Scan Digital Radiography for Long Bone. DDR Inventor-V. Medical Device. Joint Star Business for Medical Device

Similar documents
COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X

I SEE THE FUTURE

EPEX. The Hologic EPEX General. Direct-to-Digital System for General Radiography. Versatility for a complete range of general radiographic exams

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

The Convenient and Compact CR System for Veterinary Practices

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

The convenient and compact CR system for veterinary practices

Page: 1 of 6 Page: 1 of 6

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

INTRODUCTION. A. Purpose

DR Retrofit Kit 1417 WL Configuration Integrated PACS

Data. microcat +SPECT

AN INNOVATIVE & CUTTING-EDGE DIGITAL RADIOGRAPHY SYSTEM

DENTAL Cone beam 3D X-RAY SYSTEM with

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT

I-Max Touch Range. PAN / CEPH / 3D digital panoramic unit. Evolutive 3 in 1 panoramic unit

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

X-RAY IMAGING Emerging Digital Technology - CMOS Detectors

Digital panoramic X-ray for practical diagnostics

Digital radiography conquers the veterinary world

Dealer Product Letter

Digital Dental X-ray. Midmark Animal Health Products

Purchasing a cardiac CT scanner: What the radiologist needs to know

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

REGIUS History. Touch REGIUS110. REGIUS170 ImagePilot REGIUS150 REGIUS330 CS-1

Equipment. Lin muyan. Presented by: CocticaUwititonze Cell:+250 (0)

Digital Mammography Update: Design and Characteristics of Current Systems

CR 30-Xm. CR 30-Xm Digitizer

X-ray (Radiography) - Chest

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Fundamentals of Cone-Beam CT Imaging

QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES. (a) Applicability. (b) Definitions

Clinic. ED Trauma Trauma Stroke. OR Neuro/Spine. Critical Care. Neuro ENT. Diagnostic. Pediatric. Radiology. Plastics Thoracic. Neuro.

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids

MEDICAL IMAGING. 90/30 Remote Controlled RF System

Application of Digital Radiography for the Detection and Classification of Pneumoconiosis

X-ray (Radiography) - Bone

Comparing Digital and Analogue X-ray Inspection for BGA, Flip Chip and CSP Analysis

Name: Date: Team: Lab Experiment # 3. Focused Grid Positioning Errors. Computed Radiography and Direct Digital Radiography

Overview. Digital X-ray imaging

Cardius. XPO Series. Cardius 3 XPO

Cargo Container X-ray Inspection Systems

Study the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

K ODAK D IRECTV IEW CR 850 SYSTEM

Remote RadEye Product Family

Cutting Edge Digital Radiography Technology in Daily NDT Use

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

3D Accuitomo FPD XYZ Slice View Tomograph. Super-High Resolution Images of Region of Interest

CONTENT SPECIFICATIONS FOR THE FLUOROSCOPY EXAMINATION

Checklist for the Qualification of Digital Detector Array Systems

Performance testing for Precision 500D Classical R/F System

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Quality Control and Maintenance Programs

Veraview IC5 HD High definition, digital imaging excellence. Thinking ahead. Focused on life.

X-ray (Radiography), Chest

The professional for your diagnostics.

Cirrus 0.2T. MRI for Everyone. North America, Asia, Europe. contact:

I.7. SOFT TECHNIQUE STILL IN USE IN CHEST RADIOGRAPHY PROS AND CONS

The Exposure Index and Its Standardization

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis

Development of on line monitor detectors used for clinical routine in proton and ion therapy

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abu Bakar School of Medical Imaging KLMUC

X-ray Imaging Systems

X-Rays Benefits and Risks. Techniques that use x-rays

16 th IOCCG Committee annual meeting. Plymouth, UK February mission: Present status and near future

Image Acquisition and Diagnostics

Graphical displays are generally of two types: vector displays and raster displays. Vector displays

