paddle (3 in., 2 in., and 1 in. Segments) KIT21-601 Stainless Steel 6 in. Paddle PLT52-600R Stainless Steel Three-piece Paddle (3 in., 2 in., and 1 in. Segments) and 6 in. Paddle CVR62-600R Replacement Cover ssembly for LB, MB, MD, and MG types Installing the Paddles IMPORTNT: To allow the switch to detect changes in the fluid flow, the flow paddle must not touch the pipe or any restrictions in the pipe. djust flow paddles to the size of the pipe used. If needed, trim the large flow paddle at the arc corresponding to pipe size (see Figure 1 and Figure 2) and install. Paddle Trim flow paddles to fit pipe diameter or remove flow paddles that are too large to fit pipe diameter. Figure 1: Installing the Paddles 2014 Johnson Controls, Inc. 1 Part No. 24-8407-4, Rev. D www.johnsoncontrols.com

1-1/2 in. 1 in. 2 in. 2-1/2 in. 3 in. 4 in. 5 in. Original Length 6 in. Dimensions Figure 2: Trimming Diagram for Large Paddle 4 (102) 2 (51) 7/8 (22) 1-1/16 (27) Diameter Hole for 1/2 in. Trade Size Conduit Diameter Knockout Ring for 3/4 in. Trade Size Conduit 1-3/8 (35) 2-3/4 (71) 2-11/16 (68) 1-3/4 (44) Dimension by Liquid Line Size 1 (25) 1-7/16 (37) B 1 (25) Use these wrench flats to tighten the flow switch at installation. Paddle 1-1/4 (33) 1 in. 11-1/2 NPT 4-3/4 (121) B Grounding Hole 2 (51) 3 (76) 4 (101) 5 (152) 2-1/2 (64) 3-1/2 (89) 6-5/8 (168) 6-5/8 (168) Figure 3: NEM 1 Enclosure (F61KB Types) Dimensions, in. (mm) 2 F61 Series Standard Switches Installation Instructions

Use these wrench flats to tighten the flow switch at installation. Paddle 3-11/16 (94) 1-13/16 (47) 1-1/4 (33) 1 in. 11-1/2 NPT On MB and MG Types 1/2-14 NPSM Thread 5/8 (15) On LB Types 2-7/8 (73) 1-9/16 (40) 4-3/4 (121) 1-1/16 (27) B 1-3/8 (35) 2-3/4 (71) Dimension by Liquid Line Size 1 (25) 2 (51) 3 (76) 4 (101) 5 (152) 1-7/16 (37) 2-1/2 (64) 3-1/2 (89) 6-5/8 (168) 6-5/8 (168) B 1 (25) Figure 4: NEM 3 or NEM 3R Enclosure (F61LB, F61MB, F61MG Types) Dimensions, in. (mm) used, install a face or hex bushing in the top opening to reduce it to 1 in. Mounting IMPORTNT: To avoid damaging the switch, do not tighten the switch to the tee by grasping the switch enclosure. Use only the wrench flats provided. Mount the F61 Series Switch, using the following guidelines: Install the switch so that the cover and interior are accessible. Mount the switch so that the flow of fluid is in the direction of the arrow on the switch casing. Use a pipe union on each side of the flow switch to allow easy removal or replacement. Mount the switch so that the pipe does not extend too far into the flow switch casing. Use pipe thread sealer on male threads only. Do not remove the cover gasket or the wire grommet from the conduit opening. For 1 in. pipe installation, mount the F61 flow switch in a standard 1 in. x 1 in. x 1 in. tee. For larger sizes of pipe, use a reducing tee to keep the flow switch close to the pipe and provide adequate paddle length in the flow stream. Mount the flow switch so the terminals or wire leads are easily accessible for wiring. the flow switch in position so the flat of the paddle is at a right angle to the flow. The arrow on the side of the case must point in the direction of the flow. Location Considerations Mount the F61 flow switch in a horizontal pipeline or a vertical pipeline with upward fluid flow. Do not use in a vertical pipeline with downward flow. When mounted in a vertical pipe with upward flow, the switch trips at a slightly higher flow than shown in Table 3 through Table 6, due to the effect of gravity on the switch mechanism. Mount the F61 flow switch in a section of pipe where there is a straight run of at least five pipe diameters on each side of the flow switch from the nearest elbow, valve, or other pipe restriction. See Figure 5. Example: Use a 2 in. x 2 in. x 1 in. tee for a 2 in. pipe. If a standard 2 in. x 2 in. x 2 in. tee is F61 Series Standard Switches Installation Instructions 3