TOF FUNDAMENTALS TUTORIAL

Image Quality and Radiation Dose for Intraoral Radiography: Hand-Held Held (Nomad), Battery Powered

X-Mind. Instinct for perfection

TISSUE MIMICKING GEL QUALITY LE PHANTOM SERIES DESIGN. performance the ultrasound labs ofand. icking material has the same attenuation mim-

CARESTREAM DIRECTVIEW CR Long-Length Imaging System

Encoders for Linear Motors in the Electronics Industry

Whitepaper. Image stabilization improving camera usability

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

Spiral CT: Single and Multiple Detector Systems. AAPM Refresher Course Nashville, TN July 28,1999

X-ray (Radiography) - Abdomen

Application Note. ipix A Gamma imager to support various applications

Endoscopy & X-Ray Image Sensors Markets

Rodenstock Photo Optics

Systematic X-ray diagnostics as flexible and individual as your dental practice.

Surveying and QC of Stereotactic Breast Biopsy Units for ACR Accreditation

icr3600 icr3600m VertX idr Film Digitizers Clarity PACS Innovative Medical Imaging

Digital Breast Tomosynthesis QC Requirements

Measuring Size and Distance in Digital Mammography

Quality Assurance. The selection of the equipment. Equipment Specifications. Medical Exposure Directive 97/43 Euratom. Quality Assurance Programme

Tom Wilson Product Marketing Manager Delivery Systems Varian Medical Systems International AG. CERN Accelerator School, May 2015

RVG Innovation set free.

A Breakthrough in Breast Specimen Imaging

Bergen Community College Division of Health Professions/ Radiography Program. Course Syllabus and Course of Study for Lecture

Radiation safety in dental radiography

OR Technology Reliable Partner for Security Applications. Security. Digital Radiography

SUMMARY OF CURRENT UK LEGISLATION AND GUIDELINES

Elements of required physical infrastructures: space, schielding, and patient flow..

Transcription:

Scan Digital Radiography for Long Bone DDR Inventor-V Medical Device Joint Star Business for Medical Device

JSB, leading the way in Long Bone Imaging Chest, Whole Spine, Long Bone and Sectional Imaging The DDR Inventor-V does it all brilliantly

Innovative Scanning Technology for Humans JSB has launched its upgraded version of DDR Inventor-V in an effort to bring about ground-breaking innovation, safety and efficiency for radiologists Company Profile JSB Medics is a medical device company specialized in the development and manufacture of products used today in radiology. An extensive sales agent network worldwide specializes in the representation of a range of well-known international medical corporations with high quality sophisticated imaging products. JSB Medics has been certified in accordance with ISO 9001:2008 / ISO 13485:2003. The management undertakes regular evaluations of the efficiency of the quality assurance system by analysing internal audits and takes the measures required to ensure constant further development and improvement of the QM system. JSB Medics will be a recognized leader in medical imaging and radiography systems markets, building a sustainable competitive advantage through proprietary technology, reliable products, excellent customer service and sound business practices. Mission Statement To be a leading supplier of high quality, professionally used instruments, components and systems in selected medical niche markets based on our own design and original creation, while providing superior customer support and services. Mutual Respect & Trust JSB, Joint Star Business for Medical Device Medical Device Proprietary Technology Top Quality Products Superior Customer Service JSB Medics 02 03

JSB, leading the way in Long Bone Imaging DDR Inventor-V for Long Bone Overview DDR Inventor-V for Long Bone is a linear X-ray scanner which is designed to produce high quality, distortion free images with very low X-ray doses. It is designed to capture the whole spine & long bone image of a standing patient with a single scan without the need for stitching or vertical distortion. This lack of vertical distortion provides true size images in 1:1 scale for highly accurate measurements. Clever design also ensures equally high quality small body part sectional imaging. DDR Inventor-V adopts MIC detector with direct conversion of incident X-ray to electric signal, high fill factor without dead zone and without dead pixel, as well as a scanning system that can prevent scattered radiation with fan beam. These characteristics of MIC detector provide merit of high image quality with low dose irradiation against patient. DDR Inventor-V works by means of a vertical drive mechanism which moves the X-ray source and detector along the vertical axis to cover a field of up to 42 x 110 cm in a single continuous scan. It takes a maximum of 2.5 seconds and 5 seconds to do a chest and long body scan respectively. As soon as the scan is completed, data processing and digital image acquisition takes place within 2 seconds. The image produced is scalable allowing medical personnel to look at the full spine or long bone in one glance or zoom into a specific detail. In addition, the image, being digital, can be easily distributed. The system is fully PACS compatible for DICOM distribution and management. Control Window Database Window Process Window

Innovative Scanning Technology for Humans Health System Benefits 14-bit contrast range (4 times wider than CR) improved diagnostic capability. No distortion in the vertical axis (ideal for chiropractic and orthopaedic measurement) Up to 110 cm FOV (whole spine or whole leg in one scan no stitching) improved diagnostic capability and saving in staff time. Long life, robust gas detector reduced life cost of hardware. Stand alone package can be accommodated with minimal preinstallation works and disruption to existing departments. Very low dose (entrance surface dose less than one tenth of that required by conventional CR systems) ideal for paediatrics and repeat examinations. Low-dose weight bearing examination bridges the diagnostic gap between (frequently inconclusive) conventional X-ray and (rare, expensive) upright MRI with optimal cost/risk ratio and good patient compliance. Affordable and convenient price comparable with a conventional CR chest/bucky room, with negligible preinstallation requirement (using the standalone cabinet). Its speed of operation makes it a high throughput system that increases efficiency in patient exam time. Reasonable cost and low operational maintenance related expenses of the detector. The scanning system enjoys a long lifetime with constant image quality. Economic Operation & Maintenance DDR Inventor-V is an economic solution, since the MIC detector boasts long life time with consistent image quality. Supplied as a complete integrated system, the system price is far below comparable existing FPD DR system. FPD DR plates in particular are fragile and expensive. CR plates are inherently subject to wear. The MIC detector used in DDR Inventor-V does not suffer from wear or exhibit interpixel dead zones and is possible to replace if damaged. In addition, use of the DDR Inventor-V requires up to 80% less time to manage patients and display an image than CR; this may speed up the consultation process and potentially decrease associated staff costs. DDR Inventor scanning technology ensures reasonable cost of entry and low operational and maintenance costs. Potentially offsetting, the cost of the DDR Inventor-V is a reduction in investment in alternative CR or DR systems, the cost of which can vary significantly, and a reduction in the number of conventional X-rays (including repeat tests) carried out. More important than initial cost, the life of ownership costs is attractive due to low ongoing and maintenance costs. Even the core MIC detector is serviceable if ever required. MIC Detetor Scan-DR Direct Conversion No Dead Zone SCAN Type No Scatter Arbitrary Image Size No Distortion ~2.5ms / line scan High Quality Image Low Dose JSB Medics 04 05