Tee or Welded Half-coupling IMPORTNT: To prevent moisture from entering and condensate from forming inside the NEM 3R enclosure, do not remove the cover gasket or the wire grommet from the conduit opening. Dimension must be at least five pipe diameters from the nearest elbow, valve, or other pipe restriction. Figure 5: Required Piping Distance Do not subject the flow switches to water hammer. Use a suitable water hammer arrester if a fast-closing valve is located downstream of the flow switch. See Figure 6. IMPORTNT: Install all wiring in accordance with the National Electrical Code and local regulations. Make all wiring connections using copper conductors only. Do not exceed the control s electrical rating. The F61KB and F61LB models have three color-coded terminals. Red is common. See Table 2 and Figure 1 for switch action. The F61MB and F61MG models have four color-coded wire leads. Red is common, green is ground. See Table 2. Switch Water Hammer rrester Valve Table 2: Switch ction ction Switch Closure Red to Yellow Red to Blue Figure 6: Water Hammer rrester Location Schematic in bove Setpoint in bove Setpoint Wiring Red! WRNING: Risk of Electric Shock. Disconnect the power supply before making electrical connections. Contact with components carrying hazardous voltage can cause electric shock and may result in severe personal injury or death. VERTISSEMENT: Risque de décharge électrique. Débrancher l'alimentation avant de réaliser tout branchement électrique. Tout contact avec des composants conducteurs de tensions dangereuses risque d'entraîner une décharge électrique et de provoquer des blessures graves, voire mortelles. IMPORTNT: Using terminal screws other than those provided will void the warranty and may damage the switch. Use only the terminal screws furnished. Yellow Blue Figure 7: Switch ction Setup and djustments! WRNING: Risk of Electric Shock. Disconnect the power supply before making electrical connections. Contact with components carrying hazardous voltage can cause electric shock and may result in severe personal injury or death. VERTISSEMENT: Risque de décharge électrique. Débrancher l'alimentation avant de réaliser tout branchement électrique. Tout contact avec des composants conducteurs de tensions dangereuses risque d'entraîner une décharge électrique et de provoquer des blessures graves, voire mortelles. 4 F61 Series Standard Switches Installation Instructions

IMPORTNT: The switch is factory set at approximately the minimum flow rate (see Table 3 through Table 6). Do not set lower than the factory setting because that may result in the switch failing to return to a no flow position. djusting IMPORTNT: Sealed settings (screws marked with black paint) are not intended to be changed. djustment attempts may damage the control or cause loss of calibration, voiding the warranty. To adjust the setting of the flow switch: 1. Disconnect power supply before making electrical connections. 2. Remove the F61 flow switch cover. 3. Turn the adjusting screw clockwise to raise the flow rate. Turn the adjusting screw counterclockwise to lower the flow rate. See Figure 8. 4. Replace the cover after completing adjustments. Tighten the cover screws to 12 in lbs of torque. Note: Do not lower the flow rate unless it has been raised from the factory setting. Lower Rates Less liquid flow required to switch from R-Y to R-B. Higher Rates More liquid flow required to switch Red from R-Y to R-B. Yellow Blue Figure 9: Minimum djustment Main Lever djusting Figure 8: Rate djustment To verify that the flow rate is set above the factory minimum (see Figure 9): 1. Depress the main lever numerous times. If the lever fails to click upon return at any time, the flow rate is set below the factory-set minimum. 2. Raise the flow rate to approximately the factory minimum by turning the adjusting screw clockwise until the lever clicks upon return every time. F61 Series Standard Switches Installation Instructions 5