JSB, leading the way in Long Bone Imaging DDR Inventor-V for Long Bone Low Dose Radiation DDR Inventor-V scanning method ensures shorter exposure times than other radiography systems, which can be significant if the patient requires multiple X-rays, for example with scoliosis. The exposure time is effectively defined by the time of passing of the narrow beam over the selected tissues. This highly focused beam effectively eliminates large area X-ray doses, so reducing radiation exposure risk to patients and to staff. Patient is exposed to radiation layer-by-layer, as against the traditional radiography techniques where a wide beam acts simultaneously on the entire anatomical area. The low dose radiation has been identified as being particularly beneficial to scoliosis patients. X-ray dose used is estimated to be about 25% of other equivalent techniques. The patient dose is a factor of 10 less than conventional CR systems, which is very important for scoliosis work. It produces minimal amount of X-ray scatter which further minimizes radiation exposure to patients and users. The combinations of high sensitivity detector, narrow fan beam, absence of anti-scatter grid and short effective exposure time serve to lower patient exposure dose levels. With JSB DDR scanning system, the lower levels of radiation allow careful reconsideration of safe procedures for children and pregnant women. Time Saving & Efficient DR DDR Inventor-V does not need a long-size cassette for whole spine / long body, eliminating time-consuming stitching process and creating full spine or long bone images on one exposure. This system is equally efficient in sectional and small body part examination. Workflow is once again streamlined by a single exposure hence reducing dose and discomfort to the patient and increasing user s productivity and throughput. Time to manage the patient and display an image is reduced by about 80% compared with CR. High speed of scanning ensures DDR systems are ideally suited to high throughput scenarios. Its instantaneous x-ray exposure greatly reduces motion artifacts, thus the patient does not need to be completely still while imaging. The technology allows for imaging without vertical distortion. This results in a more accurate image that improves patient assessment and treatment planning. The new technology does not suffer from stitching artifacts and a single-shot 110 cm long FOV is possible - an advantage when carrying out orthopaedic implants and when tracking patient progress. The conventional technology suffers from magnification errors whereas in the vertical axis the upright X-ray unit does not. Being a digital all-in-one imaging system, distribution and delivery is fast and uncomplicated. Highly efficient for general diagnostic, chiropractic, scoliosis or growth analysis assessments. Better image contrast over existing technology leading to improved diagnostic score. Fully PACS compatible for DICOM distribution and management.

Innovative Scanning Technology for Humans MIC Detector - JSB Core Technology Design of MIC Detector Direct Conversion Most digital radiography systems which are based on charge-coupled device (CCD) and amorphous silicon (a-si) are of indirect conversion type that uses scintillator to convert incident X-ray into visible light. That is, they need two-step process to get electric signal for digital image and the image quality is significantly affected by scintillator. DDR Inventor-V, however, adopts a Multi-channel Ionization Chamber (MIC) detector, which has intrinsic features of high efficiency by directly converting incident X-ray to an electric signal. Once X-ray irradiation passes through the patient, it penetrates the space between the electrodes and the gas in the MIC is ionized to generate charges by the X-ray, and then quantified by the ion counter before being turned into an image. Visible light Optical coupling to CCD High Fill Factor and No Dead Pixel Fill factor is the ratio of the sensitive area of the pixel to the effective area of the detector element itself. If the fill factor is small, light photons from a part of incident X-ray may never be recorded. MIC detector has no loss of effective sensing area because most ions are captured between the electrodes. Above all, MIC detector has nearly no dead pixel by its intrinsic characteristics. [ Flat panel detector ] [ MIC detector ] High Reliability The MIC detector has strong durability on operating environment such as surrounding temperature (-10 ~ 45 ), humidity, vibration and treatment. This feature provides users with benefit on the maintenance for economic operation. JSB Medics 06 07

Advantages of Scanning Method JSB, leading the way in Long Bone Imaging No Scatter Scattered X-ray photons can contribute very significantly to the exposure of the image. In screen-film or flat panel type radiography, scattered radiation causes a reduction of contrast of the image. The main effect of scattered radiation is to increase the noise of image. Grids are used to reduce scattered radiation, but can also produce artifacts on the image. In the case of Scan DR, the fan beam collimator reduces scattered radiation from patient and the linear structure of detector further limits incident scatter from the patient. Therefore, there is no need for severe image processing to remove the noise from scattered radiation and image processing speed is very fast. Film & flat panel type Need for the grid filtering Scan type No Need for the filtering Low Dose Normal exposure time of conventional screen-film radiography for chest is about 0.01~0.05 sec. In the case of Scan DR, exposure time per line depends on scanning speed and is under 0.005 sec. at normal scan speed. Therefore, effective exposure time of Scan DR is shorter than that of other radiography systems. In addition, characteristics of MIC detector such as direct conversion, low scattered radiation and high fill factor contribute to high image quality and also to low radiation dose on patients. No Distortion The film-screen, CR and flat plate type detector cannot avoid the image distortion in vertical and horizontal directions. Scan DR shows real size of image in the vertical direction. Film/flat panel type Scan type Actual size Not Exact Scale Exact 1:1 Scale of Vertical Direction