Typical Rates for Standard F61 Switches Table 3: F61KB, F61LB, and F61MB Models, 1-3 in. Paddles GPM (m 3 /hr) Required to ctuate Switch Pipe Size (in.) 1 1-1/4 1 1-1/2 1 2 2-1/2 2 3 4 3 5 3 6 3 8 3 Minimum djustment Maximum djustment (R to Y (R to B (R to Y (R to B 4.20 (0.95) 2.50 (0.57) 8.80 (2.0) 8.50 (1.93) 5.80 (1.32) 3.70 (0.84) 13.3 (3.02) 12.5 (2.84) 1. Values for 2 in. paddle trimmed to fit pipe. 2. Values for 3 in. paddle trimmed to fit pipe. 7.50 (1.70) 5.00 (1.14) 19.2 (4.36) 18.0 (4.09) 13.7 (3.11) 9.50 (2.16) 29.0 (6.59) 27.0 (6.13) 18.0 (4.09) 12.5 (2.84) 34.5 (7.84) 32.0 (7.27) 3. Values calculated for factory-installed set of 1, 2, and 3 in. paddles. 27.5 (6.24) 19.0 (4.32) 53.0 (12.0) 50.0 (11.4) 65.0 (14.8) 50.0 (11.4) 128 (29.1) 122 (27.7) 125 (28.4) 101 (22.9) 245 (55.6) 235 (53.4) 190 (43.2) 158 (35.9) 375 (85.2) 360 (81.8) 375 (85.2) 320 (72.7) 760 (173) 730 (166) Table 4: F61KB, F61LB, and F61MB Models, 6 in. Paddles* GPM (m 3 /hr) Required to ctuate Switch Pipe Size (in.) 4 5 6 8 Minimum (R to Y 37.0 (8.40) 57.0 (12.9) 74.0 (16.8) 205 (46.6) djustment (R to B 27.0 (6.13) 41.0 (9.31) 54.0 (12.3) 170 (38.6) Maximum (R to Y 81.0 (18.4) 118 (26.8) 144 (32.7) 415 (94.3) djustment (R to B 76.0 (17.3) 111 (25.2) 135 (30.7) 400 (90.8) * Where paddle size is larger than pipe size, values are for 6 in. paddle trimmed to fit pipe. 6 F61 Series Standard Switches Installation Instructions

Table 5: F61MG Models, 1-3 in. Paddles GPM (m 3 /hr) Required to ctuate Switch Pipe Size (in.) 1 1-1/4 1 1-1/2 1 2 2-1/2 2 3 4 3 5 3 6 3 8 3 Minimum djustment Maximum djustment (R to Y (R to B (R to Y (R to B 3.80 (0.86) 2.50 (0.57) 8.70 (1.98) 8.50 (1.93) 5.30 (1.20) 3.70 (0.84) 13.1 (2.98) 12.5 (2.84) 1. Values for 2 in. paddle trimmed to fit pipe. 2. Values for 3 in. paddle trimmed to fit pipe. 6.90 (1.57) 5.00 (1.14) 18.8 (4.27) 18.0 (4.09) 12.7 (2.88) 9.50 (2.16) 28.9 (6.56) 27.0 (6.13) 16.7 (3.79) 12.5 (2.84) 33.7 (7.65) 32.0 (7.27) 3. Values calculated for factory-installed set of 1, 2, and 3 in. paddles. 24.3 (5.52) 19.0 (4.32) 52.1 (11.8) 50.0 (11.4) 61.0 (13.8) 50.0 (11.4) 126 (28.6) 122 (27.7) 118 (26.8) 101 (22.9) 243 (55.2) 235 (53.4) 183 (41.6) 158 (35.9) 372 (84.5) 360 (81.8) 362 (82.2) 320 (72.7) 753 (171) 730 (166) Table 6: F61MG Models, 6 in. Paddles* GPM (m 3 /hr) Required to ctuate Switch Pipe Size (in.) 4 5 6 8 Minimum (R to Y 35.0 (7.95) 53.0 (12.0) 69.0 (15.7) 197 (44.7) djustment (R to B 27.0 (6.13) 41.0 (9.31) 54.0 (12.3) 170 (38.6) Maximum (R to Y 80.0 (18.2) 116 (26.3) 142 (32.2) 412 (93.6) djustment (R to B 76.0 (17.3) 111 (25.2) 135 (30.7) 400 (90.8) * Where paddle size is larger than pipe size, values are for 6 in. paddle trimmed to fit pipe. Checkout IMPORTNT: Ensure installation, wiring, and control settings are according to the application requirements. Refer to the controlled system s manufacturer specifications for the proper settings when adjusting these controls. pply power to the control and controlled equipment. Cycle the controlled system at least three times at normal operating conditions. The circuit between the red and the yellow leads (terminals) closes when sufficient fluid flows through the pipe to trip the F61 flow switch. F61 Series Standard Switches Installation Instructions 7

Troubleshooting Use the information in Table 7 to troubleshoot the flow switch. Table 7: Troubleshooting Symptom/Problem Water (condensate) is within the enclosure. Fluid from the tank is leaking into enclosure due to bellows failure. Switch does not activate due to debris caught within the switch mechanism. Control switch action is reversed. Repairs and Replacement Do not make field repairs, except for replacement of the cover and paddles. For a replacement flow switch, paddle kit or cover, contact the nearest Johnson Controls/PENN distributor. For more information, contact Refrigeration pplication Engineering at (800) 275-5676. Solution Use a model with a NEM 3R enclosure. If using a model with a NEM 3R enclosure, inspect the grommet in the conduit fitting. Replace grommet if defective. Replace flow switch. Clear any debris within the switch mechanism. Test the operation of switch several times for proper operation. Ensure connections follow wiring diagrams. Control does not switch. Check connections. Switch fails to return to the no flow position. Control does not switch on flow increase. Switch is set lower than the factory setting. the setting. On vertical pipes, ensure that direction of flow is up. The arrow on switch must point in direction of flow (up). Check for cracked/broken paddle. Replace if necessary. Electrical Ratings Table 8: Electrical Ratings for F61KB, F61LB, and F61MB Models Electrical Ratings 120 VC 208 VC 240 VC 277 VC Horsepower 1 1 1 - Full Load mperes 16.0 8.8 8.0 - Locked Rotor mperes 96.0 52.8 48.0 - Non-inductive mperes 16.0 16.0 16.0 16.0 Pilot Duty 125 V at 24/277 VC Table 9: Electrical Ratings for F61MG Models Electrical Ratings 120 VC Full Load mperes 1 Locked Rotor mperes 6 Non-inductive mperes 2 Pilot Duty 125 V at 24/277 VC 8 F61 Series Standard Switches Installation Instructions

Technical Specifications Product Maximum Fluid Pressure Minimum Fluid Temperature Maximum Fluid Temperature Switch Wiring Connections Pipe Connector Conduit Connection gency Listings UL Listed CS Certified Shipping Weight F61 Series Standard Switches 150 psig (1034 kpa) 32 F (0 C) (F61KB, F61LB) -20 F (-29 C) (F61MB, F61MG) 250 F (121 C) Single Pole Double Throw Type Terminals (F61KB, F61LB) Four Color-coded No. 14 WG Solid Conductor Wire Leads, 7 in. (178 mm) Long (F61MB, F61MG) 1 in. 11-1/2 NPT Threads One 7/8 in. (22 mm) Hole for 1/2 in. Conduit with in. (29 mm) Knockout Ring for 3/4 in. Conduit (F61KB) Female Hub for 1/2 in. Conduit, 1/2-14 NPSM Threads (F61LB, F61MB, F61MG) E5368, CCN NMFT LR948, Class 3211 06, Class 4813 02, Class 1222 01 (F61KB) (F61LB - Not CS Certified) LR948, Class 3211 06 (F61MB, F61MG) 2.8 lb (1.3 kg) The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. Refer to the F61 Series Switches Product/Technical Bulletin (LIT-125225) for necessary information on operating and performance specifications of this product. Building Efficiency 507 E. Michigan Street, Milwaukee, WI 53202 Johnson Controls and PENN are registered trademarks of Johnson Controls, Inc. in the United States of merica and/or other countries. ll other trademarks used herein are the property of their respective owners. Copyright 2014 by Johnson Controls, Inc. ll rights reserved. F61 Series Standard Switches Installation Instructions 9