Innovative Scanning Technology for Humans System Specifications PARTS TECHNICAL SPECIFICATION X-RAY GENERATOR Power rating: 40kW Line nominal, Phase: 230VAC~, 400/480V3 3 ~ kv range: 40 to 125kV, 1kV step, 40 to 150kV for V3 3 ~ ma range: 10 to 500mA Time range: 0.001 to 10sec., 38 steps mas range: 0.1 to 500mAs (Optional higher mas) Anatomical programs: User programmable max 1,280 programs with APR utility software X-RAY TUBE Max kvp: 150kV Focal spot: 0.6/1.2mm Max HU: 1,000,000HU Anode rotation: 2,700RPM at 50Hz 3,200RPM at 60Hz 8,100RPM at 150Hz 9,700RPM at 180Hz Target angle: 12 DETECTOR (MSGC) Detector type: Micro strip gas chamber type linear detector Receptor type: Gas ionization Image size: 410mm x 1,100mm (16 x 43 ) Fill factor: almost 100% Pixel pitch: 200 μm Matrix of pixel: 2,048 x 5,710 (Max) A/D conversion: 14Bit Resolution: 2.5lp/mm Scan speed: 10, 14, 21cm/sec. Scanning time: 5sec. (21cm/sec. for 39 ) Preview time: Within 1sec. Image acquisition time: Within 2 sec. Power consumption: 12W Max Power requirement: 60Hz AC220V PATIENT ELEVATOR Stroke: 400mm ±10mm Max weight capacity: 150kg X-ray Room Layout JSB Medics 08 09

JSB, leading the way in Long Bone Imaging DDR Inventor-V for Chest Optimized Design for Chest Screening DDR Inventor-V for Chest is equipment mainly for chest screening to provide the high quality of chest image with lower exposure of X-ray compared to conventional equipment. This scanning digital radiography provides efficient image management system including Imaging Server/ Client and Viewer and is completely compatible with PACS system. Cost-effective Innovation DDR Inventor-V, an innovative and cost-effective digital radiography system, is a fully integrated solution that is designed to increase efficiency in patient exam time. The DDR Inventor-V for Chest offers quicker turnaround for digital images and eliminates everything associated with film processing from an analogue facility. This system has alleviated work flow back-ups and users will now be able to see more patients in a day.

Innovative Technology For Humans DDR Inventor-V with Shielding Shield Room for Space & Cost Saving DDR Inventor-V can be supplied with a capsule-type shield room. This mini X-ray room functions as an all-in-one digital clinic which saves space and allows the system to be installed in confined areas such as consulting rooms. The space-saving design incorporates operator control area, full shielding and image review station, ultimately reducing installation costs. Fully shielded system requires only 3,000mm x 1,500mm of room space. Time Saving for Operator & Patient Taking X-rays directly in front of the equipment is possible, which will save the operator s time in walking to the control room. And operator can take the X-ray near the patient, aiding in stability in the patient while shortening the time necessary to take the X-ray. Shielding Room Layout JSB Medics 10 11

Joint Star Business for Medical Device 201-901 Bucheon Techno-Park, 192 Yandae-Dong, Wonmi-Gu, Bucheon- City, Gyeonggi-Do, 420-733 Korea Tel : +82-70-8224-8700 Fax : +82-32-321-8708 E-mail : sales@jsbmed.com Homepage : www.jsbmed.com www.jsbmed.com Rev.2